INFORMATION TROUBLE REPORT
REPORT DATE                                                15/10/2015                                      MACHINE S/N                  A40943
CUSTOMER NAME                                            Anglo American                                    MACHINE MODEL                : 830E-1AC
MACHINE LOCATION                                         Minas Rio Project                                 FLEET NO.                    : CA1021
TROUBLE DATE                                                4/10/2015                                      ENGINE MODEL                 : QSK60
REPAIR DATE                                                 9/10/2015                                      ENGINE S/N                   : 33198712
SMR TROUBLE                                                    135                                         DELIVERY DATE                28/09/2015
SMR PARTS                                                      135                                         APPLICANT                    Geraldo Prates
SMR MACHINE                                                    135
                                                                                                     SYMPTOM :
                                                                         830E-1AC CA1021 A40943 - LH Wheel Motor locking
                                                          FAILURE : Crack, Dent, Worn, Scratch, Short Circuit, Burn, Bend, Loose, Rusty, Pitting, Broken etc
                                                                Wheel motor locking due lack of speed signal. Intermittent failure.
                               HOW WAS THE FAULT NOTICED                                                                                        MAIN PART CAUSED PROBLEM
During normal operation truck stopped to load on the shovel and when tried to leave the load area the LH                                         1 x GE Harness 58E-06-00630
  Wheel Motor was locking not allowing truck moviment. Was necessary cut out the inverter 1 to move
                                                 truck.
                                  CAUSED OF THE FAILURE ANALYSIS :                   (Describe detail of failure, analysis the cause, operating condition & ATTACHED PHOTOGRAPHS or Drawing)
                                                                     Analysing datapack Event 143,
                                                                     Subcode 02 – Traction Motor 1 Speed
                                                                     Sensor 1 (SS1) No Frequency Input
                                                                     was possible to verify that lost LH
                                                                     speed signal momentarily.
                                                                    Summary list from wPTU. As can be
                                                                    observed, it was a intermittent failure.
                                                                    Truck works few shifts without failure.
                                                                    It cause the troubleshooting soo long.
                                                                    When technictians arrive on the truck,
                                                                    no more failures active. Just on Oct 08
                                                                    that was possible see the failure at the
  - Normally failure happen when truck stop to load,                moment.
 dump or waiting on the line, not allowing truck start
 the moviment. We didn´t receive any feedback from
 operation that truck lock WM during moviment.
 fAILURE indicated that we had a harness problem on
 the truck.
  - LH and RH speed sensor were tested and swapped
 to verify if failure change of side. After few hours of
 operation event 143 happen again.
  - Speed sensor cable in side the WM was tested and
 identified a red cable pressed, measuring ground on
 RH WM. We removed cable protection and identified
 the pressed area. We fixed with insulation tape. But
 problem still continue on the LH WM with code 143/2.
  - We inspected connector CND, on the TB29 and
 J15/P15. Any problem identified.
  - We swapped the WM speed signal on the aux box
 (714 and 77 wiring) and also on the rear axle box.
 After it, event 52 tach right rear. Then problem change
 from left to right side.
 With this evidences we concluded the GE speed signal
 wiring from aux box to rear axle is damage causing this
 intermittent.
 As we dont have this harness available to delivery the
 machine, we took 2 x shield cable locally to put truck
 back to operation until the harness be available.
                                                                                                                                                        To availd problems, we connected shield from both
                                                                                                                                                        cables, welded the connections from cable and pins
                                                                                                                                                        and use thermo plastic to insulation.
                                                                                                                                                        Were used two cable because speed sensor signal use
                                                                                                                                                        7 wiring (Positive, Ground, Shield, +V1, -V1, +V2, -V2)
                                      CORRECTION MADE :                                                                                              OTHERS INFORMATION
It will be replace when parts be available.
                                                                                                           TSI to support a claim. Attached tty file and GE download, VHMS, real time data from DSC and PLM.