Atek
Atek
T5=100 T5=100 Cyclohexane 259°C Normally not, Metal dusts lll C Class ll / GP E
Example marking
T6=85 T6=85 Zone 22 only for a short Dc
II 2 G Ex db IIC T4 Gb
* Diethyl ether 170°C period
Equipment marking
0344 ºC Carbon
95°C
disulfide
*Complies with UKCA requirements
Ex identification acc. to standard (example)
Conditions in potentially explosive areas ATEX 2014/34/EU Gas and dust groups
Associated
Dust temperature: apparatus. [ ]
Typical ANSI/ISA
EPL Identification Max. surface temperature is shown in full in the markings for dust, *RED text in markings above applies to US only. [AEx ia] IIC Transmits to or Associated
gas / dust 60079-0
e.g. T90°C. receives signal equipment
Explosive Presence of Zone Equipment
Equipment group from Ex area.
Atmosphere explosive atmoshere Classification category Methane I Note:
Equipment
US installations may use the zone or division marking scheme.
protection level Propane II A
New installations in Canada must use the zone marking ANSI/ISA Installation
scheme, while existing installations may use either scheme. AEx ia IIC T6 Equipment
Ethylene II B 60079-0 in Ex area.
I M1 Ma System 9000
Parts at coal mines endangered by Hydrogen II C
Coal Mines 9106B - AI HART transparent
firedamp and / or combustible dust
I M2 Mb Combustible flyings III A 9107B - AO HART transparent
9113B - AI temperature converter Protection types - Zone Scheme
Non-conducting dust III B 9116B - AI universal w/ limit switch
Continuous, long
Zone 0 II 1G, (1)G Ga 9202B - DI pulse isolator
periods, frequent Conducting dust III C Protection method Type Zones Hazard type Standard ISA / UL / CSA Concept
Gas 9203B - DO solenoid/alarm driver
Vapor Occasional Zone 1 II 2G, (2)G Gb General requirements All All 60079-0
Mist
Normally not, only for
Ex identification acc. to standard (example) ia
0, 1, 2 Gas
Zone 2 II 3G, (3)G Gc 20, 21, 22 Dust
a short period
Continuous, long EN / IEC Associated 1, 2 Gas
Zone 20 II 1D, (1)D Da [Ex ia Ga] IIC Intrinsic safety ib 60079-11 Limiting ignition energy
periods, frequent 60079-0 apparatus. [ ] 21, 22 Dust
Dust Transmits to or Associated
Fibers Occasional Zone 21 II 2D, (2)D Db receives signal equipment 2 Gas
EN / IEC ic
Flyings [Ex ia] IIC from Ex area.
60079-0 22 Dust
Normally not, only for
Zone 22 II 3D, (3)D Dc
a short period eb 1, 2 Gas
EN / IEC Increased safety 60079-7 Prevention of sparks
Ex ia IIC T6 Ga
60079-0 Installation ec 2 Gas
Continuous operation in Equipment
Use in the defined Ex area 1G category M1 in Ex area
explosive atmosphere EN / IEC da 0, 1, 2 Gas
Ex ia IIC T6 System 7900
60079-0
Associated apparatus. Transmits to No operation in 7908 - 8 module backplane Flameproof enclosures db 1, 2 Gas 60079-1
(1)G category M2 Propogation prevention
or receives signal from Ex area. explosive atmosphere 7916 - 16 module backplane
dc 2 Gas
Powder filling q 1, 2 Gas 60079-5
Restricted breathing nR 2 Gas 60079-15
Protection types (ATEX / IECEx / UKEx) System 7500
7501 - F
ield mounted HART Sealed device nC 2 Gas 60079-15
Protection temperature transmitter pxb 1, 2 Gas
Type Zones Hazard type IEC / EN standard Concept
method
1, 2 Gas
pyb
General System 5300 / 5400 Pressurization 21, 22 Dust 60079-2
All All 60079-0
requirements 5331D - Universal temperature isolated
2 Gas
0, 1, 2 Gas 5332D - RTD - Pt100 / Lin. R, 4-wire pzc
ia 5333D - RTD - Pt100 / Lin. R, 3-wire 22 Dust
20, 21, 22 Dust 5334B - TC isolated
5335D - Universal temperature HART 5 pb 1, 2 Gas
1, 2 Gas
Intrinsic safety X ib 60079-11 Limiting ignition energy 5337D - Universal temperature HART 7 Pressurized room pc 2 Gas 60079-13
21, 22 Dust 5343B - Level - Lin. R / Potentiometer
5437D - 2
-wire HART 7 temperature vc 2 Gas
2 Gas Prevents ingress
ic transmitter 0, 1, 2 Gas of explosive
22 Dust ma atmopshere
20, 21, 22 Dust
eb 1, 2 Gas
Increased safety X ec 2 Gas
60079-7 Prevention of sparks 1, 2 Gas
Encapsulation mb 60079-18
21, 22 Dust
Non-sparking nA 2 Gas EN 60079-15 No arcs, sparks or hot surfaces System 5000
5104B - AI repeater / power supply 2 Gas
da 0, 1, 2 Gas 5105B - AO isolated driver mc
Flameproof 5106B - AI HART transparent 22 Dust
db 1, 2 Gas 60079-1
enclosures 5114B - AI universal converter ob 1, 2 Gas
dc 2 Gas Propogation prevention 5115B - AI universal calculator Liquid immersion 60079-6
5116B - AI universal w/ limit switch oc 2 Gas
Powder filling q 1, 2 Gas 60079-5 5131B - AI universal converter LP ta 20, 21, 22 Dust
5202B - DI NAMUR/contact input
5203B - DO solenoid/alarm driver Protection by enclosure tb 21, 22 Dust 60079-31
Restricted breathing nR 2 Gas 60079-15
5223B - DI frequency converter tc 22 Dust
Sealed device nC 2 Gas 60079-15
1, 2 Gas Prevention of optical
pxb 1, 2 Gas op pr
21, 22 Dust energy release
1, 2 Gas
pyb 0, 1, 2 Gas Limiting optical
Pressurization 21, 22 Dust 60079-2 Optical radiation op is 60079-28
20, 21, 22 Dust energy
2 Gas
pzc 0, 1, 2 Gas Interlocked with optical
22 Dust op sh
20, 21, 22 Dust breakage
pb 1, 2 Gas
Pressurized room
pc 2 Gas 60079-13 5531B 4-digit LCD
Artificially ventilated vc 2 Gas Ex loop-powered display Example Division scheme marking
www.prelectronics.com
1016UK (2418)