TPS20                                  Series
Features
       •• DC4-20mA analog signal (2-wire) transmission by
         measuring pressure of liquid, gas, and oil.
       •• High accuracy (±0.3% F.S.) with stainless steel
         diaphragm for various measurement
       •• Various model for installation environments
       	 : Head type, DIN connector type,
           connector cable type
       •• Built-in zero-point, span adjustment (head type)
                                                                                     [Head type] [DIN connector type]   [Connector cable type]
               Please read “Safety Considerations” in operation manual
               before using this unit.
       Ordering Information
         TPS20            G      1      5        F8   (0 to 5kgf/cm2)
            ①             ②      ③      ④        ⑤             ⑥
                                            Description
      ① Item                                TPS20         Pressure Transmitter
                                            G             Gauge pressure
      ② Measurement presssure
                                            A             Absolute pressure
                                            1             Head type
      ③ Cable                               2             DIN connector type
                                            3             Connector cable type
                                                          Gauge pressure                           Absolute pressure
                                            1             0 to 0.2kgf/cm2                          -
                                            2             0 to 0.5kgf/cm     2
                                                                                                   -
                                            3             0 to 1kgf/cm2                            0 to 1kgf/cm2
                                            4             0 to 2kgf/cm   2
                                                                                                   0 to 2kgf/cm2
                                            5             0 to 7kgf/cm   2
                                                                                                   0 to 7kgf/cm2
                                            6             0 to 10kgf/cm2                           0 to 10kgf/cm2
                                            7             0 to 20kgf/cm2                           0 to 20kgf/cm2
                                            8             0 to 35kgf/cm2                           0 to 35kgf/cm2
                                            9             0 to 70kgf/cm      2
                                                                                                   -
      ④ Pressure range                      A             0 to 100kgf/cm2                          -
                                            C             0 to 200kgf/cm2                          -
                                            F             0 to 300kgf/cm2                          -
                                            H             0 to 350kgf/cm2                          -
                                            M             -760mmHg to 0kgf/cm2                     -
                                            O             -760mmHg to 1kgf/cm2                     -
                                            Q             -760mmHg to 7kgf/cm    2
                                                                                                   -
                                            V             -760mmHg to 10kgf/cm2                    -
                                            X             -760mmHg to 20kgf/cm2                    -
                                            Y             -760mmHg to 35kgf/cm2                    -
                                            Z             Others
                                            P2            R1/2 (with adapter, PT)
                                            P8            R3/8 (with adapter, PT)
      ⑤ Pressure port
                                            F8            G3/8 (standard, PF)
                                            ZZ            Others
                                                                                 1
      ⑥ User pressure range                               User pressure range
       1: Write the desired pressure range and it is the default of user pressure range. (select "Z" at ④Pressure range)
       For ordering cable, order as CID3-2, CID3-5, CLD3-2, CLD3-5. (sold separately)
F-7
                                                                                                  Pressure Transmitter
Dimensions                                                                                                                                                           A. Recorders
● Head type                                                                                          106                                               (unit: mm)
                                            24                                           34                      71                                                  B. Indicators
                                                                                   21         14
                                                                                                                                                                     C. Converters
                                                                                                                                                                     D. Controllers
                                                                                                                                         84
                                                                                         G3/8                                                                        E. Thyristor
                                                                                                                                                                        Power
                                                                                                                                                                        Controllers
                                                                                                                                                                     F. Pressure
                                                                                                                                                                        Transmitters
 ● DIN connector type                                                                                    104                                                         G. Temperature
                                                                                                                                                                        Transmitters
                                                                                        31          28                42
                                                                                    21       8                                                                       H. Accessories
                                            27
                                                                                                                                    46.5
                                                                                         G3/8
 ● Connector cable type                                                              31                    62              10
                                                                                   21         8
                                       22
                                                                                                                                                                     TPS30
                                                                                         G3/8                                   M12 Connector
 ※The standard pressure port for above is G3/8.                                                                                                                      TPS20
Connection Cable (Sold Separately)                                                                                                                                   KT-302H
                                                                                                                                                        (unit: mm)
● CID3-2 / CID3-5                                                                ● CLD3-2 / CLD3-5                                                                   PTF30
                                                  40                                                                            Ø14.8
                  M12
                                                                 Ø5                           M12
                                                                                                                                                Ø5
                                                                                                               27.5
                                                 Ø14.8                                                                      32
                                                          L(m)                                                                          L(m)
                                             Model       L (m)        Meterial                                        Model             L (m)        Meterial
                                             CID3-2      2                                                            CLD3-2            2
                                                                      PVC                                                                            PVC
                                             CID3-5      5                                                            CLD3-5            5
Connections
                                                         (brown) +V
                   Current amplifier
   Main Circuit
                                                                 +
                                                                     15-35VDC
                                                                 -
                                                         (blue) GND
                                                                                                                                                                             F-8
            TPS20                               Series
        Connector
          Head type                               DIN connector type                                Connector cable type
                                   Pin                                   Pin            Function                           Pin       Function
                                                                         1              +                                  1         +
                                   +
                                                                         2                                                 2         N.C
                                                                         3              N.C                                3         F.G.
                                                                                        F.G.                               4
          ※In case of head type, remove the top cover.
                                                                        KRN100
          ● Example of external connections
                                                          Terminal
                                                  +                                         -   +
                        TPS20
                                                  -                              +                     +
                                                                                                           24VDC
                                                                                                       -
                                                                                 -
                                                                                     DC4-20mA
                                                                                     Power 24VDC load 600Ω
                                                                                     Output DC4-20mA 2-wire
        Specifications
      Series                             TPS20
      Pressure type                      Gauge pressure                        Absolute pressure                   Compound pressure
      Rated pressure range               0 to 0.2 to 350kgf/cm2                0 to 1.0 to 35kgf/cm2               -760mmHg to 0 to 30kgf/cm2
      Max. pressure range                300% of max. span
      Measured materials                 Liquid, gas, oil (except corrosive environment of stainless steel type 316)
      Power supply                       15-35VDCᜡ
      Permissible voltage range          90 to 110% of rated voltage
      Current consumption                Max. 50mA
      Response time                      Max. 100ms
      Protection circuit                 Reverse polarity protection circuit
      Current output                     DC4-20mA
      Linearity                          ±0.3% F.S. (-10 to 50℃), ±0.5%F.S. (50 to 70℃)
      Hysteresis                         ±0.3% F.S.
      Temp. Zero Shift                   ±0.03% F.S.
      Temp. Span Shift                   ±0.03% F.S. (at 25℃)
      Load resistance                    Max. 600Ω
      Insulation resistance              Over 100MΩ (at 500VDC megger)
      Dielectric strength                500VAC 50/60Hz for 1 minute
      Vibration                          1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours
      Shock                              95m/s2
      Tightening torque                  Industrial plug over 5N
      Pressure port                      G3/8t (standard), R3/8, R1/2
                      Ambient temp.      -10 to 70℃, storage: -10 to 70℃
      Environment
                      Ambient humi.      5 to 95% RH, storage: 5 to 95% RH
      Materials                          Sealing, diaphragm, connection: stainless steel type 316, O-ring: fluoro rubber
      Connection                         +, -
      Case structure                     Drip-proof structure
      Approval                           ᜢ
      Weight※1                           Approx. 350g (approx. 320g) (based on head type)
      ※	1: The weight includes packaging. The weight in parenthesis is for unit only.
      ※	F.S.(Full Scale): It is rated pressure range.
      ※	Environment resistance is rated at no freezing or condensation.
F-9
                                                                                    Pressure Transmitter
 Troubleshooting                                                                                                                           A. Recorders
Error                                       Troubleshooting
                                                                                                                                           B. Indicators
                                            Check the power supply.
No outputs                                  Check the polarity (+, -) when wiring cable.
                                            Check the connection part.                                                                     C. Converters
                                            Check the power supply.
Abnormally fluctuating output               Check the supplied pressure.                                                                   D. Controllers
                                            Check the pressure line.
                                            Check the power supply.                                                                        E. Thyristor
                                            Check the load resistive value of current output type for a receiver is over 600Ω.                Power
Out of zero point output value                                                                                                                Controllers
                                            Check the measuring point and transmission distance.
                                            Check the line resistance is below 600Ω.                                                       F. Pressure
                                                                                                                                              Transmitters
                                                                                                                                           G. Temperature
                                                                                                                                              Transmitters
 Proper Usage
                                                                                                                                           H. Accessories
     •• When installing the unit on pipe line, use t he hexagon              •• The connection of this unit should be separated from
        part of connections not to turn the unit with a pipe                    the power line and high voltage line in order to prevent
        wrench. Do not use the unit with strong vibrations.                     inductive noise.
     •• This unit is manufactured with precisely. If you drop or             •• Install a power switch or a circuit breaker to supply or
        shock the unit, it may lose the function. Please treat the              cut off the power.
        unit carefully.                                                      •• Connect the power with the crimp terminals.
     •• Store the unit at the place without moisture, dust, and              •• Switch or circuit breaker should be installed nearby
        vibration.                                                              users for convenient control.
     •• This product which does not have drive part at sensing               •• Do not use the unit near the high frequency instruments
        part does not need to repair it. Even though inside                     (high frequency welding machine & sewing machine,
        of pressure pipe is normally clean, it needs to take                    large capacity SCR controller).
        maintenance once a year as below instructions.
                                                                             •• The unit cannot be repaired due to disassembled
     	 ① Check the broken status of outside.                                    structure.
     	 ② Check the pressure slot, cleanliness inside, and                    •• The unit is fixed with bolt and nut at the both sides of   TPS30
         corrosion state.                                                       case. Do not press excessive load (approx. 300kg/cm2),
        ③ Short each terminal and check the insulation                          or it may cause damage to the unit.
          resistance between the case and power.                             •• Do not pull the cables with over 30N of tension force.     TPS20
          (at 100VDC, over 10MΩ)
                                                                             •• Tighten the cable connection part firmly not to enter
        ④ Check zero, span adjustment and linearity by                          water to the cable.                                        KT-302H
          pressure standards.
                                                                             •• This product may be used in the following environments.
     •• When removing a sensor for maintenance, follow the
        below instructions.                                                  	   ① Indoor / Outdoor                                        PTF30
                                                                             	   ② Altitude max. 2,000m
     	 ① Replace an O-ring which is used once.                               	   ③ Pollution degree 2
     	 ② Be sure that diaphragm part is not damaged.                         	   ④ Installation category II
     •• In case of head type for connecting the power, use a
        crimp terminal. (M3.5, max. 7.2mm)                                   ※We are not responsible for any damages and claims
                                                                              for careless. Must read the proper usage.
                                                                                                                                                 F-10