Keb Drives
Keb Drives
37 … 630 kW
                GB
    With KEB COMBIVERT, reputable manufacturers have for years
    produced innovative high quality machine systems.
KEB COMBIVERT
2
                    Frequency inverter      0.37 … 15 kW
                    - the new class of compact,
                      functional and economical units
and high end open loop performance in the range of 0.37 … 630 kW
                                                                   3
    The new frequency inverter class for simple to sophisticated tasks
    throughout the mechanical engineering sector…
        •      connection 1/3 phase 230 V and 3 phase 400 V
               optional AC- or DC-supply in one unit
        •      optimized KEB - SMM control procedure
               (sensorless motor management)
        •      17 pluggable control terminals, PNP-logic
        •      analog input 0…10 V, ± 10 V, 0/ 4 … 20 mA (housing D, E)
        •      programmable analog output 0…10 V
        •      5 programmable digital inputs
        •      2 programmable relay outputs
        •      4 programmable software inputs/outputs
        •      8 free-to-programm parameter sets
               including S-curve, ramp stop, Power-Off-function,
               DC-braking, PID technology regulator, electronic motor protection,
               brake control, internal timer, counter input
        •      output frequencies up to 1600 Hz, output voltage control,
               adjustable switching frequencies up to 16 kHz
        •      controlled positioning to end position
        •      high-dynamic sampling of the control terminals and
               the serial interface in less than 2 ms
        •      + / - intermediate circuit connection,
               internal braking chopper
               motor-PTC-evaluation, hardware current control
        •      integrated filter according to EN 55011/B (option: B, D, E-housing)
        •      potential-free operator connection and
               serial interfaces for:
4
                        PN          design         IN      Imax     fnom/ fmax suppression        part
                        [kW]                      [A]      [A]       [kHz]      EN55011         number
                        0.37
                        0.75          A
                                                  1.3
                                                  2.6
                                                           2.8
                                                           5.6
                                                                       4
                                                                       4
                                                                                  B•
                                                                                  B•
                                                                                             05.F5.B3A-390A
                                                                                             07.F5.B3A-390A
    (305… 500 V)
                        11            E           24        43       4/16         B◆         15.F5.B1E-350A
                        15                        33        59         2          B◆         16.F5.B1E-340A
                   •*   incorporated in series
                        only 1-phase 230 V AC
                                                         ◆ footprint option
                                                         * * only 3-phase 230 V AC
                         General:            Product standard          EN 61800-2, -5-1
                                             Emitted interference      EN 61800-3
                                                                       EN61000-6 -1…4
                                             Enclosure                     IP 20/ VBG 4
                                             Storage temperature            -25 ... 70 °C
                                             Operation temperature          -10 ... 45 °C
                                             Short-circuit and earth fault monitoring
                                             Acceptance UL/ cUL
                                                                                                              5
                                                                                     PN    design    IN
                                                                                    [kW]            [A]
                                                                                    0.37            2.3
        - More than just a frequency inverter -                                     0.75             4
                                                                                             B*
    Leading technique for controlled drive systems                                   1.5             7
                                                                                     2.2            10
                                                                    (180… 260 V)
     ▲ wide power range for 230 V- and 400 V-connection
     ▲ optional AC- or DC-connection                                                  4       D     16.5
     ▲ optimal performance at motor shaft in various areas
       of application with KEB - SMM (sensorless motor                               5.5            24
                                                                 3 ph. 230 V
       management)                                                                   7.5
                                                                                              E
                                                                                                    33
     ▲ 29 plug-in control terminals
                                                                                     11       G     48
     ▲ 2 analog inputs 0… 10 V, ± 10 V, 0/4… 20 mA
     ▲ 2 programmable analog outputs 0… 10 V                                         15             66
                                                                                              H
     ▲ 8 programmable digital inputs                                                18.5            84
     ▲ programmable outputs: 2 x relay, 2 x transistor
                                                                                     22             100
     ▲ 4 programmable software inputs/outputs
                                                                                     30             120
     ▲ 8 freely programmable parameter sets                                                   R
                                                                                     37             150
       including S-curves, ramp stop, Power-Off-function,
       DC-braking, PID technology regulator,                                         45             180
       electronic motor protection, brake control, internal
       timer, counter input, output frequencies up to 1600
       Hz, output voltage control, switching frequencies up to                     •* 1/3internal option
                                                                                            phase 230 V
       16 kHz, output phase monitoring
     ▲ sampling time of the control terminals 2 ms
                                                                                   General:
     ▲ ± intermediate circuit connection, internal braking
       chopper (in series up to housing size G),
       motor-PTC-analysis, hardware current control
     ▲ controlled positioning to end position/counting pulse
     ▲ optional: protection against accidental restart
       by voltage-free switching in driver section
     ▲ potential-free operator connection and
       serial interfaces for
6
Imax fnom/fmax    EN           part                              PN    design     IN    Imax fnom/fmax   EN           part
[A]    [kHz] 55011            number                            [kW]              [A]   [A]     [kHz] 55011         number
                                                                 4              9.5     21        4      B◆      12.F5.C1B-350A
35.6   8/16       B ◆ 12.F5.C1D-1A0A
                                                (305… 500 V)
                                                                 11               24    48      4/16     B◆      15.F5.C1E-350A
                                             3 ph. 400 V
85      4/8       B ◆ 15.F5.C1G-150A                                     E
                                                                 15               33    59      2/16     B◆      16.F5.C1E-340A
115     16        B ◆ 16.F5.C0H-170A
150    8/16       B ◆ 17.F5.C0H-160A                            18.5              42    75      4/16     B◆      17.F5.C1G-350A
                                                                         G
                                                                 22               50    90      2/16     B◆      18.F5.C1G-340A
175    8/16       B
                      •   18.F5.C0R-760A
210
265
       8/16
       8/16
                  B
                  B▲
                      •   19.F5.C0R-760A
                          20.F5.C0R-760A
                                                                 30
                                                                         H
                                                                                  60    108     4/16     B◆      19.F5.C0H-350A
 ◆     footprint option                                          55
                                                                         R
                                                                                115     207     4/16     B
                                                                                                             •   22.F5.C0R-950A
Enclosure                     IP 20/VBG 4
Storage temperature            -25… 70 °C
Operstion temperature          -10… 45 °C
                 upto 90 kW    -10… 40 °C
Short-circuit and earth fault monitoring
Acceptance UL/ cUL
                                                                                                                                        7
                                                                                    PN     design    IN
                                                                                    [kW]            [A]
                                                                     (180… 260 V)
    equipped with all functions and characteristics of the
    KEB COMBIVERT F5 - Compact series,                                              5.5             24
    especially prepared for regulated use.                                                   E
                                                                                    7.5             33
                                                                 3 ph. 230 V
    - RESOLVER                                                                      11       G      48
       - TTL or HTL INCREMENTAL ENCODER, INITIATOR
                  - SIN/COS- ENCODER
                                                                                    15              66
                        - ABSOLUTE VALUE ENCODER                                             H
                              - HIPERFACE®, ENDAT®                                  18.5            84
                                   or Tacho
    optional in the operation methods                                               22              100
8
  Imax fnom/fmax    EN        part                             PN design    IN    Imax fnom/fmax    EN           part
  [A]    [kHz] 55011         number                           [kW]         [A]    [A]    [kHz] 55011            number
                                                               30          60     90     4/16      B◆       19.F5.M1H-35_F
                                                                     H
 150     8/16       B•   18.F5.M1R-76_A                        37          75     112     2/4       B   •   20.F5.M1H-34_F
 172     8/16       B•   19.F5.M1R-76_A
                                                               45          90     135    4/16       B•      21.F5.M1R-95_A
                                           3 ph. 400 V
                                                                                                                             9
     Based on the open modular framework of the COMBIVERT F5-
     series, in close cooperation with OEM users KEB has adapted
           modified drive systems for standard machines.
We call it
10
THE UNIFIED DRIVE platform…
e. g. KEB Open operator
the cost effective programable hardware
for software extension in single drive
applications.(C- / assembler programming,
free memory: 64 k -flash, RS 232/485
connection)
Liquid cooling
closed cooling circuit for compact
switch cabinet cooling
                                                     11
                                                                              part          R      PD
                                                                             number        [Ω]    [W]
07.BR.100-1180 180 44
                                                                          09.BR.100-1100   100     82
                                                                          10.BR.100-1683   68     120
                                                            230 V-class
                                                                          12.BR.100-1333   33     250
                                                                          15.BR.110-6563   56     620
                                                                          16.BR.110-6423   42     820
                                    Ø 5,2
                                                                          17.BR.110-6303   30    1200
                                                            400 V-class
                                                                          18.BR.226-6203   20    1700
                                            A
                                                                          19.BR.226-6153   15    2300
                         E
                         B                            C
                                                                          20.BR.226-6123   12    2900
                                                    OHM-A                 21.BR.226-6103   10    3400
                                                                          24.BR.226-6506    5     6900
                                                                          25.BR.226-6436   4.3    8100
                                 D'
                                 D
                                 A
12
                External Braking Resistor
  P6            P25        P40         A                                  B            C          D/D'           E
 [W]            [W]        [W]                                                       [mm]
                                                                                                                       OHM-A
22000           5400             3100                90                   470         96           50           455
                                                                                                                               13
     An EMC-compliant structure with efficient switch cabinet interference
     suppression is the basis for a fault-free operation of machines and systems.
     The current and voltage limiting COMBILINE modules are optimally designed
     for the requirements of the KEB COMBIVERT F5 series and support the
     application with
         line-side EMC-filters - reduce the power-related emission to the required
         limit values of EN 55011- A/B. Variants for very small discharge currents,
         IT mains or special network configurations are also available.
     •   output choke and filters reduce the voltage and current loading
         on the motor winding.
     •   sinusoidal filter protect the motor winding from voltage peaks and
         saves on shielded motor lines
     •   line reactors reduce power consumption and line feedback
     •   combination filter for input/output - space-saving „all-around supply“
         logically adapted and optimized to drive actuator.
     •   Harmonic filters create reduced system perturbations of low-frequency
         interferences of B6-fed consumers.They are the latest innovative solution
         designed by our team of highly skilled engineers to combat such problems.
         It can be designed in the planning stage and simply replace the traditional
         line reactor. Thus making possible the compliance with many international
         standards.
14
                PN design           RFI               mains             OS-Filter             motor          sinusoidal
               [kW]                 filter             choke            THD ≤ 8 %              choke             filter
                                                                                                                         st
                                                                                   st
                              10.U5.B0B-1000*
                2.2
                                                                                                                      que
                                                                                que
                                                 10.DR.F08-1551*                           10.DR.A08-1551
                                                                                                                  n re
                                                                            n re
                5.5            13.U5.B0E-2000     13.DR.A08-5641                           13.DR.A08-5641
                                                                                                               upo
                                                                         upo
                         E
                7.5            14.U5.B0E-2000     14.DR.A08-4241                           14.DR.A08-4241
                                                                                                                              15
     The universal effective tool for the use of
     KEB COMBIVERT F5 drive actuator
         complete management of equipment settings
      Accessory:
      KEB - Interface cable RS 232
      Part number 00.58.025-001D
      (together with Interface Operator 00.F5.060-2000)
      KEB - Service cable HSP5
      Part number 00.F5.0C0-0010 (1.8 m)
16
Available as COMBIVIS 5-/DOKU-CD
part number: CD.SW.010-0100
or as current file in the INTERNET
under
                                    17
                          Interface Operator, 00.F5.060-2000 / -2100
                          universal disclosed KEB protocol for
                          PC and PLC-connection
                          RS 232 / 485-connection submin-D-9
                                                                           8/NT
                                                                I N 95/9
                                           sso  r y       for W       00
                                     Acce software .020-01 n for the
                                         ve r          . S W         c tio
                                     Dri            FD         nne
                                          B COM e PC-co 6019-II,
                                      K E           th            6             / IP
                                              or ts         DIN            TCP
                                       supp ols KEB rBus and
                                               c            e
                                        proto SP5, Int
                                           E B -H
                                         K
18
                                            Digital-Operator,
                                           00.F5.060-1000
                                        display and keyboard operation
                                                         Operator 00.F5.060-A000
                                                         MODBUS SUBD9 (female) connection,
                                                         service interface for HSP5-adapter
                                                                 Operator 00.F5.060-8000
                                                                 ETHERNET RJ45 connection
                                                                 IEEE 802.3
                                                                 10Base-T (10 Mbaud),
                                                                 service interface for
          Operator 00.F5.060-7000                                HSP5-adapter
          Device Net IN-/OUT-connection Open Entry,
adapter   service interface for HSP5-adapter
                                                                                              19
     KEB COMBIVERT F5 units are designed in a flexible modular
     system and are available in the following designs:
        Internal unit class IP 20 - universal fitting in switch cabinet
        Internal unit with factory-fitted radio interference suppression filter
        for internal radio interference suppression
        Internal unit with factory-fitted braking resistor
        to absorb energy with no extra space required -
        also available in combination with interference suppression filter
        Customer version FLAT- REAR - (FR)
        direct thermal connection to coolers
        Customer version LIQUID COOLED - (LC) - liquid cooling
        Customer version EXTERNAL HEAT - (EH)
        push - through cooler for thermal decoupling
     For customer standard applications KEB also supplies
     complete control cabinet solutions in protection class IP 54.
20
   design              version IP20 B x H x T(mm)                 available customer versions
                      unit     with HF-filter   with resistor       FR        LC        EH
A 76x191x144 75x191x144 - - -
H 297x340x255 300x445x321
       R        340x520x355 342x520x360*
                            110x478x115
       U        340x800x355   110x598x240                           -                    -
      W         670x940x368   260x386x115                           -                    -
                              260x386x135
                                                                                                21
     Optimally tuned
                       synchronous motors with nominal torque up to 70 Nm
     and
                       asynchronous motors with nominal power up to 160 kW
     convert current and voltage KEB COMBIVERT F5 drive actuator
     into rotatary motion.
     Depending on the physical requirements of the application, the mechanical
     construction, motor/machine inertia conditions
     and/or the overload characteristic.
     KEB provides a powerful range of motors for inverter operation.
22
Industrial gear motors ensure the adjustment of speed and torque.
With the KEB COMBIGEAR range, a fully modular system is
available in conventional designs:
      - helical inline               - helical shaft mounted
      - helical bevel                - helical worm
Key features of the range are the finely graduated ratios,
compact construction and robust grey cast iron housings.
                                                                           23
   KEB Antriebstechnik Austria GmbH • Ritzstraße 8 • A - 4614 Marchtrenk
   Tel.: +43 (0)7243 53586-0 • FAX: +43 (0) 7243 53586 - 21
   Internet: www.keb.at • E-mail: info@keb.at
   Société Française KEB • Z.I. de la Croix St. Nicolas • 14, rue Gustave Eiffel • F - 94510 LA QUEUE EN BRIE
   Tél.: +33 (0)1 49620101 • FAX: +33 (0)1 45767495
   Internet: www.keb.fr • E-mail: info@keb.fr
   KEB (UK) Ltd. • 6 Chieftain Buisiness Park, Morris Close • Park Farm, Wellingborough, GB - Northants, NN8 6 XF
   Tel.: +44 (0)1933 402220 • FAX: +44 (0)1933 400724
   Internet: www.keb-uk.co.uk • E-mail: info@keb-uk.co.uk
   KEB - YAMAKYU Ltd. • 15 - 16, 2-Chome • J - Takanawa Minato-ku • J - Tokyo 108 - 0074
   Tel.: +81 (0) 33 445 / 8515 • FAX: +81 (0) 33 445 8215
   E-mail: ky-sales@f4.dion.ne.jp
   KEB España • C / Mitjer, Nave 8 Poligono Industrial "La masia" • E - 08799 Sant Cugat Sesgarrigues (Barcelona)
   Tel.: +34 (0) 61 83 24 766 • FAX: +34 (0) 93 8992035
   E-mail: vb.spanien@keb.de
   KEB Taiwan Ltd. • No. 8, Lane 89, Sec. 3, Taichung Kang Rd. • R.O.C. - Taichung City Taiwan
   Tel.: +886 (0) 4 23506488 • FAX: +886 (0) 4 23501403
   E-mail: info@keb.keb.com.tw
   KEB America, Inc. • 5100 Valley Industrial Blvd. South • USA - Shakopee, MN 55379
   Tel.: +1 (0) 952 224 14 00 • FAX: +1 (0) 952 224 14 99
   Internet: www.kebamerica.com • E-mail: info@kebamerica.com