ThermoStar Refrigeration Air Dryers
Why Dry Compressed Air?
Contamination                                     These problems can be avoided with
                                                  the correct selection and application of
Reduces Efficiency                                compressed air filters and dryers from
The air we breathe contains contamination         Ingersoll-Rand.
in the form of water vapor and airborne
particles.
During the compression process an air
compressor concentrates these contaminants
and depending on the design and age will
even add to the contamination in the form
of oil carry over.
Modern air compressors generally have             Corrosion
built in aftercoolers that reduce the discharge
temperature of the compressed air and with
the help of water separators, remove the
bulk of liquid water.
In some applications this may be sufficient,
but the remaining dirt and moisture content
suspended in aerosol form, can, if not
removed, damage the compressed air                Reduced Paint Quality
system and reduce product quality.
                        INCREASED
    AIR CONTAMINATION
                          SYSTEM
                         DOWNTIME
                          REDUCED                 Damaged tools
                        PRODUCTION
                         EFFICIENCY
                                                  The Air Solutions Group at Ingersoll-Rand
                                                  has the widest selection of products and
                                                  application knowledge to protect your
The result - higher overall cost of operation     investment and your compressed air system.
from:
                                                  ■ Filters               ■ Refrigeration dryers
■ Increased system downtime
                                                  ■ Condensate            ■ Desiccant
■ Reduced production efficiency
                                                    management              dryers
                                                  ■ Cooling systems ■ Piping systems
2
ThermoStar Dryers - The ‘Class’ Solution
Quality Matters                                                                             Totally Environmentally Friendly
Ingersoll-Rand ThermoStar Refrigeration                                                                                  R407C Refrigerant
Dryers are available in over 20 model sizes                                                                              Use of environmentally
to suit all applications. When installed with                                                                            friendly R407C
compressed air filters they will provide clean                                                                           refrigerant ensures
compressed air to the classes as prescribed                                                                              compliance with the
in ISO 8573.1.                                                                              Montreal Protocol. With no proposed ‘phase out’
                                                                                            of this refrigerant, the dryer will not have to be
                                                                                            replaced prematurely.
                                                        Over 20
                                                        models
                                                        available
                                                                                                            Energy Efficient
                                                                                                            Use of R407C refrigerant can
                                                                                                            reduce dryer running costs by
                                                                                                            10% when compared to widely
                                                                                                            used R134a.
                                                                                            The use of modern technology scroll refrigeration
ISO 8573.1 Quality Classes                                                                  compressors (3 phase units) will reduce energy
Quality       Dirt          Water Pressure Dewpoint                             Oil
                                                                                            consumption by a further 20%.
 Class    Particle size        Pressure Dewpoint                        (Including vapor)
           in Micron      ppm. vol. at 100 psig (7 barg)                       ppm
                             °F       (°C)      ppm.vol.                      0.01
                                                                                                             Fully Recyclable
  1                0.1      -100      (-70)       0.3                         0.01                           Fully recyclable materials
  2                1        -40       (-40)        16                          0.1                           used throughout.
  3                5         -4       (-20)       128                           1
  4                15        38        (3)        940                           5                            Compact dryer design means
  5                40        45        (7)       1240                          25                            fewer raw materials requiring
  6                 -        50       (10)       1500                           -                            disposal at the end of its
                                                                                                             useful life.
Installation Guide
                                                                                                            Energy Saving Control
                                                                                                            Fitted on models TS200 -
                                                                                                            TS3000, an electronic controller
                                                                                                            provides ‘at a glance’ indication
                                                           ThermoStar
                                                                                                            of dryer performance. An integral
                                                                                                            energy saving control system
                                                                                            also reduces power consumption during
          Sierra
                                                                                            stand-by periods.
Air Quality - With correct selection, the above schematic relates to an installation that would provide
Class 1 dirt, Class 4 water, and Class 1 oil. This is recommended to stop downstream corrosion,
prevent product spoilage and prolong the life of pneumatic tools and the compressed air system.
                                                                                                                                                  3
Superior Design
Visual Performance Indicator
Fitted on models TS10 - TS200,
this provides instant indication
of dryer performance.
Hot Gas By-Pass Valve
Prevents evaporator freezing.
Refrigerant Scroll Compressors
Fitted on models TS200 - TS3000.
✓ Consumes 20% less energy
✓    Robust
✓    Immediate Start Up
                                        Easy Access
✓    50% fewer moving parts
                                        Easy access to condensate drain simplifies
✓    Lower vibration and noise levels   routine cleaning and maintenance.
                                        Standard on TS10-TS1000.
Electronic Controller
With integral energy savings            Capillary Expander
and remote control alarm.               No moving parts provides simplicity
Standard on TS250-TS3000.               and reliability.
4
Cross Flow Heat Exchanger
Benefits
✓     Simple, modern design                          Cold air then flows from the outlet of the
✓     Compact and lightweight                        dryer via the cross flow air to air heat
                                                     exchanger where it is heated by the
✓     Designed for efficiency
                                                     incoming air, preventing condensation build
✓     Modular design                                 up on the outside of downstream piping.
✓     Reduced risk of leaks
      Six stage moisture separation                  The crossflow heat exchanger modules
✓
                                                     have been specifically designed to fully
The heart of the dryer is the specially              optimize R407C refrigerant which is now
designed cross flow heat exchanger                   the most utilized HFC refrigerant and is
module which incorporates air to air,                widely available around the world.
air to refrigerant heat exchangers and a
high efficiency stainless steel demister             Using R407C and the cross flow heat
separator in one compact unit.                       exchanger module allows the refrigeration
                                                     circuit to be smaller than equivalent R134a
The incoming air is first pre-cooled by warm         systems, providing a compact design.
air exiting the dryer as it passes through the
air to air heat exchanger. This pre-cooling
reduces the refrigeration circuit by as much
as 60%. The air is then cooled even further
as it passes through the air to refrigerant
heat exchanger coupled to the evaporator.
While at it’s coolest, the air is passed through
the minimum resistance integral high efficiency
demister separator where both liquid and
water aerosols are condensed into
                                               Air
liquid water and removed from the
                                             Inlet
air stream. This system ensures
minimum air pressure losses while ensuring
efficient water removal.
                                             Air
                                           Outlet
                                                                                  Condensate
                                                                                    Outlet
                                          Used on models TS50 - TS3000.
                                                                                                   5
Compressed Air Filters
High quality compressed air is no longer
a luxury, it is essential. Compressed air
contains contamination, and if not removed,
will damage the compressed air system
and cause product spoilage. The correct
selection and application of Ingersoll-Rand
compressed air filters will protect your air
system and increase production efficiency.
                                                                         Ask for Filter brochure
System Saver                                                                   Ref 3198
Condensate Drains
Removing oily, acidic condensate from
any compressed air system is essential,
as even a small volume can seriously affect
downstream pneumatic equipment and
processes.
Ingersoll-Rand System Saver electronic level    Ask for Drain brochure
                                                       Ref 3199
sensing drains detect and discharge only
when condensate is present. Intelligent oper-
ation always ensures no unnecessary loss of
valuable compressed air.
                                                                                                   7
Technical Specifications
                    Nominal       60Hz Models                                                                               Dimensions mm
                                                                Standard                  Maximum                                             Weight
     Model          Air Flow       Absorbed                                                                    Air
                                                                Electrical                Pressure
                      cfm             Kw                                                                   Connections                         lbs.
                                                                 Supply                      psi                             A       B   C
    TS-100             100               0.73               115 - 1ph - 60Hz                  175            1-1/2 NPT      24     31    22    143
    TS-150             150               0.83            208/230V - 1ph - 60Hz                175            1-1/2 NPT      24     31    22    146
    TS-200             200               1.19            208/230V - 1ph - 60Hz                175            1-1/2 NPT      24     31    22    154
    TS-250             250               1.89            208/230V - 1ph - 60Hz                175              2 NPT        36     40    26    309
    TS-325             325               1.89            208/230V - 1ph - 60Hz                175              2 NPT        36     40    26    309
    TS-400             400               1.89              460V - 3ph - 60Hz                  175              2 NPT        36     40    26    317
    TS-500             500               2.59              460V - 3ph - 60Hz                  175              2 NPT        36     40    26    331
    TS-700             700               3.33              460V - 3ph - 60Hz                  175          3" ANSI 150#     40     59    52    882
    TS-800             800               3.33              460V - 3ph - 60Hz                  175          3" ANSI 150#     40     59    52    926
    TS-1000           1000              4.68               460V - 3ph - 60Hz                  175          3" ANSI 150#     40     59    52    992
    TS-1200           1200              4.68               460V - 3ph - 60Hz                  175          3" ANSI 150#     40     59    52    992
    TS-1400           1400              6.76               460V - 3ph - 60Hz                  175          4" ANSI 150#     40     59    52   1036
    TS-1650           1650              8.70               460V - 3ph - 60Hz                  175          4" ANSI 150#     40     59    52   1046
    TS-2000           2000              9.50               460V - 3ph - 60Hz                  175          6" ANSI 150#     40     59    52   1301
    TS-2400           2400              10.13              460V - 3ph - 60Hz                  175          6" ANSI 150#     40     59    52   1311
    TS-3000           3000              10.13              460V - 3ph - 60Hz                  175          6" ANSI 150#     40     59    52   1455
Performances refer to air-cooled models.
Capacity ratings, in accordance with recommended Standard CAGI Standard
No. ADF 100 for Class H (33-39°F) pressure dewpoint and are based on 100 PSIG inlet air pressure, 100°F inlet air temperature,
100% relative humidity, 100°F ambient air temperature and 5 PSIG maximum pressure drop
(1) Shipping weight is approximate.
(2) For other voltages consult factory.
(3) kW and full load amps are based on actual test but nameplate data should be used for sizing wire and circuit breakers.
    Nameplate according to UL/CUL requirements and is based on maximum conditions.
    INLET                                   Inlet Air Pressure psig / (barg)                                   PRESSURE DEWPOINT
TEMPERATURE              60      80       90       100    120     125      150    175     200*     220         Range °F / (°C)  Factor
   °F / (°C)            (4.1)   (5.1)    (6.2)    (6.9) (8.2) (8.6) (10.3)        (12)   (13.8)   (15.2)       33-39 / (.6-3.9)   1
                                              Flow (% of Rated Capacity)                                      40-44 / (4.4-6.7)  1.1
      80 / (26.7)        1.2    1.42     1.46     1.53    1.56    1.62     1.69   1.76   1.77     1.81        45-49 / (7.2-9.4)  1.2
      90 / (32.2)       0.97    1.14     1.18     1.23    1.25     1.3     1.36   1.41   1.49     1.53        50-54 / (10-12.2)  1.3
     100 / (37.8)       0.79    0.93     0.96       1     1.02    1.06     1.11   1.15   1.21     1.24
     110 / (43.3)       0.65    0.76     0.79     0.82    0.83    0.86     0.91   0.94     1      1.03        AMBIENT TEMPERATURE
     120 / (48.9)       0.54    0.63     0.65     0.68    0.68    0.72     0.75   0.78   0.82     0.84         Range °F / (°C) Factor
                                                                                                              100 F / (37.8 C)   1
*Please contact Ingersoll-Rand when selecting above 175psig on models TS-50 to TS-3150.
                                                                                                              110 F / (43.3 C)  0.95
                                                                                                              120 F / (48.9 C)  0.88
    Dryer Selection
    Refrigeration dryers must be sized correctly. Flowrates are shown only for the
    operating conditions specified at 100 psig (7 barg).
    To select a dryer for the following conditions use the correction factors given:
    Example:
    Customer Flowrate               115 cfm          3.3 m3/min
    Inlet Temperature               110°F            43°C
                                                                           (correction factor .79)
    System Pressure                 90 psig          6.2 barg                                                                                     B
    Dewpoint                        37°F             3°C                   (correction factor 1.0)
    Ambient temperature             110°F            43°C                  (correction factor .95)
    Step 1          115 cfm             = 146 cfm (4.1 m3/min)
                     0.79
                                                                    Therefore selection = TS-200                                                 C
                     146 cfm            = 153 cfm (4.3 m3/min)
    Step 2                                                                                                                       A
                    .95 x 1.0
6
                  More Than Parts. Solutions.
                                Online answers: htttp://www.air.ingersoll-rand.com
Ingersoll-Rand air compressors are not designed, intended or approved for breathing air. Compressed air should not be
used for breathing air applications unless treated in accordance with all applicable codes and regulations.
Nothing contained in this brochure is intended to extend any warranty or representation, expressed or implied, regarding
the products described herein. Any such warranties or other terms and conditions of sale shall be in accordance with
Ingersoll-Rand’s standard terms and conditions of sale for such products which are available upon request.
Product improvement is a continuing goal at Ingersoll-Rand. Designs and specifications are subject to change without
notice or obligation.
                                                                     Ingersoll-Rand Company   Air Solutions Group
                                                                                              800-D Beaty Street
                                                                                              P.O. Box 1600
                                                                                              Davidson, NC 28036
                                                                                              www.air.ingersoll-rand.com
© 2000 Ingersoll-Rand Company   Form 3200 Printed in USA