Completely Independent Dual System Hydraulic Test Stand: 930 Series

The document describes a hydraulic test stand featuring a completely independent dual system that allows each system to operate independently or together. It includes detailed specifications on the pumps, motors, filters, gauges, controls, and safety features of the test stand.

Uploaded by

Sajad Karimi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
245 views5 pages

Completely Independent Dual System Hydraulic Test Stand: 930 Series

The document describes a hydraulic test stand featuring a completely independent dual system that allows each system to operate independently or together. It includes detailed specifications on the pumps, motors, filters, gauges, controls, and safety features of the test stand.

Uploaded by

Sajad Karimi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

930

COMPLETELY INDEPENDENT DUAL SYSTEM Series


HYDRAULIC TEST STAND
Our Competent Engineering Staff Ensures You are Provided with the Exact
2 Year
Hydraulic Testing Equipment for Current and Future Applications Warranty
Which Will Increase Your Profitability

Model 07-932-05

Complete Hydraulic Test Stand, Featuring


Dual Systems with High Pressure Intensifier

9283 Industrial Blvd. Leland, NC 28451 USA


Voice 910.371.1151 Fax 910.371.1152
ap-hydraulics.com
930
Series
COMPLETELY INDEPENDENT DUAL SYSTEM
HYDRAULIC TEST STAND

STANDARD FEATURES:
· Completely Independent Dual System · Instrumentation – All Gauges Feature Easy
· Each System May be Used Independently Programmability for Field Calibration
or Combined Together for Maximum Flows · Five Digital Flow Meters (1% Accuracy)
· Will Deliver Different Pressures and Flows 1. System A Pump Supply Flow
Simultaneously 2. System B Pump Supply Flow
· Two Separate Work Stations for System A & B 3. System A Return Flow
4. System B Return Flow
· System A 5. Low Range (.4 – 7 GPM)
1. Oilgear® Pump · Seven Digital Pressure Gauges (.25% Accuracy)
2. Lincoln® Motor 1. System A Supply Pressure
3. Complete Pressure Adjustment (450 – 5000 PSI) 2. System B Supply Pressure
4. Complete Flow Adjustment (0 – Full GPM) 3. Return Back Pressure
5. Pressure and Return Ports 4. Low Independent Pressure Gauge
6. Digital Pressure Gauges (.25% Accuracy) 5. Medium Independent Pressure Gauge
7. Digital Supply and Return Flow Meters 6. High Independent Pressure Gauge
(1% Accuracy) 7. Intensifier Pressure Gauge
8. Safety Over Pressure Relief Valve
9. By-Pass Dump Valve · Air Over Oil Intensifier
10. Pump Flow Control Valve 1. Digital Pressure Gauge (.25% Accuracy)
11. Pump Pressure Control Valve 2. Air Shut-Off Valve
3. Air Regulator
· System B 4. Safety Over Pressure Relief Valve
1. Oilgear® Pump 5. By-Pass Dump Valve
2. Lincoln® Motor 6. Dedicated Port
3. Complete Pressure Adjustment (450 – 5000 PSI)
4. Complete Flow Adjustment (0 – Full GPM) · Safety Features
5. Pressure and Return Ports 1. Two Ergonomically Located Emergency
6. Digital Pressure Gauges (.25% Accuracy) Stop Switches
7. Digital Supply and Return Flow Meters 2. Safety Over Pressure Relief Valves for Both
(1% Accuracy) System A and B
8. Safety Over Pressure Relief Valve 3. Safety Drip Pan Completely Covers Bottom
9. By-Pass Dump Valve to Ensure Clean Floors
10. Pump Flow Control Valve 4. All Electrical Components Installed in
11. Pump Pressure Control Valve NEMA 4, 12 Enclosure
5. All Gauges are Fully Enclosed in NEMA 4. 12
· Five Pumps Enclosure with a Clear Front Safety Glass Cover
1. Oilgear® System A Pressure Compensated Pump 6. Operational LED Warning Indicator Lights
2. Oilgear® System B Pressure Compensated Pump 7. Dual Heavy Duty Floor Locks to Ensure Stability
3. S/C® High Pressure Intensifier Pump (10,000 PSI) 8. Optional Safety Glass Sliding Doors for Work
4. Work Sink Drain Pump Sink
5. Reservoir Kidney Loop Pump

9283 Industrial Blvd. Leland, NC 28451 USA


Voice 910.371.1151 Fax 910.371.1152
ap-hydraulics.com
930
Series
COMPLETELY INDEPENDENT DUAL SYSTEM
HYDRAULIC TEST STAND
· Super Clean Filtration – Industry Leading · Automatic Oil Temperature Control
Filtration Ensures Quality While Increasing · Panel Mounted Oil Temperature Set Point
Aircraft Component Life · Digital Oil Temperature Gauge
· System A & B High Efficiency, Non-Bypass
Pressure Filters (3 Micron Absolute) · Return Back Pressure for Dynamically
· Reservoir Kidney Loop Filter (3 Micron Absolute) Loading Components
· Sink Drain Filter (3 Micron Absolute) · Return Back Pressure By-Pass Valve
· Reservoir Fill Pump Filter (3 Micron Absolute) · Return Back Pressure, Pressure Adjustment
Valve
· 4-Way Directional Flow Control Valve · Return Back Pressure, Pressure Gauge
Manually Operated 4-Way Directional Flow · Return Back Pressure Flow Meter
Control Valve with Complete Flow Control
to Either Port A or Port B · Additional Features
· All Welded, 14 Gauge B3 (Brushed Finish)
· Hedland® Digital Low Flow Return Meter with Stainless Steel Cabinet
Electric Selector Valve for Testing Internal Leakage · Illuminated Work Area Provided
of Components (.4 - 7 GPM Standard) By Overhead Sink Light
· Test Port for all Pressure Gauges
· Operational Warning Lights · Easy Access Exterior Fluid Sampling
1. System A & B Pressure Filter Condition Valve to Meet Quality Parameters
LED Warning Indicator for Clogged Conditions · Safety Drip Pan Completely Covers Bottom
2. Kidney Loop Pump Filter Condition · Work Sink with Perforated Metal Grating
LED Warning Indicator · Heavy Duty All Welded 1/4" Think Wall Tubing Frame
3. Reservoir Low Level LED Warning Indicator with Fork Lift Brackets
4. High Fluid Temperature LED Warning Indicator · Easy Maneuvering Ensured by Two Fixed and
Two Swivel Castors with Stability Provided by
· 3 Each Stand Alone Noshock® Pressure the Heavy Duty Floor Lock
Gauges (.25% Accuracy) · Work Sink Drain Pump with Filter (4 GPM)
* Suggested Ranges 0-60 PSI, 0-1000 PSI, · Durable Laser Engraved, Aluminum Placards
0-7500 PSI · Panel Mounted Operational Instructions
· Over Pressure Gauge Savers on All Gauges · Current Pressure Gauge and Flow Meter
Certificates of Calibration
· Reservoir Kidney Loop Pump
· Continuously Filters Fluid
· Continuously Cools Fluid

Dimensions: Length 112" Width 80" Height 77"


SPECIFICATIONS:
MOTOR COMBINED TOTAL
PUMP
COMBINED PUMP FLOW WEIGHT
SERIES MODEL PRESSURE
TOTAL 50 Hz 60 Hz Lbs. (kg)
PSI (bar)
HP (kw) GPM (lpm) GPM (lpm)
450 - 5000 PSI 120 HP 41 GPM 50 GPM 4700 lbs
07-932-**
30 - 340 bar 88 kw 155 lpm 189 lpm 2132 kg
450 - 5000 PSI 150 HP 54 GPM 65 GPM 5600 lbs
07-934-**
30 - 340 bar 112 kw 204 lpm 246 lpm 2540 kg
450 - 5000 PSI 200 HP 66 GPM 80 GPM 6400 lbs
07-936-**
30 - 340 bar 149 kw 250 lpm 302 lpm 2903 kg
**Model by Fluid Type: Mil-H-5606 = 02 Mil-H-83282 = 03 Skydrol = 05

9283 Industrial Blvd. Leland, NC 28451 USA


Voice 910.371.1151 Fax 910.371.1152
ap-hydraulics.com
System B System A System A System B
Press Press Return Return
Isolated Pressure Gauges Port Port Port Port
Port Port
A B

Press Gauge Press Gauge

System A System B
4-Way Valve Return Flow Return Flow
Meter Meter
Gauge Gauge By-Pass
Protector Protector By-Pass
Relief
High Medium Low
Pressure Pressure Pressure Relief
Gauge Gauge Gauge

Low Range Return


Flow Meter Flow Meter Back
Flow Meter
Pressure
Work Sink Flow Meter
Selector Pressure
Valve Gauge

Sink Drain Return Back


Pump Cross Over
Pressure By-Pass

Oil OT

*
Filter Press Filter
*

Press Filter

*
Switch

*
∆ Switch Low Level
∆ Switch
Swtich

10,000 PSI Static Loop Filter Loop Pump

*
System B System A ∆ Swtich
Test System Press Control Press Control
Intensifier
Port

Pressure System A System B Water to Oil


Gauge Flow Control Flow Control Cooler

Pressure
Relief Oil Cooled
Valve Water Solenoid

Air Over Oil System B System A


Intensifier Pump Pump
y
x Case Drain Case Drain
Filter Filter

Series 930 Hydraulic Test Stand Schematic


930
Series
Ordering Instructions
Step 1: Determine Size of the Hydraulic Test Stand Required, Refer to Aircraft's Component Overhaul Manuals For:
A. Maximum (GPM) Gallons Per Minute
B. Maximum (PSI) Pound Per Square Inch
C. Testing Procedures and Operation of Components
Step 2: Refer to Aircraft's Component Overhaul Manuals for Type of Hydraulic Fluid.
Step 3: Determine the input voltage the Hydraulic Test Stand will be operated on. When ordering, the most common
error is selecting incorrect input voltages 50 Hertz the flow will be reduced by 17%
Step 4: Call A&P Hydraulics experienced sales staff for any questions for explanation of the complete range of
Hydraulic Test Stand Options that we offer.