t2000 Catalogue English 11 10 17

The T2000 pressure transmitter uses a ceramic pressure sensor that is temperature compensated and calibrated for accuracy. It has a compact size that allows for easy installation in small spaces. The transmitter can measure pressure ranges from -1 to 600 bar with various output and electrical connection options. It has high accuracy, long term stability, and works in a temperature range of -40 to 100 degrees Celsius.

Uploaded by

Melyssa Motta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
521 views1 page

t2000 Catalogue English 11 10 17

The T2000 pressure transmitter uses a ceramic pressure sensor that is temperature compensated and calibrated for accuracy. It has a compact size that allows for easy installation in small spaces. The transmitter can measure pressure ranges from -1 to 600 bar with various output and electrical connection options. It has high accuracy, long term stability, and works in a temperature range of -40 to 100 degrees Celsius.

Uploaded by

Melyssa Motta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

T2000

Pressure transmitter

Dimension in:mm

The heart of T2000 pressure transmitter is a


c e r a m i c p r e s s u r e sensor that is temperature
compensated and laser trimmed for accurate span T2000 Order Ref NO
and offset calibration. The typical advantage is the
compact s i z e , which make it convenient to be T2000 – 4_20MA – 4 – B – 1.0 – DA – G
Installed in small room. A B C D E F

Output:4~20mA; 0.5~4.5V; 0~5V; 1~5V; 0~10V


B Measurement range
C Unit of measure: K=kPa; M=MPa; P=psi; B=bar 57
D Accuracy: 0.5=0.5%F.S; 1.0=1.0%F.S
E Electrical connector: P=Packard; D=Din43650C; DA=Din43650A; M12=M12X1; C=Cable; DT3P=DEUTSCH-3P
F Pressure connection: G=G1/4(O-ring); GA=G1/4; N=NPT1/4; 20=7/16-20UNF; M14=M14X1.5; G2=G1/2;
Specification
General Value
Measurement Range -1~0······100bar、0~2······3bar、0~4······60bar(normal range)、0~61······600bar
Overload Pressure 1.5 times of full scales
Burst Pressure 3 times of full scales
Accuracy ±0.5%F.S、±1.0%F.S
Long Term Stability Typical value:0.5%F.S Maximum:1%F.S
Working Temperature -40℃~100℃
Compensated Temperature -10℃~80℃
Storage Temperature -50℃~125℃
Medium Compatibility All corrosive medium compatible with 1Cr18Ni9Ti stainless steel and ceramic
Output Mode Two-wired Three-wired
Output 4~20mA 0.5~4.5V 0/1~5V 0~10V
Power Supply 10~30VDC 5VDC 10~30VDC/AC 12~30VDC/AC
Load Resistance (U-10)/0.02(Ω) >100K(Ω)
Insulation >100M(Ω)@50V
Electrical Connection Packard, DIN43650C,DIN72585,M12,Cable
Protection Grade IP67
Male G1/4,NPT1/4,7/16-20UNF,M20×1.5,G1/
Pressure Connection
(Female and other connection is available on request)
Response Time 10ms
Pressure Form Gauge pressure
Electromagnetic Compatibility Electromagnetic transmit:EN50081-1/-2;Electromagnetic sensitivity:EN50082-2

Conversion:1kgf/cm²=14.2psi 1bar=14.5psi