fx-100 e Cata PDF
fx-100 e Cata PDF
119
FX-100 SERIES
■■General terms and conditions.............. F-3 ■■Selection guide.................................. P.3~
FIBER Related Information
SENSORS ■■Fiber selection.................................... P.5~ ■■ Glossary of terms / General precautions........ P.1549~ / P.1552
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC Listing
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS PNP output Timer Interference Light intensity
type available prevention monitor
WIRE-SAVING
SYSTEMS * The FX-100 series has been changed to
Panasonic brand from production in and
MEASUREMENT
SENSORS
after July 2011.
* Cover opened state is shown.
panasonic.net/id/pidsx/global Automatic Test input
sensitivity setting
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
Taking fiber sensors to the next level
HUMAN MACHINE
INTERFACES Good dual digital display
ENERGY
MANAGEMENT The threshold value and incident light intensity can
SOLUTIONS
be both confirmed at the same time, bringing good
FA COMPONENTS operability when making changes of each setting.
Threshold value Incident light intensity
MACHINE VISION
SYSTEMS
UV CURING Commercially-available connectors reduce lead time and spare part numbers
SYSTEMS
Compatible with commercially-available connectors, so that
processing costs and lead time required for processing after
purchase can be greatly reduced. The connection parts same
as the DP-100 series digital pressure sensors and the PM-65
Selection
Guide series micro photoelectric sensors can be commonly used. Commercially-available
connector
Fibers
Fiber Commercially-available crimping connectors are used, so that
Amplifiers
the processing costs for connection cables can be greatly
Other Products
reduced.
Conventional (cable type) Conventional lead time
FX-500
● Harness processing by outside order is needed after sensor preparation.
FX-550
Customer Sensor preparation Sensor installation
FX-100
Purchase and preqaration of sensor Harness
Harness processing by outside order processor Harness processing
FX-410 Sensor installation
Saving-space with a width of 9 mm 0.354 in Improved stability over long terms FIBER
SENSORS
Very slim body at only 9 mm 0.354 in. This is much Utilizes “Four-chemical emitting element” for light LASER
thinner than existing fiber sensors. This makes a very emission. The light emission is guaranteed to be stable SENSORS
large difference when using many units, even if the over long periods of time. PHOTOELECTRIC
difference of one unit is small. SENSORS
[Stable sensing comparison] MICRO
PHOTOELECTRIC
FX-100 SENSORS
Three-chemical
AREA
9 mm emitting element
SENSORS
Light-emitting
0.354 in SAFETY LIGHT
Incident light intensity CURTAINS /
amount
Long-term SAFETY COMPONENTS
Threshold value stability PRESSURE /
FLOW
Time SENSORS
INDUCTIVE
PROXIMITY
Simple operation due to clear configuration system SENSORS
PARTICULAR
Continued to use the configuration system of digital pressure sensor DP-100 series, which has received high USE SENSORS
popularity since its release. We have separated the settings into three levels: RUN mode, SET mode, and PRO SENSOR
mode, making operation simpler and easier. OPTIONS
UV CURING
Quick code input function RUN mode SYSTEMS
FIBER Teaching with ON/OFF keys SET mode Resolves variation in incident light intensity display
SENSORS
GETA function PRO mode
LASER Simply press the ON key when an object is present, and
SENSORS OFF when it is not, and teaching is completed. There is Even when performing the same sensing operation,
PHOTOELECTRIC
no need to consider difference between Light-ON and there may be variances in the digital values of the fiber
SENSORS Dark-ON.
amp. There is no problem with the sensor itself, but the
MICRO
PHOTOELECTRIC <Setting example> operator may find it troubling.
SENSORS
Thru-beam type / Retroreflective type Given value can be corrected with the GETA function, so
AREA the apparent variation can be eliminated and the creation
SENSORS
of operation manuals can proceed smoothly.
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
Variations in the amount of light received
PRESSURE /
FLOW Object present ON Object absent OFF
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
Reflective type
SENSOR
OPTIONS Unify at 500 using
SIMPLE the GETA function
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
Threshold value A
Upper display limit
Actual digit difference: C
4000 Light emitting ,
amount decreased A
B
Saturated digit ,
Incident light
Time difference: D B
intensity
FX-100 SERIES
Digital Fiber Sensor
122
Emission frequency setting mode SET mode Setting copy function to reduce man-hours FIBER
SENSORS
and human error PRO mode
Mutual interference is prevented for max. 3 units for LASER
standard type FX-101□ and max. 4 units in case of long By connecting a fiber sensor to the master fiber sensor, SENSORS
sensing range type FX-102□. the master sensor settings can be copied along with PHOTOELECTRIC
During setting of interference prevention, emitter and data communications. When the same settings are SENSORS
output indicator both flash, so it is convenient to confirm input to several units, trouble from setting errors can be MICRO
which fiber is in the setting process at a glance. Emitter prevented, also changes to the work order will be small
PHOTOELECTRIC
SENSORS
flashes even when an amplifier is not installed close when equipment design is changed. AREA
together. SENSORS
* When the emission frequency is changed, a response time is also <Wiring to copy settings> SAFETY LIGHT
changed. Color of lead wire of attached connector cable CURTAINS /
SAFETY COMPONENTS
Master side PRESSURE /
(Brown) +V
FLOW
(Black) Output SENSORS
+ 12 to 24 V DC INDUCTIVE
(White) External input – ±10 % PROXIMITY
SENSORS
(Blue) 0 V
PARTICULAR
Slave side (Brown) +V USE SENSORS
The emitter and output indicator flash
at the same frequency. (Black) Output SENSOR
OPTIONS
(White) External input
SIMPLE
External input setting mode PRO mode (Blue) 0 V WIRE-SAVING
UNITS
External input can be selected from emission halt, limit These settings can be copied WIRE-SAVING
SYSTEMS
teaching / full-auto teaching / 2-level teaching, ECO
or emission amount test. Threshold value set at each Threshold value, output operation, timer operation, timer
MEASUREMENT
teaching is also memorized. emission amount, shift, external input, threshold value- SENSORS
storing, ECO inverting digital display, and threshold value STATIC
* 2-level teaching, emission amount test and threshold value storing
setting are available in amplifiers manufactured after December 2007.
margin CONTROL
DEVICES
Color of lead wire of attached connector cable LASER
(Brown) +V
Without mounting bracket MARKERS
Turn ON
sensing range type Fiber
Amplifiers
Other Products
Alert function PRO mode Standard type and long sensing range type are available
which has various response time and sensing range.
When the amount light received approaches the The model best meet application needs can be selected. FX-500
threshold value, the display can be made to blink in Sensing range FX-550
order to alert the operator. Model No. Type (FT-43) Response time
FX-100
<When using at a shift amount of 20% and a threshold value of 1,000> FX-101 Standard type 350 mm 13.780 in Max. 250 μs
FX-410
The amount of light received ranges from about 900 to 1,100 FX-102 Long sensing range type 970 mm 38.189 in Max. 2.5 ms
when the digital indicator flashes.
1,100 approx.
Threshold value When there is no key operations in approximately 20
900 approx.
of 1,000 seconds, digital display turns off and power consumption
can be reduced to 600 mW or less (720 mW in normal
mode).
FIBER
SENSORS
ORDER GUIDE
LASER Amplifiers
SENSORS
Accessory
PHOTO- Emitting
ELECTRIC Type Appearance Model No. Output
SENSORS element • CN-14A-C2
MICRO Connector attached
PHOTO- NPN open-collector
ELECTRIC FX-101 (Note 2) transistor
cable 2 m 6.562 ft
SENSORS
* Only include cable set type
M8 plug-in
NPN open-collector
connector
AREA
SENSORS FX-101-Z (Note 3) transistor
type
SAFETY LIGHT
Standard type
PNP open-collector
connector
FLOW
SENSORS FX-101P-Z (Note 3) transistor
type
INDUCTIVE
PROXIMITY NPN open-collector
FX-101-CC2
Cable set
(Note 1)
SENSORS transistor
PARTICULAR
USE PNP open-collector
SENSORS FX-101P-CC2 collector transistor
Red LED • FC-FX-1 (Protection cover)
SENSOR NPN open-collector
OPTIONS FX-102 (Note 2) transistor * It have been attached from the
SIMPLE production at July, 2011.
M8 plug-in
NPN open-collector
connector
Long sensing range type
WIRE-SAVING
UNITS FX-102-Z (Note 3) transistor
type
PNP open-collector
connector
MENT
SENSORS FX-102P-Z (Note 3) transistor
type
STATIC
CONTROL NPN open-collector
FX-102-CC2
Cable set
(Note 1)
DEVICES transistor
LASER PNP open-collector
MARKERS FX-102P-CC2 transistor
PLC Notes: 1) The connector attached cable 2 m 6.562 ft CN-14A-C2 is supplied with the amplifier.
2) Make sure to use the optional connector attached cable CN-14A(-R)-C□ or the connector CN-14A, or a connector manufactured by J.S.T. Mfg. Co., Ltd.
HUMAN (contact: SPHD-001T-P0.5, housing: PAP-04V-S)
MACHINE 3) Make sure to use the optional M8 connector attached cable CN-24A-C□.
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS OPTIONS
FA
COMPONENTS M8 connector attached cable
MACHINE Designation Model No. Description • CN-24A-C□
VISION
SYSTEMS 31.4 ø4
CN-14A-C1 1 m 3.281 ft 1.236 ø0.157
UV
CURING
SYSTEMS
Connector CN-14A-C2 (Note) 2 m 6.562 ft
attached cable CN-14A-C3 3 m 9.843 ft ø9 M8 connector
ø0.354 attached cable
CN-14A-C5 5 m 16.404 ft 0.2 mm2 4-core cabtyre cable with connector CN-24A-C□
on one end
CN-14A-R-C1 1 m 3.281 ft Cable outer diameter: ø3.7 mm ø0.146 in
Selection
Guide Connector CN-14A-R-C2 2 m 6.562 ft
attached cable Fixing ring
(Bending-resistant type) CN-14A-R-C3
Fibers 3 m 9.843 ft
Fiber
Amplifiers CN-14A-R-C5 5 m 16.404 ft
Other For M8 plug-in connector type
Amplifier mounting
M8 connector CN-24A-C2 2 m 6.562 ft
Products
The connector on one end bracket
attached cable CN-24A-C5 5 m 16.404 ft Cable outer diameter: ø4 mm ø0.157 in • MS-DIN-4
FX-500 Connector CN-14A Set of 10 housings and 40 contacts
Amplifier
FX-550
mounting bracket
MS-DIN-4 Mounting bracket for amplifier
FX-100
MS-DIN-E When an amplifier moves depending on the way it is installed
FX-410 End plates on a DIN rail, these end plates clamp amplifiers into place on
2 pcs. per set both sides.
Note: The connector attached cable CN-14A-C2 is supplied with the cable set type FX-10□-CC2.
Connector
attached cable
Recommended connector
• CN-14A(-R)-C□
Contact: SPHD-001T-P0.5, Housing: PAP-04V-S (Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details of the recommended products.
Connector
Recommended crimping tool • CN-14A
Model No.: YC-610R (Manufactured by J.S.T. Mfg. Co., Ltd.) Contact
Note: Contact the manufacturer for details of the recommended products.
Housing
FX-100 SERIES
Digital Fiber Sensor
124
SPECIFICATIONS FIBER
SENSORS
LASER
Standard type Long sensing range type SENSORS
Type
PHOTO-
Cable set Cable set ELECTRIC
SENSORS
Model No.
PARTICULAR
Output operation Selectable either Light-ON or Dark-ON, at SET mode USE
SENSORS
Short-circuit protection Incorporated
SENSOR
<NPN output type> <PNP output type> OPTIONS
NPN non-contact input PNP non-contact input
• Signal condition • Signal condition SIMPLE
WIRE-SAVING
External input High: +8 V to +V DC or Open High: +4 V to +V DC UNITS
Low: 0 to +2 V DC (Sink current 0.5 to 3 mA)
(Source current 0.5 mA or less) Low: 0 to +0.6 V DC or Open WIRE-SAVING
SYSTEMS
• Input impedance: 10 kΩ approx. • Input impedance: 10 kΩ approx.
MEASURE-
Emission frequency 0: 250 µs or less (factory default setting) Emission frequency 1: 2.5 ms or less (factory default setting) MENT
Emission frequency 1: 450 µs or less Emission frequency 2: 2.8 ms or less SENSORS
Response time
Emission frequency 2: 500 µs or less Emission frequency 3: 3.2 ms or less STATIC
Emission frequency 3: 600 µs or less Emission frequency 4: 5.0 ms or less CONTROL
DEVICES
Sensitivity setting 2-point teaching / Limit teaching / Full-auto teaching
LASER
Operation indicator Orange LED (lights up when the output is ON) MARKERS
Material Enclosure: Polycarbonate, Key switch: Polycarbonate, Fiber lock lever: PBT Fibers
Fiber
Connecting method Connector (Note 4) Amplifiers
Cable length Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. Other
Products
Net weight: 15 g approx. Net weight: 15 g approx. Net weight: 15 g approx. Net weight: 15 g approx.
Weight
Gross weight: 35 g approx. Gross weight: 75 g approx. Gross weight: 35 g approx. Gross weight: 75 g approx.
FC-FX-1 FC-FX-1 FX-500
FC-FX-1 (Protection cover): 1 pc. (Note 6) FC-FX-1 (Protection cover): 1 pc. (Note 6) FX-550
Accessory
(Protection cover): 1 pc. (Note 6) CN-14A-C2 (Protection cover): 1 pc. (Note 6) CN-14A-C2
(Connector attached cable, 2 m 6.562 ft long): 1 pc. (Connector attached cable, 2 m 6.562 ft long): 1 pc. FX-100
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. FX-410
2) When using the interference prevention function, set the emission frequencies for the amplifiers to be covered by the interference prevention function to
different frequency values.
However, the interference prevention function does not operate at emission frequency 0 (factory default setting) for the FX-101(P)(-Z) / FX-101(P)-CC2.
3) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.
4) Connector attached cable CN-14A-C2 is not attached to the models that have no “-CC2” at the end of the model Nos.
Make sure to use the optional connector attached cable CN-14A(-R)-C□ or the connector CN-14A, or a connector manufactured by J.S.T. Mfg., Ltd.
(contact: SPHD-001T-P0.5, housing: PAP-04V-S).
5) Model Nos. having the suffix “-Z” are M8 plug-in connector type. Make sure to use the optional M8 attached connector cable CN-24A-C□.
6) Protection cover FC-FX-1 has been attached from production in July, 2011.
LIST OF FIBERS
FIBER
SENSORS
I/O CIRCUIT AND WIRING DIAGRAMS
LASER
SENSORS FX-10□(-Z/-CC2) NPN output type
PHOTO-
ELECTRIC I/O circuit diagram Terminal arrangement diagram
SENSORS
MICRO Terminal No.
PHOTO- Connector type
ELECTRIC
SENSORS Color code of cable with connector
AREA
SENSORS (Brown) +V Terminal No. Function
1
D
SAFETY LIGHT
(Black) Output
Load 1 +V
CURTAINS /
Sensor circuit
SAFETY Tr 2
COMPONENTS
+8 V 100 mA max. + 12 to 24 V DC 2 Output
ZD
PRESSURE /
(White) External input - ±10 % 3
FLOW 3 External input
SENSORS *1 4
INDUCTIVE (Blue) 0 V 0V
PROXIMITY 4
SENSORS
Internal circuit Users’ circuit
PARTICULAR
USE
SENSORS M8 plug-in connector type
Symbols … D : Reverse supply polarity protection diode
SENSOR
OPTIONS ZD: Surge absorption zener diode
Tr : NPN output transistor Terminal No. Function
SIMPLE
WIRE-SAVING +V
UNITS * 1 1
2
WIRE-SAVING Output
SYSTEMS Non-voltage contact or NPN open-collector transistor
External input
4
MEASURE-
MENT
or 3
SENSORS
0V
LASER
MARKERS
FX-10□P(-Z/-CC2) PNP output type
PLC
I/O circuit diagram Terminal arrangement diagram
HUMAN
MACHINE Terminal No.
INTERFACES Connector type
ENERGY Color code of cable with connector
MANAGEMENT
SOLUTIONS
(Brown) +V Terminal No. Function
1
FA *1
COMPONENTS
(White) External input 1 +V
Sensor circuit
3
MACHINE + 12 to 24 V DC 2 Output
VISION ZD
SYSTEMS 100 mA max. - ±10 % 3
Tr 2 External input
UV (Black) Output 4
CURING Load
SYSTEMS
D (Blue) 0 V 0V
4
FX-550
High [ +4 V to +V DC (sink current 0.5 to 3 mA)]: Effective
FX-100 Low (0 to +0.6 V DC, or open): Ineffective
FX-410
FX-100 SERIES
Digital Fiber Sensor
126
SENSING CHARACTERISTICS (TYPICAL) Contact our office for sensing characteristics that are not contained here. FIBER
SENSORS
LASER
FT-31S Thru-beam type FT-31W Thru-beam type FT-42S Thru-beam type FT-42W Thru-beam type SENSORS
PHOTO-
Parallel deviation Parallel deviation Parallel deviation Parallel deviation ELECTRIC
SENSORS
400 250 1,000 800 MICRO
15.748 9.843 39.370 31.496 PHOTO-
ELECTRIC
SENSORS
FX-102 200 FX-102 800 FX-102
300 7.874
600
SENSORS
FTA233
Parallel deviation Parallel deviation Sensing field Sensing field MACHINE
VISION
250 800 250 250 SYSTEMS
31.496 ℓ White non-glossy paper 200mm 7.874in
9.843 9.843 White non-glossy paper 9.843
L 200mm 7.874in ℓ UV
FX-102 FX-102 L CURING
200 200 Fiber 200 SYSTEMS
Setting distance L (mm in)
600 head
Setting distance L (mm in)
Fiber
Setting distance L (mm in)
FX-500
200 200
Setting distance L (mm in)
Setting distance L (mm in)
FDA269 FDA266
FX-100 SERIES
127 Digital Fiber Sensor
FIBER
SENSORS
SENSING CHARACTERISTICS (TYPICAL) Contact our office for sensing characteristics that are not contained here.
LASER
SENSORS FD-42G Reflective type FD-42GW Reflective type FD-61G Reflective type
PHOTO-
ELECTRIC Sensing field Sensing field Sensing field
SENSORS
MICRO 250 150 400
PHOTO- 9.843 5.906 15.748
ELECTRIC
SENSORS
200 FX-102
Setting distance L (mm in)
7.874 7.874
Setting distance L (mm in)
7.874 7.874
Setting distance L (mm in)
Fiber
White head
FX-102 FX-102
150 FX-102 150 FX-102 150 non-glossy 150 Up
5.906 White non-glossy 5.906 White non-glossy 5.906 paper 5.906 Down
paper paper 200mm
FX-101 200mm 7.874in FX-101 200mm 7.874in FX-101 7.874in FX-101
Selection 100 100 100 100
Guide ℓ ℓ ℓ
3.937 3.937 3.937 3.937
Fibers L L L
50 Fiber 50 Fiber 50 Fiber 50
Fiber 1.969 head 1.969 head 1.969 head 1.969
Amplifiers Up
Other Left Right Down Left Right
0 0 0 0
Products 60 40 20 0 20 40 60 60 40 20 0 20 40 60 60 40 20 0 20 40 60 60 40 20 0 20 40 60
2.362 1.575 0.787 0.787 1.575 2.362 2.362 1.575 0.787 0.787 1.575 2.362 2.362 1.575 0.787 0.787 1.575 2.362 2.362 1.575 0.787 0.787 1.575 2.362
Left Center Right Left Center Right Left Center Right Down Center Up
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
FX-500
FX-550
FD-S33GW Reflective type
FDA276 FDA276 FDA267 FDA267
FX-100
Sensing field
FX-410
150
5.906
Setting distance L (mm in)
100 FX-102
3.937
White non-glossy
paper
FX-101 200mm 7.874in
ℓ
50
1.969 L
Fiber
head
Left Right
0
30 20 10 0 10 20 30
1.181 0.787 0.394 0.394 0.787 1.181
Left Center Right
Operating point ℓ (mm in)
FDA275
FX-100 SERIES
Digital Fiber Sensor
128
Refer to p.1552 ~ for general precautions.
Refer to General precautions, and to the “Operation Guide” on our
PRECAUTIONS FOR PROPER USE website for details pertaining to operating instructions for the amplifier. FIBER
SENSORS
LASER
Wiring SENSORS
• Never use this product as a sensing device
for personnel protection. • Make sure that the power supply is OFF while adding or
PHOTO-
ELECTRIC
SENSORS
• In case of using sensing devices for removing the amplifiers. MICRO
personnel protection, use products which • Note that if a voltage exceeding the reted range is applied,
PHOTO-
ELECTRIC
meet laws and standards, such as OSHA, SENSORS
or if an AC power supply is directly connected, the product
ANSI or IEC etc., for personnel protection AREA
applicable in each region or country. may get burnt or damaged. SENSORS
• Note that short-circuit of the load or wrong wiring may burn SAFETY LIGHT
CURTAINS /
or damage the product. SAFETY
COMPONENTS
Using in combination with the FX-300 / FX-410 series • Do not run the wires together with high-voltage lines or PRESSURE /
FLOW
• The FX-100 series does not use the horizontal power lines, or put them in the same raceway. This can SENSORS
connectors that are used with the FX-300 / FX-410 cause malfunction due to induction. INDUCTIVE
PROXIMITY
series. Please note that horizontal connection cannot be • Verify that the supply voltage variation is within the rating.
SENSORS
performed using a connector attached cable. In addition, • If power is supplied from a commercial switching regulator,
PARTICULAR
USE
SENSORS
the optical communication function is not equipped on ensure that the frame ground (F.G.) terminal of the power
the FX-100 series, so it is unable to perform interference supply is connected to an actual ground. SENSOR
OPTIONS
prevention for use with the FX-300 / FX-410 series.
• In case noise generating equipment (switching regulator, SIMPLE
If using the FX-100 series together with the FX-300 / WIRE-SAVING
inverter motor, etc.) is used in the vicinity of this product, UNITS
FX-410 series side-by-side, please set the same models
connect the frame ground (F.G.) terminal of the equipment
together in groups. WIRE-SAVING
to an actual ground. SYSTEMS
Mounting • Make sure to use the quick-connection cable (optional) for MEASURE-
MENT
the connection of the controller. SENSORS
<When using a DIN rail>
Extension up to total 100 m 328.084 ft is possible with 0.3 STATIC
CONTROL
How to mount the amplifier mm2 or more, cable. However, in order to reduce noise, DEVICES
2 Press down the rear part of the ON key / OFF key / HUMAN
mounting section of the unit on the 2
Operation indicator
Setting value UP key Setting value DOWN key MACHINE
INTERFACES
1
35 mm 1.378 in width DIN rail and (Orange) MODE key
ENERGY
fit the front part of the mounting 35 mm 1.378 in width DIN rail MANAGEMENT
SOLUTIONS
section to the DIN rail.
FA
How to remove the amplifier Digital display (Green) Digital display (Red) COMPONENTS
(Threshold value) (Incident light intensity)
MACHINE
1 Push the amplifier forward. 2
1 VISION
SYSTEMS
2 Lift up the front part of the Setting mode UV
amplifier to remove it. • Setting mode appears after the MODE key is pressed for
CURING
SYSTEMS
2 sec. in RUN mode.
Note: Take care that if the front part is lifted without pushing the amplifier
forward, the hook on the rear portion of the mounting section is likely Setting item Factory setting Description
to break.
Teaching Threshold value can be set in 2-point teaching, Selection
mode limit teaching, or full-auto teaching. Guide
<When using screws with washers>
Fibers
• Use M3 screws with washers Output Fiber
Amplifiers
for mounting. The tightening operation Light-ON or Dark-ON can be set.
[Dark-ON] Other
torque should be 0.5 N·m or setting Products
less.
Timer
Without timer, ON delay timer, or OFF delay FX-500
operation
[Without timer] timer can be set.
setting FX-550
Emission
In case incident light intensity is saturated,
amount
* [Level 3] emission amount can be reduced.
setting
FX-101□
When using the fiber heads in parallel,
0 (Response time: interference can be prevented by setting
Emission 250 µs or less) different emission frequency. However, when
frequency FX-102□ emission frequency 0 is set, interference
setting
cannot be prevented. Response time
1 (Response time: corresponds to emission frequency.
2.5 ms or less)
to fluorescent lamp from a rapid-starter lamp, a high the ON key ( ) and OFF key ( ) simultaneously for 4 AREA
SENSORS
frequency lighting device or sunlight etc., as it may affect seconds will switch to the code setting function.
SAFETY LIGHT
the sensing performance. CURTAINS /
SAFETY
• This product is suitable for indoor use only. <Code table> COMPONENTS
Code
frequency
• Never disassemble or modify this product. Output Timer amount
ECO
External Shift SENSOR
OPTIONS
• EEPROM is adopted to this product. It is not possible to operation (Note 1) setting input (Note 1)
(Note 2) FX-101□ FX-102□
conduct teaching 100 thousand times or more, because SIMPLE
WIRE-SAVING
of the EEPROM’s lifetime. UNITS
Emission
non 0 1 5% WIRE-SAVING
halt
Quick setting function SYSTEMS
• While in the RUN Mode, pressing and holding both teaching [-]
LASER
the ON key ( ) and OFF key ( ) simultaneously for 2 MARKERS
LASER
SENSORS FX-101□ FX-102□ Amplifier FX-101(P)-Z FX-102(P)-Z Amplifier
PHOTO-
ELECTRIC 10.85
SENSORS 6 0.236 6 0.236 10.85
6 0.236 6 0.236 0.427
48 1.890 48 1.890 6 0.236 6 0.236 0.427
MICRO 48 1.890
30 1.181
30 1.181 0.8
PHOTO- 0.8 13.2 20 2.7 0.7 30 1.181 20
13.2 2.7
ELECTRIC 0.031 0.787 0.106 0.028 0.8
0.031 13.2
0.520 20
0.787 2.7
0.106
SENSORS 0.520
0.031 0.520 0.787 0.106
0.7 0.028
AREA 0.7 0.028
SENSORS 4.1 OFF key / Setting value DOWN key 4.1 OFF key / Setting value DOWN key
4.1
Operation indicator (Orange) 0.161 OFF key / Setting value DOWN key
SAFETY LIGHT Operation indicator (Orange) 0.161 ON key / Setting value UP key Operation indicator (Orange) 0.161
ON key / Setting value UP key
ON key / Setting value UP key
CURTAINS / Digital display (Green, Red) MODE key Digital display (Green, Red) MODE key
SAFETY Digital display (Green, Red) MODE key
COMPONENTS
PRESSURE /
FLOW
SENSORS
0.75 0.030
INDUCTIVE 0.75 0.030 0.75 0.030
PROXIMITY
SENSORS
PARTICULAR 66.2 1
USE 9 66.2
2.606 1
SENSORS 66.2 9
0.354 0.039
9 2.606 2 0.079 2.606 0.039
0.354 0.354
6 0.236
SENSOR 6 0.2361.1 ø6.5
OPTIONS 6 0.236 ø6.5
ø0.256
1.1
0.043 0.8 ø0.256
1.1 2 0.043 0.8
0.031 10 30
0.043 0.8 0.079 7
0.031 30
SIMPLE 0.031
0.276
7 4 0.157 3 0.118 10 1.181
0.394
WIRE-SAVING 7 10 30 0.276 4 0.157 3 0.118 0.3941.181
UNITS 0.276 4 0.157 0.394 1.181 10
3 0.118 10
0.394
10 8.1 0.394 ø3.2
WIRE-SAVING 0.394 0.319 ø3.2
ø0.126 3.2 8.1
SYSTEMS ø3.2 6.5 ø0.126 2 3.2
0.126 8.1
ø0.126 3.2 6.5
0.256 50 1.969 2
0.079 0.126 0.319
0.319
50
351.969
MEASURE- 6.5 50 1.969 2 0.126 0.256 14.5 1.378 0.079
0.256 0.079 14.5
0.571 35 1.378
MENT 0.571 65.5 2.579
SENSORS 14.5 35 1.378 65.5 2.579
0.571 Suitable for 35 mm 1.378 in width DIN rail
65.5 2.579 Suitable for 35 mm 1.378 in width DIN rail
STATIC Suitable for 35 mm 1.378 in width DIN rail
CONTROL
DEVICES
Note: The protection cover has been attached from the production at July, 2011. Note: The protection cover has been attached from the production at July, 2011.
LASER
MARKERS
PLC MS-DIN-4 Amplifier mounting bracket (Optional) MS-DIN-E End plate (Optional)
4 1
0.157 0.039 Material: Polycarbonate
5 24.5
0.197 0.965
35
Selection 1.378
Guide Material: PBT
Fibers
Fiber
Amplifiers CN-14A-C□ CN-14A-R-C□ Connector attached cable (Optional)
Other
Products
CN-14A-C2 is attached to FX-101(P)-CC2 / FX-102(P)-CC2
L
( 35
1.378 ) (50
)
1.969
• Length L
FX-500 (0.3158 ) (0.3158 ) Model No. Length L
FX-550 CN-14A(-R)-C1 1,000 39.370
FX-100 ø3.7 ø0.146 cable CN-14A(-R)-C2 2,000 78.740
MEMO