0% found this document useful (0 votes)
411 views8 pages

Pro Ex User Manual

Pro ex user manual

Uploaded by

JAYKUMAR SINGH
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
411 views8 pages

Pro Ex User Manual

Pro ex user manual

Uploaded by

JAYKUMAR SINGH
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 8
PRO EX Digital Panel Meter User manual « PRO EXI31 AC Current digital panel meter PRO EXU31 AC Voltage digital panel meter PRO EXDU3I DC Voltage digital panel meter PRO EXDI31 DC Current digital panel meter PRO EXL31 Power Factor digital panel meter PRO EXTS1 temperature digital panel meter oo + ne ARTEL iii 71 W049 BAR AD Shenzhen Artel Tech.Co.,.Ltd, PROEX digital pane! meter PROEX 131 Wiring Diagram 3.2 PROEX U31 AC Voltage digital panel meter Input: 100V, 120V, 220V, 380¥, 500¥, GOOVAC PT scope: 1~6000 Alarm limit setup: Upper Limit (<1 X full scale), Lower limit (¢ upper limit value), Pall back value setup (<255) PROEX USI Wiring Diagram 3.3 PROEX DUS DC Voltage digital panel meter Input: 100V, 150V, 220V, 500¥, 600¥DC; Marn Linit setup: Upper limit (<1 X full scale), Lower Limit (< upper limit value) , Fall back value setup (<255) PROEX DU31 Wiring Diagram 3.4 PROEX DI31 DC Current digital panel meter Inputs 75n¥s CT scope: 1~6000; Alarm limit setup: Upper limit (<1 X full scale), Lover limit (< upper limit value) , Fal? ‘SZARTEL 2 PROEX digital ponel meter a Il. Profile PRO EX digital panel meter is an intelligent instrument thet has integrated with modular design of digital display, analog output, RS 485 overlimit alarm record and relay output. The instrument fulfills GB/T13978-1992, GBM 13850-1998 standard, GBIT 17620.X-1999, IECIO10 and EN61010 standard. IL. Technical standard Accuracy Class: Class 0.2, Class 0.5, Class 1.0, Display resolution: :+2Digit ‘Auniliary Power Supply: 24V-80V AC/DC 85V-265V AC/DC Power Consumption: <3VA Long term stability: annual change<:t0. 2% Tonperature drifting factor: 100ppm Input Overcapacity: Continuously overload capacity> X 1.5 (overload X 1.2) ‘Transient overload capacity Voltage > X 3, Current > X50 Analog Output: Constant Voltage output, Rext 22509 (0-SV output) Constant Current output, Rext 27500 (4-20mAoutput) Rext=eollf, Voltage Limit<20V Alternating wave <16,V (peak-peak) Response time <300n5 (<100n5) Output: 4-20mA 0-20nA 0-10mA O-ImA O-1V 0-5V 0-10V) Digital output: RS—485 com, Modbus protocol Relay output: capacity of contact: 54/250VAC, 104/24VDC Meterial of terminal: PPO, flaemability accords to UL94VO Anti-Voltage capability: 225007 Insulated resistor: > 100M 2 Operation temperature:-10°C~55°C Operation Humidi ty:<95% (non-condensing) Storage temperature:-40'C~80°C Storage humidity: <05% Dimensional Size:48X96X 76am? Installation: Panel mounting Installation size: 46X94 mn? Ill. Each Type of digital panel meter 3. L PROEX I31 AC Current digital panel meter Connection: single phase, Input: 1A, 28, 5A, CT scope: 1~6000, Alarm Limit setup: upper value setup (<1.5X full scale), Lover limit (< upper limit value), Wiring diagram: Ef ‘SZARTEL ' PROEX 131 Wiring Diagram 3,2 PROEX U31 AC Voltage digital panel meter Input: 1OOV, 120V, 220V, S80V, 500V, 6OOYAC PT scope: 1~6000 Alarm limit setup: Upper limit (<1 X full scale), Lower Limit (< upper limit value) , Fall back value setup (<255) PROEX USI Wiring Diagram 3.3 PROEX DU31 DC Voltage digital panel meter Input: 100V, 150V, 220V, S00V, 600¥DC. ‘Alara limit setup: Upper limit (<1X full scale), Lower limit (< upper Limit value) , Fall back value setup (<255) PROEX DUSI Wiring Diagram 3.4 PROEX DI31 DC Current digital panel meter Input: 750V: €T scope: 1~600 Alarm Limit setup: Upper limit (<1¥X full scale), Lower Limit (< upper Limit value) , Pall ‘SZARTEL 2 PROEX digital panel meter back value setup (<255) . PROEX D131 Wiring Diagram 3.5 PROEX L31 Power Factor digital panel meter Input Voltage: 24V~100VAC , 150V~600VAC Frequency: 45~~50~S5IZ, 48~50~S21I2, 49~60~51HZ, 55~60~65H2, 58~60~62HZ, 59~60~61HZ, 360~400~440H2, 392~400~408HZ Alarm limit setup: Upper Limit (<1 full scale), Lower limit (< upper Linit value) , Fallback value setup (<255) PROEX 131(ingle phase) Witing Diagram 3.6 PROEX T31 Temperature Input: PTSO, PT100, CUS0, CU100 4 Alarm limit setup: Upper limit (<1X full scale), Lower Limit (< upper limit value) , Fallback value setup (<255) oo PROEX 131 Wiring Diagram SZARTEL 3 RRO gia panel meter IV. Panel Operation and installation 4.1. Panel is consisted of 3 parts: Display LED, indicator and button 1 —4 Button description: ZTl-s 3 6 1 Display window [ro one] 2. Overlimit indicator roa DO Ol D 3 Undetinit intr GOGO 4 XIK unit indicator Meter front graph 5. Xtunit indicator 6 Run indicator 4.2,Button description: 42.1 ()—n the parameter modification mode, the cursor moves tothe right 422 (&)—rn the parameter modification mode, the digit adds 1 423 @—rn the setup mode, when the main menu appears, the meter scrolls to the next submenu by pressing it In the parameter modification mode, the meter quits the current setup without saving parameter and return to the main menu by pressing it 42:4 @—— In the semp mode, when the main mena appears, the metar ener 10 the parameter modification page When in the parameter modification mode, the meter saves the current modification and switch to the submenn, 425 Q+©_ — Press and hold both keys for 3 seconds, the mete enters to setup state 426 (b)+ G —Switch between X tand X 1K unit indicator. 42.7 (B) + @ —when in the parameter modification mode, the cursor moves to right positon 42.8 When holding and pressing @) + Gover 3 seconds, [ETO OO] appears, the user is required to input password (the initial password is| || ) , then pressing ({)) to confirm the ccurregt input and centers the setup mode. SZARTEL ‘4 ‘Table 1-1: Menu parameter description PRO EX digital pone] meter ® | Add [| com Aattes setup Scope 1-255 BT Alu) | combusesene 19200,9600,4800,2400,1200 ©} PE PT setup ‘Scope 1~6000 > ICE CT semp Scope 1~6000 © | HI GH | Atm Upper value setup F}tgu ‘Alarm Lower Value setup S| AH [Alam tock vatue «(AE [aden ® eae for 0 and full scale J | SEP qq | oscate calibration O scale calibration K LE UL L | Fatscate catibration Fall seale calibration PSL Ee [esse nose ™ | PI Parameter modification setup | Bater parameter modification setup 43,Example: PRO EX I3ldigitel panel meter with RS-48Soutput, the meter address as 5, baud rate as 9600bps, CT ratio 2000/1, password is to be changed to 1234. The detailed setup operation is as the following: 4.3.1,Press and hold (@} Q):ry for3 seconds, the [17 OH Li] page displays, the cursor shimmers at the upper left digit, press (AQ) key to set the Ist digit tq, and press(p) ‘ey to move to the 2nd digit, like wise, so that the 4 digit are all setas | , press (©) key to confirm the setup mode, 4, 3.2,When item A shown as in the table 1-1 shows, press(p) key or (&) key to wodify the meter adiress tof] O15 » press @ key to confirm the current setup and the meter goes to the itgy B 4.3.3,When item B baud rate appears, press (A)to choose the baud rate YBOQ and press © key to confirm 4.3.4,Press @) to display iten D, and press ()key to enter CT setup. Press (}) or @to modify CT to AO} (]. and press © key to confirm, 43.6,¥hen item L appears, press (pyr (@)ey to change the password to | @ 34 , and then press © “ Remark: please remeber your new password. Otherwise, please contact the manufacturer. y to confirm. 4.3.1, Press@) key to display all the itens from toble 1-1, After all the parameters are set up, 5 SZARTEL RO EX dtl pel mtr press ©to oxit the setup 4.4,.Meter Installation (1) Please install the meter in the hole of the panel, and install the fastening and supporting components on the side of meter. (2) Fasten the serew clockavise so thatthe meter isin the pane! Fasten Bolt Supporting compon. Meter Panel Sera teal = a | Shenzhen Arte! Technology Co., Ltd. Tel: +86 755 83424596 Fax: +86 755 83402232 Zip: $18040 ‘Add: 8D, F4.8Bldg., Tian An Cyber City, Shenzhen, China Hitp//www.szartel.com E-mail:contact@szartel.com et SZARTEL

You might also like