The document provides specifications for a series of CP-Series 24V DC power supplies. It details the units' electrical and physical characteristics including input voltage range, output voltage and current, efficiency, hold up time, temperature range, approvals, and accessories.

Uploaded by

boussai noufal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
31 views30 pages

Cp5e241 3

The document provides specifications for a series of CP-Series 24V DC power supplies. It details the units' electrical and physical characteristics including input voltage range, output voltage and current, efficiency, hold up time, temperature range, approvals, and accessories.

Uploaded by

boussai noufal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 30

CP5.241, CP5.241-C1, CP5.

241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

POWER SUPPLY
▪ AC 100-240V Wide-range Input
▪ Width only 32mm
▪ Efficiency up to 94.3%
▪ Excellent Partial Load Efficiency
▪ 20% Output Power Reserves (PowerBoost)
▪ Easy Fuse Breaking – 3 times nominal current for 12ms
▪ Safe HiccupPLUS Overload Mode
▪ Active Power Factor Correction (PFC)
▪ Minimal Inrush Current Surge
▪ Full Power Between -25°C and +60°C
▪ DC OK Relay Contact
▪ 3 Year Warranty

PRODUCT DESCRIPTION SHORT-FORM DATA


The Dimension CP-Series are cost optimized power supplies without Output voltage DC 24V Nominal
compromising quality, reliability and performance. The CP-Series is Adjustment range 24 - 28V Factory setting 24.1V
part of the DIMENSION power supply family. Output current 5.0 – 4.3A Up to +60°C ambient
The CP5.241 power supplies come with three connection terminal 3.8 – 3.2A At +70°C ambient
options: screw, spring-clamp or push-in terminals, which are Derate linearly between +60°C and +70°C
optimized for automated wiring. PowerBoost 6.0A Up to +45°C ambient
The CP5.241-C1 is equipped with conformal coating preferred for Linear decrease to nominal power between
the use in harsh environments and the CP5.242 features an +45°C and +60°C
enhanced DC input voltage range. Input voltage AC AC 100-240V -15%/+10%
Mains frequency 50-60Hz ±6%
The most outstanding features of these units are the small size, the
Input current AC 1.09 / 0.6A At 120 / 230Vac
high efficiency, the electronic inrush current limitation, active PFC
and the wide operational temperature range. The devices also offer Power factor 0.98 / 0.91 At 120 / 230Vac
PowerBoost: Power reserves of 20%, which may even be used Input voltage DC DC 110-150V ±20% For CP5.241 (-xx)
continuously at temperatures up to +45°C. Additionally, they can DC 110-300V ±20% For CP5.242
deliver 3 times the nominal output current for 12ms which helps to Input current DC 1.21 / 0.43A At 110 / 300Vdc
trip fuses on faulty output branches. AC Inrush current 5 / 6Apeak At 120 / 230Vac
Efficiency 93.6 / 94.3% At 120 / 230Vac
High immunity to transients and power surges as well as low
electromagnetic emission, a DC OK signal contact for remote Losses 8.2 / 7.3W At 120 / 230Vac
monitoring, and a large international approval package for a variety Hold-up time 35 / 35ms At 120 / 230Vac
of applications makes this unit suitable for nearly every situation. Temperature range -25°C to +70°C
Size (WxHxD) 32x124x102mm Without DIN rail
Weight 440g

ORDER NUMBERS MAIN APPROVALS


For details and the complete approval list, see chapter 19.
Power Supply CP5.241 Screw terminals
CP5.241-C1 Screw terminals and
conformal coating
CP5.241-S1 Spring-clamp terminals
CP5.241-S2 Push-in terminals UL 61010-2-201 ATEX IECEx
CP5.242 Screw terminals and
enhanced DC input
Accessory ZM10.WALL Wall/Panel mount bracket
Class I Div 2

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 1/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

INDEX
Page Page
1. Intended Use .....................................................................3 20. Regulatory Product Compliance ......................................20
2. Installation Instructions .....................................................3 21. Physical Dimensions and Weight .....................................21
3. AC-Input.............................................................................5 22. Accessories ......................................................................22
4. DC-Input ............................................................................6 22.1. ZM10.WALL - Wall/Panel Mount Bracket ............. 22
5. Input Inrush Current ..........................................................7 22.2. YR2.DIODE - Redundancy Module ........................ 23
6. Output ...............................................................................8 22.3. YR20.242 - Redundancy Module .......................... 23
7. Hold-up Time ...................................................................10 22.4. YR20.246 - Redundancy Module with Automated
8. DC OK Relay Contact ........................................................10 Load Sharing.......................................................... 23
9. Efficiency and Power Losses ............................................11 22.5. UF20.241 Buffer Module ...................................... 24
10. Functional Diagram..........................................................12 23. Application Notes ............................................................25
11. Front Side and User Elements..........................................12 23.1. Peak Current Capability ........................................ 25
12. Connection Terminals ......................................................13 23.2. Charging of Batteries ............................................ 26
13. Lifetime Expectancy .........................................................14 23.3. Series Operation ................................................... 26
14. MTBF ...............................................................................14 23.4. Parallel Use to Increase Output Power................. 26
15. EMC .................................................................................15 23.5. Parallel Use for Redundancy ................................ 27
16. Environment ....................................................................16 23.6. Operation on Two Phases..................................... 29
17. Safety and Protection Features .......................................17 23.7. Use in a Tightly Sealed Enclosure ......................... 29
18. Dielectric Strength ...........................................................18 23.8. Mounting Orientations ......................................... 30
19. Approved, Fulfilled or Tested Standards..........................19

The information given in this document is correct to the best of our knowledge and experience at the time of publication. If not expressly
agreed otherwise, this information does not represent a warranty in the legal sense of the word. As the state of our knowledge and
experience is constantly changing, the information in this data sheet is subject to revision. We therefore kindly ask you to always use the
latest issue of this document (available under www.pulspower.com).
No part of this document may be reproduced or utilized in any form without our prior permission in writing.
Packaging and packaging aids can and should always be recycled. The product itself may not be disposed of as domestic refuse.

TERMINOLOGY AND ABREVIATIONS


PE and symbol PE is the abbreviation for Protective Earth and has the same meaning as the symbol .
Earth, Ground This document uses the term “earth” which is the same as the U.S. term “ground”.
t.b.d. To be defined, value or description will follow later.
AC 230V A figure displayed with the AC or DC before the value represents a nominal voltage with standard tolerances
(usually ±15%) included.
E.g.: DC 12V describes a 12V battery disregarding whether it is full (13.7V) or flat (10V)
230Vac A figure with the unit (Vac) at the end is a momentary figure without any additional tolerances included.
50Hz vs. 60Hz As long as not otherwise stated, AC 230V parameters are valid at 50Hz mains frequency.
may A key word indicating flexibility of choice with no implied preference.
shall A key word indicating a mandatory requirement.
should A key word indicating flexibility of choice with a strongly preferred implementation.

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 2/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

1. INTENDED USE
This device is designed for installation in an enclosure and is intended for commercial use, such as in industrial control, process control,
monitoring, measurement, Audio/Video, information or communication equipment or the like.
Do not use this device in equipment, where malfunctioning may cause severe personal injury or threaten human life without additional
appropriate safety devices, that are suited for the end-application.
If this device is used in a manner outside of its specification, the protection provided by the device may be impaired.

2. INSTALLATION INSTRUCTIONS

WARNING Risk of electrical shock, fire, personal injury or death.


- Turn power off before working on the device and protect against inadvertent re-powering.
- Do not open, modify or repair the device.
- Use caution to prevent any foreign objects from entering into the housing.
- Do not use in wet locations or in areas where moisture or condensation can be expected.
- Do not touch during power-on, and immediately after power-off. Hot surface may cause burns.

Obey the following installation instructions:


This device may only be installed and put into operation by qualified personnel.
This device does not contain serviceable parts. The tripping of an internal fuse is caused by an internal defect.
If damage or malfunction should occur during installation or operation, immediately turn power off and send unit to the factory for
inspection.
Install device in an enclosure providing protection against electrical, mechanical and fire hazards.
Install the device onto a DIN rail according to EN 60715 with the input terminals on the bottom and the output terminals on the top of
the device. Other mounting orientations require a reduction in output current.
Make sure that the wiring is correct by following all local and national codes. Use appropriate copper cables that are designed for a
minimum operating temperature of 60°C for ambient temperatures up to +45°C, 75°C for ambient temperatures up to +60°C and 90°C
for ambient temperatures up to +70°C.
Ensure that all strands of a stranded wire enter the terminal connection. Use ferrules for wires on the input terminals. Unused screw
terminals should be securely tightened.
The device is designed for pollution degree 2 areas in controlled environments. No condensation or frost is allowed.
The enclosure of the device provides a degree of protection of IP20. The housing does not provide protection against spilled liquids.
The isolation of the device is designed to withstand impulse voltages of overvoltage category III according to IEC 60664-1.
The device is designed as “Class of Protection I” equipment according to IEC 61140. Do not use without a proper PE (Protective Earth)
connection.
The device is suitable to be supplied from TN, TT or IT mains networks. The continuous voltage between the input terminal and the PE
potential must not exceed 300Vac.
The input can also be powered from batteries or similar DC sources. The continuous voltage between the supply voltage and the
PE/ground potential must not exceed 360Vdc.
A disconnecting means shall be provided for the input of the device.
The device is designed for convection cooling and does not require an external fan. Do not obstruct airflow and do not cover ventilation
grid!
The device is designed for altitudes up to 5000m. Above 2000m a reduction in output current and over voltage category is required.

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 3/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

Keep the following minimum installation clearances: 40mm on top, 20mm on the bottom, 5mm left and right side. Increase the 5mm to
15mm in case the adjacent device is a heat source. When the device is permanently loaded with less than 50%, the 5mm can be reduced
to zero.
The device is designed, tested and approved for branch circuits up to 32A (IEC) and 30A (UL) without additional protection device. If an
external fuse is utilized, do not use circuit breakers smaller than 6A B- or C-Characteristic to avoid a nuisance tripping of the circuit
breaker.
The maximum surrounding air temperature is +70°C. The operational temperature is the same as the ambient or surrounding air
temperature and is defined 2cm below the device.
The device is designed to operate in areas between 5% and 95% relative humidity.

(Except CP5.242)
Installation Instructions for Hazardous Location Areas
The device is suitable for use in Class I Division 2 Groups A, B, C, D locations and for use in Group II Category 3 (Zone 2) environments.
Classification: ATEX: EPS 19 ATEX 1 201 X, II 3G Ex ec nC IIC T4 Gc / IECEx EPS 19.0078X
WARNING EXPLOSION HAZARDS!
Installation in standard mounting orientation with the input terminals on the bottom of the unit. For non-standard mounting
orientations a reduction of output current is required.
Do not disconnect the device or operate the voltage adjustment unless power has been switched off or the area is known to be non-
hazardous.
A suitable enclosure must be provided for the end product which has a minimum protection of IP54 and fulfils the requirements of the
EN 60079-0.

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 4/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

3. AC-INPUT
The device is suitable to be supplied from TN, TT or IT mains networks with AC voltage. For suitable DC supply voltages see chapter 4.

AC input Nom. AC 100-240V


AC input range 85-264Vac
264-300Vac Occasionally for maximal 500ms
Allowed voltage L or N to earth Max. 300Vac Continuous, according to IEC 60664-1
Input frequency Nom. 50–60Hz ±6%
Turn-on voltage Typ. 80Vac Steady-state value, see Fig. 3-1
Shut-down voltage Typ. 74Vac Steady-state value, see Fig. 3-1
External input protection See recommendations in chapter 2.

AC 100V AC 120V AC 230V


Input current Typ. 1.30A 1.09A 0.60A At 24V, 5A, see Fig. 3-3
Power factor Typ. 0.99 0.98 0.91 At 24V, 5A, see Fig. 3-4
Crest factor Typ. 1.7 1.8 2.2 At 24V, 5A, The crest factor is the
mathematical ratio of the peak value to
RMS value of the input current
waveform.
Start-up delay Typ. 420ms 380ms 385ms See Fig. 3-2
Rise time Typ. 80ms 80ms 80ms At 24V, 5A const. current load, 0mF load
capacitance, see Fig. 3-2
Typ. 100ms 100ms 110ms At 24V, 5A const. current load, 5mF load
capacitance,, see Fig. 3-2
Turn-on overshoot Max. 200mV 200mV 200mV See Fig. 3-2

Fig. 3-1 Input voltage range Fig. 3-2 Turn-on behavior, definitions

Rated Input
POUT input range max.
500ms Voltage
Shut -dow n

Turn-on

Output - 5%
Overshoot

Voltage
VIN
Start-up Rise
delay Time
85V 264V 300Vac

Fig. 3-3 Input current vs. output current at 24V output Fig. 3-4 Power factor vs. output current at 24V output
voltage voltage

Input Current, typ. Power Factor, typ.


1.5A (a) 1.0
(b)
1.25 0.95
a) 100Vac (a)
1.0 b) 120Vac (b)
c) 230Vac 0.9
0.75 (c)
0.5 0.85
(a) 100Vac,
(c) (b) 120Vac,
0.25 0.8 (c) 230Vac
Output Current
0 Output Current
0.75
0.5 1 2 3 4 5 6A 1 2 3 4 5 6A

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 5/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

4. DC-INPUT
The device is suitable to be supplied from a DC input voltage. Use a battery or a similar DC source. A supply from the intermediate DC-
bus of a frequency converter is not recommended and can cause a malfunction or damage the unit.
Connect +pole to L, –pole to N and the PE terminal to an earth wire or to the machine ground.

DC input Nom. DC 110-150V ±20%


For CP5.241, CP5.241-C1, CP5.241-S1, CP5.241-S2
Nom. DC 110-300V ±20%
For CP5.242
DC input range 88-180Vdc For CP5.241, CP5.241-C1, CP5.241-S1, CP5.241-S2
88-360Vdc For CP5.242
DC input current Typ. 1.21A At 110Vdc, at 24V, 5A
Typ. 0.43A At 300Vdc, at 24V, 5A
Allowed Voltage (+) or (-) input to Max. 360Vdc Continuous, according to IEC 60664-1
Earth
Turn-on voltage Typ. 74Vdc Steady state value
Shut-down voltage Typ. 67Vdc Steady state value

Fig. 4-1 Wiring for DC Input

Battery Power Supply


AC
+
L
N +
PE Load
-
-
DC

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 6/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

5. INPUT INRUSH CURRENT


An active inrush limitation circuit (NTCs, which are bypassed by a relay contact) limits the input inrush current after turn-on of the input
voltage.
The charging current into EMI suppression capacitors is disregarded in the first microseconds after switch-on.

AC 100V AC 120V AC 230V


Inrush current Max. 8Apeak 7Apeak 7Apeak At 40°C, cold start
Typ. 5Apeak 4Apeak 4Apeak At 25°C, cold start
Typ. 5Apeak 5Apeak 6Apeak At 40°C, cold start
Inrush energy Max. 0.4A²s 0.5A²s 1A²s At 40°C, cold start

Fig. 5-1 Typical turn-on behaviour at nominal load, Fig. 5-2 Typical turn-on behaviour at nominal load,
120Vac input and 25°C ambient 230Vac input and 25°C ambient

Input 50ms/DIV 4A Input 4A 50ms/DIV


current current
2A/DIV 2A/DIV

Input Input
voltage voltage
200V/DIV 200V/DIV

Output voltage Output voltage

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 7/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

6. OUTPUT
The output provides a SELV/PELV rated voltage, which is galvanically isolated from the input voltage.
The output is designed to supply any kind of loads, including capacitive and inductive loads. If extreme large capacitors, such as EDLCs
(electric double layer capacitors or “UltraCaps”) with a capacitance > 0.3F are connected to the output, the unit might charge the
capacitor in an intermittent mode.
The output is electronically protected against overload, no-load and short-circuits. In case of a protection event, audible noise may
occur.

Output voltage Nom. 24V


Adjustment range 24-28V Guaranteed value
Max. 30.0V This is the maximum output voltage which can occur at the clockwise end
position of the potentiometer due to tolerances. It is not a guaranteed
value which can be achieved.
Factory settings Typ. 24.1V ±0.2%, at full load and cold unit
Line regulation Max. 10mV Between 85 and 300Vac
Load regulation Max. 50mV Between 0A and 6A, static value, see Fig. 6-1
Ripple and noise voltage Max. 50mVpp Load >0.2A, Bandwidth 20Hz to 20MHz, 50Ohm
Max. 200mVpp Load <0.2A, Bandwidth 20Hz to 20MHz, 50Ohm
Output current Nom. 5A At 24V and up to +60°C ambient temperature
Nom. 3.8A At 24V and +70°C ambient temperature
Nom. 4.3A At 28V and up to +60°C ambient temperature
Nom. 3.2A At 28V and +70°C ambient temperature
Derate linearly between +60°C and +70°C, see chapter 16
PowerBoost1) Nom. 6A At 24V and up to +45°C ambient temperature
Nom. 5.1A At 28V and up to +45°C ambient temperature
PowerBoost decreases linearly to nominal power between +45°C and +60°C, see chapter 16
Fuse breaking current Typ. 15A Up to 12ms once every five seconds, see Fig. 6-2.
The fuse braking current is an enhanced transient current which helps to
trip fuses on faulty output branches. The output voltage stays above 20V.
Overload behaviour Continuous For output voltage above 13Vdc, see Fig. 6-1
current
Intermittent For output voltage below 13Vdc, see Fig. 6-1
current2)
Overload/ short-circuit current Max. 7.2A Continuous current, see Fig. 6-1
Typ. 9A Intermitted current peak value for typ. 1s
Load impedance 50mOhm, see Fig. 6-3
Discharge current of output capacitors is not included.
Max. 3.5A Intermitted current average value (R.M.S.)
Load impedance 50mOhm, see Fig. 6-3
Output capacitance Typ. 1 800µF Included inside the power supply
Back-feeding loads Max. 35V The unit is resistant and does not show malfunctioning when a load feeds
back voltage to the power supply. It does not matter whether the power
supply is on or off. The absorbing energy can be calculated according to
the built-in large sized output capacitor.
1) PowerBoost: This power/ current is continuously allowed up to an ambient temperature of +45°C.
Above +45°C, do not use this power or current longer than a duty cycle of 10% and/ or not longer than 1 minute every 10 minutes.
2) At heavy overloads (when output voltage falls below 13V), the power supply delivers continuous output current for 1s. After this, the output is switched off for
approx. 9s before a new start attempt is automatically performed. This cycle is repeated as long as the overload exists. If the overload has been cleared, the
device will operate normally. See Fig. 6-3.

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 8/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

Fig. 6-1 Output voltage vs. output current, typ. Fig. 6-2 Dynamic output current capability, typ.

Output Voltage Adjustment Output Voltage (dynamic behavior, < 12ms)


Range
28V 28V
24 24
A Adjustment
20 20
Range
16 16
12 12
A: continuous current
8 B: intermittent current B 8
4 4
Output Current Output Current
0 0
0 1 2 3 4 5 6 7 8 9 10A 0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25A

Fig. 6-3 Short-circuit on output, HiccupPLUS mode, typ.

Output
Current
Normal Normal
operation Short -circuit operation

9A

t
0
1s 9s 1s 9s 1s 9s

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 9/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

7. HOLD-UP TIME
The hold-up time is the time during which a power supply’s output voltage remains within specification following the loss of input
power. The hold-up time is output load dependent. At no load, the hold-up time can be up to several seconds. The green DC OK LED is
also on during this time.

AC 100V AC 120V AC 230V


Hold-up Time Typ. 70ms 70ms 70ms At 24V, 2.5A, see Fig. 7-1
Min. 55ms 55ms 55ms At 24V, 2.5A, see Fig. 7-1
Typ. 35ms 35ms 35ms At 24V, 5A, see Fig. 7-1
Min. 27ms 27ms 27ms At 24V, 5A, see Fig. 7-1

Fig. 7-1 Hold-up time vs. input voltage Fig. 7-2 Shut-down behavior, definitions

Hold-up Time
90ms a) 24V 2.5A typ. c) 24V 5A typ. Zero Transition
b) 24V 2.5A min. d) 24V 5A min.
Input
75 a Voltage
60 b
45
30
c - 5%
d
Output
Voltage
15
Input Voltage Hold-up Time
0
90 120 155 190 230Vac

8. DC OK RELAY CONTACT
This feature monitors the output voltage on the output terminals of a running power supply.

Contact closes As soon as the output voltage reaches typ. 90% of the adjusted output voltage level.
Contact opens As soon as the output voltage dips more than 10% below the adjusted output voltage.
Short dips will be extended to a signal length of 100ms. Dips shorter than 1ms will be ignored.
Switching hysteresis Typically 0.7V
Contact ratings Maximal 60Vdc 0.3A, 30Vdc 1A, 30Vac 0.5A, resistive load
Minimal permissible load: 1mA at 5Vdc
Isolation voltage See dielectric strength table in chapter 18.

Fig. 8-1 DC OK relay contact behavior

VOUT = VADJ

10% 0.9* VADJ

< >
1ms 1...4ms 100ms

open closed open closed

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 10/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

9. EFFICIENCY AND POWER LOSSES


AC 100V AC 120V AC 230V
Efficiency Typ. 92.9% 93.6% 94.3% At 24V, 5A
Typ. 92.7% 93.5% 94.5% At 24V, 6A (PowerBoost)
Average efficiency*) Typ. 91.3% 91.7% 92.0% 25% at 1.25A, 25% at 2.5A,
25% at 3.75A. 25% at 5A
Power losses Typ. 1.3W 1.3W 1.4W At 24V, 0A
Typ. 4.6W 4.4W 4.1W At 24V, 2.5A
Typ. 9.2W 8.2W 7.3W At 24V, 5A
Typ. 11.3W 9.8W 8.4W At 24V, 6A (PowerBoost)
*) The average efficiency is an assumption for a typical application where the power supply is loaded with 25% of the nominal load for 25% of the time, 50% of
the nominal load for another 25% of the time, 75% of the nominal load for another 25% of the time and with 100% of the nominal load for the rest of the
time.

Fig. 9-1 Efficiency vs. output current at 24V, typ. Fig. 9-2 Losses vs. output current at 24V, typ.
Efficiency Power Losses
95% 12W
(c) (a)
(a) 100Vac
94 10 (b) 120Vac (b)
(b)
93 (c) 230Vac
(a) (c)
92 8
91 (a) 100Vac
6
90 (b) 120Vac
4
(c) 230Vac
89
88 2
Output Current Output Current
87 0
1 2 3 4 5 6A 0 1 2 3 4 5 6A

Fig. 9-3 Efficiency vs. input voltage at 24V, 5A, typ. Fig. 9-4 Losses vs. input voltage at 24V, 5A, typ.
Efficiency Power Losses
95% 11W
94 10
93 9
92 8
91 7
90 6
Input Voltage Input Voltage
89 5
100 120 180 230 264Vac 100 120 180 230 264Vac

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 11/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

10. FUNCTIONAL DIAGRAM


Fig. 10-1 Functional diagram

L +
Input Fuse
Input Filter PFC Power Output +
N Input Rectifier Converter Converter Filter
Inrush Current Limiter -
-
Output
Voltage VOUT
Regulator

Temper- Output DC-ok


Output Output LED
ature Power Over- Voltage
Shut- Manager Voltage DC-ok
down Protection Monitor DC-ok
Relay Contact

11. FRONT SIDE AND USER ELEMENTS


Fig. 11-1 Front side

CP5.241, CP5.241-S1 CP5.241-S2 CP5.242


CP5.241-C1
A Input Terminals
N, L Line input
PE (Protective
Earth) input

B Output Terminals
Two identical + poles and two
identical - poles
+ Positive output
– Negative output
(return)

C Output Voltage Potentiometer

D DC OK LED (green)
On, when the output voltage is
>90% of the adjusted output
voltage

E DC OK Relay Contact
The DC OK relay contact is
synchronized with the DC OK
LED. See chapter 8 for details.

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 12/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

12. CONNECTION TERMINALS


The terminals are IP20 Finger safe constructed and suitable for field- and factory wiring.

CP5.241, CP5.241-C1, CP5.242 Input Output DC OK-Signal


Type Screw terminal Screw terminal Push-in terminal
Solid wire Max. 6mm2 Max. 6mm2 Max. 1.5mm2
Stranded wire Max. 4mm2 Max. 4mm2 Max. 1.5mm2
American Wire Gauge AWG 20-10 AWG 20-10 AWG 24-16
Max. wire diameter (including ferrules) 2.8mm 2.8mm 1.6mm
Recommended tightening torque Max. 1Nm Max. 1Nm -
Wire stripping length 7mm 7mm 7mm
Screwdriver 3.5mm slotted or cross- 3.5mm slotted or cross- 3mm slotted to open the
head No 2 head No 2 spring
CP5.241-S1 Input Output DC OK-Signal
Type Quick-connect spring-clamp Quick-connect spring- Push-in terminal
terminal clamp terminal
Solid wire Max. 6mm2 Max. 6mm2 Max. 1.5mm2
Stranded wire Max. 4mm2 Max. 4mm2 Max. 1.5mm2
American Wire Gauge AWG 20-10 AWG 20-10 AWG 24-16
Max. wire diameter (including ferrules) 2.8mm 2.8mm 1.6mm
Wire stripping length 10mm 10mm 7mm
Screwdriver - - 3mm slotted to open the spring
CP5.241-S2 Input Output DC OK-Signal
Type Push-in terminal Push-in terminal Push-in terminal
Solid wire Max. 2.5mm2 Max. 2.5mm2 Max. 1.5mm2
Stranded wire Max. 2.5mm2 Max. 2.5mm2 Max. 1.5mm2
Stranded wire with ferrules Max. 1.5mm2 Max. 1.5mm2 Max. 1.5mm2
American Wire Gauge AWG 24-12 AWG 24-12 AWG 24-16
Max. wire diameter (including ferrules) 2.3mm 2.3mm 1.6mm
Wire stripping length 10mm 10mm 7mm
Screwdriver 3.0mm slotted to open the 3.0mm slotted to open 3mm slotted to open the
spring the spring spring

Daisy chaining:
Daisy chaining (jumping from one power supply output to the next) is allowed as long as the average output current through one
terminal pin does not exceed 25A or 15A for the CP5.241-S2. If the current is higher, use a separate distribution terminal block as shown
in Fig. 12-2.

Fig. 12-1 Daisy chaining of outputs Fig. 12-2 Using distribution terminals

Distribution
Power Power Terminals
Supply Supply Power Power
Supply Supply
+ + - - + + - - Load
+ + - - + + - - Load
Output Output + -
Output Output + -

Maximal 15A continuous for CP5.241-S2


Maximal 25A continuous for all other units

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 13/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

13. LIFETIME EXPECTANCY


The Lifetime expectancy shown in the table indicates the minimum operating hours (service life) and is determined by the lifetime
expectancy of the built-in electrolytic capacitors. Lifetime expectancy is specified in operational hours and is calculated according to the
capacitor’s manufacturer specification. The manufacturer of the electrolytic capacitors only guarantees a maximum life of up to 15 years
(131 400h). Any number exceeding this value is a calculated theoretical lifetime which can be used to compare devices.

AC 100V AC 120V AC 230V


Lifetime expectancy 265 000h 270 000h 274 000h At 24V, 2.5A and 40°C
748 000h 764 000h 775 000h At 24V, 2.5A and 25°C
128 000h 143 000h 166 000h At 24V, 5A and 40°C
363 000h 405 000h 469 000h At 24V, 5A and 25°C
81 000h 96 000h 119 000h At 24V, 6A and 40°C
228 000h 271 000h 336 000h At 24V, 6A and 25°C

14. MTBF
MTBF stands for Mean Time Between Failure, which is calculated according to statistical device failures, and indicates reliability of a
device. It is the statistical representation of the likelihood of a unit to fail and does not necessarily represent the life of a product.
The MTBF figure is a statistical representation of the likelihood of a device to fail. A MTBF figure of e.g. 1 000 000h means that
statistically one unit will fail every 100 hours if 10 000 units are installed in the field. However, it cannot be determined if the failed unit
has been running for 50 000h or only for 100h.
For these types of units the MTTF (Mean Time To Failure) value is the same value as the MTBF value.

AC 100V AC 120V AC 230V


MTBF SN 29500, IEC 61709 800 000h 807 000h 867 000h At 24V, 5A and 40°C
1 402 000h 1 414 000h 1 510 000h At 24V, 5A and 25°C
MTBF MIL HDBK 217F 339 000h 343 000h 368 000h At 24V, 5A and 40°C;
Ground Benign GB40
490 000h 496 000h 529 000h At 24V, 5A and 25°C;
Ground Benign GB25
81 000h 83 000h 89 000h At 24V, 5A and 40°C;
Ground Fixed GF40
109 000h 111 000h 119 000h At 24V, 5A and 25°C;
Ground Fixed GF25

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 14/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

15. EMC
The EMC behavior of the device is designed for applications in industrial environment as well as in residential, commercial and light
industry environments.
The device is investigated according to EN 61000-6-1, EN 61000-6-2, EN 61000-6-3 and EN 61000-6-4.

EMC Immunity
Electrostatic discharge EN 61000-4-2 Contact discharge 8kV Criterion A
Air discharge 15kV Criterion A
Electromagnetic RF field EN 61000-4-3 80MHz-2.7GHz 20V/m Criterion A
Fast transients (Burst) EN 61000-4-4 Input lines 4kV Criterion A
Output lines 2kV Criterion A
DC OK signal (coupling clamp) 2kV Criterion A
Surge voltage on input EN 61000-4-5 L→N 2kV Criterion A
L → PE, N → PE 4kV Criterion A
Surge voltage on output EN 61000-4-5 +→- 1kV Criterion A
+ / - → PE 2kV Criterion A
Surge voltage on DC OK EN 61000-4-5 DC OK signal → PE 1kV Criterion A
Conducted disturbance EN 61000-4-6 0.15-80MHz 20V Criterion A
Mains voltage dips EN 61000-4-11 0% of 100Vac 0Vac, 20ms Criterion A
40% of 100Vac 40Vac, 200ms Criterion C
70% of 100Vac 70Vac, 500ms Criterion A
0% of 200Vac 0Vac, 20ms Criterion A
40% of 200Vac 80Vac, 200ms, <4A Criterion A
40% of 200Vac 80Vac, 200ms, >4A Criterion C
70% of 200Vac 140Vac, 500ms Criterion A
Voltage interruptions EN 61000-4-11 0% of 200Vac (=0V) 5000ms Criterion C
Powerful transients VDE 0160 Over entire load range 750V, 0.3ms Criterion A
Performance criterions:
A: The device shows normal operation behavior within the defined limits.
C: Temporary loss of function is possible. The device may shut-down and restarts by itself. No damage or hazards for the device will occur.

EMC Emission
Conducted emission EN 55011, EN 55032, FCC Part 15, CISPR 11, CISPR 32 Class B
input lines
Conducted emission IEC/CISPR 16-1-2, IEC/CISPR 16-2-1 Limits for local DC power networks
output lines fulfilled
Radiated emission EN 55011, EN 55032 Class B
Harmonic input current (PFC) EN 61000-3-2 Fulfilled for Class A equipment
Voltage fluctuations, flicker EN 61000-3-3 Fulfilled, tested with constant
current loads, non pulsing
This device complies with FCC Part 15 rules.
Operation is subjected to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.

Switching Frequencies
PFC converter 30kHz to 140kHz Input voltage and output load dependent
Main converter 60kHz to 140kHz Output load dependent
Auxiliary converter 30kHz to 60kHz Output load dependent

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 15/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

16. ENVIRONMENT
Operational temperature -25°C to +70°C Operational temperature is the same as the ambient or
surrounding temperature and is defined as the air
temperature 2cm below the unit.
Storage temperature -40°C to +85°C For storage and transportation
Output derating 3W/K Between +60°C and +70°C
0.33A/1000m or 5K/1000m For altitudes >2000m, see Fig. 16-2
The derating is not hardware controlled. The user has to take this into consideration to stay below the
derated current limits in order not to overload the unit.
Humidity 5 to 95% r.h. According to IEC 60068-2-30
Atmospheric pressure 110-54kPa See Fig. 16-2 for details
Altitude Up to 5000m See Fig. 16-2 for details
Over-voltage category III According to IEC 60664-1 for altitudes up to 2000m
II According to IEC 60664-1, for altitudes above 2000m
Degree of pollution 2 According to IEC 62477-1, not conductive
Vibration sinusoidal 2-17.8Hz: ±1.6mm; According to IEC 60068-2-6
17.8-500Hz: 2g
2 hours / axis
Shock 30g 6ms, 20g 11ms According to IEC 60068-2-27
3 bumps per direction, 18 bumps in
total
Shock and vibration is tested in combination with DIN rails according to EN 60715 with a height of
15mm and a thickness of 1.3mm and standard orientation.
Audible noise Some audible noise may be emitted from the power supply during no load, overload or short circuit.

Fig. 16-1 Output current vs. ambient temp. Fig. 16-2 Output current vs. altitude
(Inom 5A; Iout with PowerBoost = 6A)

Allowed Output Current at 24V Allowed Output Current at 24V


6A B 6A C
B
5A 5A
A A
3.8A 4A

A... Tamb < 60°C


A... 85 to 264Vac, continuous B... Tamb < 45°C
B... short term C... Short term

0
Altitude 0m 2000m 5000m
-25 0 45 60 70°C
AP*) 110kPa 80kPa 54kPa
Ambient Temperature *) Atmospheric pressure

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 16/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

17. SAFETY AND PROTECTION FEATURES


Isolation resistance Min. 500MOhm At delivered condition between input and output, measured
with 500Vdc
Min. 500MOhm At delivered condition between input and PE, measured with
500Vdc
Min. 500MOhm At delivered condition between output and PE, measured
with 500Vdc
Min. 500MOhm At delivered condition between output and DC OK contacts,
measured with 500Vdc
PE resistance Max. 0.1Ohm Resistance between PE terminal and the housing in the area
of the DIN rail mounting bracket.
Output over-voltage protection Typ. 30.5Vdc
Max. 32.0Vdc
In case of an internal defect, a redundant circuit limits the maximum output voltage.
The output shuts down and performs three restart attempts. If the failure continues, the
output shuts down. Cycle input power to reset.
Class of protection I According to IEC 61140
A PE (Protective Earth) connection is required
Degree of protection IP 20 According to EN/IEC 60529
Over-temperature protection Included Output shut-down with automatic restart.
Temperature sensors are installed on critical components
inside the unit and turn the unit off in safety critical
situations, which can happen e.g. when ambient
temperature is too high, ventilation is obstructed or the
derating requirements are not followed. There is no
correlation between the operating temperature and turn-off
temperature since this is dependent on input voltage, load
and installation methods.
Input transient protection MOV (Metal Oxide For protection values see chapter 15 (EMC).
Varistor)
Internal input fuse Included Not user replaceable slow-blow high-braking capacity fuse
Touch current (leakage current) Typ. 0.10mA / 0.27mA At 100Vac, 50Hz, TN-,TT-mains / IT-mains
Typ. 0.13mA / 0.38mA At 120Vac, 60Hz, TN-,TT-mains / IT-mains
Typ. 0.20mA / 0.60mA At 230Vac, 50Hz, TN-,TT-mains / IT-mains
Max. 0.13mA / 0.35mA At 110Vac, 50Hz, TN-,TT-mains / IT-mains
Max. 0.17mA / 0.51mA At 132Vac, 60Hz, TN-,TT-mains / IT-mains
Max. 0.27mA / 0.81mA At 264Vac, 50Hz, TN-,TT-mains / IT-mains

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 17/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

18. DIELECTRIC STRENGTH


The output voltage is floating and has no ohmic connection to the ground.
The output is insulated to the input by a double or reinforced insulation.
Type and routine tests are conducted by the manufacturer. Field tests may be conducted in the field using the appropriate test
equipment which applies the voltage with a slow ramp (2s up and 2s down). Connect all input-terminals together as well as all output
poles before conducting the test. When testing, set the cut-off current settings to the value in the table below.
We recommend that either the + pole or the – pole shall be connected to the protective earth system. This helps to avoid situations in
which a load starts unexpectedly or can not be switched off when unnoticed earth faults occur.

Fig. 18-1 Dielectric strength A B C D


Input DC-ok Type test 60s 2500Vac 3000Vac 1000Vac 500Vac
L B*) Routine test 5s 2500Vac 2500Vac 500Vac 500Vac
N
Field test 5s 2000Vac 2000Vac 500Vac 500Vac
A D Field test cut-off current > 10mA > 10mA > 20mA > 1mA
B

settings
Earth, PE Output B*)
C + When testing input to DC OK ensure that the maximal voltage between DC OK and the output is not
exceeded (column D). We recommend connecting DC OK pins and the output pins together when
- performing the test.

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 18/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

19. APPROVED, FULFILLED OR TESTED STANDARDS


IEC 61010-2-201 CB Scheme Certificate
Electrical Equipment for Measurement, Control and Laboratory Use - Particular
requirements for control equipment
UL 61010-2-201 UL Certificate
Listed equipment for category NMTR - Electrical Equipment for Measurement,
Control and Laboratory Use - Particular requirements for control equipment
Applicable for US and Canada
E-File: E198865
IEC 62368 CB Scheme Certificate
IEC 62368-1 Audio/video, information and communication technology equipment
- Safety requirements
Output safety level: ES1
ATEX Agency Certificate (Bureau Veritas)
(except CP5.242) EN 60079-0 Explosive atmospheres - General requirements
EN 60079-7, EN 60079-15 Equipment protection by type of protection "e" and "n"
Certificate: EPS 19 ATEX 1 201 X
Temperature Code: T4
Type of Protection: ec nC
IECEx IECEx Certificate
(except CP5.242) IEC 60079-0 Explosive atmospheres - General requirements
IEC 60079-7, IEC 60079-15 Equipment protection by type of protection "e" and
"n"
Certificate: IECEx EPS 19.0078X
Temperature Code: T4
Type of Protection: ec nC
Class I Div 2 UL Certificate
(except CP5.242) Listed equipment for category NRAD - Listed equipment Industrial Control
Equipment for Use in Hazardous Locations
Applicable for US and Canada
E-File: E327416
Temperature Code: T4
Groups: A, B, C and D
IEC 61558-2-16 Test Certificate
Safety of transformers, reactors, power supply units and similar products for
supply voltages up to 1100 V
Particular requirements and tests for switch mode power supply units and
transformers for switch mode power supply units
SEMI F47 Test Report
Voltage Sag Immunity for Semiconductor Processing Equipment
Tested for AC 208V L-L or L-N mains voltages, nominal output voltage and
nominal output load
VDMA 24364 Paint Wetting Impairment Substances Test (or LABS-Test)
Tested for Zone 2 and test class C1 according to VDMA 24364-C1-L/W for solvents
and water-based paints

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 19/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

20. REGULATORY PRODUCT COMPLIANCE


EU Declaration of Conformity The CE mark indicates conformance with the
- EMC directive
- Low-voltage directive
- RoHS directive
REACH Regulation (EU) Manufacturer's Declaration
EU regulation regarding the Registration, Evaluation, Authorisation and
Restriction of Chemicals (REACH) fulfilled.
EU Regulation (EC) 1907/2006.
WEEE Regulation Manufacturer's Declaration
EU Regulation on Waste Electrical and Electronic Equipment
Registered as business to business (B2B) products.
EU Regulation 2012/19/EU
KC KC Korean Certification
(except CP5.241-S2) Korean - Registration of Broadcasting and Communication Equipment
Registered under Clause3, Article 58-2 of Radio Waves Act.
Registration No. R-R-PUG-CP5_241.
CCC CCC Certificate
China Compulsory Certification (CNCA-C23-01:2019)
Certificate for devices made in Suzhou/China (PULS Electronics):
2021122303114443
Certificate for devices made in Chomutov/Czech Republic (PULS investiční):
2021122303114444
CCC-Ex
UKCA UKCA Declaration of Conformity
Trade conformity assessment for England, Scotland and Wales
The UKCA mark indicates conformity with the UK Statutory Instruments
2016 No.1091,
2016 No.1107 (CP5.241, CP5.241-C1, CP5.241-S1, CP5.241-S1)
2016 No.1101 (CP5.242)
2012 No.3032

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 20/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

21. PHYSICAL DIMENSIONS AND WEIGHT


Width 32mm
Height 124mm
Depth 102mm
The DIN rail depth must be added to the unit depth to calculate the total required installation depth.
Weight 440g
DIN rail Use 35mm DIN rails according to EN 60715 or EN 50022 with a height of 7.5 or 15mm.
Housing material Body: Aluminium alloy
Cover: Zinc-plated steel
Installation clearances See chapter 2
Penetration protection Small parts like screws, nuts, etc. with a diameter larger than 3.5mm

Fig. 21-1 Front view Fig. 21-2 Side view


CP5.241, CP5.241-S1 CP5.241-S2
CP5.241-C1,
CP5.242

All dimensions in mm
All dimensions in mm

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 21/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

22. ACCESSORIES

22.1. ZM10.WALL - WALL/PANEL MOUNT BRACKET


This bracket is used to mount the devices on a wall/panel without utilizing a DIN rail. The bracket can be mounted without detaching the
DIN rail brackets.

Fig. 22-1 Isometric view Fig. 22-2 Isometric view- Fig. 22-3 Isometric view

Fig. 22-5 Hole pattern for wall mounting Fig. 22-6 Wall/panel mounting,
Fig. 22-4 Wall/panel mounting, front view
side view

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 22/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

22.2. YR2.DIODE - REDUNDANCY MODULE


The YR2.DIODE is a dual redundancy module, which can be used to build 1+1 or N+1 redundant systems.
The device is equipped with two 10A nominal input channels, which are individually decoupled by utilizing diode
technology. The output can be loaded with a nominal 20A continuous current.
The device does not require an additional auxiliary voltage and is self-powered even in case of a short circuit across
the output.
For a safe and vibration resistant wiring, the device is equipped with time saving quick connect spring clamp
terminals.
The unit is very narrow and only requires 32mm width on the DIN rail.
See chapter 23.5 for wiring information.

22.3. YR20.242 - REDUNDANCY MODULE


The YR20.242 is a dual redundancy module, which can be used to build 1+1 or N+1 redundant systems.
The device is equipped with two input channels, each rated for 20A for ambient temperatures up to +70°C and are
individually decoupled by utilizing MOSFET technology. The inputs can also be operated up to 24A when the ambient
temperature does not exceed +45°C.
The output can be loaded with nominal 20A at +70°C or 24A at 45°C continuous current.
Using MOSFETSs instead of diodes reduces heat generation, losses and voltage drop between input and output. Due
to these advantages, the unit is very narrow and only requires 32mm width on the DIN rail.
The device does not require an additional auxiliary voltage and is self-powered even in case of a short circuit across
the output.
See chapter 23.5 for wiring information.

22.4. YR20.246 - REDUNDANCY MODULE WITH AUTOMATED LOAD SHARING


The YR20.246 is a dual redundancy module, which can be used to build 1+1 redundant systems.
The device is equipped with two input channels, each rated for 10A for ambient temperatures up to +70°C and are
individually decoupled by utilizing MOSFET technology. The inputs can also be operated up to 12A when the ambient
temperature does not exceed +45°C.
The output can be loaded with nominal 20A at +70°C or 24A at 45°C continuous current.
Using MOSFETSs instead of diodes reduces heat generation, losses and voltage drop between input and output. Due
to these advantages, the unit is very narrow and only requires 32mm width on the DIN rail.
The device does not require an additional auxiliary voltage and is self-powered even in case of a short circuit across
the output.
The device is equipped with an automated load sharing feature, which balances the load current between the two
input channels. It also monitors the function of the redundancy circuitry and provides a signal if the output current is too high, which
could prevent redundancy if one power supply fails. The signal also reports too low or too high input voltages.
See chapter 23.5 for wiring information.

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 23/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

22.5. UF20.241 BUFFER MODULE

The UF20.241 buffer module is a supplementary device for DC 24V power supplies. It delivers power to bridge
typical mains failures or extends the hold-up time after the AC power is turned off.
When the power supply provides a sufficient voltage, the buffer module stores energy in the integrated
electrolytic capacitors. When the mains voltage is lost, the stored energy is released to the DC-bus in a
regulated process.
The buffer module can be added in parallel to the load circuit at any given point and does not require any
control wiring.
One buffer module can deliver 20A additional current and can be added in parallel to increase the output
ampacity or the hold-up time.

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 24/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

23. APPLICATION NOTES

23.1. PEAK CURRENT CAPABILITY


The unit can deliver peak currents (up to several milliseconds) which are higher than the specified short term currents.
This helps to start current demanding loads. Solenoids, contactors and pneumatic modules often have a steady state coil and a pick-up
coil. The inrush current demand of the pick-up coil is several times higher than the steady-state current and usually exceeds the nominal
output current. The same situation applies when starting a capacitive load.
The peak current capability also ensures the safe operation of subsequent circuit breakers of load circuits. The load branches are often
individually protected with circuit breakers or fuses. In case of a short or an overload in one branch circuit, the fuse or circuit breaker
need a certain amount of over-current to open in a timely manner. This avoids voltage loss in adjacent circuits.
The extra current (peak current) is supplied by the power converter and the built-in large sized output capacitors of the power supply.
The capacitors get discharged during such an event, which causes a voltage dip on the output. The following three examples show
typical voltage dips for resistive loads:

Fig. 23-1 10Apeak current for 50ms , typ. Fig. 23-2 25Apeak current for 5ms , typ.
(2x the nominal current) (5x the nominal current)

24V Output
Output Voltage
24V Voltage

25A 14V
16V

10A

Output
0A Current
1ms/DIV Output
10ms/DIV 0A Current

Fig. 23-3 15Apeak current for 12ms , typ.


(3x the nominal current)

24V

15A Output Voltage


10.5V
12ms
Output Current
0A

10ms/DIV Please note: The DC OK relay triggers when the voltage dips more
than 10% for longer than 1ms.

Peak current voltage dips Typically from 24V to 16V At 10A for 50ms and resistive load
Typically from 24V to 16.5V At 25A for 2ms and resistive load
Typically from 24V to 14V At 25A for 5ms and resistive load

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 25/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

23.2. CHARGING OF BATTERIES


The power supply can be used to charge lead-acid or maintenance free batteries. Two 12V SLA or VRLA batteries are needed in series
connection.
Instructions for charging batteries:
a) Use only matched batteries when putting 12V types in series.
b) Ensure that the ambient temperature of the power supply stays below 40°C for mains voltage of AC 120V or higher and 35°C for a
mains voltage of AC 100V.
c) Use a 10A circuit breaker or a blocking diode between the power supply and the battery.
d) Ensure that the output current of the power supply is below the allowed charging current of the battery.
e) The return current to the power supply is typically 8mA. This return current can discharge the battery when the power supply is
switched off except in case a blocking diode is utilized.
f) Set the output voltage, measured at no load and at the battery end of the cable, very precisely to the end-of-charge voltage. The
voltage should be set to 27.8V at 10°C, 27.5V at 20°C, 27.15V at 30°C and 26.8V at 40°C ambient temperature.

Unit A
23.3. SERIES OPERATION Input
+
Devices of the same type can be connected in series for higher output voltages. It is
possible to connect as many units in series as needed, providing the sum of the output -
Output
voltage does not exceed 150Vdc. Voltages with a potential above 60Vdc must be installed +
with a protection against touching. Unit B
Load
Input
Avoid return voltage (e.g. from a decelerating motor or battery) which is applied to the + -
output terminals.
-
Keep an installation clearance of 15mm (left / right) between two power supplies and Output
avoid installing the power supplies on top of each other. Do not use power supplies in
series in mounting orientations other than the standard mounting orientation.
Pay attention that leakage current, EMI, inrush current, harmonics will increase when using multiple devices.

Unit A
23.4. PARALLEL USE TO INCREASE OUTPUT POWER Input
+
Devises can be paralleled to increase the output power. The output voltage shall be
adjusted to the same value (±100mV) with the same load conditions on all devices, or the -
Output
devices can be left with the factory settings. +
Unit B
The ambient temperature is not allowed to exceed +40°C. Load
Input
If more than three devices are connected in parallel, a fuse or circuit breaker with a rating + -
of 10A is required on each output. Alternatively, a diode or redundancy module can also
-
be utilized. Output
Energize all devices at the same time. It also might be necessary to cycle the input power
(turn-off for at least five seconds), if the output was in overload or short circuits and the required output current is higher than the
current of one unit.
Keep an installation clearance of 15mm (left / right) between two devices and avoid installing devices on top of each other. Do not use
devices in parallel in mounting orientations other than the standard mounting orientation or in any other condition where a reduction of
the output current is required (e.g. altitude).
Pay attention that leakage current, EMI, inrush current will increase when using multiple devices.

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 26/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

23.5. PARALLEL USE FOR REDUNDANCY


1+1 Redundancy:
Devices can be paralleled for redundancy to gain higher system availability. Redundant systems require a certain amount of extra power
to support the load in case one device fails. The simplest way is to put two devices in parallel. This is called a 1+1 redundancy. In case
one device fails, the other one is automatically able to support the load current without any interruption. It is essential to use a
redundancy module to decouple devices from each other. This prevents that the defective unit becomes a load for the other device and
the output voltage cannot be maintained any more.
1+1 redundancy allows ambient temperatures up to +70°C.
Pay attention that leakage current, EMI, inrush current, harmonics will increase when using multiple devices.
Recommendations for building redundant power systems:
- Use separate input fuses for each device.
- Use separate mains systems for each device whenever it is possible.
- Monitor the individual devices. Therefore, use the DC OK signal of the device.
- It is desirable to set the output voltages of all devices to the same value (± 100mV) or leave it at the factory setting.

N+1 Redundancy:
Redundant systems for a higher power demand are usually built in a N+1 method. E.g. four devices, each rated for 5A are paralleled to
build a 15A redundant system.
Pay attention that leakage current, EMI, inrush current, harmonics will increase when using multiple devices.
Keep an installation clearance of 15mm (left / right) between two devices and avoid installing the devices on top of each other.
Do not use devices in parallel in mounting orientations other than the standard mounting orientation or in any other condition, where a
reduction of the output current is required.
For N+1 redundancy the ambient temperature is not allowed to exceed +40°C.

Wiring examples:
Fig. 23-4 1+1 Redundant configuration for 5A load current with a dual redundancy Fig. 23-5 1+1 Redundant configuration with active load share for 5A load current
module with a dual redundancy module

Failure
Monitor
+ + - - + - + - + + - - + + - - + + - - - - + + Load
Output Output 1 2 Share
Output Input Input Output Input Input
24V,5A 24V,5A
24V,5A 1 2 24V,5A Warning
Load Share o
DC- o DC- o OK o
DC- o DC- o
OK OK OK o OK o o
o YR20.242 o Redudnadcy
Redundancy OK o
Power Module Power Power Power Failure
Supply Supply Supply Supply YR20.246 Monitor
Redundancy
Module
Input Output Input Input Input Output
L N PE - + L N PE L N PE L N PE - +
5A max.
Load 5A
opt ional

Load

I I
I I
opt ional

L L
N
N
PE
PE
Note: A YR2.DIODE can also be used instead of a YR20.242

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 27/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

Fig. 23-6 N+1 Redundant configuration for 15A load current with multiple power supplies and redundancy modules

Failure
Monitor
+ + - - + - + - + + - - + + - - + - + - + + - -
Output Input Input Output Output Input Input Output
24V,5A 1 2 24V,5A 24V,5A 1 2 24V,5A

DC- o DC- o DC- o DC- o


OK o YR20.242 OK o OK o YR20.242 OK o
Redundancy Redundancy
Power Module Power Power Module Power
Supply Supply Supply Supply

Input Output Input Input Output Input


L N PE - + L N PE L N PE - + L N PE
15A
Load
opt ional

I I I I

L
N
PE

Note: A YR2.DIODE can also be used instead of a YR20.242

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 28/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

23.6. OPERATION ON TWO PHASES


Power Supply
The power supply can also be used on two-phases of a three-phase-system. Such a L1 AC
phase-to-phase connection is allowed as long as the supplying voltage is below

240V +10% max.


240V+10%. L
Ensure that the wire, which is connected to the N-terminal, is appropriately fused. L3 N
The maximum allowed voltage between a Phase and the PE must be below 300Vac. PE

L2 DC

23.7. USE IN A TIGHTLY SEALED ENCLOSURE


When the power supply is installed in a tightly sealed enclosure, the temperature inside the enclosure will be higher than outside. In
such situations, the inside temperature defines the ambient temperature for the power supply.
The following measurement results can be used as a reference to estimate the temperature rise inside the enclosure.
The power supply is placed in the middle of the box, no other heat producing items are inside the box
The temperature sensor inside the box is placed in the middle of the right side of the power supply with a distance of 1cm.
The following measurement results can be used as a reference to estimate the temperature rise inside the enclosure.
Case A Case B
Enclosure size 110x180x165mm 110x180x165mm
Rittal Typ IP66 Box Rittal Typ IP66 Box
PK 9516 100, PK 9516 100,
plastic plastic
Input voltage 230Vac 230Vac
Load 24V, 4A; (=80%) 24V, 5A; (=100%)
Temperature inside the box 38.3°C 39.6°C
Temperature outside the box 26.1°C 25.5°C
Temperature rise 12.2K 14.1K

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 29/30
www.pulspower.com Phone +49 89 9278 0 Germany
CP5.241, CP5.241-C1, CP5.241-S1,
CP5.241-S2, CP5.242
CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT

23.8. MOUNTING ORIENTATIONS


Mounting orientations other than input terminals on the bottom and output on the top require a reduction in continuous output power
or a limitation in the maximum allowed ambient temperature.
The listed lifetime and MTBF values from this datasheet apply only for the standard mounting orientation.
The following curves give an indication for allowed output currents for altitudes up to 2000m.

Fig. 23-7 Allowed Output Current at 24V


Mounting OUTPUT 6A
Orientation A 5A
(Standard
orientation) Power 3.8A
Supply

0
INPUT +45 +60 +70°C
Ambient Temperature

Fig. 23-8 Allowed Output Current at 24V


Mounting INPUT
6A
Orientation B
(Upside down) 4A
Supply
Pow er

OUTPUT 0
+30 +60 +70°C
Ambient Temperature

Fig. 23-9 Allowed Output Current at 24V


Mounting 6A
Orientation C
(Table-top
mounting) 3.5A

0
+25 +60 +70°C
Ambient Temperature

Fig. 23-10 Allowed Output Current at 24V


Mounting 6A
Orientation D
(Horizontal cw)
OUTPUT
Supply
Pow er

3.5A
INPUT

0
+25 +60 +70°C
Ambient Temperature

Fig. 23-11 Allowed Output Current at 24V


Mounting 6A
Orientation E
(Horizontal ccw)
OUTPUT

Supply

3.5A
Pow er

INPUT

0
+25 +60 +70°C
Ambient Temperature

Oct. 2023 / Rev. 1.4 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted. 30/30