September 28, 2000                              DN-1271  I-307
302 Series
                                                                                  Rate-Anticipation Heat Detectors
                                                                                          Section: Conventional Initiating Devices
GENERAL
                                                                                                                              California
The Thermotech 302 Series rate-anticipation heat detec-                                                                       State Fire
tors operate within a controlled range of two to three de-                                                                    Marshal
grees of their set points, regardless of the speed or rate of                                                                 7270-0021:001
temperature rise. These detectors are available in either
135°F (57.2°C) or 194°F (90°C) ratings.
The 302 Series are normally-open devices designed es-                                      S539
pecially for fire detection and alarm systems.                                            E35018A
                                                                                     (EPM model only)
FEATURES
                                                                                                                 Approved
 Immediate response. The 302 Series activate when-                                                               (Except EPM)
  ever ambient air temperature reaches a detectors set-
  ting, eliminating the thermal time lag inherent in conven-
  tional heat detectors.
 Eliminates false alarms. The 302 Series do
  not respond to momentary temperature fluctua-
  tions below the selected temperature.
 Universal application. The 302 Series can be
  used in all areas for any type of occupancy.
                                                                                       Model 302
 Self-restoring.                                                                                                    Model 302-AW
 Hermetically sealed, shock resistant, corrosion
  resistant, and tamper-proof.
PRINCIPLES OF OPERATION
The 302 Series rate-anticipation heat detectors
respond and activate the fire alarm immediately
whenever the ambient temperature reaches the
preset temperature setting. Under rapid heat rise
conditions, the rate-anticipation feature enables                      Model 302-EPM                                     Model 302-ET
the detector to respond one to three degrees
ahead of the setting. At the same time, however,
it does not respond to momentary temperature
fluctuations below the selected protection level,
thus eliminating false alarms. When temperature
drops back down below the protection level, the
detector automatically resets itself.                                                                Model 302-H
DIMENSIONS (Model 302)
                                                                                                                                      1271pho1.jpg
Total overall length: 4-1/8" (10.48 cm).
Base diameter: 2" (5.08 cm).
ELECTRICAL RATINGS                                                           APPLICATION INFORMATION
Voltage              Current                                                 302 Series detector have a smooth ceiling UL rating of 50'
6  125 VAC          5 amps                                                  x 50' (15.24 x 15.24 meters) and are the only type of heat
                                                                             detectors having such a rating on both fixed temperature
6  25 VDC           1 amp                                                   and rate anticipation. The 302-H is designed for horizontal
125 VDC              0.5 amp                                                 mounting and is UL rated for 40' x 40' (12.19 x 12.19
                                                                             meters).
  This document is not intended to be used for installation purposes. We try to keep our
  product information up-to-date and accurate. We cannot cover all specific applications or
  anticipate all requirements. All specifications are subject to change without notice. For
  more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118
                                     12 Clintonville Road, Northford, Connecticut 06472
                                                                                                               DN-1271  09/28/00  Page 1 of 2
PRODUCT LINE INFORMATION
           Thermotech Model 302 Series Rate-Anticipation Heat Detectors
  MODEL NUMBER                                         DESCRIPTION                          R E FE R TO
 302-135                 135°F Interior Vertical Mounting.
                                                                                         Note 1 below.
 302-194                 194°F Interior Vertical Mounting.
 302-AW-135              135°F All-Weather Vertical Mounting.
                                                                                         Note 2 below.
 302-AW-194              194°F All-Weather Vertical Mounting.
 302-ET-135              135°F All-Weather Vertical Mounting.
                                                                                         Note 3 below.
 302-ET-194              194°F All-Weather Vertical Mounting.
 302-H-135               135°F Interior Horizontal Mounting.
                                                                                         Note 4 below.
 302-H-194               194°F Interior Horizontal Mounting.
 302-EPM-135             135°F Explosion-Proof Mounting.
                                                                                         Note 5 below.
 302-EPM-194             194°F Explosion-Proof Mounting.
 AP-P                    Decorative white plastic adaptor plate for mounting 302
                         and 302-AW to 4" outlet box.
                                                                                                      1271t1.tbl
                                                                 Note 1:   For interior mounting in any atmosphere that is com-
                                        1271dia1.tif
                                                                           patible with terminal-screw-type connections. UL
                                                                           rating 50' x 50' (15.24 x 15.24 meters).
                                                                 Note 2:   Humitically sealed for moisture-proof or dust-proof
                                                                           installations. Requires no special backbox when the
                                                                           all-weather leads are properly spliced to THW or
                                                                           equivalent type wire.
                                                                 Note 3:   Humitically sealed for moisture-proof or dust-proof
                                                                           installations. Requires no special backbox. Has
                                                                           plastic hexagonal wrench grip bushing with 1/2 (1.27
                                                                           cm) conduit threads for attachment to threaded hub
                                                                           cover, or any outlet box.
                                                                 Note 4:   Same as model 302 except designed for horizontal
                                                                           mounting. UL rating 40 x 40 (12.19 x 12.19 meters).
                                                                 Note 5:   Explosion-proof for installation in hazardous locations.
                                                                           Has hexagonal wrench-grip bushing with 1/2 (1.27
                                                                           cm) conduit threads for attachment to threaded hub
                                                                           cover of Series JL fixture fitting as manufactured by
                                                                           Killark Electric Co., or equal.
  Cut-Away View, ACTUAL SIZE