Is 14665 1 2000
Is 14665 1 2000
( Reaffirmed 2005 )
                             Indian Standard
                                                                                                       —
ICS 91.140.90
@ BIS 2000
FOREWORD
This Indian Standard (Part 1) was adopted by the Bureau of Indian Standards, after the draft finalized by the
Lifts and Escalators Sectional Committee had been approved by the Electrotechnical Division Council.
The standard on this subject was originally published’ as IS 3534 in 1966 and was revised in 1976. This new
                                                                                                                       —
series of standards is being brought out to reflect the latest trends in lift industry at National and International
level. A detailed study of data collected over a long period has been made before preparing this standard. Every
effort has been made to present the guideline in a simple form and it is hoped that the information furnished
would be helpful to architects, consultants and lift makers.
The net internal areas are kept as close as possible to those specified in 5.1 of IS 14665 (Part 3/See 1): 2000
and width and depth are generally chosen as modular dimensions in steps of 100 mm.
The dimensions given in Table 2 for goods lifts are for normal applications. For special requirements, the design
can be-modified to meet the requirements by mutual agreement between the purchaser and the supplier.
The clear inside dimensions should be measured at a height of one metre from the finished floor of the lift car
from panel to panel.
The pit depth and the dimensions of headrooms suggested in this standard will satisfy all the provisions of 4.5
of IS 14665 (Part 2/See 1) :2000 with regard to clearance and run by for car and counterweight.
The Composition.of technical committee responsible for the preparation of this standard is given at Annex A.
This standard is one among the series of standards finalized by the Lifts and Escalators Sectional Committee as
detailed below. This was done with a view to align the Indian Standards with the latest developments in the field
of Lifts and Escalators and also to align the standards with the European Norms on Lifts and Escalators EN 81.
Moreover, these standards are published with a view to have a uniform code for electric traction lifts all over
the country, where presently different rules are being followed by different states:
      IS 14665 Electric traction lifts: Part 1                 IS 3534:1979 Outline dimensions of electric lifts
      Guidelines for outline dimensions of                     (first revision)
      passenger, goods, service and hospital lifts
         Part 2 Code of practice for installation,
         operation and maintenance
             Section 1 Passenger and goods lifts               IS 1860: 1980 Code of practice for installation,
                                                               operation and maintenance of passenger and goods
                                                               lifts (Jrst revision)
            Section 2 Service lifts                             IS 6620: 1972 Code of practice for installation,
                                                                operation and maintenance of service lifts
          Part 3 Safety rules
             Section 1 Passenger and goods lifts                IS 4666:1980 Electric passenger and goods lifts
             Section 2 Service lifts                            IS 6383:1971 Electiicservice lifts
          Part 4 Components
             Section 1 Lift buffers                             IS 9803:1981 Buffers for electric passenger and
                                                                goods lifts
                                                                                       (Continued   on third cover)
                                                                                              IS 14665 (Part 1): 2000
Indian Standard
                                                          1
IS 14665 (Part 1): 2000
                                                           2
                                                                                                             IS 14665 (Part 1): 2000
                    Table 1 Recommended Dimensions of Passenger Lifts
                                  (Clauses 5.3 and 6.1)
                                            AH dimensions in millimetres.
                                                   ‘“-”-”-”----c
                                                         ~                                                                   ‘-
                                    i     !---
!:
       Table 1A Recommended Dimensions of Pit, Overhead and Machine-Room for Passenger Lifts
                                      (Clauses 5.3 artd6.1)
                                     Alldimensions in millimetres.
                                                                      4
                                                                                                         IS 14665 (Part 1) :2000
                                                                        ~-=-%+r--f
                                                                                                                                           —
                                                        ‘OP
                                                        .ANO IING
k- -—-4 L1
                                                                             1-
                                                                             MACHtNE-ROOM
                                                                             =C+2000            4
                ELEVATION
                Load                            CarInside                                  Lift Well                     Entrance
                                     -                                              ~
                 kg
                 (1)                      (2)                (3)                     (4)                (5)                  (:)
                 500                     1100               1200                    1900               1500                 1100
                1000                     1400               1800                    2300               2100                 1400
                1500                     1700               2000                    2600               2300                 1700
                2000                     1700               2500                    2600               2800                 1700
                2500                     2000               2500                    2900               2800                 2000
                3000                     2000               3fJoo                   2900               3300                 2000
                4000                     2500               3000                    3400               3300                 2500
                5000                     2500               3600                    3400               3900                 2500
NOTES
1 The width of machine-room shall be equal to the lift well w.dth ‘C’ subject to minimum of 2500 mm.
2   The total headroom has been calculated on the basis of a car height of 2.2 m.
3 Clear entrance width ‘1? is based on vertical lifting car-door and vertical biparting landing doors. For collapsible mid-bar doors the
clear entrance width will be reduced by 200 mm (maximum 1800 mm).
4   All dimensions given above are recommended dimensions primarily for architects and building planners.      Any variations mutually
agreed ~tween manufa@rer and purch=r are permitted.           However. vafiation in CUKinside dimensions shall ~ within the maximum
area limits sfxcified in [S 14665 (Part 3/See 1).
5 Dimensions of pit depth and overhead may differ in practice as per individual manufacturer’s design depending upon load, speed
and drive. However, the pit depth and overhead shall be such as to conform to the requirem~nts of bottom clearance and top clearance
of 1S 14665 (Part 2/See I).
                                                                    5
IS 14665 (Part 1) :2000
——
LAN DING
                                 TRAVEL
                                                                                                                                        >
                                                                                                                           -_-L
                                              BOTTOM      LANDING
                                                                                   Pmw4
                                       A
               ELEVATION
            Load                                      Carhide                                    Lift Well                      Entrance
 f                          \                   c                     T                    t                    \
 Persons                kg                       A
 (1)                    (2)                     (3)                (:)                     (:)                (:)                   (?)
 15                    1020                    1000               2400                    1800               3000                  800
 20                    1360                    1300               2400                    2200               3000                  1200
 26                    1768                    1600               2400                    2400               3000                  1200
       NOTES
       1 The total headroom has been calculated on basis of cm’ height of 2.2 m.
       2   In the case of manually-operated   doors, clear entrance will be redueed by the amount of projection of handle on the landing door.
       3 Although 15 persons capacity lift is not standard one, this is included to cover lifts of smaller capacity which can be used in small
       hospitals.
       4 All dimensions given above are recommended dimensions primarily for architects and building planners. Any variations [mutually
       ngreed between manufacturer and purchaser are permitted. However, variation in car inside dimensions shall be within the maximum
       area limits specified in 1S 14665 (Part 3/See 1).
       5 Dimensions of pit depth wrd overhead may differ in practice as per individual manufacturer’s design depending upon load, speed
       and drive. However, the pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clcariuree
       of IS 14665 (Part 2/See 1).
                                                                          6
                                                                                                            IS 14665 (Part 1) :2000
                                  T
                              120iJ
                                                                                                                                      —
                              L
                                                                                      ------ 1
                                                                                                                   i
                                                                           L.-
                                             1-
                                                  0                        d-
                                                                           I        t-A--
                                                                                               E~
TRAVEL
         ELEVATION
          Load                                        Car Inside                              Lift Well                   Entrance
t          h           \                    ~                                       r-----y
kg                     A                                                             c
(1)                   (~)                   (3)                    (4)              (5)                   (6)                 (:)
100                   700                   700                 800                 1 2eo                  900               700
150                   81XI                  800                 900                 1300                  10IXI              800
200                   9txt                  900                1(X)O                1400                  1 ltxl             900
250                  1000                  1000                1200                 1500                  1200              1000
     NOTE — Entrmrce width ‘E’ is based on assumption of provision of vertical biparting doors (no car door is normally provided).
IS 14665 (Part 1): 2000
                                                       ANNEX A
                                                       (Foreword)
                                         COMMITTEE COMPOSITION
                                   Lift and Escalator Sectional Committee, ET 25
     Chairman                                                                        Representing
SHRID. H. PATIL                                                Maharashtra Public Works Department
      Members
PRESICJENT                                                     Practicing Engineers, Architects & Town Planners, Mumbai
PRESIDENT                                                      Builderrs Association of India, Mumbai
SHRJS.V. KAMAT                                                 Bharat Bijlee Ltd. Mumbai                                                —
  SHRIP. M. TIPNIS(Alremare)
SHRIS. N. SAREEN                                               Central Electricity Authority, New Delhi
   SHRIP. GUJRAL(Ahernate)
SHR[M. I. KHUMRI                                               Govt. of Gujarat (IW), Energy & Petrochemical Dept. Gandhinagar
SHRIK. KFUSHNAMURTHY    NAIK                                   Chief Electrical Inspector (Kamataka), Bangalore
   SHRIM. S. BASAVARJU    (Alrerna~e)
SHRIS. KULASEKHARAN                                            “Chief Electrical Inspector (Tamii Nadu), Chennai
   SHRIN. RANGASWAMY     (Alternate)
SHRi D. K. SEN                                                 Chief Electrical Inspector (West Bengal), Calcutta
   SHRIS. K. MITRA (Alternate)
SHRIM. S.-BHATTACHARJEE                                        Central Mechanical Engineering Research Institute, Durgapur
   SHRISANATANCHATTERJEE       (Ahemafe)
CE(E)                                                          Central Public Works Department, New Delhi
   SE (E) DCEVI (Ahemate)
SHRI S. K. fCMLA                                               Ministry of Defence, New Delhi
   SHRIB. K. BEHL(Alternate)
SHRI 1. Q. NAJAM                                               Maharastra Public Works Department, Pune
SHRIN. SUBRAMANAN                                              Dkectorate General of Supplies & Disposal% New Delhi
   SHRIA. K. RAI (Afrerrrate)
SHRIP. K. BANKA                                                ECE Industris Ltd, Ghaziabad
   SHRI JAGATMOHAN(Al[ernaie)
SHRIP. GURUMOORTHY                                             Kone Elevator In&la Ltd,.Chennai
   SHRIJ. SWARAMAN(Alfernate)
SHRIK. L. GROVER                                               Office of the Labour Commissioner,   Delhi Administration,   New Delhi
   SHRIAWNASHAGGARWAL(Alternate)
S~RI A. S. HERWADKAR                                           OTIS Elevator Co (lndia) Ltd, Mumabi
   DR G. M. MALKANI/SHRIS. P. RAO (A/fernafe)
SHR[K. M. BHATIA,                                              Director General, BIS (lZx-o&cio Member)
  Director (Elec tech)
                                                      Member-Secretary
                                                        SHRIG. BABU
                                                Deputy Director (Elec tech),   BIS
                                                                8
(Continued from second cover)
           Section 2 Lift guide rails and guide              IS 10191 : 1982 Car and counter weight guide
           shoes                                             rails, guide rail supports and fastenings for lifts
                                                                                    and
                                                             IS 11615 : 1986 Car and counter weight guide
                                                             shoes for electric passenger and goods lifts
           Section 3 Lift carframe, car, counter             IS 11706 : 1986 General requirements for
           weight and suspension                             car-frame for electric passengers and goods lift
           Section 4 Lift safety gears and                   IS 9878 : 1981 Safety gears and governors for          .
           governors                                         electric passenger and goods lifts
           Seetion 5 Lift retiring cam                       IS 10448:1983     Retiring cam for passenger and
                                                             goods lifts
           Section 6 Lifts doors and locking                 IS 7759 : 1975 Lift door Ioeking devices and
           devices and contacts                              contacts
                                                                                and
                                                             IS 11633:1986 Lift doors
            Section 7 Lift machines and brakes               IS 10913:1984 Brakes for electric passenger and
                                                             goods lifts
            Section 8 Lift wire ropes                                              —
Details about installation, maintenance and operation of electric traction lifts, passenger and service lifts are
covered in IS 14665 (Part 2/See 1 and 2). The constructional and safety aspects of these types of lifts are given
in (Part 3/Section 1 and 2).
For.the purpose of deciding whether a particular requirement of this standard is complied with, the final value,
observed or calculated, expressing the result of a test or analysis, shall be rounded off in accordance with
IS 2:1960 ‘Rules for rounding off numerical values (revised)’. The number of significant places retained in
the rounded off value should be the same as that of the specified value in the standard.
                                                                                                                               I
BUS is a statutory institution established under the Bureau of Indian Standards Act, 1986 to promote
harmonious development of the activities of standardization, marking and quality certification of goods
and attending to connected matters in the country.
Copyright
BIS has the copyright of all its publications. No part. of these publications may be reproduced in any form
without the prior permission in writing of BIS. This does not preclude the free use, in the course of
implementing the standard, of necessary details, such as symbols and sizes, type or grade designations.
Enquiries relating to copyright be addressed to the Director (Publications), BIS.                                              —
Amendments are issued to standards as the need arises on the basis of comments. Standards are also reviewed
periodically; a standard along with amendments is reaffirmed when such review indicates that no changes are
needed; if the review indicates that changes are needed, it is taken up for revision. Users of Indian Standards                i,
should ascertain that they are in possession of the latest amendments or edition by referring to the latest issue of
‘BIS Catalogue’ and ‘Standards: Monthly Additions’.
This Indian Standard has been developed from Doc : No. ETD 25 ~4098 ).
                                                                                                                               (
      Amend No.                                   Date of Issue                                            Text Affected