VCL-2750 PTP Slave Clock Overview

The VCL-2750 is a PTP slave clock that provides precise time and frequency synchronization across networks. It synchronizes to a PTP grandmaster and outputs 1PPS, IRIG-B, and NMEA time-of-day signals with nanosecond accuracy. Key features include an OCXO for holdover stability, management interfaces, and environmental ruggedness suitable for telecom and utility applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
88 views2 pages

VCL-2750 PTP Slave Clock Overview

The VCL-2750 is a PTP slave clock that provides precise time and frequency synchronization across networks. It synchronizes to a PTP grandmaster and outputs 1PPS, IRIG-B, and NMEA time-of-day signals with nanosecond accuracy. Key features include an OCXO for holdover stability, management interfaces, and environmental ruggedness suitable for telecom and utility applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

VALIANT

COMMUNICATIONS VCL-2750
IEEE-1588v2 PTP Slave
DIN Rail Version
Introduction: Application Diagram:
VCL-2750, PTP Slave Clock (DIN Rail Version) is a high
precision, high reliability time and frequency IEEE-1588v2 (PTP)
INPUT
synchronization solution which can be synchronized from
a IEEE-1588v2 PTP Grandmaster to provide frequency and Power
Supply
VCL-2750-PTP DIN Rail
time-of-day synchronization across a PTP network with 1588v2 SLAVE Version
(DC)
nanosecond accuracy. Multiple 1PPS / IRIG-B Outputs are
provided to synchronize local clock (time-of-day) to IEDs, OUTPUTS
4 x 1PPS / IRIG-B
as well as RTUs to a central timing source.
(4 BNC Outputs)
4 x NMEA 0183 ToD
(Time-of-Day) (4 RJ45 Outputs)

Additional Features:
! 1 x PTP Input (10/100BaseT Ethernet Slave Port)
! Password Protection
! 48V DC power supply
! 1 x OAM (10/100BaseT Ethernet Port)
! VLAN and Packet priority
! Supports QoS, 802.1p based packet priority.
The VCL-2750, PTP Slave Clock is specifically designed for
! Supports 802.1Q based VLANs.
providing synchronization in 2G/3G/4G, HetNet and LTE
! Power Contact and Lightening Protection as per
mobile telecommunications networks as well as in
Telcordia GR-1089-CORE.
backhaul wire-line TDM Networks. It may be also used by
Railways, Airports (including air-traffic control), Power
VCL-2750, PTP Slave Clock (DIN Rail Version)
generation and distribution companies and other Utility
companies who need to distribute highly precise time-of- Description: VCL-2750, PTP (IEEE-1588v2) Slave Clock -
day and frequencies locked to a PTP Grandmaster (GPS) synchronizes from PTP Grandmaster to provide 1PPS, IRIG-
Reference across multiple nodes of their networks. B and NMEA Outputs with high stability OCXO holdover.

The VCL-2750, PTP Slave Clock is equipped with a highly Typical Synchronization Applications
accurate, low-noise OCXO which provides a high stability
! Synchronizing mobile communication networks such
holdover that is typical of a Network SSU in the event of a
as UMTS, GPRS, HetNet, 2G, 3G, and 4G networks
failure of the transmission link.
! Wireless and Wireline Telecom synchronization
! Distributing Time (ToD) and Frequency reference for
Features and Highlights:
power utilities across all nodes of the network
! Reliable, Cost-Efficient Reference ! Synchronization of Defense Networks
! BMCA (Best Master Clock Algorithm) - allows the unit to ! Synchronizing airports and aviation communications
be installed in a redundant PTP Grandmaster network ! Synchronizing railway signaling networks and railway
! OCXO Holdover communications
! 1 PPS / IRIG-B outputs ! Synchronizing traffic management
! Nanosecond accuracy ! Broadcasting Network and Broadcast equipment
! Standard RJ45 and BNC connectors for all inputs and synchronization.
outputs
! ToD compliant to NMEA 0183 (RJ45 Port).

www.valiantcom.com 1
Valiant Communications Limited VCL-2750

Time Inputs: Environmental:


Input Type Connector Operational -20°C to +60°C (Typical: +25°C)
IEEE-1588v2 (PTP) RJ45 Cold Start -10°C to +60°C
Storage -40°C to +75°C
Standard Frequency and ToD Outputs: Humidity 95% non-condensing
Output Type Connector Cooling Convention Cooled
4 x 1 PPS or 4 x IRIG-B BNC No cooling fans are required.
Synchronized to PTP Grandmaster*
4 x TOD (Time-Of-Day) output RJ45 Mechanical Specifications:
compliant to NMEA0183 Height 73 mm.
*Note: User selectable between IRIG-B and 1PPS Depth 190 mm.
Outputs Width 190 mm.
Weight 1.0 kg.
Management and Monitoring Ports:
! USB Ordering Information
! 10/100BaseT Ethernet
VCL-2750 VCL-2750, PTP (IEEE-1588v2) Slave Clock
! 1 x External Alarm Relay Contact.
DIN Rail Mount,
- Synchronizes to PTP Grandmaster to
System Access, Control and Management Options:
provide 1PPS, NMEA, IRIG-B Outputs
! Telnet with high stability OCXO Holdover
! CLI Control Interface (HyperTerminal or VT100) - Management: SNMP, Telnet (RJ45 (F)
! SNMP V2 Traps (MIB File provided). Port), Serial Port (USB), EMS,
Graphical User Interface (GUI)
Security and Protection: - Installation Kit: System Core Cables,
Mounting Hardware, Documentation,
! Password Protection
User Manual
! Separate VLAN on monitoring and access.

Configuration and Monitoring Software:


! Telnet, CLI
! GUI (Graphical User Interface) - Runs on any PC
operating on Windows XP, Windows 7, Windows 8,
Windows 10 OS.

Revision 1.6 – September 14, 2018

U.K. U.S.A. INDIA

Valiant Communications (UK) Ltd Valcomm Technologies Inc. Valiant Communications Limited
Central House Rear Office 4000 Ponce de Leon, Suite 470 71/1, Shivaji Marg,
124 High Street, Hampton Hill, Coral Gables, FL 33146 New Delhi - 110015,
Middlesex, TW12 1NS, U.K. U.S.A. India

www.valiantcom.com 2

You might also like