Operator system for Garage Doors
GB
Operating Instructions
1. Meaning of symbols 2. Table of contents
Type: ________________________________________________
4.1 / 1 1
8
4.1 / 4
3
9 !¯
9 Adapter sleeve
1 Comfort 220.2, 250.2, 252.2, 250.2 speed 10 Screw 4.0 x 10
motor unit
2 Support plate
3 Door link 4.1 / 5 !#
4.1 / 2
!1
5
4 !” !£
11 Screw 6 x 14 (4x)
12 Hexagonal head screw M6 x 20 (2x)
7 13 Self-tapping screw 6.3 x 16 (4x)
14 Bolt A8 with locking plate
!6 !9 „1 4.1 / 8
„” „#
Rail type 2
4.1 / 9
§1
„£
4.2 / 1
Supply package
• Check the package to ensure that all the parts are
included.
Door system
Reference:
i When using and installing accessories,
always observe the specific instructions
included with the equipment.
Installation, rail type 1 1. Push the adapter sleeve onto the drive shaft.
6.1 / 4
2. Mount the rail on the motor housing.
2
2 1
Attention!
The drive boom (C) must be carefully
mounted on the motor unit (F).
Do not use force, as this could damage
the gear teeth!
Attention!
In order to ensure that the door balance
is correct:
- the lintel joining plate for the operator
rail must be mounted at the mid
point, above the door connector,
- at the highest point reached by the door,
the upper edge of the door leaf must
be 10 - 50 mm below the horizontal
Attention! underside of the operator rail.
The drive boom (C) must be carefully
mounted on the motor unit (F).
Do not use force, as this could damage 6.2 / 1 Installation on the up-and-over door.
the gear teeth!
10 - 50 mm
1. Push the adapter sleeve onto the drive shaft.
6.1 / 8
2. Mount the rail on the motor housing.
2
3
1
2 2
1
Connection of signal light (optional)
Mount the suspension cramps at the The connection of a signal light is only possible with a
6.3 / 2
mounting positions. signal light relay (not included in the scope of delivery).
Attention!
To avoid damaging the cable insulation,
the cable must be laid in such a way
that it does not come into contact with
the illuminant in the motor unit.
15°- 30°
Reference:
i The programming of the signal light is
described in level 1, menu 7 and in
level 3, menu 7.
6.5 Release
Rail type 1
2
1
1
2
Caution! 6.6 / 1
Danger of electric shock:
Before any cabling works begin, it must
be ensured that the cables are XB01
disconnected from the power supply.
During cabling works, it must be
ensured that the cables remain
disconnected from the power supply at
all times (e.g. prevent reconnection).
3 1 2 7071
Attention!
In order to avoid damaging the
controls:
- The local safety regulations must be XB10 XP020 XB70
complied with at all times.
- It is very important that mains cables
are laid separately from control
cables. Label Type / function i
- The controls voltage must be 24 V DC.
- If external voltages are applied at 6.6 / 2,
Connection of external control
terminals XP020, XB10 or XB01, the XB01 elements without system cabling
9.3 /
entire electronic system will be Level 5 /
and two-wire photocell
destroyed. Menu 1
- Only potential-free normally open
contacts may be connected to XB10
Connection of external control
-
terminals 1 and 2 (XB01). elements with system cabling
- The shorting plug should never be
plugged into the XP020 system socket! Connection of system photocell
9.3 /
XP020 or adapter cable for modular
Level 8
antenna
Reference:
i When installing external control
elements, or safety and signal
equipment, the relevant instructions
must be observed.
Advice:
Before connecting a control element to
the terminals with system sockets, the
corresponding shorting plug must first
be removed.
M08E004
1 GND (0 V)
2 Impulse
3 24 V DC (max. 50 mA)
70 GND
70 + 71 Two-wire photocell
Advice:
If a photocell with a standard function
or door frame function is used, it must
be disconnected from the mains before
installing it and taking it into service.
After switching on the mains voltage,
the photocell is only detected automati-
cally by the controls if the path of the
photocell beam remains uninterrupted
for at least 5 seconds.
Otherwise the photocell must be
programmed after installation.
7.1 / 1 Overview.
1 E
F
• Whilst keeping the button on the master transmitter
depressed, press the desired button on the other
7.1 / 3 Accessory sun visor clip. hand transmitter. The LED flashes.
Advice:
- After the hand transmitter has been
re-programmed, the operator system
must also be re-programmed to
respond to the new code.
- For multi-channel transmitters, the
programming process must be carried
out for each button separately.
8.2 Overview of the control unit 8.3 Overview of the display functions
A B D
Door in OPEN position
8 1 2
7 3 1
2 P
6 54
Door is at intermediate position
Button (p)
(e.g. to switch to
D -
programming mode or
to save parameters)
Legend:
LED off
LED on
LED flashes slowly
LED pulses
LED flashes quickly
Factory default setting
Not possible –
Attention! Preconditions
To ensure correct operation, the path of The following conditions must be assured before
the photocell beam must not be inter- express programming can commence:
rupted during the express programming - the door must be in the CLOSED end position.
procedure. - the carriage must be connected up.
Exception: The door leaf in conjunction
with a photocell in the door frame Advice:
area. When programming the OPEN and
CLOSED door positions, the reference
point must be passed.
Advice:
- For proper initial operation of the
operator system, the express The controls are programmed using the plus (+),
programming procedure must be minus (-) and (P) buttons.
carried out. This applies for initial If no buttons are pressed within 120 seconds while in
operation and after a reset. programming mode, the controls revert to operating
- A photocell in the door frame area is mode. A corresponding message is displayed.
automatically programmed during
express programming. No additional Reference:
programming steps are necessary for
this purpose.
i The messages are explained in
Section 10.
- A door frame position that has been
programmed for a photocell can only
be deleted by resetting the control. • Carry out the express programming according to the
- After altering the door frame position, following procedure.
a reset must be carried out followed
by express programming.
Legend:
LED off
LED on
LED flashes slowly
LED pulses
LED flashes quickly
Factory default setting
Not possible –
Operating
Drive the door to the OPEN
mode 2.
position
8.5.1 Learning run for determining 8.5.2 Checking the automatic cut-out
the driving power
Check: Caution!
After express programming and after The automatic cut-out must be
making changes to the programming correctly programmed for the CLOSE
menu, the following learning runs and and OPEN directions to prevent damage
checks must be carried out. to persons or property.
The operator system determines the maximum required Automatic cut-out, OPENING
driving power during the first two runs after setting For drive systems where the door has openings in the
the end positions of the door. door wing (diameter of opening > 50 mm):
• Operate the operator system (with the door coupled) • Apply a load of 20 kg to the middle of the lower
to drive the door once from the CLOSED position to edge of the door whilst the door is running.
the OPEN position and back to the CLOSED position
without interruption. The door must stop immediately.
Advice:
- The photocell connected in the door
frame area must function above the
position in which it is installed.
The function below the installation
position is suppressed by the control.
- If several photocells are connected, all
photocells react analogue with any
photocell in the door frame area.
Photocell
• Activate each of the photocells in turn.
- - -
+ + +
Operating End
mode programming
Level 4 Menu 3 Higher value
- - -
+ + +
> 5 sec.
Level 3 Menu 2 Parameter
- - -
+ + +
- - -
+ + +
> 5 sec.
Levels-Exit Menu 8
- -
+ +
> 5 sec.
Level 8
-
+
Door movement /
Menu 7: Signal light Warning: flashing
Door stoppage: off
Legend:
LED off
LED on
LED flashes slowly
LED pulses
LED flashes quickly
Factory default setting
Not possible –
Press-and-release
Level 8 – System settings Menu 4: Operating modes
(OPEN/CLOSE)
Caution!
Important factory default settings can be changed using the extended functions.
All the parameters must be set correctly to avoid damage to persons or property.
Menu 7: Relay output (only programmable with optimum signal light relay)
A7 B7 C7 D7 E7 F7 G7 H7 I7 J7 K7 – – – – –
Menu 8: RESET
A8 B8 C8 D8 E8 F8 – – – – – – – – – –
Attention!
After a reset, all the parameters revert to the factory settings.
In order to ensure that the controls operate properly:
- all the required functions must be re-programmed,
- the remote control unit must be re-programmed,
- the drive system must be driven once to the OPEN and CLOSED door positions.
Advice:
- Only the intermediate position that was programmed last can be used.
- If an automatic closing timer is activated (Level 3 / Menu 1), the relay output (Level 1 / Menu 7) cannot
be programmed.
Reference:
i If changes are made in Menus 3 and 4 in Level 1, a new performance check must be carried out
(Section 8.5).
Setting Function (with optional signal light relay only) Explanation / Advice i
Level 3
A7 Signal light Function
Menu 7
G7 Problem - -
Level 5 /
H7 Lighting Lighting duration
Menu 4
Menu 8: Reset
* All connected and operational safety devices are recognised automatically after resetting.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OFF 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OFF 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Caution!
After switching off or increasing the automatic cut-out increments (Menu 3 and 4):
To exclude any risk of injury, the tests specified in EN 12453 and EN 12445 for validating the correct
limitation of force must be performed.
Legend:
LED off
LED on
LED flashes slowly
LED pulses
LED flashes quickly
Factory default setting
Not possible –
A1 B1 C1 D1 E1 F1 G1 H1 – – – – – – – –
1 2 5 10 15 20 25 30 35 40 45 50 55 60 65 70
0 1 2 3 4 5 6 7 – – – – – – – –
A7 B7 C7 D7 E7 F7 – – – – – – – – – –
Advice:
- The automatic closing timer can only be programmed if a photocell barrier is connected.
- The functions in Menu 1 can be altered as desired via the time settings in Menus 3 and 4.
Legend:
LED off
LED on
LED flashes slowly
LED pulses
LED flashes quickly
Factory default setting
Not possible –
Door open
Warning time Automatic
Setting duration Other functions
(seconds) closing timer
(seconds)
A1 - - deactivated -
B1 15 5 activated
D1 60 8 activated
E1 15 5 activated
G1 60 8 activated
Advice:
Without a connected photocell or closing prevention device, only parameter A1 can be adjusted.
C7 flashing flashing
D7 lighting lighting
E7 flashing lighting
F7 lighting flashing
Reference:
i The signal light connection can be adjusted in level 1, menu 7.
LED 7 flashes slowly -> press the hand transmitter button -> LED 7 flashes quickly
A1 B1 C1 D1 E1 – – – – – – – – – – –
Setting Function (with optional signal light relay only) Explanation / Advice
C1 closing prevention device only in CLOSE direction – normally closed contact only
Reference:
i - The programming of the special function is dependent on terminal XB01.
Terminal XB01 is described in Section 6.6.
- The lighting duration programmed is only active when the relay output (Level 1 / Menu 7) is
programmed for lighting (H7).
– – – – – – 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
A Comfort 220.2
B Comfort 250.2
C Comfort 252.2
D Comfort 250.2 speed
Reference:
i If changes are made in Menus 1, 2, 3, 4, 6 and 8 in Level 6, a new performance check must be carried
out (Section 8.5).
Menu 1: Photocell
A1 B1 C1 D1 – – – – – – – – – – – –
A3 B3 C3 D3 – – – – – – – – – – – –
A4 B4 C4 D4 – – – – – – – – – – – –
A5 B5 – – – – – – – – – – – – – –
A6 B6 – – – – – – – – – – – – – –
Attention!
If a photocell is connected, it is automatically recognised by the controls after MAINS ON.
The photocell can be reprogrammed later.
Legend:
LED off
LED on
LED flashes slowly
LED pulses
LED flashes quickly
Factory default setting
Not possible –
Menu 1: Photocell
Photocell 1 Photocell 2
Setting (Connection XP020) (Connection XB01 - Terminal 70/71)
Door movement, CLOSE Door movement, CLOSE
1
Door reverses a little: The drive system moves the door a short distance in the opposite
direction in order to free an obstacle.
2
Door reverses completely: The drive system moves the door to the opposite end position.
LED 8 does not light up. - No voltage. - Check that the mains power supply is operational.
- Check the connection to the mains power supply.
- Thermal overload protection in power - Allow the power transformer to cool down.
transformer was activated.
No reaction on impulse. - The connection terminals for the - Try temporarily disconnecting any key switches or interior
“impulse” button were by-passed, push buttons that are connected to the control unit
e.g. due to a short-circuit or flattened (Section 6.6): remove the cable from socket XB10, insert
terminals. the shorting plug and look for cabling errors.
No reaction on impulse from - Module antenna is not plugged in. - Connect the module antenna to the control unit
hand transmitter. (Section 8.1).
- The hand transmitter coding does not - Activate hand transmitter again (Section 8.4).
correspond to the receiver coding.
Operator reverses when - The programming of the photocell in - Carry out a reset of the control (section 9.4 / level 1 /
the door frame photocell is the door frame area was not menu F8), repeat express programming again (section 8.4).
interrupted. performed correctly.
Message 7 - If no buttons are pressed within 120 seconds, the programming mode terminates automatically.
- OPEN and CLOSED door positions programmed without passing the reference point.
Message 8 - Reference point button defective. - Have the operator system checked.
Message 10 - Door movement too stiff. - Ensure that the door moves easily.
- Door blocked.
- Maximum driving power setting is too - Have the max. driving power (Section 9.3 / Level 2 /
low. Menu 1+2) checked by an expert.
Message 15 - External photocell interrupted or - Remove obstacle or have the photocell checked.
defective.
Message 16 - Power sensor for the automatic - Have the motor unit checked.
cut-out is defective.
Message 26 - Undervoltage, operator system - Have the external power supply checked.
overloaded at maximum power - Ensure that the door moves easily.
setting, 16.
Message 28 - Door movement too stiff or irregular. - Check the path of the door and ensure that the door moves
- Door blocked. easily.
- Automatic cut-out is set to be too - Have the automatic cut-out facility checked by an expert
sensitive. (Section 9.3 / Level 2 / Menu 3+4).
Message 36 - Shorting plug removed, although a - Connect stop button or insert shorting plug (Section 6.6).
stop button is not connected.
- Closed circuit is interrupted.
Legend:
LED off
LED on
LED flashes slowly
LED pulses
LED flashes quickly
Factory default setting
Not possible –
11.1 Technical Data for Comfort 220.2, 250.2, 252.2, 250.2 speed
Electrical data Comfort 220.2 Comfort 250.2 Comfort 252.2 Comfort 250.2 speed
Nominal voltage *) V 230 / 260
Nominal frequency Hz 50 / 60
Power consumption A 1.1
Power input - operation KW 0.25
Power input - stand-by W 4.2 3.0 3.1 4.0
Operating mode (operating time) Min. KB 2 KB 5 KB 2
Control voltage V DC 24
Protection category, motor unit IP 20
Protection class II
*) subject to country-specific alternations
Mechanical data Comfort 220.2 Comfort 250.2 Comfort 252.2 Comfort 250.2 speed
Max. push and pull force N 600 800 1,000 800
Travel speed mm/sec. 140 220
Opening time (door specific) sec. 15 9.5
General data Comfort 220.2 Comfort 250.2 Comfort 252.2 Comfort 250.2 speed
Motor unit dimensions mm 220x125x395
Weight kg 3,8 4,1 4,2 4,5
Sound pressure level db (A) < 70
-20
Temperature range °C
+60
We hereby declare that in its design and construction, The machinery is incomplete and must not be put into
and in the form as delivered, the product mentioned service until the machinery into which it is to be
below complies with the relevant basic requirements of incorporated has been declared in conformity with the
the EC Machinery Directive (2006/42/EC). provisions of the Machinery Directive 2006/42/EC.
This declaration shall no longer be valid if changes are
made to the product without our authorisation. Scope of application of these installation instructions:
Production date 01.03.2012 - 31.03.2013
Product: Garage door operator
Comfort 220.2, 250.2, 252.2, 250.2 speed
Product:
Gate designation
Operator designation
Relevant EC directives:
– Construction Products Directive 89/106/EEC
– Machinery Directive 2006/42/EC
– Electromagnetic Compatibility 2004/108/EC
– Low Voltage Directive 2006/95/EC
Installer
Date / Signature