www.mgeups.

com

Telecom Process & Infrastructures

Power supply conditioner


Pulsar CT
315/625/1250/3000/5000 VA

A quality power supply Ideal protection for:


◗ laboratory instruments
for protecting sensitive equipment ◗ programmable logic units, etc.

Pulsar CT protects sensitive electronic equipment


(laboratory instruments, programmable logic units, etc.):
◗ total electrical isolation,
◗ continuous voltage regulation,
◗ elimination of harmonics from the electrical power supply.
In this way, they eliminate premature damage to the electrical
components in the equipment.

Controlled…

Total electrical isolation Unrivalled performance


between the input ◗ Common mode filtering.
and the output
◗ Unlimited resistance to short-
The power supply to the application circuits.
is unaffected by any electrical fault,
◗ Continuous voltage regulation.
even a 4,000-volt lightning strike! … and regulated power supply.
◗ Protection against transients
(< 20 ms).
Continuous voltage regulation
The Pulsar CT continuously regulates
any voltage fluctuations within a range Straightforward integration
of 3 to 5 %. ◗ Compact design.
◗ Attractive appearance.
Removal of harmonics from ◗ Direct connection
the electrical power supply via output sockets
Pulsar CT filters harmonics from the (CT 3/6/12).
output voltage and from the sink ◗ 'POWER ON' indicator
current. This ensures that any lamp on the front
interference generated by the power panel.
unit (harmonic current) is not fed back ◗ Fault alarms
upstream into the electrical (CT 30/50).
power supply.
Power supply conditioner - Pulsar CT

Due to developments in technical standards and the equipment described in this document, we cannot be held liable for compliance with the characteristics indicated by the images and text unless they are confirmed by us. All the brand names referred to in this document are protected by copyright.
2 output sockets

IN
GER
MERLIN SV
sar
pul

Input connecting cable


'POWER ON' indicator lamp

Input connecting cable

RIN
LIN GE
MER
ar SV
puls

Input/Output terminal board

Publication: MGE UPS SYSTEMS (July 2004) - Design and rewriting: 3c-evolution.com - Integration: Pamplemousse: +33 4 79 37 87 66 – Translation: TTP: +33 4 78 66 47 99.
Technical characteristics
ON/OFF switch 'POWER ON' Temperature Pulsar CT CT 3 CT 6 CT 12 CT 30 CT 50
indicator lamp and ventilation Power output, VA/W 315/250 625/500 1250/1000 3000/2400 5000/4000
alarm
Input/output
Input voltage/frequency 230 V +/- 20 % ; 50 Hz
Output voltage/frequency 230 V +/- 5 % (+/- 3 % for 230 V +/- 15 % input power supply); 50 Hz
Neutral rating Switchable neutral, connected to earth
Harmonic distortion factor < 3 % of the nominal linear load
Performance
Response time 30 ms
Environment
Operating temperatures - 10°C, + 40°C
◗ USE (FR) sockets ◗ DIN sockets
Protection rating IP20
Technical standards
Interference EN 50 091 - 2 and 50 022/11 - B
Susceptibility EN 50 091 - 2 and IEC 1000 - 4 - 2 to 1000 - 4 - 5
Safety standards IEC 950/EN 60 950/EN 50 091 - 1
Connection
Inputs 1 cable with 2-phase + E terminal board
Outputs 2 USE output sockets or DIN terminal board
Dimensions and weights
Dimensions H x W x D (mm) 253 x 172 x 400 293 x 300 x 500
Net weight (kg) 10 15 25 40 51

Commercial models
MGE PowerServices™ Pulsar CT CT 3 CT 6 CT 12 CT 30 CT 50
1-year warranty. USE sockets 66291 66301 66311
Standard exchange of the product DIN sockets 66292 66312 66312
if it proves to be defective. Install 66315 66318