Service bulletin
To:                         Service technicians
From:                       Star Cool Service Team
Date:                       2007-03-05
Regarding:                  Upload of controller software using the LOGMAN.
How to upload new controller software to a Star Cool controller
- The right software in LOGMAN
- Transfer Star Cool controller software to the LOGMAN
- Upload new Star Cool controller software with the LOGMAN
This instruction requires LOGVIEW (preferably the newest version) and EPOC
CONNECT LITE to be installed in order to communicate with the LOGMAN unit.
The right software in the LOGMAN
In order to communicate with the Star Cool
controller, the LOGMAN needs LOGMAN 2.14
software or higher.
                                                                                   Required programs
To install new software in the LOGMAN:
If old LOGMAN software is still installed on the PC
it is suggested to remove/delete it first.
To remove old LOGMAN software from the PC:
Left click on start, go into settings -> control panel
Double click on add/remove program, highlight
LOGMAN and press OK. This should uninstall the
LOGMAN software.
Download the newest software, and run the
LOGMAN.exe file. The LOGMAN software will install
itself under C:\Program files\York\LOGMAN\Srca.
Before formatting and uploading software to the
LOGMAN, it is a good idea to replace the main
batteries in the LOGMAN. If the batteries are low
on power it can create difficulties when writing on                                LOGMAN
the disks.
________________________________________________________________________________________________________________________
              Bjerndrupvej 47 • 6360 Tinglev, Denmark • Phone: +45 7364 3400 • Fax: +45 7364 3569
                      CVR/SE no.: 13 82 37 74 • starcool@starcool.dk • www.maerskbox.com
  Service bulletin
Format of the A-disk can be done in two ways:
Format of top disk directly with the LOGMAN:
1. Open the LOGMAN and by pushing the release
button on the back side of the LOGMAN. Press left
bottom key - U, Ctrl and Del simultaneously.
(reeboots the LOGMAN). Insert Startup
(autoexec) will be displayed                                                     Pull out the top disk and reboot
2. Close the LOGMAN and press "Menu"
3. Scroll down to "System screen" and press
Enter
4. When the icon "Data" is now highlighted, press
"Menu"
5. Scroll right to "Disk" and scroll down to "Format
disk" and press Enter.
6. At Disk, select "A" (Top disk, which contains the                              Press Menu
LOGMAN software with the left or right arrow key
and press Enter
7. To format the A disk (top disk) press Y.
Format of top disk by use of LOGVIEW:
On the PC open the LOGVIEW program and
connect the LOGMAN to the PC with the transfer                                    Choose System screen
cable and select connect to PC on the LOGMAN by
pressing E and use up/down arrows to choose
PC 112K then press Enter.
In the LOGVIEW window, Select retrieve ->
Psion Link -> Format drive -> pc and press
execute. Select A (top disk) and press OK
This should format the A disk containing the
software.                                                                         Choose Data-> press Menu
                                                                                  Choose Disk->Format
                                                                                  Disk->A
  ________________________________________________________________________________________________________________________
                Bjerndrupvej 47 • 6360 Tinglev, Denmark • Phone: +45 7364 3400 • Fax: +45 7364 3569
                        CVR/SE no.: 13 82 37 74 • starcool@starcool.dk • www.maerskbox.com
  Service bulletin
Upload of new LOGMAN software:
1. Switch ON the LOGMAN
2. Open the LOGMAN by pushing the release
button on the back side of the LOGMAN.
3. Boot the LOGMAN by pushing bottom left key-
U, Ctrl and Del simultaneously.
                                                                                  Choose System screen
4. Make sure the two solid state discs are not
write protected
The display should now read Insert Startup
(autoexe) SSD and press Enter or press Menu for
System Interface. Close the LOGMAN again.
5. Push the Menu key
                                                                                  Choose Data-> press Menu
6. There are now 4 options shown in the display.
Choose System Screen by scrolling with the
arrow keys and press Enter.
7. You can now scroll with the left and right arrow
key. Choose Data and press the Menu key.
8. Scroll with the left or right arrow and place the
cursor on the Spec. Now use the down arrow
and choose Remote link and press Enter.                                       Choose Spec->Remote
                                                                                  link->Remote link
9. In Remote link set it to "ON" with the left or
right key.
10. Scroll down with the arrow key to Baud rate.
Choose the highest speed with the right key
(115200)
                                                                                  Settings to be made in
11. Scroll down with the arrow key to Port and                                  Remote Link -> Enter
choose "A" and press Enter. The screen will now
go back to the same screen as in number 7.
It is now ready to receive software.
                                                                                  SW can now be transferred
                                                                                  to LOGMAN from LOGVIEW
  ________________________________________________________________________________________________________________________
                Bjerndrupvej 47 • 6360 Tinglev, Denmark • Phone: +45 7364 3400 • Fax: +45 7364 3569
                        CVR/SE no.: 13 82 37 74 • starcool@starcool.dk • www.maerskbox.com
  Service bulletin
Transfer LOGMAN software to the LOGMAN:
1. Connect the LOGMAN to the PC with the
transfer cable.
2. On the PC, open the LOGVIEW program
                                                                                  Point Select Archive Path to
3. In the left side window choose C: under the
                                                                                  the right folder
Select Archive drive. Double click on the Folder
Program Files Double click on the Folder YORK
Double click on the Folder LOGMAN Double click
on the Folder Srca
You now have the correct path
4. In the toolbar click on Retrieve.
5. Click on the Psion Link.
6. A Psion Link window is now shown. Under the
command line, choose Copy SW -PC-> Under
Device, choose LOGMAN
7. To transfer the software click Execute
When No Files appear in the connect window                                      Choose Copy SW - PC-> in
beside the STATUS bar the transfer is complete.                                   Command and then press
Upon completion, reboot the LOGMAN.                                               Execute
Please note that the LOGMAN internal clock must
be updated with GMT time and date before
downloading logs. In the main menu of the
LOGMAN select D, LOGMAN functions then C
Set Logman time and insert correct date and
time (GMT time).
  ________________________________________________________________________________________________________________________
                Bjerndrupvej 47 • 6360 Tinglev, Denmark • Phone: +45 7364 3400 • Fax: +45 7364 3569
                        CVR/SE no.: 13 82 37 74 • starcool@starcool.dk • www.maerskbox.com
  Service bulletin
Transfer Star Cool controller software to the
LOGMAN
Download the newest version of Star Cool
controller software (RCCU0xxx.bin) from the Star
Cool website (www.starcool.dk). Save the .bin 
file to a known folder.
The software for the different reefer unit                                        Prepare LOGMAN for PC
controllers are stored on the M disk (permanent                                 connection
disk) of the LOGMAN.
1. Connect the LOGMAN to the PC with the
transfer cable.
2. Select connect to PC on the LOGMAN by
pressing E and use up/down arrows to choose
PC 112K then press Enter. The LOGMAN is now
ready to receive the controller software.                                         Select path to Star Cool
                                                                                  controller software
3. On the PC, open the LOGVIEW program
In the left side window choose the folder in where
you saved the new Star Cool controller software.
4. In the toolbar click on Retrieve.
5. Click on the Psion Link. A Psion Link window is
now shown.
6. Choose Copy CTRL SW -PC-> in command
and LOGMAN in Device
7. Click on Execute to transfer the software.
When the Execute button once again is
highlighted the transfer is complete.                                             Choose Copy CTRL SW -
                                                                                  PC-> in Command and
                                                                                  then press Execute
  ________________________________________________________________________________________________________________________
                Bjerndrupvej 47 • 6360 Tinglev, Denmark • Phone: +45 7364 3400 • Fax: +45 7364 3569
                        CVR/SE no.: 13 82 37 74 • starcool@starcool.dk • www.maerskbox.com
  Service bulletin
Upload new Star Cool controller software
with the LOGMAN
With the Star Cool unit connected to main power:
Connect the LOGMAN to the Star Cool controller
via the retriever cable to the retriever port.
                                                                                  Connect to the Star Cool
1. Turn ON the Star Cool unit and the LOGMAN.                                   controller
2. Press E on the LOGMAN and use arrows to
choose StarCool RCCU 5 and then press Enter.
3. Press D for Logman function, then E for
Flashload StarCool, finally choose the letter for
the right software to upload (RCCU0xxx.bin).
4. The display now shows: Press any key to start                                 Press e.g. Enter once, then
flashload
                                                                       switch OFF and then ON
                                                                                  the Star Cool unit.
5. Press any key e.g. Enter once - nothing will
change in the display. Now switch off the Star Cool
unit and turn it back on again. The display in the
LOGMAN will add: Flashloading
 After a short
while the display will add: Flashload completed.
6. Press ESC to exit the upload screen.
The Star Cool controller automatically reboots.
Check that the new software is stated in the start-                               Flashloading in progress
up screen. The unit is now updated with the
newest controller software.
                                                                                  Flashload completed. Press
                                                                                  ESC on the LOGMAN
  ________________________________________________________________________________________________________________________
                Bjerndrupvej 47 • 6360 Tinglev, Denmark • Phone: +45 7364 3400 • Fax: +45 7364 3569
                        CVR/SE no.: 13 82 37 74 • starcool@starcool.dk • www.maerskbox.com
   Service bulletin
With the Star Cool unit not connected to main
power:
The Star Cool unit can have software uploaded
even though it is not connected to main power.
1. Connect the LOGMAN to the Star Cool controller                                  Press and hold Wake up key
via the retriever cable to the retriever port.                                     till display illuminates.
2. Turn ON the LOGMAN.
3. Turn ON the Star Cool unit by holding the
wake up key (If in doubt refer to the Operation
and service manual) until the display will
illuminate.
4. Press E on the LOGMAN and use arrows to
choose StarCool RCCU 5 and then press Enter.                                   Connect to the Star Cool unit
5. Press D for Logman function, then E for
Flashload StarCool, finally choose the letter for
the right software to upload (RCCU0xxx.bin).
6. The display now shows: Press any key to start
flashload
7. Press any key e.g. Enter once - nothing will                                  Press e.g. Enter once,
change in the display. Now start the upload of the                                 then press twice on the
new controller software by pressing twice on the                                   wake up key on the Star
wake up key.                                                                     Cool key pad.
8. The display in the LOGMAN will add:
Flashloading
 After a short while the display
will add: Flashload completed.
9. Press ESC to exit the upload screen.                                          Flashloading in progress
The Star Cool controller automatically reboots.
Check that the new software is stated in the start-
up screen. The unit is now updated with the
newest controller software.
                                                                                   Flashload completed. Press
                                                                                   ESC on the LOGMAN.
________________________________________________________________________________________________________________________
              Bjerndrupvej 47 • 6360 Tinglev, Denmark • Phone: +45 7364 3400 • Fax: +45 7364 3569
                      CVR/SE no.: 13 82 37 74 • starcool@starcool.dk • www.maerskbox.com