LEGEND
FCO FLOOR CLEAN OUT
KS KITCHEN SINK
AD AREA DRAIN
UR URINAL
OIL INTERCEPTOR
OIL INTERCEPTOR
A B C D E F G H I J K L
LAV LAVATORY
45000
5000 5000 4000 4000 4000 4000 3025 3975 4000 4000 4000
FROM EXISTING
BUILDING VS VENT STACK
WC WATER CLOSET
TO EXISTING
FD FLOOR DRAIN
ROAD DRAIN
GRATING
GRATING GRATING
SP SOIL PIPE (50/100mm dia. PVC)
1
VP VENT PIPE (50 mm dia. PVC)
4000
DP
GRATING
DRAIN PIPE (150 mm dia. PVC)
LAV LAV SOIL PIPE (150mm dia PVC PIPE)
WCO
2 WASTE PIPE (50mm dia PVC PIPE) FCO LAV WC SS SOIL STACK (50/100mm dia. PVC)
9500
LAV LAV FCO FCO FCO FCO FCO FCO
KS KS KS KS KS KS
3500
FD
UR UR UR SS SOIL STACK (110mm dia PVC PIPE)
FCO WASTE PIPE(50mm dia PVC PIPE) FCO
WASTE PIPE(50mm dia PVC PIPE) VS VS (75mm dia PVC PIPE) VS
KS KS KS WC KS KS KS
3 FCO
17000
2000
WASTE PIPE (75mm dia PVC PIPE)
FD
WC
LAV
4 FCO KS KS KS
WASTE PIPE (50mm dia PVC PIPE) VS VS
KS KS WASTE PIPE (50mm dia
KSPVC PIPE)
VS
SEPTIC TANK
GRATING
OVERFLOW
3500
KS KS KS KS KS KS TO EXISTING
FCO FCO FCO FCO FCO FCO
ROAD DRAIN
SS
5
4000
6 GRATING GRATING TO EXISTING
ROAD DRAIN
3025
1 FIRST FLOOR DRAINAGE SYSTEM
1:100 MTS
P-2
RECOMMENDING/APPROVAL APPROVED BY: PROJECT TITLE: PROJECT OWNER: REVISIONS: SHEET CONTENT: SHEET NO.
SANITARY ENGINEER
ENGR. JUAN P. RIALBUBIN JOSE C. TABANDA III SAN VICENTE FARMERS TRADING CENTER
MUNICIPAL ENGINEER MUNICIPAL MAYOR MUNICIPALITY OF SAN VICENTE, ILOCOS SUR
PRC NO.
DATE ISS.
PTR NO.
DATE ISS.
ECOLOGICAL AND TOURIST FRIENDLY MARKET AS SHOWN P-2
TIN NO. ADD. DESIGNED BY:
LOCATION: BRGY. POBLACION, SAN VICENTE, ILOCOS SUR ADDRESS: BRGY. POBLACION, SAN VICENTE, ILOCOS SUR