1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198
|
/*
* sssraid.h
*
* Home page of code is: http://www.smartmontools.org
*
* Copyright (C) 2022 3SNIC Inc.
*
* SPDX-License-Identifier: GPL-2.0-or-later
*/
#ifndef _SSSRAID_H_
#define _SSSRAID_H_
#include <stdint.h>
#define u8 uint8_t
#define u16 uint16_t
#define u32 uint32_t
#define u64 uint64_t
#define ADM_MAX_DATA_SIZE 0x1000U // 4096
#define ADM_SCSI_CDB_MAX_LEN 32
#define ADM_SCSI_CDB_SENSE_MAX_LEN 96
#define ADM_SCSI_CDB_SENSE_LEN32 32
#define ADM_CMD_SHOW_PDLIST 0x502 // 1282
#define ADM_CMD_SCSI_PASSTHROUGH 0x51e // 1310
#define BSG_APPEND_TIMEOUT_MS 600000
#define DEFAULT_CONMMAND_TIMEOUT_MS 180000
#define ADM_BSG_MSGCODE_SCSI_PTHRU 1
#define ADM_RAID_SET 0xc0
#define ADM_RAID_WRITE 0xc1
#define ADM_RAID_READ 0xc2
#define ADM_RAID_PARAM_WRITE 0xc3
#define ADM_RAID_READ_FROM_CQE 0xc4
// pdlist device type interface
enum adm_pdlist_intf {
ADM_DEVICE_TYPE_SAS = 1,
ADM_DEVICE_TYPE_EXP = 2,
ADM_DEVICE_TYPE_SATA = 8,
ADM_DEVICE_TYPE_PLANE = 9,
ADM_DEVICE_TYPE_NVME = 10,
ADM_DEVICE_TYPE_UNKNOW,
ADM_DEVICE_TYPE_BUTT
};
struct cmd_pdlist_idx {
u16 start_idx;
u16 count;
u32 rsvd;
};
struct cmd_pdlist_entry {
u16 enc_id;
u16 slot_id;
u8 interface;
u8 media_type;
u8 logi_type;
u8 logi_status;
u32 reserve[26];
};
#define CMD_PDS_MAX_NUM 256U
#define CMD_PDLIST_ONCE_NUM ((ADM_MAX_DATA_SIZE - 64) / sizeof(struct cmd_pdlist_entry))
struct cmd_show_pdlist {
u16 num;
u16 rsvd0;
u32 rsvd1[15];
struct cmd_pdlist_entry disks[CMD_PDLIST_ONCE_NUM];
};
struct multi_disk_location {
u16 enc_id;
u16 slot_id;
u16 did;
u8 flag;
u8 rsvd;
};
struct cmd_scsi_passthrough {
struct multi_disk_location loc;
u8 lun;
u8 cdb_len;
u8 sense_buffer_len;
u8 rsvd0;
u8 cdb[32];
u32 rsvd1;
u8 *sense_buffer;
};
struct sssraid_passthru_common_cmd {
u8 opcode;
u8 flags;
u16 rsvd0;
u32 nsid;
union {
struct {
u16 subopcode;
u16 rsvd1;
} info_0;
u32 cdw2;
};
union {
struct {
u16 data_len;
u16 param_len;
} info_1;
u32 cdw3;
};
u64 metadata;
u64 addr;
u32 metadata_len;
u32 data_len;
u32 cdw10;
u32 cdw11;
u32 cdw12;
u32 cdw13;
u32 cdw14;
u32 cdw15;
u32 timeout_ms;
u32 result0;
u32 result1;
};
struct sssraid_ioq_passthru_cmd {
u8 opcode;
u8 flags;
u16 rsvd0;
u32 nsid;
union {
struct {
u16 res_sense_len;
u8 cdb_len;
u8 rsvd0;
} info_0;
u32 cdw2;
};
union {
struct {
u16 subopcode;
u16 rsvd1;
} info_1;
u32 cdw3;
};
union {
struct {
u16 rsvd;
u16 param_len;
} info_2;
u32 cdw4;
};
u32 cdw5;
u64 addr;
u64 prp2;
union {
struct {
u16 eid;
u16 sid;
} info_3;
u32 cdw10;
};
union {
struct {
u16 did;
u8 did_flag;
u8 rsvd2;
} info_4;
u32 cdw11;
};
u32 cdw12;
u32 cdw13;
u32 cdw14;
u32 data_len;
u32 cdw16;
u32 cdw17;
u32 cdw18;
u32 cdw19;
u32 cdw20;
u32 cdw21;
u32 cdw22;
u32 cdw23;
u64 sense_addr;
u32 cdw26[4];
u32 timeout_ms;
u32 result0;
u32 result1;
};
struct bsg_ioctl_cmd {
u32 msgcode;
u32 control;
union {
struct sssraid_passthru_common_cmd ioctl_r64;
struct sssraid_ioq_passthru_cmd ioctl_pthru;
};
};
#endif // _SSSRAID_H
|