Ultra-Tec Cable Railing
Ultra-Tec Cable Railing
com
                materials: steel and stainless steel pipe; stainless steel flat        sioning mechanisms for cable barri-
 SYSTEM
                bar; structural tubing; and wood. Please note that the                 er railings – sharp edges on retain-
                Ultra-tec® Cable Railing System is not recommended for                 ers; long, bulky fittings; and
                use with aluminum pipe or tube.                                        uneven, hand-crimped shanks.
                                                                                       Standard marine turnbuckles and
                Type 316 stainless steel cable and hardware are used.                  stud fittings with exposed nuts and
                Due to the increased amounts of nickel and the addition of             threads were the norm because that
                molybdenum, type 316 stainless steel has excellent resist-             was all that was available – until
                ance to atmospheric and corrosive conditions.                          now.
RAILING
GLASS
                swaged in the field by using one of our portable swaging                                                 cable railing. It highlights attractive
                tools. Swaging in the field permits intermediate post and                                                pre-engineered metal frame styles
                                                                                                                         that utilize standard off the shelf
                braces to be bored just slightly larger than the diameter of                                             materials. Included are drawings
                the cable being used since only the cable will have to pass                                            and specifications that will ensure
                through. If purchased pre-swaged, the intermediate posts                                              that the frame will perform successful-
                and braces have to be bored to allow for the larger diam-                                           ly when all cables are properly ten-
SPIRAL STAIRS
 BALCONIES
                By using our pre-tensioning tool, runs of up to 150 feet               steel fittings are engineered to inter-
                and longer can be achieved while maintaining tight cable               face with standard frame compo-
                tension using Ultra-tec® hardware.                                     nents detailed in our Design &
                                                                                       Fabrication Guide for Metal Framed
                Refer to installation instructions on page 259 to 271.                 Railings. Ultra-tec® railing hard-
                                                                                       ware can be factory swaged by us or
                Note: Due to the effects of thermal expansion and contraction, max-    field swaged by the customer, using
                imum run for exterior railings is 100 feet.                            an Ultra-tec® portable swaging tool.
BRASS / SS
                                                                                                                                                                                                              WAGNERAIL
                                                                                                                                                                                                               SYSTEM
                             inside the end post with only the
                             head of the Receiver exposed on the                                 Allen Head
                             outside of the post. The inside is                                                                                                                                Cable
                                                                                                         Counterbored Hole
                             female-threaded to accept the male-                                             On Pipe Only
threaded Invisiware® Swaging Stud that is attached to the cable. The                      Pipe        Actual      Cable                                                               Use with
                                                                                          Size         Size       Size           L         D      H                 T            S     Stud # Stainless
head of the Receiver is broached for an Allen wrench. To tension the
cable, insert the Allen wrench and rotate the Receiver around the                         1 /4"
                                                                                           1
                                                                                                  1.660"        /8" 1.56" .437" /16" /16-24 .537" CRS4
                                                                                                                     1                           3              5
                                                                                                                                                                                                 CRR612
male threads on the Swaging Stud. This will draw the Swaging Stud                         11/4"   1.660"      3
                                                                                                               /16" 1.56" .437" 3/16" 5/16-24 .537" CRS6                                         CRR612
further inside the Receiver as you continue to turn it with the Allen                     11/2"   1.900"       1
                                                                                                                /8" 1.81" .437" 3/16" 5/16-24 .537" CRS4                                         CRR622
                                                                                                                                                                                                              RAILING
                                                                                          11/2"   1.900"      3
                                                                                                               /16" 1.81" .437" 3/16" 5/16-24 .537" CRS6                                         CRR622
                                                                                                                                                                                                              GLASS
wrench.
                                                                                          11/2"   1.900"       1
                                                                                                                /4" 1.81" .531" 7/32" 7/16-20 .646" CRS8                                         CRR822
Pipe ends are counterbored so the full perimeter of the head of the                        2"     2.375"       1
                                                                                                                /8" 2.30" .437" 3/16" 5/16-24 .537" CRS4                                         CRR642
Receiver will rest on a flat surface in the pipe. The head rests on the                    2"     2.375"      3
                                                                                                               /16" 2.30" .437" 3/16" 5/16-24 .537" CRS6                                         CRR642
outside wall of a flat-sided post. A plastic washer is included and                        2"     2.375"       1
                                                                                                                /4" 2.30" .531" 7/32" 7/16-20 .646" CRS8                                         CRR842
acts as a scratch resistant barrier between the Receiver head and                                1" × 2"† 1/8" 3.03" .437" 3/16" 5/16-24 .537" CRS4                                              CRR652
the post.                                                                                        1" × 2"† 3/16" 3.03" .437" 3/16" 5/16-24 .537" CRS6                                             CRR652
                                                                                                  2" × 2"      1
                                                                                                                /8" 2.03" .437" 3/16" 5/16-24 .537" CRS4                                         CRR632
                                                                                                  2" × 2" 3/16" 2.03" .437" 3/16" 5/16-24 .537" CRS6                                             CRR632
                                                                                                                                                                                                              RAILING
                                                                                                                                                                                                              CABLE
                                                                                                  2" × 2"      1
                                                                                                                /4" 2.03" .531" 7/32" 7/16-20 .646" CRS8                                         CRR832
                 Swaged Stud                                                                     1" × 3"† 1/8" 3.03" .437" 3/16" 5/16-24 .537" CRS4                                              CRR652
                                                                                                 1" × 3"† 3/16" 3.03" .437" 3/16" 5/16-24 .537" CRS6                                             CRR652
                                                                                               31/2" × 31/2"* 1/8" 3.56" .437" 3/16" 5/16-24 .537" CRS4                                          CRR662
                                                                                               31/2" × 31/2"* 3/16" 3.56" .437" 3/16" 5/16-24 .537" CRS6                                         CRR662
                          Invisiware                                                      * Nominal 4 × 4 wood post – 31/2" × 31/2" actual.
                                                                                          †
                           Receiver                                                         Use as double posts with spacer shown on page 58.
                                                                                                                                                                                                              SPIRAL STAIRS
                                                  Spacer
                                                                                                                                                                                                               BALCONIES
                                                                                                                           H                                                          T
        Pipe, Tube                     Double Post with Spacer
       or Wood Post
                                                                                                                                                                                          D
Invisiware® Receivers can be used in a horizontal position on stair end posts that have
a pitch up to 35 degrees. This eliminates the need to bore hardware holes at an angle
on stair runs.                                                                                                             S
                                                                                                                                                                                                              ALUMINUM
                                                                                                                                                                                                              RAILINGS
Type 316 Stainless Steel
                                For use on the fixed, non-tensioning end of the cable, often in com-                                                                              L
                                bination with the Invisiware® Receiver on the tensioning end. When                                                    D
                                installed, the fitting is hidden inside the end post with only the
                                head exposed on the outside of the end post. Externally, it looks
                                the same as the Invisiware® Receiver, but costs much less.                                                                                                             S
                         Pipe ends are counterbored, so the full perimeter of the head of
the Radius Ferrule will rest on a flat surface in the pipe. The head rests on the outside
                                                                                                                                                                                                              BRASS / SS
                                                                                                                                                                                                               FITTINGS
wall of a flat-sided post. A plastic                                                                                                                                    A
                                                             Post
washer is included and acts as a Swaged Radius
scratch resistant barrier between         Ferrule
                                                  Washer
the Radius Ferrule head and the                                                                                           Cable
                                                                                Cable
post.                                                                                                                     Size            D*              L*                S             A       Stainless
                                                                                                                             /8"
                                                                                                                             1
                                                                                                                                         .250"        .750"              .537"         .437"     CRRF4
For pipe and square tube railing only. The
Radius Ferrule should not be used on rectan-
                                                                                                                           3
                                                                                                                            /16"         .250"        .750"              .537"         .437"     CRRF6
                                                   Counterbored                                                             1
                                                                                                                             /4"         .375"        1.00"              .646"         .531"     CRRF8
gular, double post construction.
                                                    Hole In Pipe
                                                                                                                                         * After Swaging
                NEW!
                FIELD INSTALLED PUSH-LOCKTM                                                                 H      !                                          K      !
                                                                                                         US                                                OC
WAGNERAIL
                EASY TO INSTALL
                NO FIELD SWAGING!
                Cables come with a tensioner on one end. Install
                the tensioner on one end post, then cut the cable
                to length. Slip the Push-Lock fitting into the other
                end post or mount it with the tab to the outside of
                the post.
RAILING
GLASS
to allow for potential fraying. Cut each cable to a final length on site and push it into the opening in the Push-Lock fitting.
                These Push-Lock fittings with rounded ends are used on level runs. They rest in a hole in the end post. When used with an end post 1-1/2"
                or more in thickness, the Push-Lock fitting is hidden inside the end post with only the head exposed on the outside of the post. Pipe ends are
                counterbored, so the full perimeter of the head will rest on a flat surface in the pipe. A plastic washer is included and acts as a scratch-resist-
ALUMINUM
RAILINGS
                ant barrier between the Push-Lock fitting and a metal post. The head rests on the outside wall of a flat-sided metal post or on a stainless steel
                washer on a wooden post. For wood applications, also order part number CR716SAE Washer.
                                                                                                                              .435"
 FITTINGS
.313"
                                                                                                                                             2.45"
                These fittings have a 1⁄4-28 threaded eye end and are for use on stairs. They
                attach to a wood end post with a CRLE6 shown on page 51. For metal
                posts, use a Fixed Tab or Threaded Tab. Mount with a CRSC6 Screw.
                Cable                                  Use with               For Wood Post                     For Stainless Post                        For Steel Post
                Size             Stainless             Screw #                Use Lag Eye #      Use Fixed Tab #             Use Threaded Tab #         Use Threaded Tab #
                 1
                  /8"          CRPLTE4                 CRSC6                    CRLE6             CRFT65B                       CRTT6B                     CRFT65A
                 /16"
                 3
                               CRPLTE6                 CRSC6                    CRLE6             CRFT65B                       CRTT6B                     CRFT65A
                                                                                                                                                                                                WAGNERAIL
                              Here’s a real time and money-saver.
                                                                                                                                                                                                 SYSTEM
                              The Invisiware® Threaded Tab
                              screws into a drilled and tapped hole                                                                                                     3
                              on the inside wall of the end post.                                                                                                           /8"
                              You save the expense of welding
                              tees or tabs onto your end post,
                              for mounting Adjust-A-Jaw® or
Adjust-A-Body™ Tensioners or Ultra-tec® Fixed Jaws.                       Cable
                                                                          Size                H        S               T              A         B               L       Stainless
Recommended only when you are using a minimum schedule 80                   /8" .265" .500" .233"/.229" .813" .313" 1.250" CRTT6B
                                                                              1
pipe end post or a square or rectangular steel end post with a min-
                                                                                                                                                                                                RAILING
                                                                          3
                                                                           /16" .265" .500" .233"/.229" .813" .313" 1.250" CRTT6B
                                                                                                                                                                                                GLASS
imum .250" wall.                                                           1
                                                                            /4" .390" .625" .295"/.285" 1.250" .375" 1.625" CRTT8B
INVISIWARE® EXTENDED LENGTH THREADED TAB                                  Cable
                                       Extended length, same              Size                     Stainless
                                       as above except there is              /8"
                                                                              1
                                                                                  CRTT6BL
                                       no need to thread the               3
                                                                            /16"  CRTT6BL
                                       hole in your end post.               1
                                                                             /4"  CRTT8BL                    1.05
Cut to desired length and secure to end post with acorn nut and
thread sealant or Lido-Weld Adhesive – see page 39.                       Acorn Nut – CRAN37524S – is included.
                                                                                                                                                                                                RAILING
                                                                                                                                                                                                CABLE
                                                                                                                                                                                       H
INVISIWARE® FIXED TAB
                                                                                                               D
Steel or Stainless Steel
                                        Welded into an end post to
                                                                                                                                           L                            S
                                        make a strong tab for use
                                                                                                                                                                                                SPIRAL STAIRS
                                        in mounting an Adjust-A-
                                                                                                                                                                                                 BALCONIES
                                        Jaw® or Adjust-A-Body™
                                                                                                                                                                                           T
Tensioner or Ultra-tec® Fixed Jaw. The Invisiware® Fixed Tab is
cut to length as necessary, inserted in a hole drilled through the
post and welded to the outside wall. The welded surface is then       Cable
ground to the post’s original contour, thus hiding the weld.          Size                D            H           S             T             L                Steel             Stainless
                                                                      1
                                                                        /8"           .375"        .265" .44" .233"/.229" 3.11" CRFT65A CRFT65B
                                                                      3
                                                                       /16"           .375"        .265" .44" .233"/.229" 3.11" CRFT65A CRFT65B
                                                                       1
                                                                        /4"           .562"        .390" .68" .295"/.285" 3.00" CRFT85A CRFT85B
                                                                                                                                                                                                ALUMINUM
                                                                                                                                                                                                RAILINGS
INVISIWARE® WELDED RECEIVER
                                                                                                                                                                                   T
Steel or Stainless Steel
                                  A fixed end, non-tensioning
                                  device, the Invisiware® Welded
                                  Receiver provides a sturdy,
                                  threaded receptacle in the end                                                                       2.82"                                       D
                                  post for an Invisiware® Swaging
                                  Stud. The Invisiware® Welded
                                                                                                                                                                                                BRASS / SS
                                                                                                                                                                                                 FITTINGS
Receiver is cut to length as necessary, inserted in a hole drilled            Cable                                             Use with
through the post and welded to the outside wall. The welded sur-              Size                 D               T             Stud #             Steel                   Stainless
face is then ground to the post’s original contour, thus hiding the               1
                                                                                    /8"           .437"        5
                                                                                                                 /16-24         CRS4           CRWR65A                  CRWR65B
weld.                                                                             3
                                                                                   /16"           .437"        5
                                                                                                                 /16-24         CRS6           CRWR65A                  CRWR65B
                                                                                   1
                                                                                    /4"           .531"        7
                                                                                                                 /16-20         CRS8           CRWR85A                  CRWR85B
                                                                          Cable
                                                                          Size                             G                T              L                P               Stainless
                                                                                /8"
                                                                                  1
                                                                                                  .233"/.229"             .253"        1.50"          .50"                  CRLE6
                                                                              3
                                                                               /16"               .233"/.229"             .253"        1.50"          .50"                  CRLE6
                                                                               1
                                                                                /4"               .295"/.285"             .385"        2.00"          .68"                  CRLE8
                                                                                                                                              Lp
                Similar to the Adjust-A-Jaw® Tensioner, except it screws right into
                your wooden end post. No need for special mounting hardware. A
                                                                                                                                                                                               For use with a minimum 4 × 4
                sleek, economical tensioning device that is easy to install, adjusts                                                                                                           nominal wood post
                with an open-end wrench. Now available with a 11/2" longer hanger
                bolt for 1/8" or 3/16" cable.                                                                     *Longer shaft – Lp – for use when
                                                                                                                  mounting post has a fascia covering.
                      1
                        /8"        5
                                     /16"         5
                                                    /16-24       1.50"           .25"            2.00"          3.75"               .375"                2.75"             .500"         CRF4            CRAJB6
                       1
                        /8"        5
                                     /16"         5
                                                    /16-24       1.50"          1.75"            2.00"          5.25"               .375"                2.75"             .500"         CRF4            CRAJB6L
                      3
                       /16"        5
                                     /16"         5
                                                    /16-24       1.50"            25"            2.00"          3.75"               .375"                2.75"             .500"         CRF6            CRAJB6
                      3
                       /16"        5
                                     /16"         5
                                                    /16-24       1.50"          1.75"            2.00"          5.25"               .375"                2.75"             .500"         CRF6            CRAJB6L
                       1
                        /4"        7
                                     /16"         7
                                                    /16-20       2.00"           .25"            2.50"          4.75"               .500"                3.00"             .625"         CRF8            CRAJB8
BRASS / SS
 FITTINGS
                                                                                                                                                                            WAGNERAIL
                                               Similar to the Adjust-A-
                                                                                                                                                                             SYSTEM
                                               Body™ With Hanger
                                               Bolt Tensioner, it screws
into a Red Head brand concrete anchor – available from your indus-
trial supplier. It is an easy, practical way to attach your tensioner to
a concrete wall. Adjusts with an open end wrench.
                                                                                                                                                                            RAILING
                                                                                                                                                                            GLASS
      3
       /16"    3
                 /8-16      5
                              /16-24      .750"           2.38"   3.44"       .375"        2.75"      .500"         RL-38     SSRM-38      CRF6        CRAJAB6
       1
        /4"    1
                 /2-13      7
                              /16-20      1.12"           2.50"   3.93"       .500"        3.00"      .625"         RL-12     SSRM-12      CRF8        CRAJAB8
                                                                                                                                                                            RAILING
                                                                                                                                                                            CABLE
                                                   1
                                                    /8"     1,780 lbs      CR4AS2                in length.
                                                  3
                                                   /16"     4,000 lbs      CR6AS2
                                                   1
                                                    /4"     6,900 lbs      CR8AS2                To measure cable when ordering pre-cut and swaged cable:
                                                                                                   • Clearly identify fittings – by part number – that are to be used
Cable Construction: 1 × 19, Type 316 stainless steel cable.                                          with the cable.
1 × 19 construction cable is engineered to hold static loads without                               • For Invisiware® Receiver, Radius Ferrule or Clip-On Stop hard-
stretching and it is relatively stiff. Left hand lay cable for use with all                          ware, measure from back side of the post.
                                                                                                                                                                            SPIRAL STAIRS
Ultra-tec® Fittings                                                                                • For Adjust-A-Jaw®, Adjust-A-BodyTM, Threaded Stud with Welded
                                                                                                                                                                             BALCONIES
Design Parameters and Constraints: Cable has a very high ten-                                        Receiver or Fixed Jaw hardware, measure from the inside sur-
sile strength and is a suitable in-fill material for a guardrail. Spacing                            face of the post .
between posts and/or braces should not exceed 42".                                                 • For Adjust-A-Jaw®, Adjust-A-BodyTM or Fixed Jaw hardware, you
Recommended maximum vertical spacing of 3" free opening                                              may also measure from the center of the mounting hole.
between cables when they are installed. For most applications, 3/16"                               • Measure rail as if all are straight from tensioning post to anchor
diameter cable is recommended.                                                                       post. If rail is on a slope, measure on the slope.
Other cable constructions can be used, such as 7 × 7 or 7 × 19, but they are rarely rec-           Note: Re-spooling charges apply for orders under 5,000 feet.
ommended because of their elevated levels of stretch and lower breaking strengths in
                                                                                                                                                                            ALUMINUM
comparison to 1 × 19 construction.
                                                                                                                                                                            RAILINGS
                                                  Erik
                                                  4/4
                                                                                                                                                                            BRASS / SS
                                                                                                                                                                             FITTINGS
                                                                                                                                                                 Body            Cable
                                                                                                                                      Lock Nut
 SYSTEM
                                                              Tensioner is a precision
                                                              machined,             sleek,
                                                              streamlined tensioning
                device that is used where a high-tech look is desired. It is suitable
                for level runs or stair pitches. The clevis portion of the fitting attach-                                                  Tighten Lock Nut with
                es to the end post with a button head socket screw that threads                               Clevis Mounting
                                                                                                              Screw                         Open End Wrench
                directly into a tapped hole on one side of the clevis fitting.
                Unlike common turnbuckles, the Adjust-A-Jaw® Tensioner has no
                sharp edges, no crevices to collect dust and dirt, no large areas of
RAILING
GLASS
                ing with an open-end wrench. After tensioning, the Lock Nut locks the                      One Side
                assembly in place.                                                                           Only
                                                                                                                                                       Open
                                                                                                                         Note: Order ferrule and screw separately.
                       1
                        /8"     .260"       1
                                              /4-28           .260"        .56"       4.30"      5.99"         .375"        2.75"           CRSC6             CRF4         CRAJ62
                      3
                       /16"     .260"       1
                                              /4-28           .260"        .56"       4.30"      5.99"         .375"        2.75"           CRSC6             CRF6         CRAJ62
                       1
                        /4"     .390"       3
                                              /8-24           .313"        .75"       4.87"      6.43"         .500"        3.00"           CRSC8             CRF8         CRAJ82
                                                                                                                                                                 Fixed Jaw
                                      price of the clevis-style Adjust-A-Jaw® Tensioner. Where you do not                                                                               Cable
                need a tensioner on both ends of the cable run, the economical Ultra-tec® Fixed Jaw is
                frequently used on the fixed, non-tensioning end of the cable with the clevis-style
                Adjust-A-Jaw® Tensioner on the tensioning end.
                The Ultra-tec® Fixed Jaw makes a very attractive fitting where a high-tech look is desired on
                level runs as well as on pitches. The Invisiware® Swaging Ferrule is swaged onto the cable
                and holds the cable inside the clevis.
BRASS / SS
                See the tabulated drawing to determine how to interface this fitting with your end post, or use
 FITTINGS
our Fixed Tab or Threaded Tab fittings shown on page 51 of this catalog.
                                                                                                                                      One Side
                                                    Ultra-tec® Clip-on FIXED JAW for pre-swaged cable                                   Only
                                                    Type 316 Stainless Steel
                                              Same as our regular Ultra-tec® Fixed Jaw, except the cable                                               Ferrule                Clip
                                              attaches with a special clip that is installed by hand. All fittings
                are swaged on the cable at the factory, so no field swaging is required. An Adjust-A-Jaw® or
                Adjust-A-Body™ style tensioner or Invisiware® Receiver is used on the opposite end. Order
                using part numbers below and check with the factory to determine cable lengths to be pro-
                vided with swaged fittings. Available for 1/8" and 3/16" cable only. Refer to Clip-On Stop on page
                55.                                                                                                                    Note: Order ferrule and screw separately.
                     Cable                                                                                    Use with          Use with          Fixed Jaw        Clip-On Fixed Jaw
                     Size             D                 E             G           K             L             Screw #           Ferrule #         Stainless             Stainless
                      1
                       /8"       .260"              1
                                                      /4-28        .260"          .56"         1.75"          CRSC6             CRF4             CRFJ62                 CRFJC2
                      /16"
                      3
                                 .260"              1
                                                      /4-28        .260"          .56"         1.75"          CRSC6             CRF6             CRFJ62                 CRFJC2
                      1
                       /4"       .390"              3
                                                      /8-24        .313"          .75"         2.12"          CRSC8             CRF8             CRFJ82
                                                                                                                                                                                 WAGNERAIL
                                                                                                                                         Size           D*          Stainless
                                                                                                                                                                                  SYSTEM
                 an Adjust-A-Jaw® or Adjust-A-Body™ Tensioner or                                                                         1
                                                                                                                                           /8"      .250"            CRF4
                                                                                                                             D
                 an Ultra-tec® Fixed Jaw onto a piece of cable.                                                                          3
                                                                                                                                          /16"      .250"            CRF6
                 When installed, the Ferrule is locked inside the fit-                                                                    1
                                                                                                                                           /4"      .375"            CRF8
                 ting, so you never see unattractive swage marks                                                                                    *After Swaged
with an Invisiware® Swaging Ferrule.
                                                                                                                                                                                 RAILING
                                                                                                                                                                                 GLASS
Type 316 Stainless Steel                                                                                                                             Washer
                           For use in posts with cables cut and fittings                                                                         Stop                   Clip
                           attached –preswaged – at the factory. No
                                                                                                                                   /4"
                           field swaging is required. A special clip and
                                                                                                                                   1
                           washer secure the Stop to the end post.                                                                                 1"
                           Used on the non-tensioning end of the
                           cable. An Adjust-A-Jaw®, Adjust-A-Body™                        Cable Size         Post Material       Washer Diam.                   Stainless
             ®
or Invisiware Receiver is used on the opposite end to tension the                             1
                                                                                                /8"            Wood                    .922"                 CRCOS4
                                                                                                                                                                                 RAILING
cable. Available for 3/16" and 1/8" diameter cable only. Includes Stop,
                                                                                                                                                                                 CABLE
                                                                                              1
                                                                                                /8"            Metal                   .468"                 CRCOS4M
Washer and Clip. Refer to page 54 for Clip-On Fixed Jaw.                                      3
                                                                                               /16"            Wood                    .922"                 CRCOS6
                                                                                              3
                                                                                               /16"            Metal                   .468"                 CRCOS6M
                                                                                                                                                                                 SPIRAL STAIRS
Cable Grommets are offered for popular cable diameters of 1/8", 3/16"
                                                                                                                                                                                  BALCONIES
                                                                                                                                                        Installation Tool
and 1/4". They help prevent rust in exterior applications or elsewhere
where moisture is a factor by providing a barrier between the cable
and the painted or powder coated surface through which the cable
is drawn when being installed.
Ultra-tec® Cable Grommets are installed – after the paint or powder
                                                                                         Large Lip                                     Large Lip
coating is applied – into holes in intermediate posts, cable braces
and – in the case of the Invisiware® Radius Ferrule – into the end
post holes through which the cable exits. They are offered in black                Order Cable Grommets by diameter of cable and post through which
                                                                                                                                                                                 ALUMINUM
UV resistant HDPE.                                                                 the cable will be drawn. Sold in lots of 100. Specify quantity when
                                                                                                                                                                                 RAILINGS
                                                                                   ordering.
                               Intermediate Post Material                      End Post Material                     Intermediate Post Material Slotted
                                Not slotted for Stairways                    Using Radius Ferrule                  For Stairway Pitch Up To 37 Degrees
         Cable     11/4" to 2"    Square or Rect. Tube    1
                                                           /4" Cable   11/4" to 2"   Square or Rect. Tube     11/4" to 2"   Square or Rect. Tube 1/4" Cable
         Size         Pipe           with .120" Wall         Brace        Pipe          with .120" Wall          Pipe          with .120" Wall       Brace
    1
        /8" or 3/16" CRGC61100     CRGC62100           CRGC64100 CRGC63100             CRGC64100            CRGIC61100 CRGIC62100 CRGIC64100
            1
              /4"    CRGC81100     CRGC82100           CRGC84100 CRGC83100             CRGC84100            CRGIC81100 CRGIC82100 CRGIC84100
                                                                                                                                                                                 BRASS / SS
                                                                                                                                                                                  FITTINGS
                                                                                                                                                                       Mike
                                                                                                                                                                       1/33
                                     • End Posts are drilled through or drilled and tapped on one side for use with
                                       Invisiware® Threaded Tab.
                                     • Intermediate Posts are provided with through holes.
                                     Wagner can also customize your posts with counterbored holes, coped connec-
                                     tions, special bends, or miters. Download a Post Order Form at www.wagnerca-
                                     blerailing.com or Contact Wagner for pricing.
                                                                                                                                                                   Intermediate Post
                                     Material Options: Steel and Stainless Steel in sizes as indicated. When ordering,
                                                                                                                                                                                                      Cable Brace
RAILING
                                     note size of cable to be used. Wood posts – minimum 4 × 4 nominal lumber – are sup-
GLASS
                                                                                                                                          End Post
                plied by others.
                CABLE BRACES
                1
                 /4" × 1" Cable Braces are used to support the cables between End or Intermediate Posts. They keep the
                cable from flexing excessively when a load is applied. Cable Braces are attached to the top rail and to
                the lower mounting surface – either a bottom rail or deck. Download a Cable Brace Order Form at
                www.wagnercablerailing.com
                                                                                    Pipe Size Tube Size Schedule      Wall
                                                                                      11/4"     1.660"         40     .140"
RAILING
CABLE
                                                                                                                                                                                                           a
                                                                                                              a
                Railings at www.wagnercompanies.com/
                cablerailing. Cable must be supported
                every 42" mid run by either a Cable Brace
                or Intermediate Post.
                                                                                                                                                                                                                    h
                                                                                                                 h
                                                                                                              a
                                                                                                                                                                                                           a
                RECTANGULAR TUBE POST
                End Post: Double 1" × 3" or 1" × 2" tube
                                                                                                              31/2"
                Invisiware® Fitting.
                Cable Brace: 1/4" × 1" bar with through
                holes for cable.                                 SQUARE TUBE POST – WELDED ASSEMBLY
                Intermediate Post: 1" × 3" or 1" × 2" tube        End Post    Cable Brace     Intermediate Post               End Post               Cable Brace                       Intermediate Post
                with through hole and grommets.
                SQUARE TUBE POST
                                                                                                              a
                End Post: 2" × 2" tube with 1" × 2" top rail.
                Cable Brace: 1/4" × 1" bar with through
                holes for cable.
                Intermediate Post: Double 1" × 2" tube
                with through hole and grommets.
                                                                                                                 h
                                                                                                                                                                                                                    h
                                                                                                              a
                                                                                                                                                                                   WAGNERAIL
Cable Brace: 1/4" × 1" bar, notched for pipe
                                                                                                                                                                                    SYSTEM
                                                                                                                                                                           a
                                                                                                          a
with through holes for cable.
Intermediate Post: Schedule 40 pipe with
through holes for cable.
                                                                                                                                                                             h
90º FORMED ELBOWS
                                                                                                                                                                           a
           Pipe
                                                                                                          a
           Size   r    OD      Steel   Stainless
                                                                                                                                                                                   RAILING
            11/4" 15/8" 1.660" 4434* 4654
                                                                                                                                                                                   GLASS
        R
            1  /2" 15/8" 1.900" 4464* 4684
                                                                                                          31/2"
              1
       r
             2" 1" 2.375" 410 459-1
*Note: These elbows have a visible seam.
 For other elbows refer to pages 165 to 181.
                                                           Pipe           h          cable            a                Pipe           h              cable             a
                                                           11/4"       361/2"        8   lines     3.30"               11/4"        361/2"       10 lines            3.17"
                                                           11/4"       421/2"       10   lines     3.24"               11/4"        421/2"       12 lines            3.14"
                                                           11/2"       361/2"        8   lines     3.24"               11/2"        361/2"       10 lines            3.15"
                                                                                                                                                                                   RAILING
                                                           11/2"       421/2"       10   lines     3.20"               11/2"        421/2"       12 lines            3.12"
                                                                                                                                                                                   CABLE
                                                            2"         361/2"        8   lines     3.14"                2"          361/2"       10 lines            3.10"
             Seamed Elbow                                   2"         421/2"       10   lines     3.11"                2"          421/2"       11 lines            3.34"
                                                                                                                                                                                   SPIRAL STAIRS
runs through the tube – and eliminates the cost and visual obstruction of additional mount-                                   • Steel and Stainless Steel
                                                                                                                                                                                    BALCONIES
ing and tensioning hardware.                                                                                                  • Drill 5⁄8" through hole in post and
                                                                                                                                chamfer one side for welding
These corner sections are provided as components: elbows, posts and cable tubes. Each                                         • Insert Cable Tube into pre-drilled
post is custom designed per job requirements with holes pre-drilled to accept cable tubes.                                      posts and weld into place.
Posts can also be provided pre-coped and in various styles and angles. All posts are custom                            Tubing                                 Satin Finish
made based on customer provided, detailed shop drawings. Upon request, Wagner can pro-                                Diameter               Steel             Stainless
vide shop drawings – standard charges will apply.                                                                        5
                                                                                                                          ⁄8"             CR0113              CR0114.4
To use cable tubes, clear holes are drilled in the posts to accept these smaller diameter elbows.
The cable tubes are then inserted through the holes and welded into place. The cable may now
                                                                                                                                                                                   ALUMINUM
                                                                                                                                                                                   RAILINGS
be inserted through the tube providing a uniquely attractive fabrication.
For complete design and fabrication information, download our Product Design and                                                    Cable Tube
Fabrication Guide for Metal Framed Railings at www.wagnercablerailing.com.
                                                                                                                                                                                   BRASS / SS
                                                                                                                                                                                    FITTINGS
                                                                                                                                                         Double Posts
                                                                                                                                                      Without Cable Tubes
                MOUNTING PLATES
                                                                                                        CABLE BRACE FLOOR PLATE
                For installation details and mounting options using these compo-
                                                                                                                                                     •   /4" Thick
                                                                                                                                                         1
WAGNERAIL
                                                                                     Pipe Size   Tube Size      With 1" Spacer          a            b            Slots             1018                Type 304
CABLE
                                                                                        1 /4"
                                                                                          1
                                                                                                  1.660"                                5"           6"                1         CRFAP4                CRFAP4S
                                                                                        11/2"     1.900"                                5"           6"                1         CRFAP4                CRFAP4S
                                                                                         2"       2.375"                                6"           7"                1         CRFAP5                CRFAP5S
                                                                                                  1" × 3"                               4"           5"                1         CRFAP1                CRFAP1S
                                                                                                  3" × 3"          1" × 3"              6"           7"                2         CRFAP3                CRFAP3S
                                a                                                                 1" × 2"                               4"           5"                1         CRFAP1•               CRFAP1S
SPIRAL STAIRS
                                                      mounting screws
                                                    • Weld to pipe from the
                          a
                                        b             back side
                                                                                                                                                                       Spacer
                              Outside                                  Steel     Stainless
                Pipe Size     Diameter        a             b          1018      Type 304                           Cable               Diameter             Wall Thickness             Length           Stainless
                  11/4"       1.660"         3"          21/2"       CRFLP1M   CRFLP1MS•                               1
                                                                                                                         /8"                 5
                                                                                                                                              /8"                  .083"                .970"         CRSPCR6
BRASS / SS
                                                                                                       WASHERS
                                                                                                       Available in Stainless Steel and Delrin® plastic.
                FOR SQUARE OR RECTANGULAR TUBING                                                               Cable           Outside Diam.             Inside Diam.            Stainless       Delrin® Plastic
                                                    • Countersunk for 1/4" mounting screws.              1
                                                                                                             /8" or 3/16"          59
                                                                                                                                     /64"                    15
                                                                                                                                                                /32"            CR716SAE CRWR6B
                                                    • Use for square tube or rectangular tube.                   1
                                                                                                                   /4"             11/16"                    17
                                                                                                                                                                /32"            CR050SAE CRWR8B
                                                    • Use spacer shown to the right between
                                                      posts for double post applications.
                      a                             • Butt weld to tube.
                                        b                                                              BEVELED WASHERS
                                                                                                       Stainless steel. For use with solid bar or
                                                                                                       posts drilled at an angle.
                                Double Post                            Steel     Stainless
                 Tube Size     With 1" Spacer        a          b      1018      Type 304
                 1" × 3"                            31/2"     3"     CRFLP7M   CRFLP7MS                                                                                    Cable Size
                 3" × 3"            1" × 3"          5"      31/2"   CRFLP8M   CRFLP8MS                          Angle                     /8"   1                       3
                                                                                                                                                                          /16"                  1
                                                                                                                                                                                                 /4"
                 1" × 2"                             3"      21/2"   CRFLP4M   CRFLP4MS                       30° - 33°                 CRBW326                        CRBW326               CRBW328
                 2" × 3"            1" × 2"          5"      21/2"   CRFLP6M   CRFLP6MS                       34° - 36°                 CRBW356                        CRBW356               CRBW358
                 2" × 2"                             4"      21/2"   CRFLP5M   CRFLP5MS                       37° - 39°                 CRBW386                        CRBW386               CRBW388
                                                                                                                                                                         WAGNERAIL
                                                                                                                                                                          SYSTEM
ware is used in wood end and corner posts. A minimum of a
nominal 4 × 4 (31/2" × 31/2" actual) is recommended for any
post where cable hardware is mounted.
Cables should be spaced on end posts on centers of no
more than 3.25", and the cable should be supported in some
fashion no more than every 42" along the cable run.
Cables can be cut and fittings swaged in the field using
Ultra-tec® swaging equipment – available for rent or pur-
chase.
                                                                                                                                                                         RAILING
                                                                                                                                                                         GLASS
With some hardware, the cable can be cut to customer pro-
vided lengths and the fittings swaged on at the factory thus
providing ready to install hardware.
Go to page 258 for more information on installing Ultra-tec
cable rail with wood posts.
Invisiware Invisiware
                                                                                                                                                                         RAILING
                                                                                                                                Receiver with
                                                                                                                                                                         CABLE
               Radius Ferrule with                             Clip-On Stop
                Stainless Washer                                                                                              Stainless Washer
                              Lag Eye                                                                                                        Lag Eye
                               Fixed Jaw                                      Adjust-A-Body TM                                                    Adjust-A-BodyTM with
                                                                              with Hanger Bolt                                                    Threaded Eye
                                                                                                                                                                         SPIRAL STAIRS
                                                                                                                                                                          BALCONIES
INVISIWARE® RECEIVERS, RADIUS FERRULES AND                                      CABLE SUPPORT
CLIP-ON STOP WITH WOODEN END POSTS                                              1
                                                                                 /4" × 1" flat bar.
The Invisiware® Receiver, Radius Ferrule and Clip-On Stop may be                Available in Steel
used with wooden end posts. We recommend one of these ways to                   and Satin Finished                      Cable
accomplish this.                                                                Stainless Steel.                       Support
Surface Mount: Drill a hole in the post to accept the selected fitting
                                                                                                                                                                         ALUMINUM
                                                                                                                                                                         RAILINGS
such that the head sits on the outside of the post.                                                                                  Cable supports are
                                                                                                                                     used to prevent the
Counter Bore: Drill a counter bored hole to accept the appropriate                                                                   cable from biting into
fitting such that the head lies below the face of the post.                                                                          the wood post – when
Stainless Steel washers – page 58 – are required. They are supplied                                                                  tensioning – where the
with the Clip-On Stop but are to be purchased separately for the                                                                     cable enters or exits at
Invisiware® Receiver and Radius Ferrule.                                                                                             an angle.
Refer to page 258 for installation information.
                                                                                                                                                                         BRASS / SS
                                                                                                                                                                          FITTINGS
                                  Invisiware                                    DRILL GUIDE
                                                                                          Use Drill Guide to locate and
                                   Receiver
                                                                                          drill the pilot holes necessary
                                                                                              for your subsequent holes
                                                                                              and counter bores. Simply
                                                                                            clamp to post and drill. It is
                                Invisiware                                                      best to drill one side and
                              Radius Ferrule                                                         then the other. When
                                                                                                ordering, allow space for
                                                                                                 clamps. 6" overall length
                                                                                                    drill included that may
                                                                                                      be used to drill your
                                    Clip-On                                                           cable through holes.
                                     Stop
Note: ACQ pressure treated lumber is now being used in many parts               Download the Drill Guide Order Form and Cable Support Order
of the country. Use only stainless steel or galvanized hardware with            Form from www.wagnercablerailing.com or contact Wagner.
ACQ treated lumber.
                                                                                                                                                 grommet.
                Before beginning your project, download the Design and Fabrication Guide at www.wagner-
                cablerailing.com and review installation instructions on pages 258 to 271 of this catalog.                  Installation Tool             CRGIT
                                                                                                                           CABLE CUTTER
                                                                                                                           To be used to cut cable up to 1/4". Proper
                 Model 610 Swager             CR610                                                                        leverage is required. Either lay cable on a
                 Rental Kit*                  CRWAGNER610                                                                  table below your waist or on the ground.
BRASS / SS
 FITTINGS
                * Rental kits include: Swager, Air Over Hydraulic Pump,                                                    Use both hands to operate.
                  Cable Gripping Pliers, Allen Wrench, Cable Cutter,       Electric Hydraulic Pump        CRHPE
                  Marking Pen, Radius Ferrule Gauge, Safety Glasses,
                  Grommet Tool Set, Instruction Manual and Tool Box.
                                                                          RADIUS FERRULE/CLIP-ON STOP
                                                                          GAUGE
                                                                          Use this gauge to confirm that your fittings
                CABLE TENSIONING GAUGE                                    have been properly swaged. If the swaged
                Check the tension on your cables with this                fitting does not fit the appropriate slot, the   Cable Cutter for 1/8" - 3/16" cable CRCC
                simple to use gauge.                                      fitting is not suitable for use.                 Cable Cutter for 1/4" cable         CRCC12
                 /8" Cable
                 1
                                                      CR91
                 /16" - 1/4" Cable
                 3
                                                      CR90                 Measuring Gauge               CRMG               Push-Lock Tool Kit           CRPLTC
                                                                                                                                                                WAGNERAIL
loaded from our website.                                             changes to this product line.
                                                                                                                                                                 SYSTEM
                       Invisiware Receiver
                                                                                                                                                                RAILING
                    Invisiware Radius Ferrule                                                    Invis
                                                                                                                                                                GLASS
                                                                                                      iware
                                                                                                                 Swa
                        Push-Lock Fitting                                                                               ging
                                                                                                                               Stud
                                                                                                         Clip-
                          Clip-On Stop                                                                          On S
                                                                                                                        top
                                                                                             Invis
           Adjust-A-Body with Concrete Bolt Tensioner                                                iware
                                                                                                                 Radi
                                                                              Adju                                   us F
                                                                                  st-A-                                        errul
                                                                                                                                     e
                                                                                                                                                                RAILING
                                                                                       Body
                                                                                                                                                                CABLE
                 Adjust-A-Body with Hanger Bolt                                                   with
                                                                                                         Thre
                                                                                                                 aded
                Adjust-A-Body with Threaded Bolt                                                                         Eye
                                                                                                                                and
                                                                                          Adju                                         Thre
                                                                                                  st-A-                                       aded
                Adjust-A-Jaw with Threaded Tab                                                            Body                                       Tab
                                                                                                                  with
                                                                                                                         Hang
                                                                                                 Fixe                            er Bo
                   Adjust-A-Jaw with Lag Eye                                                             d Ja                            lt
                                                                                                                                                                SPIRAL STAIRS
                                                                                                             w wi
                                                                                                                   th La
                                                                                                                                                                 BALCONIES
                                                                               Push                                           g Ey
                                                                                      Lock                                         e
                     Fixed Jaw with Lag Eye                                                  with
                                                                                                    Thre
                                                                                                            aded
                          Inside to Inside                                        Push                              Eye
                                                                                          -Loc                             and
                         Outside to Inside                                                    k wit                         Thre
                                                                                                     h Th                        aded
                                                                                                          read                        Tab
                        Outside to Outside                                                                      ed E
                                                                                                     Insid            y e a
                                                                                                           e to
                                                                                                                 Insid nd Lag E
                                                                                                    Outs               e            ye
                                                                                                          ide t
                                                                                                                                                                ALUMINUM
                                                                                                                                                                RAILINGS
                                                                                                    Outs        o Ins
                                                                                                         ide t        ide
                                                                                                               o Ou
                                                                                                                    tside
                                                                                                                                                                BRASS / SS
                                                                                                                                                                 FITTINGS
               BEFORE YOU GET STARTED                                                     Cable Grip Locking Pliers. To grip the cable while tensioning the
                                                                                          end fittings without damaging the cable. (Available from the factory.)
               Rail Finish
               If your rail is to be painted, powder coated or otherwise finished in      Push-Lock Tool Kit. Includes Cable Grip Pliers and Cable Cutter.
GENERAL
               any way, we strongly recommend that you apply the finish after all
  INFO
                                                                                          swaged fitting. (“go” gauges for this purpose are normally included
               In areas prone to tampering, a permanent setting thread sealant is
   INFO
                 CRAJTE6
 CODES
                                                                                              Grommet                                 Grommet
                                                                                                                                                 Installation Tool
               Cable Cutters. CRC9 for cables up to 3/16"; CRC12 for cables larg-
      INDEX
               er than 3/16".
               Air Compressor. Minimum 5.8 cfm at 90 psi – not to exceed 140                   Large Lip                             Large Lip
               psi – and a minimum 20 gallon tank. Air pressure should be regu-
               lated not to exceed 140 psi.
               Ultra-tec® Portable Pneumatic/Hydraulic Swager. If you are rent-           Installing Cable
               ing one from Wagner, be sure to specify the uncoated diameter of           MEASURING AND INSTALLING CABLE
               the cable you are swaging, so the correct swager will be supplied.         Horizontal Railings, Measuring Cable Lengths
               Rented swagers generally come with most other special tools                If you have ordered your cables cut to length from the factory, you
               required to field swage and install cable, including hose fittings,        can skip this section on Measuring Cable Length.
               cable grip locking pliers, cable cutter, and go gauge for measuring            A. Measure the length of the run from the outside of one termi-
               the swaged diameter of Invisiware® Radius Ferrules. A pre-tension-                nating end post to the outside of the other terminating end
               er can also be furnished upon request.                                            post. Over estimate as shown, when corners are involved.
               Ultra-tec® Pre-tensioning Tool (optional). Since some Invisiware®                 See Figures A & B on next page. Note that Post “A” is always
               hardware has a minimum of take-up on longer runs (over 30 feet)                   the first end to which hardware is attached. When only one
               you may want to use a pre-tensioning tool. In ordering, be sure to                end has a tensioning device (Invisiware® Receiver or Adjust-
               specify the cable diameter you will be using it with.                             A-Jaw™ Tensioner), that tensioning device is attached to Post
                                                                                                 “B” and the non-tensioning device is attached to Post “A”.
                                                                                                 Post “B” is always a tensioning end.
                                                                                                                                                     ERALINFO
                                                                                                                                                     GEN-
                                                                                  from the back side, until the fitting’s head with washer rests
                                                                                                                                                       GENERAL
                                                                                  against the back side of the post (or in the counterbore if
                                                                                  applicable).
                                                                               Where Invisiware® Receivers are being used, swage the Stud
                                                                               onto the end of the cable to be attached to Post “A” (see
                                                                               “Swaging Instructions”).
                                                                                                                                                     TECHNICAL
                                                                                                               1          3
                                                                                                                   /2"        /4"
                                                                                                                                                        INFO
                                                                         Where Adjust-A-Jaw™ or Adjust-A-Body™ Type Tensioners are
                                                                         being used, slide the Body onto the cable and swage the Ferrule
                                                                         onto the end of the cable to be attached to Post “A” (see “Swaging
                                                                                                                                                     BUILDING
                                                                         Instructions”).
                                                                                                                                                      CODES
                                                                                                                                                     SPECS
                                                                                                                                                     GUIDE
                                                                         Where Ultra-tec® Fixed Jaws are being used, slide the Fixed Jaw
                                                                         onto the cable and swage the Ferrule onto the end of the cable to be
                                                                         attached to Post “A” (see “Swaging Instructions”).
                                                                                                                                                     INSTALLATION
      C above). A lawn or swept concrete surface would be fine.
                                                                                                                                                        GUIDES
   C. Cut cable to length, using Cable Cutter.
NOTE: Make sure you have a positive holding device at the zero
end. Cutting the cables takes very little time. It is best to have one
person stand at the zero mark while another operates the cable cut-
ter at the cut mark.
Installing Cable
                                                                               NOTE: If you are using Ultra-tec® “Clip-on” Fixed Jaws with
   A. Unless already swaged, swage the fittings to be used on                  the Ferrule already swaged onto the cable or Ultra-tec® “Clip-
                                                                                                                                                     INDEX
      Post “A” onto one end of the cut cables (See “Swaging                    on” Stops, you will have to feed the cable from the Post "B"
      Instructions” section of these instructions).                            end through all intermediate posts to Post "A," before
       NOTE: Where only one end of the cable has an adjusting fit-             installing the Fixed Jaw onto the Post "A" end of the cable.
       ting (Invisiware® Receiver or Adjust-A-Jaw™ Tensioner), we              See “Ultra-tec® Clip-On Fixed Jaw Installation Instructions” or
       recommend that you swage the unadjusting end, Post “A,”                 ”Ultra-tec® “Clip-on Stop Installation Instructions” elsewhere in
       first (before the cables are strung) and the adjusting end,             this guide for attaching the Fixed Jaw or “Clip-on Stop” to the
       Post “B,” last (after the cables have been strung).                     cable.
   Where Invisiware® Radius Ferrules will be used:                          B. String Cable through intermediate posts and braces to Post
     1. Slide the Washer onto the cable.                                       “B.” If you are using the Radius Ferrule, see Fig. M; for other
     2. Swage the Radius Ferrule onto the end of the cable (see                devices, see Fig. M-A (shown on next page).
         “Swaging Instructions”).                                           C. Attach fittings to end Post “A.”
                                Post                                           If using Ultra-tec® Fixed Jaw, bolt the fitting to the tab, through
         Swaged Radius                                                         the hole in the structural tee, or the lag eye (in wood post) on
            Ferrule                                                            the end post, using the screws specified under “Materials
                    Washer
                                                     Cable                     Required.”
            Counterbored
             Hole In Pipe
                                                                                        Screw the lock nut onto the threads of the Clevis or Eye, then
                                                                                        hold the cable closely behind the body and turn the body by hand
                                                                                        a minimum of 8 turns onto the threaded end of the Clevis. (See
GENERAL
                                                                                                                                       CRDRIVERHB6 – may be
                                                                                                                                       used to facilitate tightening.
TECHNICAL
                                                                                        If you are installing into wood with a hanger bolt, screw the hang-
                                                                                        er bolt into a pre-drilled pilot hole in the post. Screw the lock nut
   INFO
                                                                                        onto the threads of the bolt, then hold the cable closely behind
                                                                                        the body and turn the body by hand a minimum of 8 turns onto
                                                                                        the threaded end of the bolt. (See note*).
BUILDING
 CODES
                                                                                        note*)
                                                                                        *NOTE: This will allow for maximum take-up. The fewer turns you
                                                                                        make at this step, the more thread that will be exposed when the
                                                                                        installation is complete. Each job is different, so we suggest that you
                                                                                        string and lightly tension one cable between end posts, to determine
                                                                                        how many turns you will make in turning the body onto the male
                                                                                        threaded end in order to minimize the amount of exposed thread at
                                                                                        both ends.
                                                                                        If using an Invisiware® Receiver, slide the washer over the body
                                                                                        of the Receiver, then feed the Receiver through the hole in back
                                                                                        of the post and into the hole on inside wall of the post (metal). If
                                                                                        you have a metal double post end post construction, be sure to
                                                                                        place spacers between the double posts, as you feed the fitting
                     If you are installing the tensioner using tabs, holes in a         through. By hand, screw the Receiver onto the threaded Stud at
                     structural tee or lag eyes (in wood) attach the clevis portion     least 6 full turns.
                     of the fitting to the tab, lag eye or through the hole in struc-
                     tural tee on the end post, using the screws specified under
                     “Materials Required.”
                                                                                                                                       GENERAL
                                                                        more thread exposed than necessary after tensioning. This
                                                                                                                                         INFO
                                                                        length can be altered to achieve the most favorable results.
                                                                                                                                       TECHNICAL
                                                                                                                                          INFO
                                                                          Receiver
                                                                          CRR6 = .75
                                                                          CRR8 = 1.00
                                                                          CRR12 = 1.00
   For wood posts, follow the same instructions, except you will
   have to feed the cable – with the Stud swaged on the end –
   through the post from the inside to meet the Receiver inside the
   post, where you will turn the Receiver onto the Stud using an
                                                                                                                                       BUILDING
   Allen wrench.
                                                                                                                                        CODES
   If you are using Invisiware® Radius Ferrule, make sure the fitting
   is through the hole in the back of the post with the head with
   washer resting against the back side of the post (or in the coun-
   terbore if applicable) as you proceed to the next step.
                                                                                                                                       SPECS
                                                                                                                                       GUIDE
                                                                                                                                       INSTALLATION
                                                                                                                                          GUIDES
                                                                                                                     CRR6
                                                                                                                     CRR8
                                                                                                                                       INDEX
   NOTE: If installing Invisiware® Receiver on a stairway, see "Using      the Receiver through the hole in the back of the post. If
   Invisiware® Receivers on Stairways" before proceeding.                  you have a double post end post construction, be sure to
Fig. S
                      until all cables have been installed between end posts “A”
  INFO
                      and “B.”
                      For wood posts using 3.50" long Receiver, follow the
                      same instructions                                                   CRAJ62
                                                                                          CRAJ82
                   4. Repeat above steps for each cable to be installed
                                                                                          CRAJ122
                      between end posts “A” and “B.”
                                                                                          CRAJTE6
TECHNICAL
                   5. After all the cables have been installed, tension the cable         CRAJTE8
                      to approx. 400 lbs. by holding the cable (using cable grip
   INFO
                                                                                      CRAJB6
                                                                                      CRAJB8
SPECS
GUIDE
INSTALLATION
                   er at Post “B”
                   1. Cut Cable at Post “B” End. (Assumes cable is already
                      attached to Post “A.”)If you are attaching the tensioner to a
                      tab, lag eye or hole in a structural tee, mark and cut the
                      cable at the location shown in relation to the center of the
                      mounting hole at Post ”B” (see Figure T). NOTE: this cut                 CRAJTB6
                                                                                               CRAJTB8
                      mark will allow for maximum take-up. However, it may leave
                      more thread exposed than necessary after tensioning. This
      INDEX
                                                                                                                                                         GENERAL
                                                                                        the threads of the bolt, then hold the cable closely behind
                                                                                                                                                           INFO
                                                                                        the body and turn the body by hand onto the threaded end
                                                                                        of the bolt at least 6 full turns.
                                                                                                                                                         TECHNICAL
        structural tee or lag eyes (in wood) attach the Clevis or
        Eye portion of the fitting to the tab, lag eye or through the
                                                                                                                                                            INFO
        hole in structural tee on the end post, using the screws
        specified under “Materials Required.”
                                                                                                                                                         BUILDING
                                                                                                                                                          CODES
                                                                                     4. Repeat the above steps for each cable to be installed. Do
                                                                                        not tension the cables, until all cables have been installed
                                                                                        between end posts “A” and “B.”
                                                                                     5. After all the cables have been installed, tension the cable
                                                                                        (to approximately 400 lbs.) with an open end wrench,
                                                                                        holding the cable with cable grip locking pliers to prevent
                                                                                        it from rotating. See “Tensioning Cables” for sequence
                                                                                                                                                         SPECS
                                                                                                                                                         GUIDE
        Screw the lock nut onto the threads of the Clevis or Eye,                       to use in tensioning cables.
        then hold the cable closely behind the body and turn the                     6. If tensioners are mounted to tabs, structural tees or lag
        body by hand onto the threaded end of the Clevis at least                       eyes, tighten the mounting screws.
        6 full turns.
                                                                                                                                                         INSTALLATION
                                                                                                                                                            GUIDES
        If you are installing into wood with a hanger bolt, screw the
        hanger bolt into a pre-drilled pilot hole in the post. Screw
        the lock nut onto the threads of the bolt, then hold the
        cable closely behind the body and turn the body by hand                      7. On all installations, tighten the lock nut against the body of
        onto the threaded end of the bolt at least 6 full turns.                        the fitting with an open end wrench.
                                                                                                                                                         INDEX
                                              Socket Nut Driver –
                                              CRDRIVERHB6 – may be             NOTE: In areas prone to tampering, the use of permanent setting
                                              used to facilitate tightening.   thread sealant is recommended for mounting screws and lock nuts.
               F. Tensioning cables
                                                                                                                   Using Lag Eye
               NOTE: Tension in sequence, beginning with cable nearest center of          Cable Diameter                                      Drill Size
                                                                                                                      Part No.
GENERAL
                                                                                                     /8"
                                                                                                     1
                                                                                                                       CRLE6                     17
                                                                                                                                                      /64"
                                                                                                 3
                                                                                                     /16 "             CRLE6                     17
                                                                                                                                                      /64"
TECHNICAL
                                                                                                     /4"
                                                                                                     1
                                                                                                                       CRLE8                      3
                                                                                                                                                      /8"
   INFO
                                                                                                                       Using
BUILDING
Part No.
                                                                                                                     CRAJB6
                                                                                                     /8"
                                                                                                     1                                           13
                                                                                                                                                      /64"
                                                                                                                     CRAJB6L
                                                                                                                     CRAJB6
                                                                                                 3
                                                                                                     /16"                                        13
                                                                                                                                                      /64"
                                                                                                                     CRAJB6L
SPECS
GUIDE
                                                                                                     /4"
                                                                                                     1
                                                                                                                      CRAJB8                      5
                                                                                                                                                      /16"
                                                                                                                                                                                                                    GENERAL
                                                                                                                                                                                                                      INFO
                                                                                                                                  At corners or turns of more than approximately 45 degrees, it is best
                                                                                                                                  to terminate your runs in each direction with an end post (minimum
                                                                                                                                  of a nominal 4x4). The following illustrations demonstrate how this
                                                                                                                                  is done. One such corner, however, may be designed using two
                                                                                                                                  posts on the corner and running the cables between the posts as
                                                                                                                                  illustrated below.
                                                                                                                                                                                                                    TECHNICAL
                                                                                                                                                                                                                       INFO
*Note: Do not counterbore if you are using CRR662 (31/2" long)
Receivers in a 4x4 (31/2") post on a pitch.
                                                                                                               For Counterbore
                                                    Drill Hole for                                             Diam of Hole for
                                                   Cable, Threaded      Diameter of Hole                        Flat Washer or
                                                                                                                                                                                                                    BUILDING
                                    Cable          Stud or Clip-On       for Receiver or    Use Stainless        Clip-On Stop
                                                                                                                                                                                                                     CODES
           Option                  Diameter              Stop            Radius Ferrule    SAE Flat Washer          Washer
                                                                                                                                                                                                                    SPECS
                                                                                                                                                                                                                    GUIDE
                                                               Hole Diameter Where Cables are supplied by Wagner
                                                                        with fittings swaged on both ends
                       Hole Diameter Where
                    Studs/Ferrules are swaged in                                             Using Ferrules for Clip-On Fixed
     Cable Size               the field                      Using Threaded Studs                 Jaws or Clip-On Stop
       1
          /8"                  5
                                 /32"                              11
                                                                      /32"                                17
                                                                                                             /64"
       3
         /16"                  7
                                 /32"                              11
                                                                      /32"                                17
                                                                                                             /64"
        1
          /4"                  9
                                 /32"                              15
                                                                      /32"                                25
                                                                                                             /64"
                                                                                                                                                                                                                    INSTALLATION
                                                                                                                                  A stainless steel flat bar (Cable Support) with holes for the cable to
Wood Rail Applications
                                                                                                                                                                                                                       GUIDES
                                                                                                                                  pass through is mounted on each surface where the cable enters or
A substantial end post is necessary, to prevent the end post from                                                                 exits the post at an angle, to prevent the cable from biting into the
bending, which will cause the cables to sag. In wood, a minimum                                                                   wood when it is tensioned. Cable Supports are available from
4x4 nominal – 31⁄2" square – end post is required. End posts must be                                                              Wagner.
securely fastened to the deck or other surface, to prevent the post
from coming loose with the forces applied through the tensioned
cables. Support members between end posts are also necessary. In
wood, we recommend support members running between posts,
such as a 2x4 secured to the inside of each post, so you are not
INDEX
               On a turn of less than approximately 45 degrees, you can run your        a) Field cut and swage or factory cut and swage fittings on the
               cables through a single post, but you will still need to use a Cable     cables.
               Support where the cable enters or exits the post at an angle, to pre-    When the fittings are swaged on at the factory, some fittings are larg-
GENERAL
               vent the cable from biting into the wood when it is tensioned.           er in diameter than the size of the holes you want to drill in your inter-
  INFO
               Configuration of Single Wood Corner Post                                 mediate members (posts or cable braces). The fittings illustrated
               The following illustrations demonstrate how the hardware can be          below, however, require relatively small holes in your intermediate
               used on a single corner post. They also illustrate how some hard-        members. If the hardware is swaged on at the factory and if the cable
               ware can be countersunk into the post or mounted flush with the          will pass through intermediate posts or cable braces, one end of
               back of the post. Not all combinations are shown here. If the hard-      each cable should have one of the following fittings. The holes in
               ware and cable run all the way through the post in one direction, you    your intermediate member will be drilled for the diameter of the
TECHNICAL
               will need to use a hanger bolt end or hardware that is mounted to a      swaged fitting passing through the intermediate member as shown
                                                                                        in the following illustrations:
   INFO
               lag eye for the perpendicular direction, as shown in the first three
               illustrations that follow.
BUILDING
 CODES
                                                                                                                                                  GENERAL
                                                                            from underneath the bottom rail. First, tension the cable near-
                                                                                                                                                    INFO
                                                                            est the center point between posts and/or cable braces. Then,
                                                                            tension the rest of the cables in sequence, by alternating from
                                                                            one side of the center cable to the other, as you move out-
                                                                            ward toward the posts and/or cable braces. (For tensioning
                                                                            sequence illustration, see “Tensioning Cables” in preceding
                                                                            Installing Cables Section of this guide.)
                                                                                                                                                  TECHNICAL
                                                                      Before you begin swaging
                                                                                                                                                     INFO
                                                                      NOTE: If you are using coated cable, be sure to strip the coating
                 Drilled holes to accept
                 Invisiware Receivers                                 from the end of the cable before swaging.
                                                                      If you are using the Adjust-A-Jaw™ or Adjust-A-Body™ Type
  B. *Measure out the cable on a rel-                                 Tensioner or Ultra-tec® Fixed Jaw fitting, make sure the cable has
     atively clean surface (see                                       been inserted through the body of the fitting prior to swaging the fer-
     Figure C). A lawn or swept con-                                  rule onto the cable. See illustrations below.
     crete surface would be fine. Cut
                                                                                                                                                  BUILDING
                                                                                                                                                   CODES
     cable to the length determined              Sch. 80 or
     in Step A above, using Cable                .250" wall
     Cutter.
     NOTE: Make sure you have a
     positive holding device at the
     zero end. Cutting the cables
     takes very little time. It is best to
     have one person stand at the
                                                                                                                                                  SPECS
                                                                                                                                                  GUIDE
     zero mark while the other oper-
     ates the cable cutter at the cut
     mark.
  C. *Swage a Stud onto each end of
     the cable (see “Swaging
     Instructions”).
                                                                                                                                                  INSTALLATION
                                                                      If you are using the Invisiware® Receiver or Welded Receiver
                                                                      (threaded receiver inside post), the Stud will be swaged onto the end
                                                                                                                                                     GUIDES
                                                                      of the cable and will install directly into the fitting.
                                                                      If you are using the Invisiware® Radius Ferrule or Clip-on Stop, the
                                                                      fitting will be swaged onto the end of the cable and no further oper-
                                                                      ation will be required.
                                                                      NOTE: Swage the fitting on one end of the cable only, before string-
                                                                      ing cables through posts and braces. Where only one end of the
                                                                      cable has an adjusting fitting (Invisiware® Receiver or Adjust-A-
                                                                                                                                                  INDEX
  D. Screw the swaged Stud on one end of the cable into the           Jaw™ or Adjust-A-Body™ Type Tensioner), we recommend that you
     threads in the top rail, until the threads on the Stud are not   swage the unadjusting end first and the adjusting end last (after the
     showing.                                                         cables have been strung).
  E. Slide the washer over                                            Swaging
     the body of the
     Invisiware® Receiver,                                               A. If you are using any fittings other than Radius Ferrules or Clip-
     then feed the Receiver                                                 on Stops, position the Ferrule or (threaded) Stud onto the
     through the hole in the                                                Cable as shown in Figure D below.
     bottom of the bottom
     rail.    Screw      the
     Receiver onto the
     threaded Stud. Do not
     tension the cables
     until all cables have
     been          installed
     between posts and/or
     cable braces.                                                           If you are using Radius Ferrules or Clip-on Stops, slide the
  F. Repeat above steps for each cable to be installed between               Cable into the open end of the fitting until it stops (see Figures
     posts.                                                                  E and I on next page).
                      1
                                                                                                             CRS4 & CRS6
                      CRF4 & CRF6 Ferrules), see Figure F.
   INFO
                      If you are using the Ultra-tec® Model 650 Portable Swager for
                      all sizes of cable, see Figure G. Make sure the die size you
                      use in the swager is the one marked for the diameter of the
                      cable onto which the fitting is being swaged.
                  C. Depress the foot pedal to introduce pressure into the swaging
                     tool. Do not let the dies close all the way on the first cycle.
BUILDING
 CODES
                  D. Release the foot pedal and apply foot pressure in the oppo-
                     site direction (this will re-open the dies). Turn the fitting 45
                     degrees and repeat Step C. Do not let the die close all the
                     way.
                  E. Turning the fitting 45 degrees each time, swage the fitting, let-
                     ting the die close completely at least three more times.
               NOTE: When swaging a Stud, the non-threaded end of the Stud should face                   CRS4 & CRS6
               the end of the cable. When properly swaged, the Ferrule will look like Figure
SPECS
GUIDE
                            Ferrule                                          Stud
INSTALLATION
   GUIDES
Fig. H Fig. J
                                                                                Diam of Swaged
                                                           For Cable            Portion of Fitting
                 Radius Ferrule       Clip-On Stop         Diameter                Should be
                  CRRF4 or           CRCOS4 or            1
                                                              /8" or 3/16"       .250" Max.
                   CRRF6              CRCOS6
                    CRRF8                 NA                     1
                                                                     /4"         .375" Max.
                  CRRF10 or
                                          NA              5
                                                              /16" or 3/8"       .500" Max.
                   CRRF12
                                                                                                                                GENERAL
   A. Swage the Stud onto the end of the cable to be installed at the bottom of the stairway. See “Swaging Instructions.”
                                                                                                                                  INFO
   B. Grip the cable with cable grip locking pliers approximately 1/8" from the swaged Stud. Screw the Receiver onto the Stud
      for leverage, and bend the cable by hand to the approximate angle desired. This bend does not have to be precise.
                                                                                                                                TECHNICAL
                                                                                                                                   INFO
                                                                                                                                BUILDING
                                                                                                                                 CODES
                                                                                                                                SPECS
                                                                                                                                GUIDE
   C. Install the Receiver in the post at the bottom of the
      stairway, following the instructions in the Installing
      Cable section for installing Invisiware® Receiver at Post
      A. Make sure the stud is flush with the outside wall of
      the post. See illustration at right.
                                                                                                                                INSTALLATION
                                                                                                                                   GUIDES
   D. Pull the cable to the hole in the post at the top of the
      stairway where the Receiver will be installed on the
      other end of the cable. Mark the cable at the center
      point of the hole. See illustration to the right.
   E. Swage the Stud onto the end of the cable with the
      threaded end at the mark made in Step D. See
                                                                                                                                INDEX
      “Swaging Instructions” and illustration at right. Cut off
      any excess cable, leaving a small "tail" out of the end
      of the Stud.
               Push-Lock™ Fittings Installation Instructions                                5. Pull cable to set gripping action of the Push-Lock™ Fitting.
                  A. Instructions in this section apply if the cables are sup-
                     plied with excess length and you will be cutting the
GENERAL
                        posts), then slide the Push-Lock™ Fitting into the hole in       B. This section applies if your cables have been cut to
                        your end post with the hole in the fitting facing the inside        length with a tensioner swaged on one end. If they are
                        (cable side) of the post. If you are using the Push-Lock™           supplied with excess length to be cut to size during installa-
                        Fitting with Threaded Eye, attach the fitting to the end post.      tion, see Section A above.
                                                                                            Important Note: Be sure to run the bare end of cable
                                                                                            through all of your intermediate posts, before installing
                                                                                            the Push-Lock™ Fitting. Do not install the tensioner on
                                                                                            the other end, until you have installed the Push-Lock™
SPECS
GUIDE
                                                                                            Fitting.
                                                                                            1. Make sure the holes are drilled properly in the end post
                                                                                               where you will be installing the Push-Lock™ Fitting.
                     3. Pull the cable tight and mark the cable at a point ½" from             If you are installing the Push-Lock™ Fittings in a metal
                        the shoulder at the cap end of the Push-Lock™ Fitting or               railing, see Metal Railings/Hardware Mounting
                        from the eye end of the body of the fitting. Cut the cable at          Holes/Boring Guide for boring instructions for your end
INSTALLATION
                                                                                                   A. Run the cable into the end post and push the cable
                     4. Push the cable into the hole in the Push-Lock™ Fitting as                     into the Push-Lock™ Fitting as far as it will go –
                        far as it will go (approximately 11⁄16")                                      approximately 11⁄16";
POST
WASHER
                                                                                                                                                     GENERAL
                                                                                                                                                       INFO
                                                                               1. Drill 17/64” (.266”) hole all the way through the post.
                                                                               2. If you wish to countersink the Stop in a wood post, then
                                                                                  drill a 15/16" (.938”) hole to a depth of 3/16” in the back side
                                                                                  of the post. If you are using round tube or steel pipe, see
                C. Pull the cable with the Push-Lock™ Fitting attached            Fabrication Instructions. There should be a 17/32” (.531”)
                   so that the fitting rests firmly against the back side
                                                                                  hole counterbored to a .100” depth, so the full diameter
                                                                                                                                                     TECHNICAL
                   of the post.
                                                                                  of the Washer will rest on a flat surface in the pipe.
                                                                                                                                                        INFO
                                                  POST                         3. From the inside side of the post, slide the cable through
                                                                                  the hole, Stop end first, and out the back side of the
                                                                                  post.
                                                                                                                                                     BUILDING
                                                                                                                                                      CODES
          If you are using the Push-Lock™ Fitting with Threaded Eye:
                                                                               4. Slide the Washer over body of the Stop.
                A. Push the cable into the Push-Lock™ Fitting as far
                   as it will go (approximately 11⁄16").
                                                                                                                                                     SPECS
                                                                                                                                                     GUIDE
                B. Pull cable to set gripping action of the Push-Lock™
                   Fitting.
                                                                               5. Force the Clip into the slot in the Stop, and press it in
                                                                                  by hand. Press Clip with pliers to secure it in slot.
                                                                                                                                                     INSTALLATION
                                                                                                                                                        GUIDES
                C. Attach the fitting to the end post.
                                                                                                                                                     INDEX
                                                                                  of the cable.
          3     Install the tensioner on the other end post, and tension
                the cables.