Concrete Frame Design Summary

This document summarizes the design of a concrete column (C6) according to IS 456:2000. The column is 12x12 cm in cross-section, 2.844m long, and located on the 1st floor. It was designed for an axial load of 570.5 kN and bending moments of 23.6 and -53.4 kN-m. Reinforcement of 1511 mm2 (1.63% of cross-section) was required. Shear demands of 41.6 and 39.3 kN were less than the column's shear capacity. Joint shear checks were not applicable. Bending moment-to-shear ratios were also within code limits.

Uploaded by

Abinash Neupane
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
80 views2 pages

Concrete Frame Design Summary

This document summarizes the design of a concrete column (C6) according to IS 456:2000. The column is 12x12 cm in cross-section, 2.844m long, and located on the 1st floor. It was designed for an axial load of 570.5 kN and bending moments of 23.6 and -53.4 kN-m. Reinforcement of 1511 mm2 (1.63% of cross-section) was required. Shear demands of 41.6 and 39.3 kN were less than the column's shear capacity. Joint shear checks were not applicable. Bending moment-to-shear ratios were also within code limits.

Uploaded by

Abinash Neupane
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

ETABS 2013 13.1.

5 License #*1DDPUVNRG45RVCX

ETABS 2013 Concrete Frame Design


IS 456:2000 Column Section Design

Column Element Details Type: Ductile Frame (Summary)

Level Element Section ID Combo ID Station Loc Length (mm) LLRF


1F C6 C-12X12 DL+1.25RSX 0 2844.8 0.616

Section Properties

b (mm) h (mm) dc (mm) Cover (Torsion) (mm)


304.8 304.8 56 30

Material Properties

Ec (MPa) fck (MPa) Lt.Wt Factor (Unitless) fy (MPa) fys (MPa)


22360.68 20 1 500 500

Design Code Parameters

ɣC ɣS
1.5 1.15

Axial Force and Biaxial Moment Design For Pu , Mu2 , Mu3

Design Pu Design Mu2 Design Mu3 Minimum M2 Minimum M3 Rebar Area Rebar %
kN kN-m kN-m kN-m kN-m mm² %
570.5165 23.6339 -53.3954 11.4103 11.4103 1511 1.63

Axial Force and Biaxial Moment Factors

K Factor Length Initial Moment Additional Moment Minimum Moment


Unitless mm kN-m kN-m kN-m
Major Bend(M3) 0.757404 2489.2 -21.3582 0 11.4103
Minor Bend(M2) 0.742939 2489.2 9.4536 0 11.4103

Shear Design for Vu2 , Vu3

Shear Vu Shear Vc Shear Vs Shear Vp Rebar Asv /s


kN kN kN kN mm²/m
Major, Vu2 41.6095 70.4167 30.3333 55.5333 337.85
Minor, Vu3 39.3182 70.4167 30.3333 39.3182 337.85

Joint Shear Check/Design

Kapan Residence DYNAMIC.EDB Page 1 of 2 11/1/2014


ETABS 2013 13.1.5 License #*1DDPUVNRG45RVCX

Joint Shear Shear Shear Shear Joint Shear


Force VTop Vu,Tot Vc Area Ratio
kN kN kN kN cm² Unitless
Major Shear, Vu2 N/A N/A N/A N/A N/A N/A
Minor Shear, Vu3 N/A N/A N/A N/A N/A N/A

(1.1) Beam/Column Capacity Ratio

Major Ratio Minor Ratio


N/A N/A

Additional Moment Reduction Factor k (IS 39.7.1.1)

Ag Asc Puz Pb Pu k
cm² cm² kN kN kN Unitless
929 15.1 1402.623 312.1048 570.5165 0.763038

Additional Moment (IS 39.7.1)

Consider Length Section KL/Depth KL/Depth KL/Depth Ma


Ma Factor Depth (mm) Ratio Limit Exceeded Moment (kN-m)
Major Bending (M3 ) Yes 0.875 304.8 6.185 12 No 0
Minor Bending (M2 ) Yes 0.875 304.8 6.067 12 No 0

Notes:

N/A: Not Applicable

N/C: Not Calculated

N/N: Not Needed

Kapan Residence DYNAMIC.EDB Page 2 of 2 11/1/2014