SAS Foundation
SAS Foundation
DESIGN DATA
Tank Data:
         Empty weight =                    2,571 kgs
         Operating weight =                6,791 kgs (80%Volumn)
         Test weight =                    11,520 kgs
         thickness,t =                      12.0 mm
         Basic daimeter =                     1.7 m.
         Length of vessel, Lv               17.2 m.
         Height from Center of Vessel to Top of Wall Pier, Cb =                  1.07 m.
         Length of between saddles, Ls =                    2.2 m.
          Maximum design temperature =                                50 oC or   122 oF
          Vessel Material =             carbon steel
          Bolts:
          Bolt spacing:
          Saddle:
                            long by                   2.72 m.
                            wide by                   0.55 m.
Design Criteria:
          Concrete: f'c =                             210 ksc
          Reinforceing: fy =                         2500 ksc
          Soil unit weight: g=                       8000 ksm
          Wind loads:ASCE 7-05
          Earthquake loads:ASCE7-05
DETERMINE LOADS
Empty,Operarting,and Test Loads
          เผผผื่อนนนน้ำหนนัก piping support                           10 %
          Total empty load, De =                               2,828.10 kgs.
          Total operating load, Do =                           7,470.10 kgs.
          Total test load, Dt =                               12,672.00 kgs.
Tranverse Moment from Pipe Eccentricity
             Eccentricity =                     1.30 ft
             Empty transverse moment per pier, MTe =                                  167.12 kg-m
             Operating transverse moment per pier, MTo =                              441.42 kg-m
             Test transverse moment per pier, MTt =                                   748.80 kg-m
Wind Loads:
        Vessel wind is applied st the center of the vessel
        Cf_round =          0.7                    Gf =                                 0.85
             Cf_flat=                  1.8                       qz =                  20.89 psf
SEISMIC LOADS
        Site Location
                        ต.ททน้ำชน้ำช้ ง อ.สวทน้ำงววีระวงศศ์ จ.ออุบลรน้ำชธน้ำนวี
        คทน้ำควน้ำมเรท งตอบสนองเชสิงสเปกตรนัมทวีผื่คน้ำบสนันน Ss =                      0.08 g
        คทน้ำควน้ำมเรท งตอบสนองเชสิงสเปกตรนัมทวีผื่คน้ำบสนันน S1 =                     0.083 g
        ชนันนดสินประเภท D
        สนัมประสสิ ทธสิธ ชนันนดสิน                         Fa =                 1.6     Fv =         2.4
          SDS =(2/3)FaSs =                  0.0853
          SD1 =(2/3)FVS1 =                  0.1328
          Fundamental period, T =                    0.021153141 sec.
          Importance Factor, I =              1.25
                            Sa =         0.057335 g
                             R=                2.9
          สนัมประสสิ ทธสิธ ผลตอบสนองแรงแผทนดสินไหว, Cs = Sa/(R/I) =              0.02471336 g
          Vessel Load:
                      Empty: Ee =0.30.SDS.I.De =                         90.50 kg.
                     Operating: Eo =0.30.SDS.I.Do =                     239.04 kg.
          Wall Pier Seismic Loads
                     weight of wall pier above footing, Wtpierb = (1/2).(Hf-Hm)Lpier.Wpier.gconc
                                                                        3,000.00 kgs.
                     Lateral force of wall pier, Ewallpier = Cs.Wtpier=                 74.14 kg
Thermal Force:
         m=                  0.6
         Operating load, Po =           3,735.05 kgs.            per pier
         Ff = m(Po) =                   2,241.03 kgs.            per pier
         Assume pier size is long by                                                     2.5 m.
                                 wide by                                                 0.5 m.
                                 high by                                                   2 m.
          Moment of inertia, I = 2,604,166.67 cm4
          Modulus of elasticity,Ec =                 218,819.79 ksc
          Thermal expansion coefficient for carbon steel at                              122 F
          Thermal growth between e saddles, D = Ce.Ls(Temp-70) =                     0.07436 cm
          Fd =3DEI/2H3 =                 7,945.04 kgs.           OK.
          Tf := min(Ff, Fd) =           10,304.91 kgs.
DESIGN ELEMENTS
        Size Steel Bearing Plate
                     Steel bearing plate dimension:
                                  Width =                        50 cm.
                                  Length =                      250 cm.
                     Check bearing stress (test load case) :
                                  P=                     6,336.00 kg             per pier
                                  Allowable bearing stress. Fp =                 0.35f'c(A2/A1)^0.5 < 0.70 f'c
                                  Assume pier section               length
                                  area of pier, A2 =                       12500 cm2
                                  area of steel bearing plate, A1 =                   12,500 cm2
                                     Fp = 0.35f'c=            73.5 ksc
         หนทวยแรงตช้น้ำนทวีผื่เกสิดขขนน,fp =P/(NB) =         0.51 kg/cm2        < Fp OK
         Fb ของแผทนเหลล็ก =0.75Fy =                          1800 kg/cm2
                  0.95b =                         237.5 cm
                  0.95d                            47.5 cm
                  m=N-0.95d/2 =                               1.25 cm.
                  n=B-0.95bf/2 =                              6.25 cm.
                     t =(3fpn2/Fb)^0.5 =                  0.181659021 cm. or               4 mm.
                     ใชช้แผทนเหลล็กเททน้ำกบนั ควน้ำมหนน้ำ                                  6 mm.
Flexural Design
          Maximum moment in the wall pier,Mmax =Vmax.(Hf-Hm) =                    20,609.82 kg-m
          fc' =          210 ksc
          fc =        78.750 ksc ใชช้             79
          fy =         3000 ksc
          fs =         1500
          Es =      2040000
         Ec =15,100·fc'^0.5 =       218,819.79 ksc
         n = Es/Ec =            9
         k=               0.322
         j=               0.893
         R=               11.34 ksc
                      Mc =Rbd =
                              2
                                    5,639,571.22 kg-m. > Mmax OK.
         As   1
                  =   Mmax/fs.jd=     34.51      cm  2
                                                             each face
         Try                20        DB              16       mm As =   40.19 cm2
         Approximate spacing, S =( Lpier-2Cc-db)/(No. ofbar-1) =            12.55 cm
FOOTING DESIGN
       Assume thickness of footing,Hm =                     0.3 m.
       COMB.1 Operating
                 P1max =             3,735.05   kg
                 H1 =               10,304.91   kg
                 Moment at bottom of footing
                 Mtotal =H1.Hpier=                   20,609.82 kg-m
       COMB.4 Empty+Seismic
                 P4max =             1,103.71   kg
                 H4 =                  219.23   kg
                 Moment at bottom of footing
                 Mtotal =H4.Hpier=                       438.46 kg-m
v=                  40 m/s
q = 0.5*ρ*v2=                                 1 kPa =                 20.8854342331
ODeff := if(OD < 3ft , 2×OD, if(OD < 4.5ft , 1.8×OD, if(OD <6.5ft , 1.7×OD, if(OD< 8.5ft , 1.6×OD, 1.5×OD))))
          หน้ำคทน้ำ Fa,Fv
          Ss คทน้ำนอช้ ย Ss คทน้ำทวีผื่ตอช้ งกน้ำร Ssคทน้ำมน้ำก
                    0.75                         0.08             1
Fa                    1.2                     1.468             1.1
คนน้ำนวณกน้ำรเคลผผื่อนตนัวของถนัง
             y= (Wol3)/(3EIm)                Wo =                 7,470.10 kgs
                                             l=                        100 cm.
                                             E=                 218,819.79 ksc
                                           I=                 2,604,166.67 cm4
             y=               0.0043696816 cm
             T =0.32(y^0.5)
Hpier = Hf-Hm =                            2 m. ระยะจน้ำกดช้น้ำนบน wall ถขง ดช้น้ำนบนของ footimng
                                         122 F
                                    0.000078 in/ft/F
                                7.217847769 Ls(ft)
Thermal Force:
         m=                0.1
         Operating load, Po =        184.25 kips         per pier
         Ff = m(Po) =                18.425 kips         per pier
         Assume pier is        long by                12 ft          2 inches
                               wide by                 0 ft         14 inches
                               high by                 0 ft         81 inches
          Moment of inertia, I = 33,385.33 inches4
          Modulus of elasticity,Ec =           3,605.00 ksi
          Thermal expansion coefficient for carbon steel at         500 F e =   0.0362
          Thermal growth between e saddles, D = ε L = 0.7964 inches
        T =3DEI/2H3 =               270.54 kips       OK.
DESIGN ELEMENTS
        Size Steel Bearing Plate
                   Steel bearing plate dimension:
                              Width =             2.5
                              Length = (saddle length)+2.5 cm. =
Check bearing stress (test load case) :
          P=                   216.7 kips    per pier
          Allowable bearing stress. Fp =     0.35f'c(A2/A1)^0.5 < 0.70 f'c
          Assume pier section length                                       width
          area of pier, A2 =               0
          area of steelbearing plate, A1 =            0
          Fp =
a. No slide plate (steel support on concrete) 0.60
b. Steel slide plate 0.40
c. Low-friction slide plate assemblies 0.05 to 0.20