Fire Detection
System
     (FDS)/VESDA
VESDA: Very Early Smoke
Detection & Alarm System
Fire Detection System:
   Purpose of installation:
   To perform brake application &
   announcement for passengers, in case
   of Fire or smoke inside the coach.
Fire Detection System:
  There are different makes of FDS
  systems which are currently running in
  ANVT based Primary Trains.
  1. M/s Sanrok Enterprises.
  2. M/s JK Exim
  3. M/s Tayal & Co.
  4. M/s Advance Hi-tech           4. Advance
   1. Sanrok   2. JK Exim   3. Tayal
                                        Hi-Tech
Fire Detection System:
  There are 2 electrical panels in Fire
  Detection system:
                                  Power
      Fire Panel
                               Supply Panel
   1. Detector & Aspirator   1. SMPS
   2. Public                 2. Charging Unit
      Announcement           3. Batteries (02 Nos.)
      Module
   3. Brake Module
Fire Detection System:
  There are 2 electrical panels in Fire
  Detection system:
                                          110 V
                                          DC
                                          input
                                                  1      2
                             24 V
       1                      DC
                            output
                  2   3
                                                  3
  1. Detector & Aspirator
                                     1. SMPS
  2. Public Announcement
                                     2. Charging Unit
     Module
                                     3. Batteries (02 Nos.)
  3. Brake Module
Smoke Testing Procedure: After exposure of smoke, system
will response as mentioned below:
1. Alert: Alert indication will glow.
2. Action: Action light along with Flasher light will glow.
3. Fire: Brake application will occur, brake indication light will
     glow, Brake valve indication lights will get OFF. Hooter will
     operate inside the coach.
4. After 55 sec of Brake Application, public announcement will
     occur inside the coach.
Fire Detection System:
 Maintenance activities:
 D-1/Trip Schedule:
 1. Visual Inspection of Fire Panel, it must be ON, if not
    check whether MCB is ON or not.
 2. Ensure 03 Green LEDs must glow in case of M/s
    Sanrok Make FDS system.
 D-2/Monthly Schedule:
 3. Check intactness of power supply input voltage from
    DC power supply to detector and output voltage
    from detector to other devices.
 4. Battery back up must be more than 18 Volts.
 5. Air flow value must be fn±20%, i.e. fn= Normalized
    air flow value
       If air flow value< fn-20%, then flush the pipeline
    with and check again.
       If more than Fn+20%, check intactness of the pipe
    & capillary network.
Fire Detection System:
   Maintenance activities:
   D-3/Monthly Schedule:
   Conduct smoke test by simulating smoke generation
      from any
   monthly source e.g. smoke generator at the farthest
   end from the system and verify detector performance as
   per maintenance manual.
   SS-1 Schedule:
   i) Clean the sampling points, sampling pipe and
   capillaries by vacuum cleaning
    ii) Replace any defective/malfunctioning parts and
   carry out smoke test.
   SS-2 Schedule:
   i) Complete testing of the system including replacement
   of must change items (i.e. filter & batteries).
 Fire Detection cum
Suppression System
       (FDSS)
e Detection cum Suppression System
 Purpose of installation & Components:
 •To detect, presence of smoke or heat inside the pantry or
 power car & activate the alarm buzzer.
 •To give the signal to cut off the power supply of DG set
 (power car) & electric hob (in pantry car) in case of heat
 alarm & activate suppression process.
 Fire Alarm
                              Display
 Smoke Alarm
                          Manual
                     Activation Switch   Nitrogen Cylinder   Water Cylinder
e Detection cum Suppression System
 Components of FDSS Panel:
                                 1. SMPS
                                 2. Charging Unit
                                 3. Nitrogen Module
                                 4. Batteries
                                 5. Nitrogen Valve
                                    Switch
                             6
                         3       6. Rely to shutdown
                                    DG set
                 5
                         2
   4                 1
e Detection cum Suppression System
 There are 3 types of detectors in
 FDSS system:
 1.   Smoke Detector- 04 Nos.
      2 Smoke detectors for 2 DG sets(1 for each)
      1 for guard area
      1 for Crew area                               Smoke Detector
 2.   Heat Detectors- 02 Nos.(1 for each DG set)
      Operating temperature- 90°C
 3.   LHD (Linear Heat Detector) Cable- located
      below the ceiling of DG area & Pantry area.
      Operating Temperature- 105°C
                                                     Heat Detector
Fire Detection System:
  Maintenance activities:
  D-1/Trip Schedule:
  1. Visual Inspection of Fire Panel, it must be ON, if not
     check whether MCB is ON or not.
  2. Ensure 02 Green LEDs- Power ON & Health,must glow
     in case of M/s Sanrok Make FDS system.
  3. Check Nitrogen Pressure: It must not be less than 150
     kg/cm2.
  4. Smoke & Heat Detectors must blink. RED light must
     not glow permanently.
  D-2/Monthly Schedule:
  5. Check Nitrogen Pressure: It must not be less than 150
     kg/cm2.
  6. Check physical condition of smoke & heat detectors, if
     required, clean it with soft cloth.
Fire Detection System:
   Maintenance activities:
   D-3/Monthly Schedule:
   i)   Carry out smoke detection test for point type smoke detector.
   ii) Check condition of pipe line. It must be securely clamped. Check
       the condition of nozzles.
   SS-1 Schedule:
   i)   Carry out heat detection test for point type heat detectors.
        System integrity at least up to activation signal of solenoid valve
        to be ensured.
   SS-2 Schedule:
            Complete testing of the system.
equent Issues with FDSS System :
1. Nitrogen Valve not connected:
    Possible Reasons:
    1. Nitrogen valve switch is OFF- open the panel & turn ON the
       switch.
    2. Nitrogen Valve wiring broken- Inform to Vesda Batch.
    3. Nitrogen module defective- Inform to Vesda Batch
equent Issues with FDSS System :
1. No supply in FDSS Panel:
   Possible Reasons:
   1. Main MCB is OFF in Electrical Panel- Switch ON the MCB from
      electrical panel.
   2. Display connector is disconnected – Open the FDSS panel &
      reconnect the connector.
   3. If problem not resolved, then inform to VESDA batch.