0% found this document useful (0 votes)
147 views4 pages

Na2Xfgby 2 X (10-300) MM 0.6/1 KV

This document provides specifications for an aluminum conductor, XLPE insulated, galvanized steel flat wire armor, PVC sheathed cable with a nominal cross sectional area between 10-300 mm2 and a voltage rating of 0.6/1 kV. It includes information on the cable construction, applications, electrical data, and standard packing. The cable is designed for installation underground, indoors, or outdoors and provides increased mechanical protection.

Uploaded by

Hajie Omen
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
147 views4 pages

Na2Xfgby 2 X (10-300) MM 0.6/1 KV

This document provides specifications for an aluminum conductor, XLPE insulated, galvanized steel flat wire armor, PVC sheathed cable with a nominal cross sectional area between 10-300 mm2 and a voltage rating of 0.6/1 kV. It includes information on the cable construction, applications, electrical data, and standard packing. The cable is designed for installation underground, indoors, or outdoors and provides increased mechanical protection.

Uploaded by

Hajie Omen
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

NA2XFGbY

NA2XFGbY 22xx(10-300)
(10-300) mm²
mm² 0.6/1
0.6/1 kV kV
Al / XLPE / SFWA / PVC
(Aluminium Conductor, XLPE Insulated, Galvanized Steel Flat Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-1

Construction Data
Application :
Nom. Overall Cable Aluminium Conductor
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical XLPE Insulation
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or PVC Inner Sheath
mm² mm kg/km operation.
Galvanized Steel Flat Wire Armor
10 18.8 662 Special Features on Request Galvanized Steel Tape
16 21.5 804 • Oil Resistance PVC Sheath
25 24.0 986 • UV Resistance
• Flame Retardant Cat. A, B, C
35 26.0 1,187
• Flame Retardant Non Category
50 29.5 1,375 • Anti Termite
70 33.5 1,711 • Anti Rodent
95 37.5 2,125 • Low Smoke Zero Halogen
120 41.0 2,489
150 44.0 2,876
185 50.5 3,552 Note :
240 55.0 4,263 Conductor Shape
300 60.5 5,106 10 - 16 sqmm supplied in non compacted circular stranded (rm) conductor shape
25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape

Standard Packing
10 - 150 sqmm supplied in wooden drum @ 1000 m
185 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%

Electrical Data
Conductor Inductance Current - Carrying Short
Capacity circuit current
Nom. DC AC
at 30°C * at
Cross Resistance Resistance 1 sec
Sect. at 20°C at 90°C in air in ground

Max. Max. Max. Max. Max.


(mm²) (Ω/km) (Ω/km) (mH/km) (A) (A) (kA)
10 3.08 3.949 0.248 70 77 0.94
16 1.91 2.449 0.236 95 102 1.50
25 1.20 1.539 0.242 123 130 2.35
35 0.868 1.113 0.234 151 157 3.29
50 0.641 0.822 0.232 184 186 4.70
70 0.443 0.568 0.229 232 229 6.58
95 0.320 0.411 0.224 284 274 8.93
120 0.253 0.325 0.223 329 312 11.28
150 0.206 0.265 0.225 371 347 14.10
185 0.164 0.211 0.225 432 394 17.39
240 0.125 0.162 0.223 509 457 22.56
300 0.100 0.130 0.222 583 515 28.20
26533-02 Rev. 2.0 / 2009

www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
NA2XFGbY
NA2XFGbY 33xx(10-300)
(10-300) mm²
mm² 0.6/1
0.6/1 kV kV
Al / XLPE / SFWA / PVC
(Aluminium Conductor, XLPE Insulated, Galvanized Steel Flat Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-1

Construction Data
Application :
Nom. Overall Cable Aluminium Conductor
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical XLPE Insulation
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or PVC Inner Sheath
mm² mm kg/km operation.
Galvanized Steel Flat Wire Armor
10 19.7 702 Special Features on Request Galvanized Steel Tape
16 22.5 887 • Oil Resistance PVC Sheath
• UV Resistance
25 25.0 1,093 • Flame Retardant Cat. A, B, C
35 27.5 1,318 • Flame Retardant Non Category
• Anti Termite
50 30.0 1,382
• Anti Rodent
70 34.5 1,770 • Low Smoke Zero Halogen
95 37.5 2,130
120 41.0 2,488
150 46.0 2,976 Note :
Conductor Shape
185 50.5 3,533
10 - 16 sqmm supplied in non compacted circular stranded (rm) conductor shape
240 56.0 4,327 25 - 35 sqmm supplied in compacted circular stranded (cm) conductor shape
300 61.0 5,127 50 - 300 sqmm supplied in sector shaped stranded (sm) conductor

Standard Packing
10 - 150 sqmm supplied in wooden drum @ 1000 m
185 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%

Electrical Data
Conductor Inductance Current - Carrying Short
Capacity circuit current
Nom. DC AC
at 30°C * at
Cross Resistance Resistance 1 sec
Sect. at 20°C at 90°C in air in ground

Max. Max. Max. Max. Max.


(mm²) (Ω/km) (Ω/km) (mH/km) (A) (A) (kA)
10 3.08 3.949 0.248 59 65 0.94
16 1.91 2.449 0.236 80 85 1.50
25 1.20 1.539 0.242 105 109 2.35
35 0.868 1.113 0.234 129 132 3.29
50 0.641 0.822 0.232 160 160 4.70
70 0.443 0.568 0.229 201 195 6.58
95 0.320 0.411 0.224 246 234 8.93
120 0.253 0.325 0.223 286 266 11.28
150 0.206 0.265 0.225 326 297 14.10
185 0.164 0.211 0.225 378 338 17.39
240 0.125 0.162 0.223 447 391 22.56
300 0.100 0.130 0.222 513 442 28.20
26533-03 Rev. 2.0 / 2009

www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
NA2XFGbY
NA2XFGbY 44xx(10-300)
(10-300) mm²
mm² 0.6/1
0.6/1 kV kV
Al / XLPE / SFWA / PVC
(Aluminium Conductor, XLPE Insulated, Galvanized Steel Flat Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-1

Construction Data
Application :
Nom. Overall Cable Aluminium Conductor
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical XLPE Insulation
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or PVC Inner Sheath
mm² mm kg/km operation.
Galvanized Steel Flat Wire Armor
10 21.5 797 Special Features on Request Galvanized Steel Tape
16 24.5 1,010 • Oil Resistance PVC Sheath
25 27.0 1,253 • UV Resistance
• Flame Retardant Cat. A, B, C
35 30.0 1,517
• Flame Retardant Non Category
50 34.0 1,678 • Anti Termite
70 38.5 2,142 • Anti Rodent
95 42.5 2,623 • Low Smoke Zero Halogen
120 47.5 3,169
150 53.5 3,767
185 57.5 4,421 Note :
240 64.5 5,471 Conductor Shape
300 70.0 6,483 10 - 16 sqmm supplied in non compacted circular stranded (rm) conductor shape
25 - 35 sqmm supplied in compacted circular stranded (cm) conductor shape
50 - 300 sqmm supplied in sector shaped stranded (sm) conductor

Standard Packing
10 - 120 sqmm supplied in wooden drum @ 1000 m
150 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%

Electrical Data
Conductor Inductance Current - Carrying Short
Capacity circuit current
Nom. DC AC
at 30°C * at
Cross Resistance Resistance 1 sec
Sect. at 20°C at 90°C in air in ground

Max. Max. Max. Max. Max.


(mm²) (Ω/km) (Ω/km) (mH/km) (A) (A) (kA)
10 3.08 3.949 0.248 65 71 0.94
16 1.91 2.449 0.236 88 92 1.50
25 1.20 1.539 0.242 117 119 2.35
35 0.868 1.113 0.234 144 143 3.29
50 0.641 0.822 0.232 169 164 4.70
70 0.443 0.568 0.229 211 200 6.58
95 0.320 0.411 0.224 259 240 8.93
120 0.253 0.325 0.223 301 272 11.28
150 0.206 0.265 0.225 350 307 14.10
185 0.164 0.211 0.225 400 347 17.39
240 0.125 0.162 0.223 474 402 22.56
300 0.100 0.130 0.222 544 454 28.20
26533-04 Rev. 2.0 / 2009

www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
NA2XFGbY
NA2XFGbY 55xx(10-50)
(10-50) mm²
mm² 0.6/1
0.6/1 kV kV
Al / XLPE / SFWA / PVC
(Aluminium Conductor, XLPE Insulated, Galvanized Steel Flat Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-1

Construction Data
Application : PVC Filler
Nom. Overall Cable
For installation in the ground, indoors, cable Aluminium Conductor
Cross Diameter Weight trunking and outdoors if increased mechanical
Section XLPE Insulation
protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or PVC Inner Sheath
mm² mm kg/km operation.
Galvanized Steel Flat Wire Armor
10 23.0 903 Special Features on Request Galvanized Steel Tape
• Oil Resistance
16 26.5 1,176 PVC Sheath
• UV Resistance
25 29.5 1,459 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
35 33.0 1,784 • Anti Termite
• Anti Rodent
50 37.5 2,189 • Low Smoke Zero Halogen

Note :
Conductor Shape
10 - 16 sqmm supplied in non compacted circular stranded (rm) conductor shape
25 - 50 sqmm supplied in compacted circular stranded (cm) conductor shape

Standard Packing
10 - 50 sqmm supplied in wooden drum @ 1000 m
Length Tolerance per drum ± 2%

Electrical Data
Conductor Inductance Current - Carrying Short
Capacity circuit current
Nom. DC AC
at 30°C * at
Cross Resistance Resistance 1 sec
Sect. at 20°C at 90°C in air in ground

Max. Max. Max. Max. Max.


(mm²) (Ω/km) (Ω/km) (mH/km) (A) (A) (kA)
10 3.08 3.949 0.248 68 72 0.94
16 1.91 2.449 0.236 91 94 1.50
25 1.20 1.539 0.242 121 121 2.35
35 0.868 1.113 0.234 149 145 3.29
50 0.641 0.822 0.232 181 171 4.70
26533-05 Rev. 2.0 / 2009

www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification