0% found this document useful (0 votes)
83 views10 pages

Pressure Level Transmitter

The document discusses pressure level transmitters that can be used in various industrial applications. Key points: 1) Pressure transmitters use a piezoresistive Wheatstone bridge to convert applied pressure into an electrical signal. 2) Models are available with different housing materials, pressure ranges, output connections, and wetted materials to suit diverse industrial environments and applications. 3) Transmitters provide a 4-20mA output signal proportional to pressure that can interface with indicators, recorders, controllers, and other devices.

Uploaded by

dtoxid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
83 views10 pages

Pressure Level Transmitter

The document discusses pressure level transmitters that can be used in various industrial applications. Key points: 1) Pressure transmitters use a piezoresistive Wheatstone bridge to convert applied pressure into an electrical signal. 2) Models are available with different housing materials, pressure ranges, output connections, and wetted materials to suit diverse industrial environments and applications. 3) Transmitters provide a 4-20mA output signal proportional to pressure that can interface with indicators, recorders, controllers, and other devices.

Uploaded by

dtoxid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

Pressure Level Transmitter

PRODUCT INTRODUCTION

FEATURES C
H
1

C
H
1

C
H

1. There are various types of transducers, such as:


2

transducer with extension cable/tube, Anti-corrosive C


H
2

type, flange type & pressure transducer.


FlneTek

Panel Meter
2. Can be equipped with digital panel meter, recorder,
PLC, signal controller.
3. The metal diaphragm is suitable in various environ-
ments such as weak acid and alkaline liquid or
sewage water treatment.
4. Our internal temperature compensation ensures long RECORDER

lasting reliability.
5. Available in varies flange/screw sizes.

COMPUTER
THEORY
A pressure sensor is made up of a piezoresistor
Wheatstone bridge. ALARM
Fig. (1)
As shown in fig.2, the pressure is applied to the
diaphragm and passes through the silicon oil onto
the Wheatstone bridge.

When the liquid pressure acts directly on the front


face of diaphragm, the Wheatstone bridge will
creates a differential voltage. This voltage
difference will then be amplified to obtain a current
signal of 4-20mA. When this current output is P = qHH
connected to an analog meter, we can scale
P : Pressure
properly to read the level of the applied liquid in a
container or a vessel. H: The level of liquid
q : Pressure constant
The formula used here is: P= q x H

Where P is pressure, q is pressure constant and H Piezoresister


is the level of liquid in a container. Silicon oil
Thin diaphragm

APPLICATIONS
Fig. (2)
1. EC1100 is a liquid measurement device which can
be used in a variety of environments, including water-
agitation environments.
2. EC1200 can withstand high temperature liquid envi-
ronment.
3. The Standard Flange Type, EC1210 can be used in
liquid & gas pressure measurement environments
(i.e., mildly corrosive environments).
4. EC1300~1320 type is suitable for measurement of
very deep water, such as measurement of reservoirs.
5. EC1500 is suitable for pressure measurement or con-
trol devices such as those found in hydraulic and
pneumatic machines.

1
FlneTek
SPECIFICATION

f70 f70

70 70
1/2"PF
1/2"PF

1-1/2"x5kg/cm
2 247
4-f19 70 177
f95PCD
1-1/2"PT
4- f15

f140 f98
Dimensions

L=4M(MAX)
L=4M(MAX)

f17.2 (TUBE)
(unit:mm) f17.2 (TUBE)

f105PCD 1-1/2"x10kg/cm2 1/2"PF

f34 f34

EC1100 EC1110
Model No. EC1200 Hi-Temp.Flange Type
Extension Tube Flange Type Extension Tube Screw Type
Housing Aluminum, IP65 Aluminum, IP65 Aluminum, IP65
material
Pressure
0.1, 0.2, 0.4 bar 0.1, 0.2, 0.4 bar 0.1, 0.2, 0.5, 1, 2, 5, 10 bar
range

0~1M,0~2M,0~5M,0~10M,
Measuring 0~1M,0~2M,0~4M 0~1M,0~2M,0~4M
0~20M,0~50M,0~100M
range (assumed with the water S.G:1) (assumed with the water S.G:1)
(assumed with the water S.G:1)

Linearity 0.3%FS 0.3%FS 0.3%FS


Long term
stability <0.1% <0.1% <0.1%

Operating temp -10~80BC -10~80BC -10~150BC

Ambient temp 60BC 60BC 60BC

Supply voltage 13~36 Vdc 13~36 Vdc 13~36 Vdc

4~20mA,Loop resistance 4~20mA,Loop resistance 4~20mA,Loop resistance


Output
should be less than 500 W should be less than 500 W should be less than 500 W

Connection 1-1/2" x 5kg/cm 2 1-1/2" PT 1-1/2" x 10kg/cm 2

Wetted material SUS 304/316 SUS 304/316 SUS 304/316

Weight approx. 4.2kg (L=1M) approx. 4kg (L=1M) approx. 1.8kg (L=1M)

※Special size flange and screws are available.


※OEM/ODM is welcome.
2
f70
f70

70
70
1/2"PF 1/2"PF

110 1-1/2"x5kg/cm
2

40 70 f95PCD 1-1/2"PT
4- f15
4- f15

Dimensions f8 (Cable PVC)

L=100M(MAX.)
f70

L=100M(MAX.)
f8 (Cable PVC)
(unit:mm)

PCD f95
1-1/2"x5kg/cm2 1/2"PF

f34 f34

EC1210 EC1300 EC1310


Model No. Flange Standard Type Extension Cable Flange Type Extension Cable Screw Type
Housing Aluminum, IP65 Aluminum, IP65 Aluminum, IP65
material
Pressure
0.1, 0.2, 0.4 bar 0.1, 0.2, 0.5, 1, 2, 5, 10 Bar 0.1, 0.2, 0.4, 1, 2, 5, 10 Bar
range

0~1M,0~2M,0~5M,0~10M, 0~1M,0~2M,0~4M,0~10M,
Measuring 0~1M,0~2M,0~4M
0~20M,0~50M,0~100M 0~20M,0~50M,0~100M
range (assumed with the water S.G:1)
(assumed with the water S.G:1) (assumed with the water S.G:1)

Linearity 0.3%FS 0.3%FS 0.3%FS

Long term
stability <0.1% <0.1% <0.1%

Operating temp -10~80BC -10~80BC -10~80BC

Ambient temp 60BC 60BC 60BC

Supply voltage 13~36 Vdc 13~36 Vdc 13~36 Vdc

4~20mA,Loop resistance 4~20mA,Loop resistance 4~20mA,Loop resistance


Output
should be less than 500 W should be less than 500 W should be less than 500 W
Connection 1-1/2" x 5kg/cm 2 1-1/2"x5kg/cm2 1-1/2"PT

Wetted material SUS 304/316 SUS 304/316 SUS 304/316

Weight approx. 1.5kg approx. 2.8kg (L=1M) approx. 2.9kg (L=1M)

※Special size flange and screws are available.


※OEM/ODM is welcome.
3
FlneTek
18 11 58 27
L=100M(MAX)

L=6M(MAX)
f8 (Cable PVC) f8 (Cable PVC)
Dimensions 34
50
(unit:mm)
1/2"PT
10.5
16
22

f34 f27

EC1320 EC2500 EC1500


Model No. Extension Cable Type Extension Cable Type Pressure Transducer
Pressure
0.1,0.2,0.5,1,2,5,10 bar 0.25, 0.4, 0.6 bar 0.1,0.2,0.5,1,2,5,10,20,50,100 bar
range
0~1M,0~2M,0~5M,0~10M,
Measuring 0~2.5M,0~4M,0~6M
0~20M,0~50M,0~100M
range (assumed with the water S.G:1)
(assumed with the water S.G:1)

Linearity 0.3%FS 0.3%FS 0.3%FS

Long term
stability <0.1% <0.1% <0.1%

Operating temp -10~80BC -10~80BC -10~80BC

Ambient temp N. A. N. A. 60BC

Supply voltage 13~36 Vdc 13~36 Vdc 13~36 Vdc

4~20mA,Loop resistance 4~20mA,Loop resistance 4~20mA,Loop resistance


Output
should be less than 500 W should be less than 500 W should be less than 500 W

Protection 1/2" PT

Wetted material SUS 304/316 SUS 316 SUS 304/316

Weight approx. 0.8kg (L=1M) approx. 0.8kg (L=1M) approx. 250g

※Special size flange and screws are available.


※OEM/ODM is welcome.
4
FlneTek
INTERNAL WIRING

1. Make sure the power is turned off. Connect them as


show in fig.3, 4 or 5 (depend on which model you pur- EC1500 TYPE
chased).
1. Remove the cover of plug and connect cable to the
2. Make sure the outlet breather capillary is open for air terminal of plug.
to flow freely.
3. Please tighten cover and cable gland after wiring fin-
ished.
Ground
4. The cable should be at least 18 AWG or 16 AWG. Plug

1 2 Fasten nut
+24V O/P
3 O/P
Break White Cover
Breather Ground +24Vdc
capillary Green

Break
Shield wire

White
Fig. (5)
+24V O/P

2. When wiring is finished, assemble the plug with cover.

Plug Cover
Fig. (3)

EC1100, EC1110, EC1300, EC1310


Screw

SPAN
ZERO
Socket Plug

O/P

+24V
Shield wire Breather
capillary
Fig. (6)

Fig. (4)
EC1200, EC1210

5
FlneTek
EXTERNAL WIRING

1. For FineTek Panel Meter, please refer to the


wiring diagram attached. As for other brands of
panel meter, please refer to its respective EC1100~1110,1300~1310
operation manual for their wiring diagram. Inside view

2. Wiring connection should be kept away from high


voltage cable, (e.g. Power cable.) to prevent
Shield wire
interference from high voltage.
+24V O/P
3. Resistance in the circuit should be avoid for
+24V
wiring connection in order to keep operating
voltage higher than 13Vdc Breather A input
capillary
4. Wiring should be used in shielded insulated
cable.

5. If the panel meter does not supply 24Vdc power 4~20mA loop
supply to the sensor, additional power supply is
needed as according to Diagram 8. If installing 2
Panel meter
panel meters at different location, please refer to
diagram 9 for wire connection.
Fig. (7)

Extra

Pressure Sensor DC Power Supply

+ GND
+24V Digital panel meter
A input w/o extra power supply
O/P
to sensor probe

Fig. (8)

Meter1 Meter2

DC Power Supply
Pressure Sensor A input GND A input GND
+
+24V

O/P

Fig. (9)

6
FlneTek
INSTALLATION
1. The transducer with extension cable & types are
equipped with an electrical housing standing
vertically and with a screw-type of cap on top. EC1100 EC1300 EC1320

2. The flange type transducer is equipped with a


side mounted electrical housing.

3. A special type of cable is used in the transducer


with extension cable. Please note that this cable
comes with 3 multi-thread copper wire and a
breather capillary. Therefore, any bending of the
cable is not recommended. Otherwise, the
measurements will not be accurate.

4. It is recommended that you use EC1200, when


the pressure level measurement of solvent is
implemented.

5. Do not use liquid that will crystallize or solidify in


all of your pressure transducer.

6. All our pressure transducers are designed to


perform in an environment with temperature
equal to or less than 80BC (except EC1200). If
the desired operation temperature is more than
80?C, please consult with our business
representative.

7. The tank or vessel should not be vacuum or EC1110 EC1310


where no pressure can be applied to the tank or
vessel.

8. Handle the sensor probe with care. The sensor


probe is extremely delicate, any extra vibration
or shock will damage it.

9. Do not use high pressure jet of water to wash the


sensing diaphragm.

EC1200

EC1500

7
FlneTek
ADJUSTMENT (FOR ZERO-SPAN)

1 Adjust the trimmer "ZERO" while the tank is empty to SPAN


make sure the current output was expected to reach
4mA.
1 Adjust the trimmer "SPAN" while the tank is full to
make sure the current output was expected to reach
20mA.
1 Since Zero & Span adjustment were all done in the
factory before shipment, do not perform the above
adjustments unless it is really necessary.
1 Adjust range: (SPAN) 18~24mA, (ZERO) 3~5mA. ZERO
1 If the sensor output is not a standard 4~20mA signal
while liquid level changes between empty and full, we The electrical housing for transducer
recommend you to use with the PM series digital with flange.
meter, because which equipped with a built-in pro-
grammable input (0~25.5mA) to allows the user to set
his configuration. This special function will keep the
reading of meter correspond to the any different input
signal. More information please refers to Panel Meter SPAN
series catalog.

ZERO

The electrical housing for pressure


transducer.

Pressure Unit Conversion Constants

PSI KPa mbar cmH2O mmHg kgf/cm2

PSI 1 6.89 68.95 70.31 51.71 70.31x10-3

KPa 0.15 1 10 10.2 7.5 1.02x10-2

mbar 1.45x10-2 0.1 1 1.02 0.75 1.02x10-3

cmH2O 14.22x10-3 98.07x10-3 0.98 1 0.74 10-3

mmHg 19.34x10-3 13.33x10-2 1.33 1.36 1 1.36x10-3

kgf/cm2 14.22 98.07 980.67 1000 735.56 1

1 MPa=10.2kgf/cm2=145 PSI 1 kgf/cm2=0.098MPa=14.22 PSI

8
FlneTek
HOW TO MAKE YOUR ORDER

EC 1 1 0 0 E M ( 0 1 0 0 )
MODEL
110: Extension Tube Flange Type 131: Extension Cable Screw Type
111: Extension Tube Screw Type 132: Extension Cable Type
120: Hi-Temp. Flange Type 150: Pressure Transducer
121: Flange Standard Type (Custom-made)
130: Extension Cable Flange Type 151: Pressure Transducer
175: Extension Type
WETTED MATERIAL
0: SUS304 6: SUS316 E: PTFE
(EC130 Extension Cable Type )

CONNECTING TYPE
B: 1/2" (15A) I : 4" (100A) M: 5 kg/cm2 U: NPT
C: 3/4" (20A) J: 5" (125A) N: 10 kg/cm2 W: PN10 (10Bar)
D: 1" (25A) K: 6" (150A) O: 150 Lbs X: PN16 (16Bar)
E: 1-1/2" (40A) S: Others P: 300 Lbs Y: PN25 (25Bar)
F: 2" (50A) Q: PT Z: PN40 (40Bar)
G: 2-1/2" (65A) R: PF(G) S: Others
H: 3" (80A) T : BSP -: None

PROBE LENGTH (unit: m)


0050: below 0.5m
0100: 1m
0150: 1.5m 0.5m per Unit

1 0 0 EM( 0 ) ( 0 1 0 0 )
EC 2 5
MODEL
250: Extension Cable Type
PRESSURE (BAR)
X25=0.25bar X4=0.4bar X6=0.6bar

PROBE LENGTH (unit: mm)


0050: below 0.5m
0100: 1m
0150: 1.5m 0.5m per Unit

*Tolerance of the total product length is A5mm


*Characteristics, specifications and dimensions are subject to change without notice.
*Please contact your nearest distributing office for further informations.