UVC GERMICIDAL
TECHNOLOGY
                                    APPLICATIONS IN HOSPITALS
                  Germicidal UV Technology to Inhibit Microbial Growth
                      and Limit Transfer of Infections in Hospitals
UVC can be utilized to inhibit microbial growth and transfer in
hospitals through installation in HVAC systems and stand-alone
fixtures as follows:
       Cooling Coil disinfection (a): Installation of UVC fixtures for
        direct irradiation of the cooling coils
       Air disinfection in duct system(a): Installation of in-duct
        UVC air cleaners
       Air disinfection in-Room : In-room UVC fixtures can be
        used for upper air disinfection
       Surface Sterilization: With direct UVC fixtures
       UVC for Operating Rooms: A unique combination of air
        and surface sterilization systems specifically designed for
        Operating Rooms.
       Sterilization of occupied and unoccupied rooms: Portable
        UV sterilizers to use in unoccupied rooms and portable
        sterilizers for occupied rooms.
(a): See our information bulletin “UVC Applications in HVAC
systems” .
                Air disinfection & surface sterilization in Operating Room
OR (Operating Room) UVC sterilization is a specifically developed sterilization solution. Ensuring a sterile
environment is very important for preventing complications during organ transplantation or open joint
surgical procedures. Achieving and maintaining a sterile environment in operating rooms is crucial for
patients with weak immune systems due to cancer or AIDS. Operating room UVC sterilization package
compiles all implementations of the germicidal UV technology to ensure the required clean environment.
Operating Room UVC sterilization is achieved with two distinctive, although overlapping processes. First,
before the operating room is occupied by people, it is entirely irradiated with direct UVC fixtures that
sterilize all surfaces exposed to the UV rays. These fixtures must be turned off or turned down before
personnel or patients enter the operating room. Second, the air of the operating room is irradiated with
indirect germicidal fixtures to ensure sterile environment and stop the transfer of pathogenic or toxic
microorganisms through air. The indirect fixtures stay on all the time. They either enclose the UV lamps or
are equipped with louvers that direct the UV light to areas above eye level.
_____________________________________________________________________________
INNOVATIONS TECHNICAL EQUIPMENT TRADING CO LLC. P.O. Box 31206, Dubai, UAE.
Tel: 971 4 2629700, Fax: 971 4 2629367, E-mail: itete@eim.ae              Bulletin AME-UV010810 Page 1 of 7
                                         UVC GERMICIDAL
                                          TECHNOLOGY
                                    APPLICATIONS IN HOSPITALS
                 UVGI OPERATING ROOM EQUIPMENT “PACKAGE”
          FOR REDUCING SURGICAL SITE INFECTIONS (See layout next page)
                       Reduced infection rates mean:
                             Fewer post-operation complications
                             Fewer deaths & less insurance cost.
                             Fewer repeated procedures
          Direct SM Fixtures                   Indirect Wall Mounted                   Door Barrier
           (ceiling mounted)                  Upper Air UVGI Fixtures                  UV Fixtures
Surface Mounted SM units. There are        Wall mounted 7.5’ - 8’ above     Mounted over all access doors to
a total of eight (8) of these fixtures.    Floor. Typically installed on    operating suite to provide a
Four (4) are positioned around the         opposite walls to cover room     protective “curtain” of UV energy.
O.R. table, one on either side, and one    area appropriately. Fixtures     Fixtures operate at full power
at each end. The remaining four (4)        operate all full power at all    during procedures.
are positioned equidistant from each       times, even during procedures.   Microorganisms are blocked from
other around the perimeter of the                                           entering or exiting the operating
room.                                                                       theater when doors are opened.
    Variable Transformer (dimmer)                 UVC Radiometer               Safety during operation
Wired to Direct, Surface-Mounted SM        IL-1400 Meter & Sensor: This UVC safety goggles and UV
fixtures. Acts as a “dimmer” to dial       device measures the intensity absorbing cream are provided
down lamp intensity to desired level       of UV light on the O.R. table. with package to ensure safety of
(23 μW/cm²) at the surgical site.          The sensor is placed on the all personnel in OR.
Adjustability allows maximum lamp          O.R. table. The measurement
life use.                                  of UV intensity is expressed in
                                           μW/cm².
_____________________________________________________________________________
INNOVATIONS TECHNICAL EQUIPMENT TRADING CO LLC. P.O. Box 31206, Dubai, UAE.
Tel: 971 4 2629700, Fax: 971 4 2629367, E-mail: itete@eim.ae                Bulletin AME-UV010810 Page 2 of 7
                                         UVC GERMICIDAL
                                          TECHNOLOGY
                                    APPLICATIONS IN HOSPITALS
                      Complete UV Package for Operating Room
           A sample layout of the direct SM-36-200 UV fixtures shown below.
     The TB-36-W systems are wall mounted and stay at full power at all times during procedure for
      upper air disinfection.
     The DB-36 system is installed above the door to create a UV curtain for air disinfection. The DB
      systems also stay at full power during operation procedures. More than one DB UV fixtures may be
      required depending on the width of the door.
     The SM-36-200, are direct germicidal UV systems installed in various patterns on the ceiling above
      the operating table. The UV intensity of these fixtures is controlled by a variable transformer to
      avoid over-exposure during surgery.
_____________________________________________________________________________
INNOVATIONS TECHNICAL EQUIPMENT TRADING CO LLC. P.O. Box 31206, Dubai, UAE.
Tel: 971 4 2629700, Fax: 971 4 2629367, E-mail: itete@eim.ae            Bulletin AME-UV010810 Page 3 of 7
                                         UVC GERMICIDAL
                                          TECHNOLOGY
                                    APPLICATIONS IN HOSPITALS
                    UVGI HOSPITAL MOBILE & PORTABLE PRODUCTS
MRS MOBILE ROOM STERILIZERS (UNOCCUPIED ROOM)
Model MRS3684P/220
These mobile 8-lamp UV sterilizers feature 2-minute "ON" delay
and 24-hour timer for total room irradiation. They are designed for
operating rooms, sterile areas, laboratories, unoccupied patient
rooms, clean rooms and all other applications where permanent
fixtures are not practical. Each unit is equipped with casters for
maximum portability.
Effective area: 30' x 40' – 20 minutes
UV lamps: 8 Nos. GML100 lamps 36” (120μW/cm² @ 1m each lamp)
Lamps rated life if used continuously: 12,000 hours
Voltage: 220V /1Ph /50 Hz
Dimensions - 20”L x 20”W x 48”H
RM9U105/50 PORTABLE 1 LAMP AIR CLEANER(OCCUPIED ROOM):
Portable one lamp UV air cleaner to cover up to 200 square feet.
The UV light is directed so the room can be occupied while the unit
is ON.
Features:
     Internal Air Filter
     High intensity 9W germicidal UV lamp
     Light weight – 8 lbs
     Compact unit – 5½” x 9½” x 7¼”
     Variable speed fan 10 –100 cfm (220 v/1 Ph/50Hz)
     Lamp effective life: 10,000 hours
PORTABLE UN AIR PURIFIER AP600-2 LAMPS (OCCUPIED ROOM):
The AP-600/50 portable air purifiers utilize 2 high intensity UV
lamps and cover up to 300 square feet. The UV light is enclosed so
the room can be occupied.
Features:
     Electrostatic Air Filter
     Light weight – 10 lbs
     Compact unit – 10” x 10” x 10”
     Variable speed fan 10 –100 cfm (220v/1 Ph/50 Hz)
_____________________________________________________________________________
INNOVATIONS TECHNICAL EQUIPMENT TRADING CO LLC. P.O. Box 31206, Dubai, UAE.
Tel: 971 4 2629700, Fax: 971 4 2629367, E-mail: itete@eim.ae          Bulletin AME-UV010810 Page 4 of 7
                                         UVC GERMICIDAL
                                          TECHNOLOGY
                                    APPLICATIONS IN HOSPITALS
                           UVGI HOSPITAL- PORTABLE PRODUCTS
HANDHELD UV SURFACE STERILIZER
The AAW Handheld UV wand is a portable direct germicidal UV
system for surface disinfection. It can help control the growth of
germs such as viruses, bacteria, mold and mold spores and reduce
spreading of infections. AAW Handheld UV wand is a portable
system for applications where a permanent UVC installation is not
desired or needed. The UV system can help reduce or eliminate
microbial contamination in spaces that do not need constant
exposure to UVC light. Common environments include laboratories,
hospitals and food plants. The High Output UV lamp emits high
intensity UV so the system should be positioned in a way to avoid
exposing people to direct or reflected UV light.
System’s features:
- On/off switch
- Safety glasses
- Tool-free lamp change
- 14" high output shatterproof lamp
- 6’ three-prong power cord
- Oversized handle
- Spectrally polished reflector
AAW-TBE-14-1 UV PORTABLE OR WALL MOUNTED UV SYSTEM:
The AAW-TBE-14-1 is a totally enclosed air-movement germicidal UV
system for in-room control of airborne TB and flu, as well as other
airborne viruses, bacteria and mold. AAW-TBE-14-1 is designed to be
portable or wall mounted. The system features stainless, steel
chassis, pull-chain switch, power cord, a fan and two filters. The High
Output UV lamp is completely enclosed so the system can be ON at
all times protecting personnel and providing maximum germicidal
irradiation.
Features and Benefits:
      Improves Indoor Air Quality (IAQ) by reducing airborne
         bacteria, viruses, mold and spores
      Reduces the risk of airborne transmission of cold, flu, TB and
         other illnesses
      High output UV lamp.
_____________________________________________________________________________
INNOVATIONS TECHNICAL EQUIPMENT TRADING CO LLC. P.O. Box 31206, Dubai, UAE.
Tel: 971 4 2629700, Fax: 971 4 2629367, E-mail: itete@eim.ae              Bulletin AME-UV010810 Page 5 of 7
                                         UVC GERMICIDAL
                                          TECHNOLOGY
                                    APPLICATIONS IN HOSPITALS
        UVGI HOSPITAL- SURFACE-MOUNT DIRECT SURFACE UV STERILIZERS
SM SURFCAE MOUNTED FIXTURES:
Designed to be mounted to (or suspended from) ceilings. Surface
Mounted fixtures incorporate a spectrally polished aluminum
reflector designed for maximum dispersion of UVC energy
throughout a room. The unique shape prevents dust and sediment           SM-36 and SM-36-2 have electronic
from settling on the reflector surface and, thus improves fixture        ballast which can automatically
efficiency. Surface Mount fixtures are 5.625" wide with a depth of       handle 110/220/277V / 50/60Hz. For
4.125", with the exception of Guard Rail fixtures. Guard Rail fixtures   all other models, voltage must be
are 4.625" in depth.                                                     specified when ordering. All ballasts
                                                                         are UL Listed.
Available in 18 ½”, 27” or 37” length, in single or double lamps.
RT RECESSED TROFFERS UV OR UV + LIGHTING:
These germicidal ultraviolet fixtures are constructed of die-formed,
one-piece steel and highly reflective aluminum. They are
manufactured to meet hospital, pharmaceutical, clean room and
laboratory ultraviolet requirements. Two models are available, with
two lamps (RT-36-2G) or four germicidal lamps (RT-36-4G). Also
available in 2 germicidal lamps + 2 fluorescent illumination lamps
combination (RT-2G2C).                                                   Dimensions: 4’ L x 2’ W x 4¼” D)
     Ceiling height up to 9.5': One RT-36-2G per 75sq. ft. or one
         RT-36-4G per 125sq. ft. fixtures required.
     Ceiling height 9.5' to 11': One RT-36-2G per 50sq. ft. or one
         RT-36-4G per 100sq. ft. fixtures required.
     Ceiling height 11' to 14': One RT-36-2G per 40sq. ft. or one
         RT-36-4G per 70sq. ft. fixtures required.
CE Closed End Germicidal UV Surface Sterilizers
In various models with UV lamp configurations of one to four, the CE
UV surface sterilizers direct and confine the ultraviolet light to
disinfect specific areas. The Closed End reflector UV surface
sterilizers are designed for use over conveyor lines, laboratory         Dimensions:
benches and ventilation hoods or with adjustable legs for UV             18" L x 7-1/4" W x 7-1/2" D)
product sterilization. UV lamp lengths of 4, 6, 8, 12, 18, 27 & 36       27" L x 7-1/4" W x 7-1/2" D
inches are available with germicidal ultraviolet (UVC) and/or            37" L x 7¼" W x 7½" D
backlight ultraviolet. Lengths 18”, 27” and 37” with up to 4 lamps.
_____________________________________________________________________________
INNOVATIONS TECHNICAL EQUIPMENT TRADING CO LLC. P.O. Box 31206, Dubai, UAE.
Tel: 971 4 2629700, Fax: 971 4 2629367, E-mail: itete@eim.ae                Bulletin AME-UV010810 Page 6 of 7
                                         UVC GERMICIDAL
                                          TECHNOLOGY
                                    APPLICATIONS IN HOSPITALS
          UVGI HOSPITAL- UPPER ROOM AIR UV STERILIZERS
WALL MOUNT TB-W PASSIVE MODELS:
Models TB-W are designed to be wall-mounted to reduce upper air
contamination. TB-W fixtures feature adjustable louvers to allow
unlimited direction of the ultraviolet rays while protecting personnel
and providing maximum germicidal irradiation. The units are               The TB in-room fixtures control
constructed of high grade stainless steel with an alzak aluminum          tuberculosis, as well as other
reflector. They mount 7 feet above the floor and use SBL lamps. TB-       airborne pathogens and mold.
W fixtures include a grounded power cord, pull-chain switch,              TB-12-W/50, 18 ½”L for 75 M2 area
ultraviolet lamp and louver. The TB in-room fixtures control              TB-24-W/50, 27 ¾”L for 200 M2 area
tuberculosis, as well as other airborne pathogens and mold.               TB-36-W/50, 37 ½”L for 300 M2 area
FAN POWERED ROOM AIR STERLIZER RAM36-2:
The RAM36-2 is a totally enclosed air-movement UV system. This
fixture comes complete with filters, fans and 2 ultraviolet lamps. It is
designed for rooms where congestion or ceiling height prohibits the
use of wall-mounted indirect fixtures. Constructed of high grade
                                                                         RAM36-2, 47 ¼”L, 100 CFM airflow,
stainless steel, each fixture produces four or more air changes per
                                                                         covers 200 Ft2 area
hour in rooms up to 200 square feet.
CORNER MOUNT CM15 UV AIR CLEANER:
Designed to mount in room corners with two keyhole slots at a
height of seven feet (7’), these attractive indirect UV air cleaners
incorporate one high intensity UV lamp and cover up to 75 square
feet. The Corner Mount UV air cleaner’s optional equipment
includes an eight-foot power cord and an on/off switch.
The high intensity UV lamp is installed with reflectors for equal
distribution of the germicidal UV irradiation. The louver restricts and
concentrates the ultraviolet rays above eye level so personnel can
occupy the room while the air cleaners are operating.
DOOR BARRIERS GERMICIDAL FIXTURES:
DB-36 UV air cleaner is fabricated of heavy gauge electro-welded
steel with white enamel finishing. By creating a curtain of germicidal
ultraviolet rays, this UV air cleaner provides effective control of
airborne microorganisms between areas. It confines the germicidal Dimensions: 37"L x 7"H x 4"D
UV radiation to a narrow beam, providing full coverage of a three- UV Lamp positioned behind louvers
foot doorway. Larger openings require multiple UV air cleaners.
_____________________________________________________________________________
INNOVATIONS TECHNICAL EQUIPMENT TRADING CO LLC. P.O. Box 31206, Dubai, UAE.
Tel: 971 4 2629700, Fax: 971 4 2629367, E-mail: itete@eim.ae                 Bulletin AME-UV010810 Page 7 of 7