0% found this document useful (0 votes)
149 views22 pages

Multifunction Meters & Relays Catalog

The document describes various types of digital meters and controllers including multifunction meters, energy meters, amp meters, volt meters, frequency meters, and power factor controllers. The meters and controllers come in LCD or LED display styles and are suitable for measuring 1-phase or 3-phase systems. They vary in size, features, and price range from approximately Rp210,000 to Rp2,750,000.

Uploaded by

nurkhoir9
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
149 views22 pages

Multifunction Meters & Relays Catalog

The document describes various types of digital meters and controllers including multifunction meters, energy meters, amp meters, volt meters, frequency meters, and power factor controllers. The meters and controllers come in LCD or LED display styles and are suitable for measuring 1-phase or 3-phase systems. They vary in size, features, and price range from approximately Rp210,000 to Rp2,750,000.

Uploaded by

nurkhoir9
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 22

DIGITAL MULTIFUNCTION METER

Picture FuncƟon DescripƟon Type Size Price (Rp)


• 3Ɍ ( True rms ) Voltage 3Phase LCD MulƟfuncƟon Meter
• 3Ɍ ( True rms ) Current > With bargraph of Current MFM384-C 96 X96 2,750,000
• 3Ɍ kW, kVA, kVAr, KWh, kWAh, kWArh > With CommunicaƟon (RS485)
• 3Ɍ Power Factor > Input : 3Ɍ-3W/4W, 2Ɍ-3W, 1Ɍ-2W
• Frequency
• Total Harmonic DistorƟon 3Phase LCD MulƟfuncƟon Meter
• Demand (Min/Max AcƟve Power, Min/Max > With bargraph of Current MFM384 96 X96 2,000,000
ReacƟve Power, Max Apparent Power ) > Without CommunicaƟon (RS485)
• Programmable CT/PT Pramary / Secondary > Input : 3Ɍ-3W/4W, 2Ɍ-3W, 1Ɍ-2W
• Modbus RTU communicaƟon (RS485)
• Pluse Output

• 3Ɍ ( True rms ) Voltage 3Phase LCD MulƟfuncƟon Meter


• 3Ɍ ( True rms ) Current > With CommunicaƟon (RS485) MFM383A-C 96 X96 1,520,000
• 3Ɍ kW, kVA, kVAr, KWh, kWAh, kWArh > Input : 3Ɍ-3W/4W, 2Ɍ-3W, 1Ɍ-2W
• 3Ɍ Power Factor
• Frequency
• Programmable CT/PT Pramary / Secondary 3Phase LCD MulƟfuncƟon Meter MFM383A 96 X96 1,265,000
• Modbus RTU communicaƟon (RS485) > Without CommunicaƟon (RS485)
• Pluse Output > Input : 3Ɍ-3W/4W, 2Ɍ-3W, 1Ɍ-2W

• 3Ɍ ( True rms ) Voltage 3Phase LED MulƟfuncƟon Meter


• 3Ɍ ( True rms ) Current > Input : 3Ɍ-3W/4W, 2Ɍ-3W, 1Ɍ-2W MFM376 96 X96 1,050,000
• kW, kVA, kVAr, KWh, kWAh, kWArh
• 3Ɍ Power Factor
• Frequency
• Demand (Min/Max AcƟve Power, Min/Max
ReacƟve Power, Max Apparent Power )
• CT Polarity Error
• Single Pluse Output

1
DIGITAL VAF & ENERGY METER (KWh)

Picture FuncƟon DescripƟon Type Size Price (Rp)


• 3Ɍ ( True rms ) Voltage 3Phase LCD (V, A, Hz) Meter
• 3Ɍ ( True rms ) Current > With bargraph of Current VAF36A 96 X 96 930,000
• Frequency (HZ) > Input : 3Ɍ-3W/4W, 2Ɍ-3W, 1Ɍ-2W
• Run Hour ( hour meter )
• RPM
• Programmable CT Primary
• Programmable PT Primary & PT Secondary

• 3Ɍ ( True rms ) Voltage 3Phase LED (V, A, Hz) Meter


• 3Ɍ ( True rms ) Current > Input : 3Ɍ-3W/4W, 2Ɍ-3W, 1Ɍ-2W VAF39A-1 96 X 96 600,000
• Frequency (HZ)
• Run Hour ( hour meter )
• RPM
• Programmable CT Primary
• Programmable PT Primary & PT Secondary

• 3Ɍ Power ( AcƟve, ReacƟve ) 3Phase LCD Energy Meter


• 3Ɍ Power Factor > Input : 3Ɍ-3W/4W, 2Ɍ-3W, 1Ɍ-2W EM368-C-CU 96 X 96 2,000,000
• 3Ɍ kW, kVA, kVAr, KWh, kWAh, kWArh
• Programmable CT/PT Pramary / Secondary
• Modbus RTU communicaƟon (RS485)
• Pluse Output

• Energi AcƟve (KWh) 1Phase/3Phase LED KWh Meter


• Pluse Output > Input : 3Ɍ-3W/4W, 2Ɍ-3W, 1Ɍ-2W EM306-A 96 X 96 850,000
• Programmable CT Primery / Secondary

2
DIGITAL AMPERE METER
AC METER

Picture DescripƟon Type Size Price (Rp)


LCD Ampere Meter, 1Phase 2 Wire
> With analog style bargraph IndicaƟon MA201 72 X 72 410,000
> For 1 phase 2 wire connecƟon
> For 3 phase with selector swicth connecƟon MA301 96 X 96 410,000
> Input : 1Ɍ - 2wire ( with adapter Plate)

LCD Ampere Meter, 3Phase 4 wire


> With analog style bargraph IndicaƟon MA2301 72 X 72 500,000
> For 3 phase 4wire connecƟon
> Input : 3Ɍ - 4 wire / 3Ɍ - 3 wire MA3301 96 X 96 500,000
> Inbuilt keypad for selecƟon switch ( with adapter Plate)

LED Ampere Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MA302 96 X 96 210,000
> For 3 phase with selector swicth connecƟon
> Input : 1Ɍ - 2wire

LED Ampere Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MA202 72 X 72 210,000
> For 3 phase with selector swicth connecƟon
> Input : 1Ɍ - 2wire

LED Ampere Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MA12 48 X 96 210,000
> For 3 phase with selector swicth connecƟon
> Input : 1Ɍ - 2wire

LED Ampere Meter, 3Phase 4 wire


> Input : 3Ɍ-3W/4W or 1Ɍ-2W MA335 96 X 96 400,000
> Inbuilt keypad for selecƟon switch

3
DIGITAL VOLT METER
AC METER

Picture DescripƟon Type Size Price (Rp)


LCD Volt Meter, 1Phase 2 Wire
> With analog style bargraph IndicaƟon MV207 72 X 72 410,000
> For 1 phase 2 wire connecƟon
> For 3 phase with selector swicth connecƟon MV307 96 X 96 410,000
> Input : 1Ɍ - 2wire ( with adapter Plate)

LCD Volt Meter, 3Phase 4 wire


> With analog style bargraph IndicaƟon MV2307 72 X 72 500,000
> For 3 phase 4wire connecƟon
> Input : 3Ɍ - 4 wire / 3Ɍ - 3 wire MV3307 96 X 96 500,000
> Inbuilt keypad for selecƟon switch ( with adapter Plate)

LED Volt Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MV305 96 X 96 210,000
> For 3 phase with selector swicth connecƟon
> Input : 1Ɍ - 2wire

LED Volt Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MV205 72 X 72 210,000
> For 3 phase with selector swicth connecƟon
> Input : 1Ɍ - 2wire

LED Volt Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MV15 48 X 96 210,000
> For 3 phase with selector swicth connecƟon
> Input : 1Ɍ - 2wire

LED Volt Meter, 3Phase 4 wire


> Input : 3Ɍ-3W/4W or 1Ɍ-2W MV334 96 X 96 400,000
> Inbuilt keypad for selecƟon switch

4
DIGITAL VOLT & AMPERE
DC METER

Picture DescripƟon Type Size Price (Rp)


LED Volt Meter, 1Phase 2 Wire
> For 1 phase 2 wire connecƟon MV305-VDC 96 X 96 475,000
> For 3 phase with selector swicth connecƟon
> Input : 1Ɍ - 2wire
> Range maximum 200VDC

LED Volt Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MV15-VDC 48 X 96 475,000
> For 3 phase with selector swicth connecƟon
> Input : 1Ɍ - 2wire
> Range maximum 200VDC

LED Ampere Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MA302-VDC 96 X 96 400,000
> For 3 phase with selector swicth connecƟon
> Input : 1Ɍ - 2wire
> By Shunt Seƫng ( 5 - 4000A ), 75mV

LED Ampere Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MA12-VDC 48 X 96 400,000
> For 3 phase with selector swicth connecƟon
> Input : 1Ɍ - 2wire
> By Shunt Seƫng ( 5 - 4000A ), 75mV

5
DIGITAL FREQUENCY & POWER FACTOR METER

Picture DescripƟon Type Size Price (Rp)

LED Hz Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MF316 96 X 96 400,000
> Input : 1Ɍ - 2wire

LED Hz Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MF216 72 X 72 400,000
> Input : 1Ɍ - 2wire

LED Hz Meter, 1Phase 2 Wire


> For 1 phase 2 wire connecƟon MF16 48 X 96 400,000
> Input : 1Ɍ - 2wire

LED Power factor Meter / COS Ɍ


> For 1 phase 2 wire connecƟon MP314 96 X 96 500,000
> Input : 1Ɍ - 2wire

6
POWER FACTOR CONTROLLER

Picture DescripƟon Steps Type Size Price (Rp)


Power Factor Controller
> LED display, 4 digits 8 APFC147-108 144 X 144 2,200,000
> Single CT sensing
> Dual password protecƟon
> ConĮgurable alarm seƫng
> LED indicaƟon for alarm
> Input : L-N / L-L
> CT primary 1A / 5A up to 9999A 12 APFC147-112 144 X 144 2,600,000
> CT secondary 1 or 5A
> OperaƟng limit of Voltage Input :
40-300V (L-N), 50-500V (L-L)
> Alarm seƫng :
• Over voltage, under voltage, under compensaƟon,
• Over compensaƟon, CT polarity : ON/OFF
• Current absent indicaƟon : Crr
> Switching program : AutomaƟc / Linear / RotaƟonal
> Control mode : AutomaƟc / Manual
> Step Ɵme : 5 to 240 sec

Power Factor Controller


> LCD display with dual color backlight 8 APFC148-308 144 X 144 4,500,000
> 3 CT sensing
> Alarm linked signal contact
> Programmable Fan control
> MODBUS RTU CommunicaƟon
> Input : 3Ɍ-3W/4W, 2Ɍ-3W, 1Ɍ-2W
> CT primary 1A / 5A up to 9999A 12 APFC148-312 144 X 144 5,500,000
> CT secondary 1 or 5A
> OperaƟng limit of Voltage Input :
11-300V (L-N), 50-520V (L-L)
> Alarm seƫng :
• THDI
• Over voltage, under voltage, under compensaƟon,
• Over compensaƟon, CT polarity Error ON/OFF,
• Step Error 20-80% or oī, temperature 0-100϶C or ON or OFF
• Fan seƫng ON/OFF, %THDI 20-100% or OFF
> Switching program : AutomaƟc / Linear / RotaƟonal
> Control mode : AutomaƟc / Manual
> Step Ɵme : 5 to 240 sec

7
PROTECTION RELAYS
DIN RAIL MOUNTING

> Analog ProtecƟon Relay


Picture DescripƟon FuncƟon Type Price (Rp)

Analog Phase Sequence Relay • ProtecƟon :


> Input connecƟon : 3Ɍ/3Wire > Phase sequence / reverse
> OperaƟng Voltage : > Phase failure 800PSR 195,000
154 to 500VAC (L - L) , 50/60Hz > Phase asymmetry / Imbalance
> Output contact : 1 C/O (SPDT) > Reset : Auto
raƟng : NO/5A, NC/3A, 250VAC
> Power On Delay : 200 msec
> Trip Ɵme delay : 200 msec max.
> Accuracy : Trip ±10V
> Size : 22.5 X 76.85mm
Analog Phase Sequence Relay • ProtecƟon :
> Input connecƟon : 3Ɍ/3Wire > Phase sequence / reverse
> OperaƟng Voltage : > Phase failure
154 to 500VAC (L - L) , 50/60Hz > Phase asymmetry / Imbalance
> Output contact : 1 C/O (SPDT) > Reset : Auto 600PSR 460,000
raƟng : NO/5A, NC/3A, 250VAC
> Power On Delay : 200 msec
> Trip Ɵme delay : 0.2 to 10sec
> Accuracy : Trip ±10V
> Size : 17.5 X 90mm
Analog Phase Sequence Relay • ProtecƟon :
> Input connecƟon : 3Ɍ/3Wire > Phase sequence / reverse
> OperaƟng Voltage : > Phase failure
230VAC ±20% , 50/60Hz > Phase asymmetry / Imbalance
> Output contact : 1 C/O (SPDT) > Reset : Auto PSR1 400,000
raƟng : NO/5A, 250VAC
> Power On Delay : < 500 msec
> Trip Ɵme delay : 3.5sec
> Recovery Ɵme delay :
• phase failure & asymmetry : < 120ms
• phase sequence : < 250ms
> Accuracy : Trip seƫng ±1% of F.S
Time seƫng ±5%of F.S
> Size : 35 X 90mm

Analog Phase Sequence Relay • ProtecƟon :


> Input connecƟon : 3Ɍ/3Wire > Phase sequence / reverse
> OperaƟng Voltage : > Phase failure
230VAC ±20% , 50/60Hz > Phase asymmetry : 30 - 70V
415VAC ±20% , 50/60Hz > VA raƟng : 4VA max
> Output contact : 2 C/O (DPDT) > Reset : auto / manual / remote PSR2 550,000
raƟng : NO/5A, NC/3A, 250VAC > Reset gap : 10V(for manual/reset)
> Power On Delay : < 500 msec
> Trip Ɵme delay : 3.5sec
> Recovery Ɵme delay :
• phase failure & asymmetry : < 120ms
• phase sequence : < 250ms
> Accuracy : Trip seƫng ±1% of F.S
Time seƫng ±5%of F.S
> Size : 52.5 X 90mm
8
PROTECTION RELAYS
DIN RAIL MOUNTING

> Voltage ProtecƟon Relay


Picture DescripƟon FuncƟon Type Price (Rp)

Analog Voltage ProtecƟon Relay • ProtecƟon :


> Input connecƟon : 3Ɍ/3Wire > Under voltage
> OperaƟng Voltage : > Over voltage trip 600VPR 500,000
310 to 520VAC (L - L) , 50/60Hz > Phase sequence / reverse
> Output contact : 1 C/O (SPDT) > Phase failure
raƟng : NO/5A, NC/3A, 250VAC > Phase asymmetry / Imbalance
> Trip seƫng : > Reset : Auto
• Under voltage trip : -2.5% to -25% of 415VAC
• Over voltage trip : -2.5% to -25% of 415VAC
> Trip Ɵme seƫng :
• Power On Delay : 400 msec
• Trip Ɵme delay : 0.2 to 10sec
> Accuracy : Trip seƫng ±5% of F.S
Time seƫng ±5%of F.S
> Size : 17.5 X 90mm

Analog Voltage ProtecƟon Relay • ProtecƟon :


> Input connecƟon : 3Ɍ/4Wire, 1Ɍ/2wire > Under voltage
> OperaƟng Voltage : > Over voltage
127 to 288VAC (L-N) , 50/60Hz > Phase sequence / reverse
> Output contact : 2 C/O (DPDT) > Phase failure
raƟng : 5A, 250VAC / 28VDC > Phase asymmetry VPRA2M 450,000
> Trip seƫng :
• Under voltage: 55-95% of Un 127 to 219VAC (L-N)
• Over voltage: 105-125% of Un 242 to 288VAC (L-N)
• Phase asymmetery : >10%
> Trip Ɵme seƫng :
• Power On Delay : 0-15sec
• Trip Ɵme delay : 0-15sec
• Recovery Ɵme delay :5s ± 200ms
• L1/neutral loss trip delay : <250ms
• phase sequence trip delay : < 250ms
> Accuracy : Trip seƫng ±5% of F.S
Time seƫng ±5%of F.S
> Size : 35 X 90mm

Digital Voltage ProtecƟon Relay • ProtecƟon :


> Input connecƟon : 3Ɍ/4Wire, 3Ɍ/3wire > Under voltage
> OperaƟng Voltage : > Over voltage
160 to 300VAC (L-N), 280 to 520 (L-L), 50/60Hz > Under frequency
> Output contact : 2 x 1 C/O (SPDT) > Over frequency 900VPR-2 650,000
raƟng : NO/5A, NC/3A, 250VAC > Phase sequence / reverse
> Trip seƫng : > Phase failure
• Under / Over voltage : > Phase asymmetry
280 to 520VAC L-L ( for 3Ɍ/3wire system) • Monitoring in 3Ɍ system
160 to 300VAC L-N ( for 3Ɍ/4wire system) • True RMS meansurement
• Under / Over Frequency : 45 - 65Hz • Power ON delay
• Phase asymmetery : 5 - 99.9% • Trip Ɵme delay
> Trip Ɵme seƫng : • Recovery Ɵme delay
• Power On Delay : 2 - 99.9sec • Adjustable switching hysteresis
• Trip Ɵme delay : 0 - 99.9sec • Two separate alarm relays
• Recovery Ɵme delay : 0 - 99.9sec
• Response Ɵme : < 200ms
> Accuracy : Voltage : ±1% of set value.
Frequency : ±0.3Hz
> Accuracy Ɵme (recovery Ɵme, trip delay, power on delay) :
±5% of seƫng ±200ms
> Size : 35 X 90mm
9
PROTECTION RELAYS
DIN RAIL MOUNTING

> Current ProtecƟon Relay


Picture DescripƟon FuncƟon Type Price (Rp)
Digital Current ProtecƟon Relay • ProtecƟon :
> Input connecƟon :1Ɍ/2wire, with CT > Under current
> OperaƟng Voltage : 230VAC > Over current
> Output contact : 1 x 1 C/O (SPDT) • Monitoring in 1Ɍ system
raƟng : NO/5A, NC/3A, 250VAC • True RMS meansurement
> Trip seƫng : • Power ON delay 900CPR-1 720,000
• Under current : 0 - 999A • Trip Ɵme delay
• Over current : 0.5 - 1.19kA • Recovery Ɵme delay
> Trip Ɵme seƫng : • Adjustable switching hysteresis
• Power On Delay : 0 - 99.9s • One alarm relays with NC/NC
• Trip Ɵme delay : 0 - 99.9s
• Recovery Ɵme delay :0 - 99.9s
• Response Ɵme : < 200ms
> Accuracy :
• Current : ±1% of seƫng 2 digits
• Time (recovery Ɵme, trip delay, power on delay) :
±5% of seƫng 2 digits
> Size : 35 X 90mm

Digital Current ProtecƟon Relay • ProtecƟon :


> Input connecƟon : 3Ɍ/4Wire, 3Ɍ/3Wire, 1Ɍ/2wire, with CT > Under current
> OperaƟng Voltage : 230VAC / 110VAC > Over current
> Output contact : 1 x 1 C/O (SPDT) > Asymmetry current for 3Ɍ 900CPR-3 850,000
raƟng : NO/5A, NC/3A, 250VAC • Monitoring in 1Ɍ and 3Ɍ system
> Trip seƫng : • True RMS meansurement
• Under current : 0 - 999A • Power ON delay
• Over current : 0.5 - 1.19kA • Trip Ɵme delay
• Current asymmetry : 5 - 99.9% • Recovery Ɵme delay
> Trip Ɵme seƫng : • Adjustable switching hysteresis
• Power On Delay : 0 - 99.9s • One alarm relays with NC/NC
• Trip Ɵme delay : 0 - 99.9s
• Recovery Ɵme delay :0 - 99.9s
• Response Ɵme : < 200ms
> Accuracy :
• Current : ±1% of seƫng 2 digits
• Time (recovery Ɵme, trip delay, power on delay) :
±5% of seƫng 2 digits
> Size : 35 X 90mm

10
PROTECTION RELAYS
DIN RAIL MOUNTING

> Earth Leakage ProtecƟon Relay


Picture DescripƟon FuncƟon Type Price (Rp)
Analog Earth Leakage Relay • ProtecƟon earth leakage current
> Input connecƟon : 3Ɍ/4Wire & 1Ɍ/2wire • Leakage current monitoring in
> OperaƟng Voltage : 230VAC, 50/60Hz 1Ɍ and 3Ɍ system
> SensiƟvity (ѐI) & Time Delay (ѐt) adjustable • CBCT open circuit indicaƟon
> Trip seƫng : • Test and reset funcƟon ELRA2M2 750,000
• Leakage current : 30mA - 30A
> Size : 35 X 90mm

Digital Earth Leakage Relay • ProtecƟon earth leakage current


> Input connecƟon : 3Ɍ/4Wire, 3Ɍ/3Wire, 1Ɍ/2wire • Leakage current monitoring in
> OperaƟng Voltage : 230VAC / 110VAC 1Ɍ and 3Ɍ system
> Output contact : 2 x 1 C/O (SPDT) • True RMS meansurement 900ERL-2 1,100,000
raƟng : NO/5A, NC/3A, 250VAC • CBCT connecƟon monitoring
> Trip seƫng : • Power ON delay
• Leakage current : 10mA - 30A • Trip Ɵme delay
• Pre alarm : 50 - 100% of leakage current seƫng • Recovery Ɵme delay
> Trip Ɵme seƫng : • Adjustable switching hysteresis
• Power On Delay : 0.5 - 99.9s • Test and reset via front / remote
• Trip Ɵme delay : 0 - 99.9s • Two separate alarm relays with NC/NC
• Recovery Ɵme delay : 0 - 99.9s
• Response Ɵme : < 30ms (if trip current ш 5 x set value)
< 50ms (if trip current ш 1 x set value)
> Accuracy :
• Current : ±5% of seƫng 2 digits
• Time delays : ±5% of seƫng ±100ms
> Size : 35 X 90mm

Analog Earth Leakage Relay • ProtecƟon earth leakage current


> Input connecƟon : 3Ɍ/4Wire, 3Ɍ/3Wire, 1Ɍ/2wire • Monitors true RMS earth fault current
> OperaƟng Voltage : 230VAC, 50/60Hz • Inbuilt CBCT ELCTR35 call
> Trip seƫng : • Test and reset funcƟon
• Leakage current : 75% of 30mA or 300mA
> Size : 74 X 105mm

> Zero CT For Earth Leakage Relay (CBCT)


Size
Picture Type CT RATIO Price (Rp)
(Inner diameter)

1200:1 430,000
35mm CBCT-35
1000:1 235,000

1200:1 490,000
70mm CBCT-70
1000:1 340,000

1200:1 840,000
120mm CBCT-120
1000:1 880,000

11
PROTECTION RELAYS
DIN RAIL MOUNTING

> Earth Fault ProtecƟon Relay


Picture DescripƟon FuncƟon Type Price (Rp)
Digital Earth Fault Relay • ProtecƟon earth fault current
> Input connecƟon : 3Ɍ/4Wire, 3Ɍ/3Wire, 1Ɍ/2wire • Earth fault current monitoring in
> OperaƟng Voltage : 85 - 270VAC/DC, 50/60Hz 1Ɍ and 3Ɍ system 900ERF-2 1,100,000
> Trip seƫng : • RMS value measurements (AC)
• Alarm relays with NO and NC
• Up to 80% of MCCB frame raƟng
operaƟon selectable
> Size : 35 X 90mm

> Motor ProtecƟon Relay


Picture DescripƟon FuncƟon Type Price (Rp)
Motor ProtecƟon Relay • Single phase
> Input connecƟon : 3Ɍ / 3Wire • Phase unbalance
> OperaƟng Voltage : 230VAC, 50/60Hz • Phase sequence MPR-3M-2-230V call
> Trip Ɵme seƫng : • Under current trip
• Single phase : 5 sec • Over current trip
• Phase unbalance : 5 sec
• Phase sequence u : 5 sec
• Over load trip as per graph 1
• Under load trip : 5 sec
> Size : 52.5 X 90mm

> Water Level Controller


Picture DescripƟon FuncƟon Type Price (Rp)
Water Level Control • Used for drain and Įll cotrol
> OperaƟng Voltage : 85 - 270VAC, 50/60Hz
> Output contact : 1 C/O (SPDT) WLCA2M2 545,000
> Size : 35 X 90mm

> Weekly Timers


Picture DescripƟon Type Price (Rp)
Weekly Ɵmer
> OperaƟng Voltage : 220VAC, 50/60Hz
> Output contact : 1 C/O (SPDT) TS2M1-1 540,000
> Contact RaƟng : 16A / 250VAC
> 50 ON - OFF Step per day
> Size : 35 X 90mm

12
TIMERS
DIN RAIL MOUNTING

> Analog Timers


Picture DescripƟon Type Price (Rp)
• 13 FuncƟon, 10 Ɵme range
• Modes : A, B, C, Ci, D, E, F, H, I, J, K, Ai, Bi
• Time range : 0.1-1s, 0.3-3s, 1-10s, 3-30s,
0.1-1m, 0.3-3m, 1-10m, 3-30m, 0.1-1hr, 0.3-3hr 600XU 450,000
• Output contact : 1 C/O (SPDT)
raƟng : NO/5A, NC/3A, 250VAC
• Input voltage : 20-240VAC / 12-240VDC, 50/60Hz
• Size : 17.5 X 90 X 60mm

• Single FuncƟon, 10 Ɵme range


• Modes : On Delay
• Time range : 0.1-1s, 0.3-3s, 1-10s, 3-30s,
0.1-1m, 0.3-3m, 1-10m, 3-30m, 0.1-1hr, 0.3-3hr
• Output contact : 1 C/O (SPDT) 600ST 347,000
raƟng : NO/5A, NC/3A, 250VAC
• Input voltage : 240VAC, 50/60Hz
• Size : 17.5 X 90 X 60mm

• 2 FuncƟon, 12 Ɵme range, Universal voltage


• Modes : On Delay / Interval
• Time range : 1 / 3 / 10 / 30 sec / min / hr
• Output contact : 2 C/O (DPDT) 800XU 450,000
• Input voltage : 20-240VAC / 12-240VDC, 50/60Hz
• Size : 22.5 X 75 X 101mm

• 2 FuncƟon, 8 Ɵme range, Universal voltage


• Modes : On Delay / Interval
• Time range : 3 / 10 / 30 / 60 sec / min
• Output contact : 2 C/O (DPDT) 800XA 350,000
• Input voltage : 20-240VAC / 12-240VDC, 50/60Hz
• Size : 22.5 X 75 X 101mm

• 2 FuncƟon, 8 Ɵme range, dual voltage


• Modes : On Delay / Interval
• Time range : 3 / 10 / 30 / 60 sec / min
• Output contact : 1 C/O (SPDT) 800SQ-A 260,000
• Input voltage : 230-230VAC & 24VAC/DC, 50/60Hz
• Size : 22.5 X 75 X 101mm

Modes : A (On delay), B (Interval), C (Repeat Cycle Equal OFF Įrst), Ci (Repeat Cycle Equal ON Įrst),
D (Pulse Output 500ms Įxed), E (Delay on break), F (Delay on make/Delay on break),
H (Interval aŌer break), I (Single short), J (Retriggerable single short), K (Latching relay),
Ai (Delay on make with totalise), Bi (Interval with totalise).
13
TIMERS
DIN RAIL MOUNTING

> Analog Timers


Picture DescripƟon Type Price (Rp)
• Single FuncƟon, Single Ɵme range
• Modes : On delay
• Time range : 30sec and 60sec 800S - 30S 245,000
• Output contact : 1 C/O (SPDT)
• Input voltage : 230VAC/50Hz 800S - 60S 245,000
• Size : 22.5 X 75 X 101mm

• Single FuncƟon, Single Ɵme range


• Modes : True power OFF delay 800POD - 60S 865,000
• Time range : 60sec and 180sec
• Output contact : 2 C/O (DPDT) 800POD - 180S 865,000
• Input voltage : 110 - 240VAC/DC, 50/60Hz
• Size : 22.5 X 75 X 101mm

• Cyclic with unequal ON & OFF Ɵme


• Modes : Asymmetrical cyclic ON Įrst or OFF Įrst
• Time range : 1 / 10 /sec/min/hr for both ON & OFF Ɵme
• Output contact : 2 C/O (DPDT)
• Input voltage : 20-240VAC / 12-240VDC, 50Hz 800XC 500,000
• Size : 22.5 X 75 X 101mm

• FuncƟon for Forward - Pause - Reverse


• Modes : Forward - Pause - Reverse
• Time range : ON Ɵme : 1/2/4/8 min
Pause Ɵme : 10/20/40/80 Sec 800XMR 600,000
• Output contact : 1 C/O each for forward & Reverse
• Input voltage : 20-240VAC / 12-240VDC, 50/60Hz
• Size : 22.5 X 75 X 101mm

• FuncƟon for Star - Delta Ɵmer


• Modes : Star - Delta
• Time range : Run up Ɵme range : 30/60 sec
Change over Ɵme : 50/100 sec 800SD-2 330,000
• Output contact : 1 C/O relay each for star - delta
• Input voltage : 230VAC, 50HZ
• Size : 22.5 X 75 X 101mm

14
TIMERS
PIN PLUG MOUNTING

> Analog Timers


Picture DescripƟon Type Price (Rp)
• 2 FuncƟon, 12 Ɵme range, Universal voltage
• Modes : On delay / Interval
• Time range : 1 / 3 / 10 / 30 sec / min / hr 55XU-P8 460,000
• Output contact : 2 C/O (DPDT)
• Input voltage : 20-240VAC / 12-240VDC, 50/60Hz
• Size : 48 X 48mm

• 2 FuncƟon, 8 Ɵme range, dual voltage


• Modes : On Delay / Interval
• Time range : 3 / 10 / 30 / 60 sec / min 55ES-P8 280,000
• Output contact : 1 C/O (SPDT)
• Input voltage : 230-230VAC & 24VAC/DC, 50/60Hz
• Size : 48 X 48mm

• 2 FuncƟon, 8 Ɵme range


• Modes : On Delay / Interval
• Time range : 3 / 10 / 30 / 60 sec / min
• Output contact : 2 C/O (DPDT) 55Q-P8 350,000
• Input voltage : 230VAC/ 50Hz
• Size : 48 X 48mm

> Digital Timers ( Panel MounƟng )


Picture DescripƟon Type Price (Rp)
• 2 FuncƟon, 3 digits LED
• Modes : On delay / Interval
• Time range : 9.99/99.9/999sec, 99.9/999min, 99,9hr XT56N 900,000
• Output contact : 2 C/O (DPDT)
• Input voltage : 97 - 270V AC/DC, 50/60Hz
• Size : 48 X 48mm

• 4 FuncƟon, 3 digits LED


• Modes : On delay / Interval / Cyclic ON or OFF Įrst
• Time range : 9.99/99.9/999sec, 9.59min : sec, XT546 750,000
99.9/999min, 9.59hr : min, 99.9/999hr
• Output contact : 2 C/O (DPDT)
• Input voltage : 85 - 270V AC/DC, 50/60Hz
• Size : 48 X 48mm

15
RATE INDICATORS
PANEL MOUNTING

Picture DescripƟon Size Type Price (Rp)


• Time Totaliser
• LCD display , 8 digits LT945V 315,000
• Time range : 999999.99 hr 48 X 48
• Input Type : a) 24 - 260 VAC LT945C 315,000
b) Contact
• Input voltage : baƩery powered

• RPM Meters 48 X 48 RC5100 775,000


• LED display , 4 digits (sensor PNP)
• Range : 4.00 to 9999 RPM
• Input Speed : 4 to 9999 pulses per minute 72 X 72 RC2100 775,000
• Input Type : Voltage pluse 3 - 30VDC (sensor PNP/NPN)
• Input voltage : 90 - 270 V AC/DC
• Sensor type : PNP / NPN 48 X 96 RC100 845,000
(sensor PNP)
• Counter & Totaliser
• LED display , 6 digits
• Range : 999999 counts 36 X 72 XC410 690,000
• Input Speed : a) 0 to 20Hz, b) 0 to 1kHz
• Input Type : Voltage pluse 3 - 30VDC
• Input voltage : 90 - 270 V AC/DC, 24VAC/DC
• Sensor type : PNP, NPN

• Counter
• LCD display , 8 digits
• Range : 99999999 counts 24 X 48 LXC900V 315,000
• Input Speed : a) 14Hz, b) 100Hz
• Input Type : 24 - 260 VAC
• Input voltage : baƩery powered

• Counter with setpoint


• LCD display , 4 digits
• Modes : On delay / Interval delay / Auto reset
• Range : 9999 counts 72 X 72 XC22B-4 1,150,000
• Input Speed : a) 0 - 30Hz, b) 0 - 5kHz
• Input Type : Voltage pluse 3 - 30VDC
• Input voltage : 230VAC, 50Hz
• Sensor type : PNP, NPN
• Output contact : 2 C/O (DPDT)

16
TEMPERATURE CONTROLS
PANEL MOUNTING

> Digital Temperature Controls


Picture DescripƟon Type Price (Rp)
• LED Single display , 3 digits
• Single set point
• Control Modes : Auto tune /self tune PID or ON-OFF TC513BX 440,000
• Input sensor type :
> Thermocouple ( J,K,T,R,S )
> RTD ( PT100 )
• Output Control : Relay / SSR
• Input voltage : 85 - 270 V AC/DC, 50/60Hz
• Size : 48 X 48 X 76mm

• LED Dual display , 3 digits


• Single set point
• Control Modes : Auto tune /self tune PID or ON-OFF
• Input sensor type : TC533BX 520,000
> Thermocouple ( J,K,T,R,S )
> RTD ( PT100 )
• Output Control : Relay / SSR
• Input voltage : 85 - 270 V AC/DC
• Size : 48 X 48 X 76mm

• LED Dual display , 4 digits


• Dual set point
• Special funcƟons : Heat-Cool PID, Dwell Ɵmer
• Control Modes : Auto tune /self tune PID or ON-OFF
• Input sensor type : TC544B 650,000
> Thermocouple ( J,K,T,R,S )
> RTD ( PT100 )
• Output Control : Relay / SSR
• Auxiliary output : 1 (Relay)
• Alarm modes : DeviaƟon, absolute
• Input voltage : 85 - 270 V AC/DC, 50/60Hz
• Size : 48 X 48 X 76mm

• LED Dual display , 4 digits


• Single set point
• Control Modes : Auto tune /self tune PID or ON-OFF
• Input sensor type : TC538BX 550,000
> Thermocouple ( J,K,T,R,S )
> RTD ( PT100 )
• Output Control : Relay / SSR
• Input voltage : 85 - 270 V AC/DC, 50/60Hz
• Size : 48 X 48 X 76mm

17
TEMPERATURE CONTROLS
PANEL MOUNTING

> Digital Temperature Controls


Picture DescripƟon Type Output Price (Rp)
• Advanced PID controller, Covers most applicaƟons PID500-0-0-00 Out 1 : relay 1,480,000
• LED Dual display , 4 digits Out 2 : relay
• Fuatures :
> Universal input, Auto tune, Selectable lower display, PID500-1-0-00 Out 1 : SSR 1,580,000
> Single point ramp-soak, Heat-Cool PID, SoŌ start, Auto/Manual mode Out 2 : relay
• Input sensor type :
> Thermocouple ( J,K,T,R,S,C,E,B,N,L,U,W ) PID500-2-0-00 Out 1 : 4-20mA 1,580,000
PID500 > RTD ( PT100 ) Out 2 : relay
( size : 48X48X110 ) > Singnal Input (DC) : -5 to 56mV, 0 - 10V, 0 - 20mA
• Output Control : PID500-3-0-00 Out 1 : 0-10V 1,550,000
> Relay or SSR Out 2 : relay
> Current : 0/4 to 20mA ( max load 500E )
> Voltage : 0 - 50/10VDC ( max load 10K )
• Auxiliary output : 2 (Relay or SSR drive voltage) PID110-0-0-00 Out 1 : relay 1,350,000
• Mode : Set poit or Alarm mode Out 2 : relay
• Alarm modes : DeviaƟon, Absolute, Hight, Low, Band, Sensr break
• Control acƟon : PID or ON-OFF PID110-1-0-00 Out 1 : SSR 1,510,000
• Input voltage : 85 - 270 V AC/DC, 50/60Hz Out 2 : relay

PID110-2-0-00 Out 1 : 4-20mA 1,750,000


Out 2 : relay
PID110
( size : 48X98X85 ) PID110-3-0-00 Out 1 : 0-10V 1,657,000
Out 2 : relay

> Cooling Controlles


Picture DescripƟon Type Price (Rp)
• Chiller Controller, Deforst management, Hight & Low alarm
• LED Single display , 3 digits
• Display oīset : -19.9 to 20.0 ϶C/F CH403-1 400,000
• Single set point
• Control Modes : ON-OFF
• Input sensor type : NTC
• Output Control : Relay
• Alarm output : 2 (Relay or SSR )
• Input voltage : 85 - 270 V AC/DC, 50/60Hz
• Relay acƟon : Heat & Cool mode
• Size : 36 X 72mm

18

You might also like