P111E

The document is an order form for a MiCOM P111 relay. It provides options to select the model type, mounting, auxiliary supply voltage, nominal currents and ranges for earth fault and phase overcurrent monitoring, and additional conformal coating.

Uploaded by

sbva
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
281 views1 page

P111E

The document is an order form for a MiCOM P111 relay. It provides options to select the model type, mounting, auxiliary supply voltage, nominal currents and ranges for earth fault and phase overcurrent monitoring, and additional conformal coating.

Uploaded by

sbva
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

MiCOM P111

Character Type (A=Alpha, N=Numeric, X = Alpha-numeric) Character Numbering (Maximum = 18) A 1 N 2 N 3 N 4 N 5 N 6 N 7 N 8 N 9 N N N N N N 10 11 12 13 14 15

P 1 1 1 7 3 9 1 0 1 5 0 4 4 1
To confirm options available, please insert REQUIRED despatch date here Generic Application Protection and Control Application MiCOM Overcurrent Relays
Format dd/mm/yyyy

P 1 1 1 7 3 9

Rear communication port RS485


Model: A, B, E, F, G (refer to Relay Type description) Model L: with RS485 Model L: without RS485

1 0

Mounting case:
please select ONE of the following: 35mm DIN rail (not available in model L) flush mounting

Relay type
please select ONE of the following: A, base model; 3ph 3 stages o/c (Total I/O: 2BI/2BO) B, base model + E/F input (IN) + RS485 (protocol MODBUS) (Total I/O: 2BI/2BO) E, model B + 2BI & 2BO + event recorder (Total I/O: 4BI/4BO) F, model E without communication (Total I/O: 4BI/4BO) G, earth fault only, RS485 (protocol Modbus) (Total I/O: 1BI/4BO) L, base model without binary inputs + E/F input + optional RS485 (Total I/O: 0BI/2BO)

Auxiliary supply Vx
please select ONE of the following: 60-240V AC/DC 24-48V AC/DC

E/F overcurrent; Nominal current and dynamic range of IN:


Note: Dynamic range amount to setting range for DT; For IDMT refer to documentation; hardware option given below can be connected to Ien: 1A or 5A CT. The value of nominal current Ien given below is defined for typical application only. please select ONE of the following (for all options: In=1A/5A) Ien=1A; 1 - 100% (not available in model A and G) Ien=5A; 1 - 100% (not available in model A and G) without Io (model A only) Ien=1A; 10 - 1000% (not available in model A and G) Ien=5A; 10 - 800% flush mouting only (not available in model A and G) Ien=1A /5A (software switch); 1-200% (model G only) All

3 phase O/C; Nominal current and dynamic range of Iph:


Note: Dynamic range amount to setting range for DT; For IDMT refer to documentation; option given below can be connected to 1A or 5A CT. In given below is defined for typical application only please select ONE of the following: In=1A; 40 - 4000% (not available in model G) In=5A; 40 - 4000% (not available in model G) No phase currents - P111 model G only All hardware The value of nominal current

Additional ordering options:


Standard Electronic boards conformal coated