B.O.Q.
OF
AUDITORIUM
FOR
PROPOSED NATIONAL LAW UNIVERSITY ORISSA
AT NARAJ, CUTTACK
CONSULTANT :
M/s. RATH ARCHITECTONIC
104, Madhusudan Nagar
Unit-IV, Bhubaneswar-751001
Ph. No. (0674) 2390940, 2395340
Page 1
ABSTRACT COST
1 CIVIL AND STEEL STRUCTURE WORKS Total:
2 P.H. WORKS Total:
3 KNX LIGHTING MANAGEMENT SYSTEM Total:
4 ELECTRICAL WORKS Total:
5 FIRE FIGHTING WORKS Total:
For M/s. RATH ARCHITECTONIC.
Page 2
B.O.Q. OF AUDITORIUM BUILDING
FOR PROPOSED NATIONAL LAW UNIVERSITY ORISSA AT NARAJ, CUTTACK
CIVIL WORKS
Sl.No. Description Unit Qty. Rate Amount
1 Excavation of foundation trenches and column foundation
and pits in all kinds of soil within an initial lead and lift of 1.5
mtrs. depth including dressing the sides and leveling the bed
and depositing the excavated material away from the site
within an initial lead of 50 mtrs including cost of all labour,
sundries, tools and plant etc., complete as per the direction
of the Engineer-in-charge. Cum. 1500.00
Rate in figure
Rate in word
2 Filling foundation trenches and plinths with excavated
materials in layers not exceeding 0.3 mtr in depth including
watering and ramming and dressing and levelling the top
proper level or gradient, including cost of all labour,
sundries, tools and plants, etc. complete as per the direction
of the Engineer-in-charge. Cum. 500.00
Rate in figure
Rate in word
3 Filling foundation trenches and plinths with sand, well
watered, compacted, dressed and leveled to proper gradient
including cost of all materials, labour, conveyance, loading
and unloading, taxes, royalities, sundries, tools and plants,
etc., complete as per the direction of the Engineer-in-
charge. Cum. 900
Rate in figure
Rate in word
4 Earth Filling:- Filling of earth, (available within the plot)
behind retaining wall area etc. in specified layers not
exceeding 300mm thick including breaking clods, watering,
compacting each layers with vibratory compactor and at
unaccesible places with wooden / steel rammers to achieve
90 to 95% proctor density at optimum moisture content, all
leads and lifts cost includes conveyance of all materials
labour, machinery etc. Cum 723
Rate in figure
Rate in word
5 Earth Filling:- Filling with approved quality of earth brought
from outside, in specified layers not exceeding 300mm thick
including breaking clods, dewatering, watering, compacting
each layers with vibratory compactor and at unaccesible
places with wooden / steel rammers to achieve 90 to 95%
proctor density at optimum moisture content, all leads and
lifts cost includes conveyance of all materials labour,
machinery etc. Cum 316
Rate in figure
Rate in word
Page 3
Sl.No. Description Unit Qty. Rate Amount
6 Rubble Soling:- Providing and laying rubble soling 200mm
thick ( in specific areas as instructed by EIC) with approved
quality rubble, average size 150 mm to 180 mm in size
including dewatering, hand packing of smaller size stones
and compaction the rubble layers etc. complete Sqm. 200
Rate in figure
Rate in word
7 ANTI-TERMITE TREATMENT :
(i) Providing pre construction anti-termite treatment with
chemical emulsion Chloropyrifos EC 20% with 1%
concentration. Sqm. 2490
Rate in figure
Rate in word
The chemical emulsion shall be in required dosage on entire
area of ground and wall trenches as follow.
(a) Bottom surface, sides of foundation trenches, column pits
and basement. At the rate of 5 litres per sqm. of surface
(b) After the foundation for the walls, columns, piers and
retaining walls of the basement come up treat the back fill
earth in immediate contact with face side of the foundation.
At the rate of 7.5 litres per sqm. of vertical surface of
foundation.
(c) Prior to laying the sand bed or subgrade for the ground floor
of the building, to surface of consolidated earth filling with in
the plinth walls should be levelled and treated. At the rate of
5 litres per sqm. of surface area.
(d) Junctions of wall and floor shall be treated by making 30 mm
wide 30 mm deep channels at the junction. Holes are made
in the channel at 150 mm apart up to ground level with crow
bar then chemical emulsion is poured. At the rate of 7.5
litres per sqm. of vertical wall or column surface.
(e) External periphery shall be treataed by making 300 mm
deep holes at 150 mm centre and filled with chemicals. At
the rate of 7.5 litres per sqm.
(ii) Treatment at points of contact of wood work by chemical
emulsion Chlorpyriphos emulsifiable concentrate of 20% /
Lindane (in oil or kerosene based soulution) @ 0.5 litres per
hole by drilling 6 mm dia holes at downward angle of 45
degree at 150 mm centre to centre and sealing the same. Mtr. 398.5
Rate in figure
Rate in word
Page 4
Sl.No. Description Unit Qty. Rate Amount
8 PCC:- Providing and laying (M20) PCC of 150mm thick with
necessary side shuttering, compaction, curing, vibrations
and dewatering (minimum cementitious content shall be as
specified in the IS Code) below raft slab /raft beams/ column
footings/ Retaining wall/at ground level etc complete.
Cum. 187
Rate in figure
Rate in word
9 Providing and laying plain cement concrete (1:2:4) in
foundation and bottom layers of flooring using 25 mm size
black hard crusher broken granite metal of approved quality
from approved quarry including mixing, lowering, laying and
compacting to proper thickness, watering and curing for the
required period, including cost of all material, labour,
conveyance, loading and unloading, taxes, royalties,
scaffolding, sundries, tools & plants, etc., complete as per
the direction of Engineer-in-charge. Cum. 54
Rate in figure
Rate in word
10 Providing ready mix concrete of M30 grade & construction of
RCC pile Cap, RCC Tie Beams at Pile cap level as shown
in the structural drawing, using river sand, 20mm & down
size coarse aggregate. Scope includes breaking of concrete
and cutting of piles up to required level including, watering
and curing the required period, including cost of all
materials, labour, conveyance, loading and unloading,
royalties, sundries, tools and plants, etc complete as per
direction of the Engineer-in-charge. Cum. 1250.00
Rate in figure
Rate in word
11 The rate for RCC work shall include for forming projections,
sinking, of floors in toilets wherever directed, forming
opening or niches, providing dowel bars and also co-
ordinating with other agencies for laying conduits, boxes,
pipes, clamps etc. as directed at site. The rates quoted shall
include forming construction joints / expansion strips as
directed by the Consultant.
Formwork( for unfinished concrete surface )rate shall be
inclusive & shallt be not paid separately unless otherwise
specified.Formwork shall be waterprooof shuttering plywood
with minimum thickness not less than 12mm. Formwork
shall include shuttering, centering, propring,wedging
etc.removing the same after specified period without
damaging the concrete works. Formwork( for form-finished
concrete exposed surface )rate shall be exclusive & shallt
be paid separately unless otherwise specified.
Reinforcing steel shall be paid seperately unless otherwise
specified.
No finishing items are to be considered in quoting the rates
of RCC items unless otherwise specified.
Page 5
Sl.No. Description Unit Qty. Rate Amount
After concreting the concrete shall be covered with hessian
cloth for overnight before ponding is done for curing of
slabs.
Ready mix concrete of M30 grade with minimum
cementitious content shall be as specified in the I.S Code.
(i) R.C.C Column / pedestal Cum. 128
Rate in figure
Rate in word
(ii) RCC staircases Cum. 200.00
Rate in figure
Rate in word
12 Providing & laying 40 mm thick damp-proof course to all
masonry works as per specifications in 1:2:4 with 12.5 mm
and downsized aggregates the DPC shall be laid in two
layers of 20 mm thick each etc. complete as per
specification, drawings and as directed by Engineer-in-
charge. Sqm. 8
Rate in figure
Rate in word
13 PILE WORK
(a) Installation of RCC cast in situ Piles in M30 Grade
Concrete as shown in the structural drawings using rotary
drilling rigs.Scope includes drilling through all type of strata
& through the adjacent piles and concreting upto the cutoff
level as shown in drawings
(i) 600 mm dia. Piles Mtr. 2500
Rate in figure
Rate in word
(ii) 1000 mm dia. Piles Mtr. 2200
Rate in figure
Rate in word
14 Vertical load (downward/uplift) and lateral load testing of
piles in accordance with IS 2911 (Part IV) including
installation of loading platform and preparation of pile head
or construction of test cap and dismantling of test cap after
test etc. complete as per specification and the direction of
Engineer-in-charge.
Single pile upto 50 tonne capacity
Initial test Per test 1
Rate in figure
Rate in word
15 Vertical load (downward/uplift) and lateral load testing of
piles in accordance with IS 2911 (Part IV) including
installation of loading platform and preparation of pile head
or construction of test cap and dismantling of test cap after
test etc. complete as per specification and the direction of
Engineer-in-charge.
Single pile upto 50 tonne capacity
Page 6
Sl.No. Description Unit Qty. Rate Amount
Routine test Per test 1
Rate in figure
Rate in word
16 Providing prescast RCC Jali, 50 mm thick, fixing in position
with Cement mortar 1:3 as per required design and pattern.
The rate includes cost of all materials, labour, conveyance,
loading and unloading, royalties, sundries, tools and plants,
scaffolding, curing etc., complete as per direction of the
Engineer-in-charge. Sqm. 3
Rate in figure
Rate in word
17 Providing & placing in position RCC Precast slabs, thickness
upto 75 mm, in CC 1:2:4 with 12 to 6 mm graded trap
aggregate including finishing the top surface smooth with
trowel, and providing lifting hooks or notches as required. Sqm. 68
Rate in figure
Rate in word
18 Providing RCC Racks / selves, counter slabs, benches
thickness upto 75 mm, having full bearing on wall and
projection upto 600 mm in CC 1:2:4 with 12 to 6 mm graded
trap aggregate. The top surface and exposed edges shall be
finished with neat cement punning over 12 mm thick cement
plaster 1:6. Sqm. 35
Rate in figure
Rate in word
19 Providing and fixing Light duty Ductile iron grating of size450
mm wide x 600 mm with Frame(hinged) of approved design
including setting floor with cement mortar length for trench
drain etc., complete as per direction of the Engineer-in-
charge. Nos 40
Rate in figure
Rate in word
20 Providing and fixing Light duty Ductile iron grating of size
450 mm x 450 mm with Frame(hinged) of approved design
including setting floor with cement mortar etc., complete as
per direction of the Engineer-in-charge. Nos 60
Rate in figure
Rate in word
21 Providing and fixing Light duty Square Cover of size 600 mm
x 600 mm with frame(hinged) of approved design including
setting floor with cement mortar etc., complete as per
direction of the Engineer-in-charge. Nos 30
Rate in figure
Rate in word
Page 7
Sl.No. Description Unit Qty. Rate Amount
22(a) Providing, laying & binding of M.S. round / deformed / tor
steel reinforcement bars of required diameters for
straightening, cutting to size, bending, and binding the grills,
lifting and placing in position at all heights & locations as per
design complete including cost of bars, cost of binding wires
22 gauge, labour, conveyance, loading and unloading,
taxes, royalties, sundries, tools and plants upto floor five
level, etc. complete as per the direction of the Engineer-in-
charge. (linear measurement will be taken and quantity will
be calculated on standard weight of bars for all heights). Qntl. 2950
Rate in figure
Rate in word
(b) Extra over item 22 with rust Converter coating
Tor steel Fe 500 with rust convertor Qntl. 216
Rate in figure
Rate in word
23 STRUCTURAL STEEL WORKS
Providing, fabricating and erecting in position Structural steel
work for girders , beams, trusses , portals, columns, stairs,
runners, purlins, bracings, using the rolled steel structural
members conforming to grade 355 (Yield Strength in
N/mm2) of approved make (conforming to BS EN 100025)
in rolled sections such as universal beams, universal
columns, channels etc, and in built-up sections including
straightening, welding , insert plates and angles with hold
fasts etc., of all sizes and shapes and as per detail design,
drawings and specifications for various spans, fillet welding,
butt welding as specified in drawings, butt weld splicing,
necessary edge preparation for butt welding, etc., all as per
specifications and drawings. The weight of bolts and nuts
will be paid separately. The rate includes necessary
machining/grinding/smoothening of members and all weld
joints before grid/shot blasting to give a neat and clean
appearance.
Page 8
Sl.No. Description Unit Qty. Rate Amount
The rate also includes the erection machinery/equipment,
temporary supporting structures and members required for
erection etc complete. The rate shall include preparation of
detail shop drawings on 3D Software TEKLA Structures (X-
steel) & Revit .Fabrication can only be taken after approval
of shop drawings by Consultant. The contactor shall prepare
the design calculation and fabrication shop drawings, based
on the forces given on the drawings for all the connections /
splices, discussing with Architects regarding aesthetics.
These shall be approved by the structural consultant before
proceeding further. Contactor has also to submitt a
complete erection methology of the buiding considering the
stability during erection. Structure will be covered with
fabric/cloth during monsoon/high sunny days,
provision/system to incorporate same to be included in cost.
Provision of the covering to be approved by Structural
engineer in Charge. Qntl. 18500
Rate in figure
Rate in word
24 Providing fabricating and fixing for all connections of steel
members MS galvanized bolts, nuts washers, etc of grade
8.8, of any diameter between M-16 to M39 as per IS:1367. Qntl. 2000
Rate in figure
Rate in word
25 Providing fabricating and erecting foundation/top bolts, nuts
and washers etc of grade 8.8 of any diameter from M20 to
M56, for steel columns trusses, etc including providing the
necessary threading length, fillet welding of plate washer at
bottom, fixing in position precisely in RCC pedestal using
steel template etc complete as per drawings & specifications
and as per direction of the Engineer-in-charge. Qntl. 2000
Rate in figure
Rate in word
26 Providing and fixing as per manufactures specifications ,
metal decking (ComFlor or equivalent) 60mm deep with
0.9mm total thickness. Zinc coated steel to EN 10346:2009
(European Standard) or AS1397:2001 (Australia standard)
or equivalent approved by structural engineer with a
guaranteed minimum yield stress of as mentioned in table
below. Minimum zinc coating mass is 275g/m² total including
both sides. The rate to include all the flashings/ end trims /
fixing bolts etc complete. To be approved by structural
engineer and as per direction of the Engineer-in-charge. Sqm. 4616
Rate in figure
Rate in word
27 Providing and fixing Roof Sheeting : Top (Standing Seam)
and Bottom sheet. To be approved by structural engineer.
Page 9
Sl.No. Description Unit Qty. Rate Amount
Supply & Installation of Double skin insulated roof system
comprising of Outer sheet manufactured out of 0.70mm
Standing Seam roof system profiled sheeting (single length,
on site forming) having maximum pitch and crest depth as
specified in specifications or as per structural consultant
design requirement. The feed material is to be
manufactured out of Color Coated Galvalume high tensile,
yield strength as per specifications or as per design
requirement of structural consultant, with zinc-aluminium
alloy of AZ-150 (as per AS 1397:1993). The sheet shall have
a hot dip metallic zinc-aluminium alloy coating of zinc (45%)
& aluminium (55%) with total mass coating of 150gsm/sqm
on both sides.
The profile should have anti capillary groove along with the
length. Complete in all respects including all accessories as
per specifications in single length. Installation to be done
using concealed clip system & no penetration of screws
from the top (screw less system).The pan shall be stiffened
by using small ribs. The inner sheets manufactured out of
0.70mm (TCT) (Total Coated Thickness) Bare Galvalume
Sheet. The sheet will have yield strength as per structural
design requirement or a specified in specifications.
The roof elements will be supported by and joined
longitudinally with an electrically operated closure machine
over concealed extruded clips integrated into the longitudinal
element flange thereby allowing for the possibility of
transmitting reaction forces resulting from positive and/or
negative loads and also accommodating unobstructed
thermal movements resulting from the specified ambient
temperature range.. In similar dimensions/size and fixed to
structure by means of corrosion protected self tapping
fasteners. The sub girts of size 50x50x50mm manufactured
out of 1.6mm G.I. Z shape would be fixed to inner sheeting
on face side to purlin locations by means of Galvanized
coated self tapping fasteners (12-14x55) thru the crust An
insulation of 50mm thick Glass wool Insulation of 48
Kg./cum density shall be fixed in between two sheets. The
sheets shall be in custom lengths.
Flashing:
Supply of Flashings fabricated out of plain sheet with Pre-
painted Galvalume (PPGL) Steel Sheet in0.70mm (TCT)
thickness out of plain sheet upto :
0 - 600 mm Girth
601 - 1220 mm Girth etc. complete and as per direction of
the Engineer-in-charge. Sqm. 3500
Page 10
Sl.No. Description Unit Qty. Rate Amount
28 Providing strong, rigid, leveled, and plumbed centering and
shuttering to required shape and size, with shuttering ply or
steel centering materials with all necessary bracing and tiles
and supports with leveling centering covered with
bituminous paper with provisions necessary holes and
pockets for electrical conduits, pipes, P.H. pipes, for hooks
or boxes, switch and board insert plates, clamps and
extension bars etc., including dismantling the same after the
required intervals from the date of casting including cost of
all materials, labour, conveyance, loading and unloading,
taxes, royalties, scaffolding, sundries, tools and plants, etc.,
complete as per the direction of the Engineer-in-charge.
(a) Foundations, footings, bases of columns etc. for mass
concrete. Sqm. 900
Rate in figure
Rate in word
(b) Suspended floors, roofs, landings, balconies and access
platform. Sqm. 102
Rate in figure
Rate in word
(c) Columns, beams, plinth beams, girders, bressumers and
cantilevers, staircase, horizontal and vertical fins, bands,
coping, moulding, cornice etc. Sqm. 700
Rate in figure
Rate in word
(d) Lintels Sqm. 120
Rate in figure
Rate in word
(e) R.C.C. wall & fins Sqm. 100
Rate in figure
Rate in word
29 K.B. brick masonry work using (250 mm x 120 mm x 80
mm) with tolerance of size K.B. bricks having crushing
strength not less than 75 kg / sqcm, mix (1 cement : 6
sands) in 250 mm thick wall, immersing the bricks for
minimum 6 hrs in water before use, with all necessary
projection, splay cutting, circular moulding, corbelling, etc.,
including cost of all materials, labour, conveyance, loading,
and unloading, taxes, royalties, scaffolding, watering, curing,
sundries, tools and plants etc., as per the direction of the
Engineer-in-charge in foundation & plinth Cum. 150
Rate in figure
Rate in word
Page 11
Sl.No. Description Unit Qty. Rate Amount
30 K.B. brick masonry work using (250 mm x 120 mm x 80
mm) with tolerance of size K.B. bricks having crushing
strength not less than 75 kg / sqcm, mix (1 cement : 6
sands) in 250 mm thick wall, immersing the bricks for
minimum 6 hrs in water before use, with all necessary
projection, splay cutting, circular moulding, corbelling, etc.,
including cost of all materials, labour, conveyance, loading
and unloading, taxes, royalties, scaffolding, watering, curing,
sundries, tools and plants etc. upto floor five level, as per
the direction of the Engineer-in-charge in superstructure. Cum. 895
Rate in figure
Rate in word
31 HALF BRICK MASONRY
(a) Half brick masonry with bricks of (75 Kg. / sqcm) class
above plinth level upto floor level with cement mortar (1:4). Sqm. 1100
Rate in figure
Rate in word
(b) Extra for providing and placing in position 2 Nos. 6 mm dia
M.S. bar at every 3rd course of half brick masonry. Sqm. 1200
Rate in figure
Rate in word
32 Providing average 25 mm thick grading plaster with mix
1:2:4 (1 cement : 2 sand : 4 bazuri) of cement mortar using
2% water proofing compound (of cement) of approved make
and quality on top of roof terrace of all floors including
scrapping and cleaning the roof plastering and finishing
smooth to proper slope and gradient, including cost of all
materials, labour, conveyance, loading and unloading, taxes,
royalties, scaffolding, watering. Sqm. 120
Rate in figure
Rate in word
33 Providing gola 75 mm x 75 mm in cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 stone aggregate 10 mm and
down gauge) including finishing with cement mortar 1:3 (1
cement : 3 fine sand) all complete as per direction of
Engineer-in-charge.
In 75 mm x 75 mm deep chase. Mtr. 210.28
Rate in figure
Rate in word
Page 12
Sl.No. Description Unit Qty. Rate Amount
34 Providing Avg. 12 mm thick cement plaster 1:6 (1 cement : 6
sand) to inside surface of masonry, column, beams and
chajjas, racking out joints, scrapping and cleaning the
surface and finishing the plastered surface smooth to proper
plumbs and levels and providing grooves as shown in the
drawing or as directed including cost of all materials, labour,
conveyance, loading and unloading., taxes, royalties,
scaffolding, watering, curing, sundries, tools and plants, etc.,
as per the direction of the Engineer-in-charge. Sqm. 10858
Rate in figure
Rate in word
35 Providing Avg. 16 mm thick cement plaster 1:6 (1 cement : 6
sand) to outside surface of masonry, column, beams and
chajjas, racking out joints, scrapping and cleaning the
surface and finishing the plastered surface smooth to proper
plumbs and levels and providing grooves as shown in the
drawing or as directed including cost of all materials, labour,
conveyance, loading and unloading., taxes, royalties,
scaffolding, watering, curing, sundries, tools and plants, etc.,
as per the direction of the Engineer-in-charge. Sqm. 3120
Rate in figure
Rate in word
36 Providing average 6 mm thick cement plaster under ceiling,
chajja and beam proportion 1:4 cement mortar including
chipping slurring etc. complete.as per the direction of the
Engineer-in-charge. Sqm. 300
Rate in figure
Rate in word
37 Providing & applying cement punning over cement plaster
as per the direction of the Engineer-in-charge. Sqm. 60
Rate in figure
Rate in word
38 Making raised band upto 600 mm wide and 12 mm
projection from the plastered surface in cement plaster 1 : 3,
over masonry or concrete surface. Mtr 30
Rate in figure
Rate in word
39 Forming groove of uniform size from 12 mm x 12 mm and
upto 25 mm x 15 mm in plastered surface as per approved
pattern using wooden battens, nailed to the under layer
including removal of wooden battens, repairs to the edges of
plaster panel and finishing the groove complete as per
specifications and direction of the Engineer-in-Charge. Mtr. 35
Rate in figure
Rate in word
Page 13
Sl.No. Description Unit Qty. Rate Amount
40 Extra for supplying and applying concrete bonding agent
compound for obtaining proper bonding between old
concrete and new concrete. The bonding agent compound
shall be of approved make as directed by Engineer-in-
charge which shall be applied as per manufacturer's
specification and the quantity shall be measured in liters. Lit. 800
Rate in figure
Rate in word
41 Extra for supplying and mixing approved quality concrete
admixture as per manufacturer's specification in all kind of
concrete work at any location of approved make. The
admixture shall be based on the design mix which shall be
carried out by the contractor prior to start of work. Lit. 3300.00
Rate in figure
Rate in word
42 Providing and fixing circular / hexagonal M.S. sheet ceiling
fan box 73 mm height make out of 1.5 mm thick M.S. sheet
welded with 12 mm dia M.S. bar bent to shape with
provision of conduit inlet all complete as per direction of
Engineer-in-charge.
The box shall be finished with two coats of anticorosive
paints. Nos. 100
Rate in figure
Rate in word
43 Providing and applying 2 coats acrylic based weather coat
paint (exterior quality) of approved make, which includes
two coat of exterior putty over a coat of primer of approved
brand & shade over the surfaces including preparation of
surface, with cost of all materials, labour, conveyance,
taxes, royalties, scaffolding, watering, curing, sundries, tools
and plants, etc., as per the direction of the Engineer-in-
charge. Sqm. 2500
Rate in figure
Rate in word
44 INSIDE WALL PAINTING :
(a) Supplying and painting of internal walls and ceiling with two
or more coats of acrylic emulsion paint of approved make,
which includes two coat of internal putty with a coat of
primer all complete. The shade and brand to be approved by
NLUO/ Architect before execution of paint work.
Sqm. 8500
Rate in figure
Rate in word
(b) Supplying and painting of enamel paint with two or more
coats of approved make on the surface to be finished with
required thickness internal putty which includes one coat of
primer of approved brand all complete. The shade and
brand/make to be approved by NLUO/ Architect before
execution of painting work. Sqm. 120
Page 14
Sl.No. Description Unit Qty. Rate Amount
Rate in figure
Rate in word
45 STRUCTURAL STEEL WORKS:
Providing & Painting of steel work as per the following
specifications & systems:
All steel surfaces shall be abrasive blast cleaned to Sa
2.5(ISO8501-1:1988) or SSPC- SP6, using a blend of shot
and grit. If oxidation has occurred between blasting and
paint application, the surface should be reblasted to the
specified visual standard. Any surface defects revealed by
the blast cleaning process should be filled/ ground or treated
suitably. Surface profile of 40-50 microns (1.5-2 mils) is
recommended. Before blasting, surfaces shall be washed
and cleaned by waterjet / Solvent to remove surface
contamination/ grease etc. The painting work shall be
carried out by applicator, approved by manufacturer. Also
manufacturer shall depute their technical representative to
inspect and certify the workmanship & quality of the work at
every stage. Contractor shall submit guarantee on Rs.100
Stamp Paper from manufacturer for the executed work for
the specified period, against deterioration, loss of gloss,
colour, retention etc., as per approved format
a) Painting system for steel structures to be with anti corrosive
primer and PU paints with mat finish. Shade to be finalized
by architect's.
i) Anti corrosive primer should be 99% zinc rich (Cold
galvanized 80m by Zinga or as approved by structural
engineer on submission of specifications)
ii) A two component acrylic polyurethane finish, giving
excellent durability and long term recoatability, having VS
57%, and applied to DFT 50m (TSR = 11.4 m2/ litre). This
coating shall be applied in shop or site by airless spray/
brush application. ( Interthane 990 of International
Protective Coating or equivalent as per approval of structural
engineer on submission of specifications) etc. complete and
as per the direction of Engineer-in-charge. Qntl. 18500
Rate in figure
Rate in word
46 SALWOOD CHOWKATH :
Supplying and fixing Sal wood in Single rebate frames of
doors, and other frames, wrought framed of 125 mm x 62
mm size including all fittings and fixed in position with
anchor fastener 3 nos. on each side including S.S screw on
wooden joinery, grooves and making arrangement as shown
on drawing, applying anti-termite paint on surfaces touching
masonry or concrete etc. complete and as per the direction
of Engineer-in-charge. Cum 0.521
Rate in figure
Rate in word
47 UPVC WINDOW:
Page 15
Sl.No. Description Unit Qty. Rate Amount
a Providing and fixing of factory made 67 series uPVC 2-track
Sliding window (White Colour) complete, comprising uPVC
multi-chambered frame of size 67mm x 54mm having uPVC
roller track on top and uPVC sash of size 60mm x 47mm.
All corners of frame and sash will be fusion welded and duly
reinforced with G.I. section 1.2 mm.
After placing 4mm float or prescribed glass in the sash,
uPVC glazing bead, interlock, EPDM gasket, brush will be
provided including hardware, i.e., touch lock and rollers &
proper drainage system shall be provided. Window will be
fixed to the wall with 100mm long and 8mm dia. Fasteners
and complete in all respect as per direction of Engineer-In-
Charge. Sqm. 43
Rate in figure
Rate in word
b UPVC Adjustable Louver Window with Exhaust
Provision
Providing and fixing of factory made approved make, uPVC
Louver window comprising of uPVC multi-chambered frame
of size 67 mm x 54 mm, duly reinforced with 1.2 mm thick
G. I. Section. Both vertical sides of the frame, adjustable
louver with 4 mm frosted glass and having one lever to
adjust the glass. Window will be fixed to the wall with
100mm long and 8mm dia. Fasteners and complete in all
respect as per direction of Engineer-In-Charge. Sqm. 26
Rate in figure
Rate in word
48 Supplying, fabricating and fixing MS grills madeup with M.S.
square bar / round bar / flat as per design and drawing
including applying two coat enamel paint over a coat of red
oxide primer and fixing the same to wooden dor and window
frames as per requirement and direction of Engineer-in-
charge. Qntl. 10.75
Rate in figure
Rate in word
49 STAINLESS STEEL STAIRCASE RAILING WITH HANDLE
:
Supplying, Fitting and fixing of stainless steel of 304 grade in
hand railing using 50mm dia of 2mm thick circular pipe with
Balustrade of size 32mmx32mmx2mm @ 0.90mtr C/C and
stainless square pipe bracing of size 32mmx32mmx2mm in
3 rows in stair case as per approved design and
specification buffing polishing etc with cost conveyance
taxes of all materials labour T&P etc required for the
complete in all respect. Rmt. 45
Rate in figure
Rate in word
50 PLINTH PROTECTION WORK :
Page 16
Sl.No. Description Unit Qty. Rate Amount
Making plinth protection 50 mm thick of cement concrete
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate
20 mm nominal size) over 75 mm bed of dry brick ballast 40
mm nominal size well rammed and consolidated and
grouted with fine sand including finishing the top smooth. Sqm. 162
Rate in figure
Rate in word
51 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand :
4 graded stone aggregate) finished with a floating coat of
neat cement including cement slurry, but excluding the coat
of nosing of steps etc. complete.
40 mm thick with 20 mm nominal size stone aggregate. Sqm. 55
Rate in figure
Rate in word
52 VITRIFIED FLOOR TILES :
(a) Supplying, fitting and fixing nano polished double charged
vitrified tile in floors of size 600 mm x 600 mm of approved
make with application of polymer modified cement based
water resistant adhesive bed of required thickness of 10 mm
and filling joints with epoxy grout of approved quality
including cost of all materials, labour, T&P etc. required for
the work Basic Price - Rs.140.00 to Rs.160.00 / Sft.. Sqm. 1500
Rate in figure
Rate in word
53 CERAMIC GLAZED TILE :
Providing and fixing 1st quality ceramic glazed wall tiles in
kitchen walls and as specified in drawing of approved make
of 5mm and size 450 mm X 300 conforming to IS : 15622
(thickness to be specified by the manufacturer), of approved
make, in all colours,shades except burgundy, bottle green,
black of any size as approved by Engineer-in-Charge, in
skirting, risers of steps and dados, over 12 mm thick bed of
cement mortar 1:3 (1 cement : 3 coarse sand) and jointing
with grey cement slurry @ 3.3 kg per sqm,including pointing
in white cement mixed with pigment of matching shade
complete as per the direction of the Engineer-in-charge.
Basic Price - Rs.70.00 to Rs.80.00 / Sft. Sqm. 119
Rate in figure
Rate in word
54 MARBLE STONE PARTITION :
Providing, fitting and fixing of white marble stone partition
with 16 mm thick marble stone (sample of marble shall be
approved by Engineer-in-charge) with size of marble 450
mm x 900 mm (minimum) in urinal partition etc. all complete
and as per direction of Engineer-in-charge. Sqm. 12
Rate in figure
Rate in word
Page 17
Sl.No. Description Unit Qty. Rate Amount
55 GRANITE CLADDING :
Providing 20 / 18 mm thick approved quality & shade
polished granite slabs, and cutting to required size laid over
20 mm thick under layer of cement mortar (1:3) to masonry
or concrete surfaces in skirting, dado, risers and treads of
steps, counters, edtges / facias complete (screwing on
vertical surfaces if requied) to proper level and joints filled
with cement mixed with oxide matching colour in requied
proportion, washed, acid cleaned, including cost of all
materials, labour, conveyance, taxes, royalties, scafflding,
watering, curing, sundries, tools and plants, etc., complete
as per the direction of the Engineer-in-charge. Basic Price - -
Rs.310.00 to Rs.400.00 / Sft. Sqm. 650
Rate in figure
Rate in word
56 GRANITE FLOORING :
(a) Providing and fixing 18 mm thick gang saw cut, mirror
polished, premoulded and prepolished, machine cut for toilet
walls and as specified in drawing, of required size,approved
shade, colour and texture laid over 20 mm thick base
cement mortar 1:4 (1 cement : 4 coarse sand), joints treated
with white cement, mixed with matching pigment, epoxy
touch ups,including rubbing, curing, moulding and polishing
to edges to give high gloss finish etc. complete at all
levels.as per the direction of the Engineer-in-charge. Basic
Price - Rs.310.00 to Rs.400.00 / Sft. Sqm. 1450
Rate in figure
Rate in word
(b) Providing and fixing leather finish granites of approved make
and shade in specified areas for flooring and 17 mm
thickness fixed over a base of 25 mm thick 1:3 cement sand
mortar and the granite slab shall be fixed with help of 1:1
cement slurry and the granite joints shall be finished with
white cement with matching oxide pigments. The final
surface shall be made ready to use after cleaning and
washing the surface properly with clean cloths etc.,
complete as per the direction of the Engineer-in-charge.
Basic Price - Rs.310.00 to Rs.400.00 / Sft. Sqm. 310
Rate in figure
Rate in word
Page 18
Sl.No. Description Unit Qty. Rate Amount
(c) Providing and laying flamed finish Granite stone flooring in
required design and patterns, in linear as well as curvilinear
portions of the building all complete as per the architectural
drawings with 18 mm thick stone slab over 20 mm (average)
thick base of cement mortar 1:4 (1 cement : 4 coarse sand)
laid and jointed with cement slurry and pointing with white
cement slurry admixed with pigment of matching shade
including rubbing , curing and polishing etc. all complete as
specified and as directed by the Engineer-in-Charge : a.
Flamed finish granite stone slab Jet Black, Cherry Red, Elite
Brown, Cat Eye or equivalent Basic Price - Rs.300.00 to Rs
350.00 / Sft. Sqm. 300.00
Rate in figure
Rate in word
57 Providing, fitting and fixing of approved coloured granite
stone on counter top wash basin over a base of cement
concrete (1:2:4) fixed by fine cement slurry. The edge of the
counter top wash basin shall be of double moulded with
fixing of extra marble piece for double moulding etc. all
complete. Sqm. 40
Rate in figure
Rate in word
58 Providing, fitting and fixing of Black granite stone on Kitchen
counter slab over a base of cement concrete (1:2:4) fixed by
fine cement slurry. The edge of the kitchen counter and
counter top wash basin shall be of double moulded with
fixing of extra marble piece for double moulding etc. all
complete. Sqm. 20
Rate in figure
Rate in word
59 Providing flooring with 450 x 450 x 25 mm PCC Designer's
Tiles of approved make design and shade set over 20 mm
thick cement mortar (1:3) mix joint panted with pigment to
match the shade of the tiles, laid in panels or in patterns with
necessary levelling course in floor, dado, risers and treads
of steps, pathways etc. including cost of all materials,
labour, conveyance, taxes, royalties, scaffolding, watering,
curing, sundries, tools and plants etc. complete as per the
direction of the Engineer-in-charge. Basic Price - Rs.40.00
to Rs.50.00 / Sft. Sqm. 200
Rate in figure
Rate in word
60 CEMENT BONDED FLOOR TILES:
Page 19
Sl.No. Description Unit Qty. Rate Amount
Providing of precast hydraulic pressed cement bonded
designed pigment tiles suitable for driveway ( average 20
mm thick) over a base of 1:4 ( 1 cement : 4 mortar ) all
complete including filling up the joints using pigmented
cement. The tile shall be of approved make and the shade
to be approved by the Architect / Owner before execution of
the work. The job is inclusive of all transportation, wastage,
royalities, taxes, etc. as applicable. Sqm. 60
Rate in figure
Rate in word
61 Providing of water proffing treatment to R.C.C. wall and
sunken floor slab shall be done using two coats of approved
make ready mix water profing membrane of approved make
on the smooth dry surface after finishing the R.C.C. surface
with 1:3 cement plaster and neat cement punning (only for
sunken slab) all complete and as per direction of Engineer-
in-charge. Sqm. 250
Rate in figure
Rate in word
62 Supplying all materials, labour and tools and plant and fixing
200 mm dia PVC rain waterpipes and fitting to walls with
nails and PVC hooks, bobbins and wooden plugs as
required with all fittings such as plain / door bends, tees, Y-
piece and short pieces etc. at all heights. Rmt. 92
Rate in figure
Rate in word
63 STONE CLADDING :
(i) Design, supply and installation of minimum 30 mm thk.
approved sand stone with appropriate sanding, moulding (as
per drawings and design) and cladding of reqd. sizehaving
straight or curved edge, may be chamfered on all sides
(approx. 6mm x 6mm.orarchitectural drawing) to form an
inverted ' v ' shaped joint with adjoining slab as per
architectural details to with stand wind pressure of 1.5 times
design wind pressure as IS875 part iii. The slabs shall be
fixed using MS framework with hot Dip galvanised with
anticorrosive treatment & 316 grade S.S. pins & anchor
fastners & the plumb line to be ascertained. The cladding
system shall be rear side ventilated, however, has to be
made waterproof by applying Silicone weather sealants
uniformly to all joints from rear side with all necessary
curing, cleaning, hardware & scaffolding etc. complete. For
finishing of the stone, dressing, colour variations etc. detail
specification to be strictly followed. Any surplus sealant /
mortar etc on the surface shall be cleaned off to the
satisfaction ofthe Architect. System to accommodate for
Asphaltic or cementious dam proofing asspecified all
complete as per direction of Engineer-in-charge. to be
approved byArchitect/PMC. Entire system & its calculations
are to be approved by structural
consultant Sqm. 250
Rate in figure
Page 20
Sl.No. Description Unit Qty. Rate Amount
Rate in word
(ii) Stone for above --30mm thk Stone (As per Architects
Choice) with 20% wastage Sqm. 900
Rate in figure
Rate in word
64 SPIDER GLAZING SYSTEM -SUSPENDED POINT FIX
SPIDER GLAZING:
Design wind velocity 300 km / hr
Design, supply and installation of Suspended Point fix
spider glazing system , custom designed to with stand the
design wind velocity of 300 kg/mtr confirming to IS -875
part III. (the system must pass the proof test at 1.5 times
design wind pressure ) with construction ,weather sealants
of Dow Corning or approved make, Stainless steel spider
system of grade 316 from Dorma /Linox / Austovian with
articulated bolt assembly supported on 21.53 mm laminated
glass fin system from the inside for lateral support at every
grid divison finishing up to floor level.Design to
accommodate floor movement of 20 mm at the floor bottom
aluminium channel, with SS 316 grade fasteners and anchor
bolts 304 grade of approved make, teflon/ nylon bushes &
separators to prevent bi-metallic contacts, all in complete
required to perform as per specification and drawing in
conjunction with BOQ.
The complete system to be designed to accommodate
thermal expansions and the seismic movements. All joints
shall be designed to 8 -10 mm sealant between glass to
glass and at perimeters 12 mm for expansion and sealing.
The counter sunk bolt shall have a rotation of atleast 4
degree in any direction and the bolt shall be designed to
reduce th Stresses on the glass by atleast 35-40% less in
actual as compared to theoretical calculation.
The glass shall be designed to accommodate designed wind
pressure,Accoustic & self dead load. The glass shall be
synergy clear(37.04 mm thk (6 mm YNE0158 + 3.04+16
mm+12mm + 10 mm)) fully tempered heat soak tested.
The non visible aluminium surfaces shall have minimum
chromatizing treatment. The stainless steel shall have satin
brush finish. The quote rate shall include all design,
engineering & shop drawing approval from architect &
consultant. The quote rate shall include all Taxes, duties,
statutory obligations and safety code compliance as per
structural engineer.
The quote rate shall include all design, engineering & shop
drawing approval from architect & consultant. The quote rate
shall include all Taxes, duties, statutory obligations and
safety code compliance as per structural engineer.
Complete system FT Heat soak glass panels & 21.53 mm
thk Clear Fully Tempered Fins .etc. complete in all respect
as directed by Engineer-in-charge. Sqm. 1080
Rate in figure
Page 21
Sl.No. Description Unit Qty. Rate Amount
Rate in word
65 WCP GLAZING:
Design supply and installation of WCP from Door ma Or
equivalent to with stand the wind velocity of of 300kg/mtr
confirming to IS -875 part III. ( the system must pass the
proof test at 1.5 times design wind pressure ) with
construction ,weather sealants of Dow Corning or approved
make, Stainless steel Uchannel system of grade 316 from
Dorma /Linox / Austovian. The system shall be designed to
take care of 20 mm building movement with butt joint
between the glass and U chanel at the bottom. At top U
channel shall be provided wth bolts to hold the glass and
distribut the load to the top structure were as the bottom u
channel shall be designed to cater to building movement of
20 mm. At bottom EPDM support block shall be provided .
The u chanel shall be fixed to the lintel and cill level with
WOOD screw and Raul plug. The butt joint shall be provided
with Acoustic Sealant. The Top u channel shall be with Cap
so that the bolts at the top shall not be Visible. The top bolt
shall be fixed at 15Nm with LNkey. The glass shall be 13.52
mm thk laminated glass with main glass
as synergy Clear.
The quote rate shall include all design, engineering & shop
drawing approval from architect & consultant. The quote rate
shall include all Taxes, duties, statutory obligations and
safety code compliance as per PMC . Sqm. 200.00
Rate in figure
Rate in word
66 PATCH FITTING :
Design supply and installation of Patch Fitting Fixed glazing
from Door ma Or equivalent to with stand the wind velocity
of of 300 kg/sq.mtr confirming to IS -875 part III. ( the
system must pass the proof test at 1.5 times design wind
pressure ) with construction ,weather sealants of Dow
Corning or approved make, Stainless steel Patch system of
grade 316 from Dorma /Linox / Austovian. The system shall
be designed to take care of 20 mm building movement with
butt joint between the glass . The Corner patches shall be
equvalent to PT 91 , and the patches with Fin were ever
required shall be given. the Glass to glass Patch can 1.53 or
equivalent series and for the Doors closure patch shall of PT
20 and Pt 10 wiht floor spring of BT80 or equivalent. The
patches shall be designed for heavy dead loads and wind
loads. The glass shall be 13.52 mm thk laminated glass wiht
main glass as synergy Clear.
The quote rate shall include all design, engineering & shop
drawing approval from architect & consultant. The quote rate
shall include all Taxes, duties, statutory obligations and
safety code compliance as per PMC. Sqm. 200
Rate in figure
Rate in word
Page 22
Sl.No. Description Unit Qty. Rate Amount
67 AlUMINIUM LOUVERS FOR FAÇADE:
Design, supply and install aluminium screen louvers on the
MS structural frame work designed to with stand wind
velocity of 300kg/m2 made out of 132 X 40 x 2 mm Aero
shape aluminium extruded profiles spaced at 80 mm
distance with support grid work of aluminium extruded
profile of 136mm x 40 mm tube PROFILE duly PVDF
coated in Metalic or solid color in 35 microns. the system
shall be supported with help of M.S hot dip bracket at the
edges to hold the Louver Unit . The louver unit shall consists
of Facia And the Outer frame to which the lovers shall be
fixed with S.S Screws.The system shall be design to
accommodate the building movements, thermal expansion
and seismic movements etc. complete in all respect as
directed by Engineer-in-charge.
Sqm. 675
Rate in figure
Rate in word
68 FOR DGU GLASS PANELS:
Providing and fixing 24mm DGU with frit pattern in Structural
Glazing System, DGU configuration 6mm HS + 12mm air
gap + 6mm HS with structurural silicone sealant of DC983
/G E with Double Sided Tape or equivalent alongwith
application of weather sealant DC 789 / G E with backer rod
of required diameter on outer surface and fixed onto
mullions and transoms with all approved standard
accessories and hardwares.
Glazing Configuration: 12 mm DGU comprising of 6mm
exterior HS Clear Glass with Low E coating on surface 2 +
12mm air gap + interior 6mm HS Clear Glass with 50%
polka dot frit pattern on surface 1 - frit pattern as per
Architect.
Glazing Spectomectric Properties: Light Transmission (LT) -
40-50%, Light Reflection External (LR) - 11-15%, Light
Reflection Internal (LR) - 11-15%, Shading Coefficient (SC) -
0.30-0.50, U Value - 1.3-1.6
The quote rate shall include all design, engineering & shop
drawing approval from architect & consultant/engineer-in-
charge. The quote rate shall include all direct & indirect
taxes, duties, transportation, lead and lift, loading-unloading
at work space, stacking, storage, wastage,statutory
obligations and safety code compliance as per engineer-in-
charge Sqm. 60
Rate in figure
Rate in word
Total :
For M/s. RATH ARCHITECTONIC.
Page 23
Sl.No. Description Unit Qty. Rate Amount
P.H. WORKS
B.O.Q. FOR WATER SUPPLY INSTALLATION
69 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)
pipes of approved make as per IS: 15778 & ASTM-D 2846,
GRADE SDR 13.5(CLASS-2)., having thermal stability for
hot & cold water supply, including all CPVC plain & brass
threaded fittings i/c fixing the pipe with clamps at 1.00 m
spacing. This includes jointing of pipes & fittings, with one
step CPVC solvent cement and the cost of cutting chases
and making good the same including testing of joints
complete as per direction of Engineer-in-Charge.(Concealed
work, including cutting chases and making good the wall
etc.)
(a) 15 mm nominal outer dia pipes. Mtr. 95
Rate in figure
Rate in word
(b) 20 mm nominal outer dia pipes. Mtr. 150
Rate in figure
Rate in word
(c) 25 mm nominal outer dia pipes. Mtr. 90
Rate in figure
Rate in word
(d) 32 mm nominal outer dia pipes. Mtr. 92
Rate in figure
Rate in word
(e) 40 mm nominal outer dia pipes. Mtr. 52
Rate in figure
Rate in word
70 Providing and fixing of Rigid PVC (UPVC) pipes of approved
make (as per ASTM D-1785 SCH-40) complete with P.V.C
Fittings including trenching and refilling etc. (external work)
and shall be fitted on vertical face of walls and roof water
ring line using P.V.C Clamps all complete as per direction
of Engineer-in-charge.
(a) 25 mm dia nominal dia. Mtr. 25
Rate in figure
Rate in word
(b) 32 mm dia nominal dia. Mtr. 30
Rate in figure
Rate in word
(c) 40 mm dia nominal dia. Mtr. 215
Rate in figure
Rate in word
71 Providing and fixings ball valve of approved quality screwed
end as per direction of Engineer-in-charge.
Page 24
Sl.No. Description Unit Qty. Rate Amount
(a) 25 mm nominal bore No. 6
Rate in figure
Rate in word
(b) 32 mm nominal bore No. 6
Rate in figure
Rate in word
(c) 40 mm nominal bore No. 8
Rate in figure
Rate in word
72 Providing and fixing ball valve (brass) of approved quality,
High or low pressure,with plastic floats complete as per
direction of Engineer-in-charge.
(a) 100 mm nominal bore No. 2
Rate in figure
Rate in word
73 Providing and fixings Union of approved quality (screwed
end) all complete as per direction of Engineer-in-charge.
(a) 25 mm nominal bore No. 6
Rate in figure
Rate in word
(b) 32 mm nominal bore No. 6
Rate in figure
Rate in word
(c) 40 mm nominal bore No. 8
Rate in figure
Rate in word
74 Providing and fixing reducer of approved quality (screwed
end) all complete as per direction of Engineer-in-charge.
(a) 25 mm dia.x 20 mm dia. No. 10
Rate in figure
Rate in word
75 Constructing masonry chamber 30x30x50 cm inside, in brick
work in cement mortar 1:4 (1 cement :4coarse sand) for
stop cock, with C.I. surface box 100x100x75 mm (inside)
with hinged cover fixed in cement concrete slab 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size), i/c necessary excavation, foundation concrete
1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate
40 mm nominal size) and inside plastering with cement
mortar 1:3 (1 cement : 3 coarse sand)12 mm thick, finished
with a floating coat of neat cement complete as per standard
design:
With common burnt clay F.P.S. (non modular ) bricks of
class designation 7.5 No. 1
Rate in figure
Page 25
Sl.No. Description Unit Qty. Rate Amount
Rate in word
Total :
B.O.Q. FOR SANITARY INSTALLATION
76 Providing, fixing, testing and commissioning of white glazed
wall hung type European water closet with low level
flushing cistern of capacity 7.5 Lt., C.P accessories, C.P.
bolts, nuts, supporting arrangements, white bakelite seat &
cover with C.P. hinges & rubber buffers, complete with all
accessories, including cutting & making good the walls &
floors wherever required of make as shown on drawing.
No. 28
Rate in figure
Rate in word
77 Providig and fixing white vitreous china flat back or half stall
urinal of 580 x 380 x 350 mm with automatic flushing cistern
(of approved make) with fittings, C.I. / M.S. brackets
standard size C.P. brass flush pipe, spreaders with unions
and clamps (all in C.P. brass) with waste fitting as per IS :
2556, C.I. trap with outlet grating and other couplings in
C.P. brass including painting of fittings and brackets, cutting
and making good the walls and floors wherever requird.
Single stall urinal with 5 Ltr. P.V.C. automatic flushing
cistern. No. 16
Rate in figure
Rate in word
78 Providing and fixing one piece construction white vitreous
china squatting plate with an integral longitudinal flushing
pipe, white PVC. automatic flushing cistern, with fittings,
standard size G.I. / PVC flush pipe for back and front flush
with standard spreader pipes with fittings, G.I clamps and
C.P. brass coupling complete, including painting of fittings
and cutting and making good the walls and floors etc.
wherever required:
Single squatting plate with 5 litre PVC. automatic flushing
cistern No. 10
Rate in figure
Rate in word
79 Providing and fixing of 32 mm dia C.P. brass waste coupling
for sink and wash basin. No. 42
Rate in figure
Rate in word
80 Providing and fixing of P.V.C. flexible waste pipe for sink
including 32 mm dia P.V.C. waste fittings complete. No. 4
Rate in figure
Rate in word
81 Providing and fixing stainless steel jali (grating) with or
without hole for waste pipe for floor / Nahani trap.
100 mm dia. weight not less than 100 gms. No. 63
Rate in figure
Rate in word
Page 26
Sl.No. Description Unit Qty. Rate Amount
82 Providing and fixing waste coupling(grating) without hole for
waste pipe for floor / Nahani trap.
50 mm dia. No. 15
Rate in figure
Rate in word
83 Providing and fixing toilet paper holder. No. 28
Rate in figure
Rate in word
84 Providing, fitting and fixing of C.P. brass bottle trap in wash
basin including all fittings etc. all complete. No. 38
Rate in figure
Rate in word
* C.P. BRASS FITTINGS :
85 Providing and fixing C.P. brass bib cock confirming to IS :
8931 of approved make with 15 mm nominal bore.
Sample to be approved by Architect / Owner before
procurement. No. 6
Rate in figure
Rate in word
86 Providing and fixing C.P. brass long nose bib cock with wall
flange confirming to IS : 8931 and weighing not less than
810 gms of approved make with 15 mm nominal bore.
Sample to be approved by Architect / Owner before
procurement. No. 6
Rate in figure
Rate in word
87 Providing, fitting and fixing of C.P. brass pillar cock
confirming to IS : 8931 of approved make.
Sample to be approved by Architect / Owner before
procurement. No. 38
Rate in figure
Rate in word
88 Providing and fixing of C.P. brass central hole basin mixture
of approved make without popup waste system confirming
to IS : 8931 of approved make.
Sample to be approved by Engineer-in-charge before
procurement. No. 38
Rate in figure
Rate in word
89 Providing, fitting and fixing of C.P. brass wall mixer of
approved make with provision for cover head shower with
115 mm long bend pipe confirming to IS Standards of
approved make.
Page 27
Sl.No. Description Unit Qty. Rate Amount
Sample to be approved by Engineer-in-charge before
procurement. No. 2
Rate in figure
Rate in word
90 Providing, fitting and fixing of C.P. brass shower arm of
approved make190 mm long heavy body with wall flange
and pressure adjustable shower of approved make.
Sample to be approved by Engineer-in-charge before
procurement. No. 2
Rate in figure
Rate in word
91 Providing and fixing brass tap confirming to IS : 8931 of
approved make with 15 mm nominal bore.
Sample to be approved by Architect / Owner before
procurement. No. 2
Rate in figure
Rate in word
92 Providing, fitting and fixing of health faucet confirming to IS :
8931 of approved make.
Sample to be approved by Architect / Owner before
procurement. No. 28
Rate in figure
Rate in word
93 Supplying and fixing of Electrical storage water heater of
capacity 15 ltr. of approved make,in built blue diamond
glass lining technology inside the inner tank.The cost
including of all materials, labours, T&P, taxes, royalities,
transportation etc. all complete as per the direction of
Engineer-in-charge. Nos. 2
Rate in figure
Rate in word
94 Providing and fixing of C.P. brass concealed stop cock extra
heavy body with 15 mm nominal bore all complete with wall
flange of approved make.
Sample to be approved by Architect / Owner before
procurement. No. 66
Rate in figure
Rate in word
95 Providing and fixing of C.P. brass angular stop cock with 15
mm nominal bore of approved make.
Sample to be approved by Architect / Owner before
procurement. No. 32
Rate in figure
Rate in word
96 Providing of following C.P. brass toilet accessories in toilets
of approved make.
Page 28
Sl.No. Description Unit Qty. Rate Amount
(i) Towel rail 600 mm No. 28
Rate in figure
Rate in word
(ii) Recessed Soap dish No. 32
Rate in figure
Rate in word
(iii) Towel ring No. 50
Rate in figure
Rate in word
(iv) Bath room and basin mirror of size 600 mm x 900 mm No. 28
Rate in figure
Rate in word
97 Providing and fixing of 600 mm long heavy duty C.P.
connecting tube with heavy quality C.P. brass addjustable
bolts on both end. No. 92
Rate in figure
Rate in word
98 Providing and fixing white vitreous china under counter wash
basin with 32 mm C.P. Brass waste of standard pattern, 32
mm diameter C.P. Bottle trap and unions complete including
cutting and making good the walls wherever required. All
C.P. brass waste and bottle trap of approved make. No. 28
Rate in figure
Rate in word
Total :
B.O.Q. FOR DRAINAGE
99 Supplying all materials, labour, fitting and fixing of the
unplasticised - Rigid PVC (SWR) soil waste and vent pipe
confirming to IS : 13592 type A on the wall surface and
below ground and floor level, fixing the pipe on wall surface
with the PVC clips including jointing with seal ring
(confirming to IS : 5382 leaving 10 mm gap for Thermal
expansion) and solvent solution as per manufacturer
specification for UPVC (SWR) pipes and with solvent
cement for rigid PVC pipes including cutting the pipes into
required length wastage and testing as per specifications,
necessary earth work in excavation and filling of the pipe
line trenches providing staging and scafollding as per
requirement at site.
(a) 40 mm dia U-PVC (SWR) pipe. Mtr. 92
Rate in figure
Rate in word
(b) 110 mm dia U-PVC (SWR) pipe. Mtr. 220
Rate in figure
Rate in word
Page 29
Sl.No. Description Unit Qty. Rate Amount
100 Supplying all materials, labour, fitting and fixing of the
unplasticised - Rigid PVC waste and vent pipe confirming to
IS : 13592 type A on the wall surface and below ground and
floor level, fixing the pipe on wall surface with the PVC clips
including jointing with seal ring (confirming to IS : 5382
leaving 10 mm gap for Thermal expansion) and solvent
solution as per manufacturer specification for UPVC pipes
and with solvent cement for rigid PVC pipes including cutting
the pipes into required length wastage and testing as per
specifications, necessary earth work in excavation and filling
of the pipe line trenches providing staging and scafollding as
per requirement at site.
(a) 32 mm dia U-PVC waste pipe. Mtr. 72
Rate in figure
Rate in word
(b) 40 mm dia U-PVC waste pipe. Mtr. 92
Rate in figure
Rate in word
(c) 110 mm dia U-PVC waste pipe. Mtr. 230
Rate in figure
Rate in word
(d) 200 mm dia U-PVC waste pipe. Mtr. 70
Rate in figure
Rate in word
101 Providing and fixing Unplasticised-PVC pipe clips of
approved design to Unplasticised-PVC (SWR) pipes by
means of 50 x 50 x 50 mm hard wood plugs, screwed with S
/ S screws of required length including cutting brick work
and fixing in cement mortar 1:4 (1 cement : 4 coarse sand)
and making good the wall etc. all complete.
110 mm No. 517
Rate in figure
Rate in word
102 Providing and fixing on wall face Unplasticised-PVC (SWR)
moulded fitting / accessories for U-PVC (SWR) pipes
confirming to IS : 13592 Type-A including jointing with seal
ring confirming to IS : 5382 leaving 10 mm gap for thermal
expansion.
(a) 125 mm x 110 mm U-PVC (SWR) P / S Trap with minimum
water seal of 50 mm as per IS : 5329 and IS : 2556
(Part-XIII). No. 28
Rate in figure
Rate in word
(b) P.V.C. Floor trap 110 mm x 75 mm PVC (SWR) No. 50
Rate in figure
Rate in word
Page 30
Sl.No. Description Unit Qty. Rate Amount
(c) Multiple floor trap 150 mm x 75 mm x 50 mm No. 13
Rate in figure
Rate in word
(d) Double Y with door 110 mm dia U-PVC (SWR) No. 10
Rate in figure
Rate in word
(e) Double Y plain 110 mm dia U-PVC (SWR) No. 10
Rate in figure
Rate in word
(f) 110 mm dia 90 degree U-PVC (SWR) bend with door No. 25
Rate in figure
Rate in word
(g) 110 mm dia U-PVC (SWR) plain bend to use for HR bend
No. 30
Rate in figure
Rate in word
(h) 110 mm dia 45 degree U-PVC (SWR) plain bend to use for
offset. No. 30
Rate in figure
Rate in word
(i) 110 mm dia U-PVC (SWR) 90 degree plain bend for EWC
No. 28
Rate in figure
Rate in word
(j) 110 mm dia U-PVC (SWR) vent cover. No. 25
Rate in figure
Rate in word
(k) Single T with door 110 mm dia U-PVC (SWR) No. 25
Rate in figure
Rate in word
(l) Double junction with door 110 mm dia U-PVC (SWR) No. 10
Rate in figure
Rate in word
103 Providing and laying non-preessure NP2 class (light duty)
R.C.C. pipes with collars jointed with stiff mixture of cement
mortar in the proportion of 1:2 (1 cement : 2 fine sand)
including testing of joints etc. complete.
(i) 150 mm dia R.C.C. Hume Pipe Mtr. 250
Rate in figure
Rate in word
(ii) 200 mm dia R.C.C. Hume Pipe Mtr. 120
Rate in figure
Rate in word
(iii) 250 mm dia R.C.C. Hume Pipe Mtr. 150
Page 31
Sl.No. Description Unit Qty. Rate Amount
Rate in figure
Rate in word
104 Providing and laying cement concrete 1:5:10 (1 cement : 5
coarse sand : 10 graded stone aggreagate 40 mm nominal
size) alround R.C.C. pipes including bed concrete as per
P.W.D. design:
(i) 150 mm dia R.C.C. Hume Pipe Mtr. 250
Rate in figure
Rate in word
(ii) 200 mm dia R.C.C. Hume Pipe Mtr. 120
Rate in figure
Rate in word
(iii) 250 mm dia R.C.C. Hume Pipe Mtr. 150
Rate in figure
Rate in word
105 Providing and fixing square-mouth S.W. gully trap class SP-
1 complete with C.I. grating brick masonry chamber with
water tight C.I. cover with frame of 300x300 mm size
(inside) the weight of cover to be notless than 4.50 kg and
frame to be not less than 2.70 kg as per standard design :
180 x 150 mm size P type. No. 10
Rate in figure
Rate in word
106 Constructing brick masonry manhole in cement mortar 1:4 (
1 cement : 4 coarse sand) with R.C.C. top slab with 1:2:4
mix (1 cement : 2 coarse sand : 4 graded stone aggregate
20 mm nominal size), foundation concrete 1:4:8 mix (1
cement : 4 coarse sand : 8 graded stone aggregate 40 mm
nominal size), inside plastering 12 mm thick with cement
mortar 1:3 (1 cement : 3 coarse sand) finished with floating
coat of neat cement and making channels in cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) finished with a floating coat
of neat cement complete as per standard
design:
Inside size 90x80 cm and 75 cm deep including C.I. cover
with frame (light duty) 455x610 mm internal dimensions,
total weight of cover and frame to be not less than 38 kg
(weight of cover 23 kg and weight of frame 15 kg):
No. 12
Rate in figure
Rate in word
Page 32
Sl.No. Description Unit Qty. Rate Amount
107 Constructing brick masonry chamber for underground C.I.
inspection chamber and bends with bricks in cement mortar
1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light
duty) 455x610 mm internal dimensions, total weight of cover
with frame to be not less than 38 kg (weight of cover 23 kg
and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) foundation concrete 1:5:10 (1 cement : 5 fine
sand : 10 graded stone aggregate 40 mm nominal size),
inside plastering 12 mm thick with cement mortar 1:3 (1
cement : 3 coarse sand) finished smooth with a floating coat
of neat cement on walls and bed concrete etc. complete as
per standard
design:
(a) Inside dimensions 600 x 850 mm and 45 cm deep for line
with three or more inletes. No. 4
Rate in figure
Rate in word
(b) Inside dimensions 455 x 610 mm and 45 cm deep for line
with three or more inletes. No. 4
Rate in figure
Rate in word
Total :
Net total :
For M/s. RATH ARCHITECTONIC.
B.O.Q. FOR KNX LIGHTING MANAGEMENT SYSTEM
1 Supply, installation and Commissioning of Power supply
unit, with integrated choke, rated operational voltage AC
120...230 V, 50...60 Hz, DC 220 V, output voltage 29 V DC,
output current 320 mA, with additional non-choke-protected
output for 29 V DC for supply of a second bus line via an
external choke etc. complete in all respect as directed by
Engineer-in-charge. No 2
Rate in figure
Rate in word
2 Supply, installation and Commissioning of Power supply
unit, with integrated choke, rated operational voltage AC
120...230 V, 50...60 Hz, DC 220 V, output voltage 29 V DC,
output current 160 mA, with additional non-choke-protected
output for 29 V DC for supply of a second bus line via an
external choke etc. complete in all respect as directed by
Engineer-in-charge. No 1
Rate in figure
Rate in word
3 Supply, installation and Commissioning of DEHN
overvoltage protection, as fine protection for bus devices
etc. complete in all respect as directed by Engineer-in-
charge. No 3
Rate in figure Page 33
Sl.No. Description Unit Qty. Rate Amount
Rate in word
4 Supply, installation and Commissioning of Bus terminal‚ 2-
pole‚ 4 plug-in connectors‚ red/dark gray etc. complete in all
respect as directed by Engineer-in-charge. No 200
Rate in figure
Rate in word
5 Supply, installation and Commissioning of IP Router for
interconnection of bus lines or bus areas via a fast data
network (Ethernet 10BaseT) with Internet Protocol (IP), to
be used as line, area and system coupler etc. complete in
all respect as directed by Engineer-in-charge. No 1
Rate in figure
Rate in word
6 Supply, installation and Commissioning of Line Coupler For
data exchange between two EIB bus lines via telegrams
containing up to 64 bytes, can be used as a line coupler (for
coupling a line to a main line), backbone coupler (for
coupling a main line to the backbone line) etc. complete in
all respect as directed by Engineer-in-charge. No 2
Rate in figure
Rate in word
7 Supply, installation and Commissioning of IP Control Centre
for communication between KNX devices and PC`s and, in
connection with a LAN- / WLAN modem or DSL router, for
remote access to a KNX installation, for usage as an
interface for the software and as an interface for a
visualization, with usage of the KNXnet/IP protocol etc.
complete in all respect as directed by Engineer-in-charge. No 1
Rate in figure
Rate in word
8 Supply, installation and Commissioning of IP Gateway KNX-
BACnet for communication between KNX TP devices and
PCs or other devices with an Ethernet (100BaseT) interface,
as well as in conjunction with a LAN modem or DSL router
for remote access to an KNX TP installation, for use as an
interface with a BACnet Application Specific Controller (B-
ASC) as Gateway between KNX TP and BACnet IP etc.
complete in all respect as directed by Engineer-in-charge. No 1
Rate in figure
Rate in word
Page 34
Sl.No. Description Unit Qty. Rate Amount
9 Supply, installation and Commissioning of Switch Actuator
with relay contact per output as switching element,16 X
230VAC, 10A with pushbutton for switching between bus
operation and direct operation, with a yellow LED indicating
direct operation, with 1 red LED per output channel to
indicate the switch status, with one pushbutton per output
channel to activate the corresponding output through a
toggle function in direct operating mode, operational when
connected to AC 230V etc. complete in all respect as
directed by Engineer-in-charge. No 3
Rate in figure
Rate in word
10 Supply, installation and Commissioning of KNX/DALI
Gateway Plus for communication via KNX EIB with
electronic ballasts (ECG) with a DALI interface, with one
DALI output acc. to IEC 62386, each for communication with
up to 64 DALI ECG and at least 10 sensors with an
integrated power supply with input voltage AC 110-240 V, 50-
60 Hz or DC 120-240 V for powering the gateway
electronics and DALI output, with a maximum DALI output
voltage of 19V, short circuit resistant, with incorrect voltage
detection during commissioning, whether incorrect power
line is connected to a DALI output, with LED display for
displaying operation mode and error messages etc.
complete in all respect as directed by Engineer-in-charge. No 2
Rate in figure
Rate in word
11 Supply, installation and Commissioning of KNX/DALI
Gateway Twin Plus for communication via KNX EIB with
electronic ballasts (ECG) with a DALI interface, with two (2)
DALI output acc. to IEC 62386, each for communication with
up to 64 DALI ECG and at least 10 sensors with an
integrated power supply with input voltage AC 110-240 V, 50-
60 Hz or DC 120-240 V for powering the gateway
electronics and DALI output, with a maximum DALI output
voltage of 19V, short circuit resistant, with incorrect voltage
detection during commissioning, whether incorrect power
line is connected to a DALI output, with LED display for
displaying operation mode and error messages, etc.
complete in all respect as directed by Engineer-in-charge. No 2
Rate in figure
Rate in word
Page 35
Sl.No. Description Unit Qty. Rate Amount
12 Universal dimmer, main module 1x 300 VA, with interface
for connecting universal dimmer submodules and with
software for controlling up to 5 universal dimmer
submodules, with power supply of electronics via AC 230 V,
50 - 60 Hz, with one output for switching and dimming
resistive, inductive or capacitive loads, with automatic
adjustment to leading edge or trailing edge control,
depending on the type of load, with electronic protection of
the output against overload, short circuit and temperature
rise, etc. complete in all respect as directed by Engineer-in-
charge. No 3
Rate in figure
Rate in word
13 Supply, installation and Commissioning of Universal
dimmer, submodule 1x 1,000 VA, with interface for
connecting the universal dimmer submodule to the universal
dimmer main module and / or connecting further universal
dimmer submodules, with power supply of electronics via
AC 230 V, 50 - 60 Hz, with one output for switching and
dimming resistive, inductive or capacitive loads, with
automatic adjustment to leading edge or trailing edge
control, depending on the type of load, with electronic
protection of the output against overload, short circuit and
temperature rise. etc. complete in all respect as directed by
Engineer-in-charge. No 12
Rate in figure
Rate in word
14 Supply, installation and Commissioning of Venetian blind
actuator, quadruple, for the separate control per actuator
channel of a sun protection drive with motor for AC 230 V
and electromechanical or electronic limit switches, with
electrically interlocked relays to reverse the direction of
rotation, relay contacts rated for nominal voltage AC 230 V,
6 A (resistive load) etc. complete in all respect as directed
by Engineer-in-charge. No 1
Rate in figure
Rate in word
15 Supply, installation and Commissioning of Venetian blind
actuator, 8x AC 230 V, 6 A, for control of one sun protection,
door or window drive with a motor for AC 230V and
electromechanical or electronic limit switches per actuator
channel, with electrically interlocked relays to reverse the
direction of rotation, relay contacts rated for nominal voltage
AC 230 V, 6 A (resistive load), with 2 terminals per channel
for interfacing of UP and DOWN connector of the drive etc.
complete in all respect as directed by Engineer-in-charge. No 1
Rate in figure
Rate in word
Page 36
Sl.No. Description Unit Qty. Rate Amount
16 Supply, installation and Commissioning of Room Controller
Contouch‚ incl. bus coupling unit‚ aluminium metallic as
multifunctional display-/control panel for KNX, with 320 x
240 pixels, 2,8“ LCD colour display, for the display and
control of at least 18 adjustable room control functions:
toggle, switching on, switching off, door bell function on,
door bell function off, dimming, solar protection control, send
1 byte value, send 2 byte value, forced control, display
messages, recall and save scenes, warning and alarm
messaging, with touch screen and rotary/pushing function
via rotary knob etc. complete in all respect as directed by
Engineer-in-charge. No 4
Rate in figure
Rate in word
17 Supply, installation and Commissioning of Siemens Cavity
Box for Push Buttons etc. complete in all respect as
directed by Engineer-in-charge. No 4
Rate in figure
Rate in word
18 Supply, installation and Commissioning of Colour Touch
Panel as multifunctional display-/control panel for the KNX,
with 320 x 240 pixels, 5,7“ TFT-colour display, with touch
screen, with LED background illumination, which you dim
with the user interface, for the display and control of at least
210 communication objects on at least 20 display pages,
with time programme as a week programme for at least 110
communication objects and at least 10 switch tasks per
weekday, etc. complete in all respect as directed by
Engineer-in-charge. No 1
Rate in figure
Rate in word
19 Supply and instalation of Design Frame for colour Touch
Panels etc. complete in all respect as directed by Engineer-
in-charge. No 1
Rate in figure
Rate in word
20 Supply and installation of Siemens Cavity Box for Touch
Panel etc. complete in all respect as directed by Engineer-in-
charge. No 1
Rate in figure
Rate in word
21 Supply, installation and Commissioning of Lutron tension
system for roof skylight etc. complete in all respect as
directed by Engineer-in-charge. No 6
Rate in figure
Rate in word
22 Supply, installation and Commissioning of Dali Ballast etc.
complete in all respect as directed by Engineer-in-charge. No 1
Rate in figure
Rate in word
For M/s Rath Architectonic. TOTAL:
Page 37
Sl.No. Description Unit Qty. Rate Amount
ELECTRICAL WORKS
DETAIL B.O.Q FOR INTERNAL ELECTRICAL INSTALLATION WORKS
1 Supply of all required materials and recessed (concealed)
wiring to proposed light points / fan/ exhaust fan/ call bell
points with 2 (1 x1.5 sq.mm) PVC insulated 1000v grade
FRLS copper wire run inside 19 /25 mm PVC conduit pipe of
14 SWG or flexible conduit pipe laid on surface concelaed in
wall / ceiling along with 1 (1 x 1 sq.mm.) PVC insulated
FRLS copper wire as earth continuity conductor and
complete in all respect including with use of clip-in type
modular plates, boxes, switches, ceiling roses, junction
boxes with bakelite cover as specified and making good to
the damages caused and complete as per direction of
Engineer-in-charge / Consultant.
(a) Light points. No. 70
Rate in word :
Rate in Figure :
(b) Two way light points No. 20
Rate in word :
Rate in Figure :
(c) Fan point with regulator (electronic step regulator) No. 45
Rate in word :
Rate in Figure :
(d) Exhaust fan point No. 25
Rate in word :
Rate in Figure :
2 Supply of all required materials and recessed wiring to 2/3
pin clip-in modular type 5 Amp plug socket points with 2 (1 x
2.5 sq.mm.) PVC insulated 1100 V grade stranded single
core FRLS copper wire run inside 19 mm PVC Conduit (14
S.W.G) pipe laid concealed in surface wall / ceiling along
with 1 (1 x 1.0 sq.mm) PVC insulated FRLS copper wire as
earth continuity conductor and complete in all respect
including 5 pin 5 A sockets, switches, plates, boxes and
cover as specified and making good to the damages caused
and complete with all respect as per the direction of
Engineer-in-charge / Consultant.
(a) Existing No. 40
Rate in word :
Rate in Figure :
(b) Separate No. 70
Rate in word :
Rate in Figure :
Page 38
Sl.No. Description Unit Qty. Rate Amount
3 Supply of all required materials and recessed wiring to clip-
in modular type 6 pin, 15/5 Amp plug socket points on
surface of wall including the modular boxes switches with
indicator plates, screws and complete in all respect including
making good to the damages caused and as per direction of
Consultant/ Engineer-in-charge. No. 40
Rate in word :
Rate in Figure :
4 Supply of all required materials and recessed wiring to
circuit / sub-mains with following number and sizes of PVC
insulated FRLS 1100 volt grade stranded copper wire run
inside 19/ 25/ 32mm PVC conduit (14 S.W.G.) pipe laid on
surface of wall / ceiling and copper wire as earth continuity
conductor and complete in all respect including making good
to all damages caused and as per the direction of
Consultant and Engineer-in-charge.
(i) Recessed wiring with 2 (1 x 2.5 sqmm) + 1 x (1 x 1 sqmm)
copper wire from LDB to SDB. Mtr. 2500
Rate in word :
Rate in Figure :
(ii) Recessed wiring with 2 (1 x 4 sqmm) + 1 x (1 x 2.5 sqmm)
copper wire from LDB to individual 16 Amp. Socket & A.C.
Point. Mtr. 2000
Rate in word :
Rate in Figure :
(iii) Recessed wiring with 4 (1 x 6 sqmm) + 1 x (1 x 2.5 sqmm)
copper wire from Main panel to L.D.B. Mtr. 1000
Rate in word :
Rate in Figure :
(iv) Recessed wiring with 4 (1 x 10 sqmm) + 1 x (1 x 2.5 sqmm)
copper wire from Main panel to P.D.B. Mtr. 300
Rate in word :
Rate in Figure :
5 Supply, delivery, installation, testing and commissioning of
L.T. indoor free standing floor mounted type distribution
boards made out of 2 mm thick CR sheet metal duly acid
treated, primered and painted with 2 coats of enamel paint
of smoke grey colour, having hinged door and
compartmental arrangement for each equipment and busbar
chamber on the top of the panel running horizontal
throughout it's length duly dust, damp and vermin proof
having provision for cable/conduit entry (cable alley and
detachable gland plate), fitted with suitable rated TB for
termination of incoming and out going cables/wires (no
cable/ wire shall be terminated directly on SFU/MCB)( all
termination shall be done by using proper size of Lugs and
glanding is to be done for cable entry and exit), earthing stud
as per specification mentioned below, duly factory wired
conforming to the relevant ISS and as per special conditions
of contract, making good to the damages caused and
complete as per direction of Engineer-in-charge or
Consultan
Page 39
Sl.No. Description Unit Qty. Rate Amount
(i) Main Panel :
Incoming :
1600 Amp Four Pole, 50KA , MDO Type Microprocessore
relese with short circuit, over current, earth fault relays (one
extra CT for neutral to un balanced load on ACB ) - 2 No.
RYB LED Type Indication lamp assembly - Set - 2
0 - 500 V Voltmeter - 2Nos.
0 - 2000Amp. Ammeter -2 Nos.
Instrument protection fuse - 2 Set
3 phase 4 wire KWH meter 2000 amp CT operted -2 Nos.
BUS COUPLER :
1600 amp 4pole , 50 KA MDO type, Microprocessor release
(one extra CT for neutral to un blance load on ACB
)including all acessories - 1Nos.
4 x 2000Amp capacity AL.bus bar for incoming side with
sleeve -1 Set
OUT GOING :
1250amp F.P.50 KA, MDO type, ACB - 2 Nos.
0-1600 Amp Ammeter with selector switch - 2 Set.
1250 / 5 amp CT - 6 Nos.
250 / 5 amp CT - 6 Nos.
160 / 5 amp CT - 6 Nos.
100 / 5 amp CT - 6 Nos.
250 amp TPN SFU with HRC Fuse -3 No.
125 Amp TPN SFU with HRC Fuse - 3 No.
100 Amp TPN SFU with HRC Fuse - 2 No. Set 1
Rate in word :
Rate in Figure :
6 Supply, delivery, installation, testing and commissioning of
L.T. indoor free standing floor mounted type distribution
boards made out of 2 mm thick CR sheet metal duly acid
treated, primered and painted with 2 coats of enamel paint
of smoke grey colour, having hinged door and
compartmental arrangement for each equipment and busbar
chamber on the top of the panel running horizontal
throughout it's length duly dust, damp and vermin proof
having provision for cable/conduit entry (cable alley and
detachable gland plate), fitted with suitable rated TB for
termination of incoming and out going cables/wires (no
cable/ wire shall be terminated directly on SFU/MCB)( all
termination shall be done by using proper size of Lugs and
glanding is to be done for cable entry and exit), earthing stud
as per specification mentioned below, duly factory wired
conforming to the relevant ISS and as per special conditions
of contract, making good to the damages caused and
complete as per direction of Engineer-in-charge or
Consultan o
(i) Ground Floor Panel :
Page 40
Sl.No. Description Unit Qty. Rate Amount
Incoming
250 Amp TPN SFU with HRC cartridge link Fuse - 3 set. - 1
No.
RYB LED Type Indication lamp assembly - Set - 1
4 x 300 Amp Electrolytic copper busbar with sleeve- 1 Set.
0-500 Volt Voltmeter - 1 Set.
0-300 Amp. Ammeter- 1 Set.
Out going
63 Amp TPN MCB -11 No. Set 1
Rate in word :
Rate in Figure :
(ii) First Floor Panel :
Incoming
250 Amp TPN SFU with HRC cartridge link Fuse - 3 set. - 1
No.
RYB LED Type Indication lamp assembly - Set - 1
4 x 300 Amp Electrolytic copper busbar with sleeve- 1 Set.
0-500 Volt Voltmeter - 1 Set.
0-300 Amp. Ammeter- 1 Set.
Out going
63 Amp TPN MCB - 11 No. Set 1
Rate in word :
Rate in Figure :
(iii) Air-Conditioning Bus Bar Unit :
Incoming
1250 Amp F.P MDO type Microprocessor relese , 50KA
ACB - 1 No.
RYB LED Type Indication lamp assembly - Set - 1
4 x 1600 Amp Electrolytic Aluminium Busbar - 1 Set.
0-500 Volt Voltmeter - 1 Set.
0-1600 Amp. Ammeter- 1 Set.
1600 / 5 CT - 3 Nos. Set 1
Rate in word :
Rate in Figure :
(iv) Out Door Light Panel :
Incoming
100 Amp contactor - 1 No.
Timer - 1 No
100 Amp TPN SFU - 1 No.
RYB LED Type Indication lamp assembly - Set - 1
4 x 125 Amp Electrolytic copper busbar - 1 Set.
Out going
32 Amp DP MCB - 8 No. Set 1
Rate in word :
Rate in Figure :
Page 41
Sl.No. Description Unit Qty. Rate Amount
(v) Stage Panel :
Incoming
125 Amp TPN SFU - 1 No.
RYB LED Type Indication lamp assembly - Set - 1
4 x 150 Amp Electrolytic copper busbar - 1 Set. Set 1
Rate in word :
Rate in Figure :
(vi) kitchen Panel :
Incoming
125 Amp TPN SFU - 1 No.
RYB LED Type Indication lamp assembly - Set - 1
4 x 150 Amp Electrolytic copper busbar - 1 Set.
0-500 Volt Voltmeter - 1 Set.
0-300 Amp. Ammeter- 1 Set.
Out going
63 Amp TPN MCB - 5 No.
32 Amp TPN MCB - 4 No. Set 1
Rate in word :
Rate in Figure :
7 Supply, delivery, installation, testing and commissioning
using company made Board and cover making good the
damages caused complete as per direction of Engineer-in-
Charge / Consultant .
(i) Light Distribution Board
MCB Distribution board 6 way three phase, neutral, double
door acrylic cover, 6 way DB with ELCB incomer and TB,
complete with MCB's.
Incoming :
63 Amp. Four Pole ELCB (overload, short ckt and earth
leakage protection (30mA)). - 1 No.
Outgoing :
10 Amp. SP MCB - 12 Nos. Set. 14
Rate in word :
Rate in Figure :
(ii) Power Distribution Board
MCB Distribution board 6 way three phase, neutral, double
door acrylic cover, 6 way DB with ELCB incomer and TB,
complete with MCB's.
Incoming :
63 Amp. Four Pole ELCB (overload, short ckt and earth
leakage protection(30mA)). - 1 No.
Page 42
Sl.No. Description Unit Qty. Rate Amount
Outgoing :
25 Amp. SP MCB - 12 Nos. Set. 8
Rate in word :
Rate in Figure :
(iii) Kitchen Distribution Board :
MCB Distribution board 6 way three phase, neutral, double
door acrylic cover, 6 way DB with ELCB incomer and TB,
complete with MCB's.
Incoming :
63 Amp. Four Pole ELCB (overload, short ckt and earth
leakage protection(30mA)). - 1 No.
Outgoing :
25 Amp. SP MCB - 9 Nos.
25 Amp. SP MCB - 3 Nos. Set. 1
Rate in word :
Rate in Figure :
8 Supply of all required materials and recessed (concealed
and separate from electrical condut) wiring with the following
sizes telephone wires and including the fixing of junction box
and distribution box and complete with all respect as per the
instruction of Engineer-in-charge or Consultant.
2 pairs telephone cable (0.5 tinned copper conductor PVC
insulated). Mtr. 245
Rate in word :
Rate in Figure :
9 Supply of all required material and fixing of phone socket,
modular box and complete with all respect as per the
instruction of Engineer-in-charge or Consultant. No. 6
Rate in word :
Rate in Figure :
10 Supply of all required materials and installation and fixing of
T.V.outlet points and fixing of modular boxes, plates, screws
etc. inclusive of all other accessories and complete with all
respect as per the instruction of Engineer-in-charge or
Consultant. No. 2
Rate in word :
Rate in Figure :
11 Supply of all required materials and laying of RG 6 coaxil
cable inside the 25 mm PVC conduit pipe of IS : 9537 for
TV and making the necessary connecting to the TV points
and complete with all respect including supply of conduit
pipe, earthing component as per the direction of Engineer-
in-charge or Consultant. Mtr. 100
Rate in word :
Rate in Figure :
Page 43
Sl.No. Description Unit Qty. Rate Amount
12 Supply of all required materials and fixing of 20 pair D.P. box
for telephone. No. 1
Rate in word :
Rate in Figure :
13(i) Providing and fixing of lightening conductor final, made of 25
mm dia, 600 mm long, copper tube having four proung at
top, with 150 mm x 150 mm size 3 mm thick copper base
plate including holes etc. complete as required. No. 4
Rate in word :
Rate in Figure :
(ii) Providing and fixing of 20 mm x 3 mm thick G.I. strip on
parapet or surface of wall for lightening conductor as
required. Mtr. 220
Rate in word :
Rate in Figure :
14 Supply,installation and testing 450mm width X 62.5mm
depth X 2.0mm thick of preforted pre painted MS cable tray
with perforation not more than 17.5% in convenient section
jointed with connecters ,suspended from the ceiling MS
suspenders including bolts & nuts paintings etc complete as
required Mtr. 1500
Rate in word :
Rate in Figure :
15 EARTHING
(i) Supply and installation including all connections of earth
electrode stations comprising of :
(a) 60 mm dia class - 'B' G.I. Pipe 3.0 mt. long.
(b) Digging of earth pit, placing of G.I. Pipe in the pit and filling
up of the same with a mixture of 150 kg. Salt 50 kg. of
charcoal and rest with good clay earth all firmly compact into
the pit as per I.S. : 3043.
(c) 30 cm. at the top portion at the pipe having a G.I. Hinges
shall be enclosed in a brick work chamber built up to 10 cm
below G.I. and upto 30 cm above G.I. Chamber which shall
have 450 mm x 450 mm inside dimension will have a G.I.
Hinge cover with the bare frame firmly grouted. No. 6
(ii) Providing and fixing of 50 x 5mm GI earth flat on surface or
recessed from earth pit to main bus bar unit and meter
board. Mtr. 70
(iii) Providing and fixing of 1 core x 16 sqmm aluminium
conductor on surface or recessed from main bus bar unit to
meter box / LDB. Mtr. 120
Rate in word :
Rate in Figure :
Total Internal Electrical Works : -
For M/s. RATH ARCHITECTONIC.
Page 44
Sl.No. Description Unit Qty. Rate Amount
* EXTERNAL ELECTRICAL WORKS : (Sec. - A)
16 Supply of all required material and laying, testing,
commissioning of following sizes 1.1 KV grade PVC
insulated armored aluminium power cable excavation of
cable trench of 750 mm deep in all kinds of soil, 150 mm
thick and filling, brick covering, back filling etc. including
laying in pre-laid Hume pipe/G.I. Pi;e and fixing only of cable
channel support as supplied and painted with red oxide and
aluminium paint including supply of cleats, supports,
fasteners and accessories etc. properly clamping of cable
and complete with all respect as per the instruction of
Enginner-in-charge or Consultant.
(a) 3½ x 630 sqmm Ar. Al cable. Mtr. 100
Rate in word :
Rate in Figure :
(b) 3 x 10 sqmm Ar. Al cable. Mtr. 350
Rate in word :
Rate in Figure :
(c) 3 x ½ x 300 sqmm Ar . Al . Cable Mtr 100
Rate in word :
Rate in Figure :
(d) 3 x ½ x50 sqmm Ar . Al . Cable Mtr 50
Rate in word :
Rate in Figure :
(e) 3 x ½ x70 sqmm Ar . Al . Cable Mtr 40
Rate in word :
Rate in Figure :
(f) 3 x ½ x35 sqmm Ar . Al . Cable Mtr 150
Rate in word :
Rate in Figure :
(g) 3 x ½ x 95 sqmm Ar . Al . Cable Mtr 50
Rate in word :
Rate in Figure :
17 Termination of cable of the following sizes by providing
cable glands lugs etc. and complete with all respect.
(a) 3½ x 630 sqmm Ar. Al cable. Set. 6
Rate in word :
Rate in Figure :
(b) 3 x 10 sqmm Ar. Al cable. Set. 20
Rate in word :
Rate in Figure :
(c) 3 x ½ x 300 sqmm Ar . Al . Cable Set. 2
Rate in word :
Rate in Figure :
Page 45
Sl.No. Description Unit Qty. Rate Amount
(d) 3 x ½ x50 sqmm Ar . Al . Cable Set. 2
Rate in word :
Rate in Figure :
(e) 3 x ½ x70 sqmm Ar . Al . Cable Set. 2
Rate in word :
Rate in Figure :
(f) 3 x ½ x35 sqmm Ar . Al . Cable Set. 4
Rate in word :
Rate in Figure :
(g) 3 x ½ x 95 sqmm Ar . Al . Cable Set. 4
Rate in word :
Rate in Figure :
18 EXTERNAL FITTING & FIXTURE : (Sec. - B)
(a) Supply, Installation, testing & commissioning of all required
materials and fixing of 125 W HPMV Lamp with fittings
mounted on 0.25 mtr., 40 mm G.I. Pipe grouted on ground
with R.C.C. base and provision for Junction box including
cable glanding and terminating as per the instruction of
Engineer-in-charge or Consultant. No. 2
Rate in word :
Rate in Figure :
(b) POST TOP LANTERN
Supply, Installation, testing and commissioning of all
required materials and errection of 3 mtr. long 60 mm dia
round G.I. Pipe grouted on ground with cutting the hole for
laying cable for cable glanding and terminating and painting
the pipe with primer and finish paint as required and R.C.C.
base foundation complete with all respect as per the
direction of Engineer-in-charge / Consultant. No. 20
Rate in word :
Rate in Figure :
19 JUNCTION BOX FOR OUT DOOR LIGHTING :
Supply, Installation, testing and commissioning of all
required material and mounting of 8" x 6" junction box with
separate water proof encloser box on R.C.C. coupon for out
door light having 1 No. 6 Amp. SP MCB with porcelin
connector and 1 No. neutral for controlling circuit and
complete with all respect as per the instruction of Engineer-
in-charge / Consultant. No. 22
Rate in word :
Rate in Figure :
Total External Electrical Works : -
Total Internal & External Electrical Works : -
B.O.Q FOR FIRE FIGHTING WORK
Page 46
Sl.No. Description Unit Qty. Rate Amount
A FIRE PUMP ROOM EQUIPMENT
Supply, erection, testing & commissioning of electrical motor
driven Main Hydrant Pump of centrifugal horizontal end
suction back pull out type with gland packing and capable to
deliver 2280 LPM at 70 MWC .The pump shall be coupled to
TEFC motor of suitable HP & speed and complete set shall
1 mounted on common base frame . The quoted rate shall Nos. 1
includes providing & fixing of coupling, coupling
gaurd.matching flanges for suction & delivery side,
Foundation bolts and RCC foundation as recommended by
manufacturer etc. RCC Foundation will be done by the civil
agency
Rate in word :
Rate in Figure :
Supply, installation, testing & commissioning of diesel
Engine driven common stand by pump, horizontal
centrifugal end suction back pull out type with gland packing
and capable to deliver 2280 at 70 MWC. The pump shall
coupled to suitable HP of Diesel engine radiator water
cooled type and mounted on common base frame, two sets
of Batteries & battery leads with stand, Fuel tank (For 6 Hrs.
2 running and filled fully) with stand &Fuel piping etc. The Nos. 1
quoted rate shall includes coupling, coupling guard, and
other standard accessories,RCC foundation (as
recommended by manufacturer) and foundation bolts, etc,
complete., RCC Foundation will be done by the civil agency.
The rate inclusive of all material, transportation etc. for
complete delivery at site or as per the direction of
P.M.C/NLUO
Rate in word :
Rate in Figure :
Supply, erection, testing & commissioning of electrical motor
driven Jockey pump of centrifugal horizontal end suction
type with gland packing .bronze impeller and capable to
deliver 180 LPM at 70 MWC.The pump shall be coupled to
TEFC motor of suitable HP & speed and complete set shall
mounted on common base frame. The quoted rate shall
3 Nos. 1
includes providing & fixing of coupling, coupling
gaurd.matching flanges for suction & delivery side,
Foundation bolts and RCC foundation as recommended by
manufacturer etc. The rate inclusive of all material,
transportation etc. for complete delivery at site or as per the
direction of P.M.C/NLUO
Rate in word :
Rate in Figure :
Fabricating & Supply, installing, testing and commissioning
of compartmentalized common control panel for Electrical
motor driven main pump, jockey pump and Diesel engine
4 No. 1
driven pumps. The rate inclusive of all material,
transportation etc. for complete delivery at site or as per the
direction of P.M.C/NLUO
Rate in word :
Rate in Figure :
Page 47
Sl.No. Description Unit Qty. Rate Amount
5 1100 V GRADE POWER / CONTROL CABLES
Supplying, laying, testing & commissioning of FRLS.PVC
outer sheathe, steel armoured, aluminium / copper
conductor, 1100v grade power cables with glands etc.The
cables shall be laid in tray on walls/ floor etc. as required.
The minimum size of the cables shall as mentioned below.
The rate inclusive of all material, transportation etc. for
complete delivery at site or as per the direction of
P.M.C/NLUO
a 3.5 C x 70 Sq.mm aluminum for main pumps Rmt 45
Rate in word :
Rate in Figure :
b 4C x 16 Sq. mm. Aluminum Jockey pump. Rmt 25
Rate in word :
Rate in Figure :
c 12C x 2.5 Sq. mm. aluminum Diesel engines Rmt 30
Rate in word :
Rate in Figure :
d 2C x 2.5 Sq. mm copper armoured for Instrumentation Rmt 50
Rate in word :
Rate in Figure :
CABLE TRAY
Supplying and fixing of ladder type G.l.sheet cable tray with
neccessory angle iron suspension supports, anchor
fasteners etc. complete, to line and levels. Maximum height
6 of suspension shall not exceed 500 mm.Size of the tray Rmt 20
shall be 40x 300 x 40mm.The rate inclusive of all material,
transportation etc. for complete delivery at site or as per the
direction of P.M.C/NLUO
Rate in word :
Rate in Figure :
Supplying and fixing of ladder type G.l.sheet cable tray with
neccessory angle iron suspension supports, anchor
fasteners etc. complete, to line and levels. Maximum height
7 of suspension shall not exceed 500 mm.Size of the tray Rmt 20
shall be 40x 150 x 40mm. The rate inclusive of all material,
transportation etc. for complete delivery at site or as per the
direction of P.M.C/NLUO
Rate in word :
Rate in Figure :
Page 48
Sl.No. Description Unit Qty. Rate Amount
Supply and laying of G.I. Earthing strips of 50mm x 6mm
thick, strip shall be run on floor / ceiling / walls, from the
equipment to the nearest Earth pit with neccessory
8 accessories as required. ( Earth pit shall be executed by Rmt 30
other agencies). The rate inclusive of all material,
transportation etc. for complete delivery at site or as per the
direction of P.M.C/NLUO
Rate in word :
Rate in Figure :
Supply and laying G.I. Earthing strips of 25mm x 3mm thick,
strip shall be run on floor / ceiling / walls, from the
equipment to the nearest Earth pit with neccessory
9 accessories as required. ( Earth pit shall be executed by Rmt 30
other agencies). The rate inclusive of all material,
transportation etc. for complete delivery at site or as per the
direction of P.M.C/NLUO
Rate in word :
Rate in Figure :
Supplying, installing, testing and commissioning of G.I.
Pipes confirming to IS 3589,6mm thick, with painting,
suitable type of supports, anchorl fasteners, bolts nuts (
Galvanized), clamps, "U" bolts, malleable specials such as
Reducers.Tees, elbows, flanges. Including cutting, Welding,
10
fixing in / on walls, ceiling by using suitable supports etc.
complete. structural supports are measured as seperate line
item. The rate inclusive of all material, transportation etc. for
complete delivery at site or as per the direction of
P.M.C/NLUO
Rate in word :
Rate in Figure :
a 200mm nominal dia Rmt 24
Rate in word :
Rate in Figure :
Supplying, installing, testing and commissioning of G.I.
Pipes confirming to IS 1239 Pt -1 Heavy(class C) grade with
painting, suitable type of supports, anchor fasteners, bolts
nuts ( Galvanised), clamps, "U" bolts, malleable specials
such as Reducers.Tees, elbows, flanges. Including cutting,
11
Welding, fixing in / on walls, ceiling by using suitable
supports etc. complete. structural supports are measured as
seperate line item. The rate inclusive of all material,
transportation etc. for complete delivery at site or as per the
direction of P.M.C/NLUO
a 150mm nominal dia Rmt 36
Rate in word :
Rate in Figure :
b 100mm nominal dia Rmt 6
Rate in word :
Rate in Figure :
c 80mm nominal dia Rmt 9
Rate in word :
Page 49
Sl.No. Description Unit Qty. Rate Amount
Rate in Figure :
d 25mm nominal dia Rmt 48
Rate in word :
Rate in Figure :
Supplying, installing and commissioning C.I., Flanged,
Rising spindle Gate Valve as per 14846 with.suitable
12 flanges, nuts, bolts, gaskets etc. complete.(PN10). The rate
inclusive of all material, transportation etc. for complete
delivery at site or as per the direction of P.M.C/NLUO
a 200mm nominal dia Nos. 4
Rate in word :
Rate in Figure :
b 100mm nominal dia Nos. 1
Rate in word :
Rate in Figure :
Supplying, installing, testing and commissioning of C.I. Non-
return valves as per IS:5312( PN 16) swing check type with
13 required flanges, nuts, bolts and gaskets etc. complete. The
rate inclusive of all material, transportation etc. for complete
delivery at site or as per the direction of P.M.C/NLUO
a 150 mm nominal dia Nos. 2
Rate in word :
Rate in Figure :
b 80 mm nominal dia Nos. 1
Rate in word :
Rate in Figure :
Supplying, Installing, testing and commissioning Cl butterfly
valves as per) BS 5155 ( PN 16) slim seal standard lever
operated type with required flanges, nuts, bolts etc.
14
complete. The rate inclusive of all material, transportation
etc. for complete delivery at site or as per the direction of
P.M.C/NLUO
a 150mm nominal dia (Lever Operated ) Nos 3
Rate in word :
Rate in Figure :
b 150mm nominal dia (Gear Operated ) Nos 2
Rate in word :
Rate in Figure :
c 80mm nominal dia (Lever Operated ) Nos 1
Rate in word :
Rate in Figure :
Page 50
Sl.No. Description Unit Qty. Rate Amount
Supplying, installing, testing and commissioning of Gun
metal chrome finished Ball valves with fittings of screwed
15 end type. The rate inclusive of all material, transportation
etc. for complete delivery at site or as per the direction of
P.M.C/NLUO
a 15mm dia. Nos. 5
Rate in word :
Rate in Figure :
b 25 mm dia Nos. 2
Rate in word :
Rate in Figure :
Supply and installation of Pressure switches of suitable
range for pump sets Fittings like unions / collar / reducers
16 etc. The rate inclusive of all material, transportation etc. for Set 3
complete delivery at site or as per the direction of
P.M.C/NLUO
Rate in word :
Rate in Figure :
Supply and installation of Pressure gauges of suitable range
for pump sets siphon, Fittings like unions / colors / reducers
17 etc. The rate inclusive of all material, transportation etc. for Set 2
complete delivery at site or as per the direction of
P.M.C/NLUO
Rate in word :
Rate in Figure :
Supplying, installing, testing and commissioning of diesel
engine exhaust piping of manufacturer's recommended size
of 150 dia, M.S. medium grade. Piping shall be complete
with supply and installation of exhaust pipe thermal
insulation lagging with mineral wool as per IS 3677 / 1973 to
withstand temperatures upto 750°C reinforced with chicken
18
mesh and cladded with aluminium sheet of 26 SWG and
50mm thick with 64 Kg/Cu. Mtr. Density, bird screen, long
bends, supports etc. Piping shall be done with flanged
connections to facilitate easy isolation. The rate inclusive of
all material, transportation etc. for complete delivery at site
or as per the direction of P.M.C/NLUO
150 mm dia M.S. Medium grade with mineral wool insulation
a Rmt 20
with aluminum sheeting.
Rate in word :
Rate in Figure :
b 150mm dia M.S. Medium grade shall be laid above ground. Rmt 20
Rate in word :
Rate in Figure :
19 Structural supports like MS angle, sheets, channel etc Kgs 800
Rate in word :
Rate in Figure :
Page 51
Sl.No. Description Unit Qty. Rate Amount
Suppling, installing, testing and commissioning of Flow
meter on test line of 150mm dia to measure up to 150 % of
20 rated pump flow. The rate inclusive of all material, Nos 1
transportation etc. for complete delivery at site or as per the
direction of P.M.C/NLUO
Rate in word :
Rate in Figure :
Supply, erection, testing and commissioning of Air cushion
tank of 300 mm dia. & 1000 mm hight with drain connection.
The rate shall be inclusive of accessories like 25mm dia Air
21 Nos 1
release valve & ball valve. The rate inclusive of all material,
transportation etc. for complete delivery at site or as per the
direction of P.M.C/NLUO
Rate in word :
Rate in Figure :
TOTAL PUMP ROOM TOTAL RS:
Rate in word :
Rate in Figure :
B HYDRANT SYSTEM
Supplying, installing, testing and commissioning of GI Pipes
confirming to IS 1239 Pt -1 Heavy grade(C class) with
painting, suitable type of supports like, anchor fasteners,
bolts nuts, clamps, "U" bolts, malleable specials such as
Reducers.Tees, elbows, flanges. Including cutting, Welding,
1
fixing in / on walls, ceiling by using suitable supports etc.
complete. structural supports are measured as seperate line
item The rate inclusive of all material, transportation etc. for
complete delivery at site or as per the direction of
P.M.C/NLUO
a 150mm nominal dia Rmt 64
Rate in word :
Rate in Figure :
b 100mm nominal dia Rmt 50
Rate in word :
Rate in Figure :
c 80mm nominal dia Rmt 7
Rate in word :
Rate in Figure :
Supplying, installing, testing and commissioning of G.I.
Pipes confirming to IS 1239 Pt - I Heavy grade(class C) with
suitable type of supports, malleable specials such as
Reducers.Tees, elbows, flanges. Including cutting, Welding
as per drawings. The rate quoted should e included with anti
2
corrosive treatment with 4 mm thick polymer corrosion
resistant tape as per IS 10221, overlap shall be 15mm
minimum. The rate inclusive of all material, transportation
etc. for complete delivery at site or as per the direction of
P.M.C/NLUO
a 150mm nominal dia Rmt 221
Rate in word :
Rate in Figure :
Page 52
Sl.No. Description Unit Qty. Rate Amount
b 100mm nominal dia Rmt 11
Rate in word :
Rate in Figure :
c 80mm nominal dia Rmt 5
Rate in word :
Rate in Figure :
Supplying, Installing, testing and commissioning Cl butterfly
valves as per BS 5155 (PN 16) slim seal standard lever
operated type with required flanges, nuts, bolts etc.
3
complete. The rate inclusive of all material, transportation
etc. for complete delivery at site or as per the direction of
P.M.C/NLUO
Rate in word :
Rate in Figure :
a 150mm nominal dia Nos. 5
Rate in word :
Rate in Figure :
Supplying, installing and commissioning of fire brigade inlet
inlet connection of 4 way with 4 nos. 63 mm dia. built - in
Gun metal Non- return valves instantaneous coupling type
arranged on 150 mm dia.Qouted rate shall be included with
4 Nos. 1
C.I, Butterfly valve, C.I. Non-return valve and M.S. cabinet of
suitable size with mounting supports etc. The rate inclusive
of all material, transportation etc. for complete delivery at
site or as per the direction of P.M.C/NLUO
Rate in word :
Rate in Figure :
Supplying, installing and commissioning of fire brigade inlet
inlet connection of 2 way with 2 nos. 63 mm dia. built - in
Gun metal Non- return valves instantaneous coupling type
arranged on 100 mm dia.Qouted rate shall be included with
5 Nos. 1
C.I, Butterfly valve, C.I. Non-return valve and M.S. cabinet of
suitable size with mounting supports etc. The rate inclusive
of all material, transportation etc. for complete delivery at
site or as per the direction of P.M.C/NLUO
Rate in word :
Rate in Figure :
Supplying, erecting and commissioning of Landing Hydrants
comprising of the following in the Fire duct; The rate
6
inclusive of all material, transportation etc. for complete
delivery at site or as per the direction of P.M.C/NLUO
Single headed hydrant valve as per IS 5290, made of
gunmetal with 63 mm dia instantaneous outlet of 80 mm dia
a Nos. 7
fanged inlet .Blank caps, chain and hand wheels etc
complete.
Rate in word :
Rate in Figure :
Page 53
Sl.No. Description Unit Qty. Rate Amount
2 lengths of 15 M long, 63mm dia RRL hose with
b instantaneous couplings and Hoses shall be stored in side Nos. 7
the hose cabinet.
Rate in word :
Rate in Figure :
c 1 no. Gun metal short branch pipe with nozzle. Nos. 7
Rate in word :
Rate in Figure :
Hose reel drum of swinging type with 19mm dia Rubber
d braided hose of 36.5M. length with gate valve (on upstream) Nos. 7
and Shut off nozzle, complete.
Rate in word :
Rate in Figure :
M.S. Hose cabinet stand mounted type fabricated out of
M.S. sheet of 16 swg. with glass fronted ( 4mm thick glass
with rubber beeding) door and size of the cabinet shall be
e 600mm x 750 mm x 250 mm Quoted rate shall be includes Nos. 7
suitable stand for mounting, all fasteners etc, and cabinet
shall be powder coated of approved colour both inside and
out side.
Rate in word :
Rate in Figure :
Supplying, installing, testing and commissioning of yard
hydrant comprising of the following, The rate inclusive of all
7
material, transportation etc. for complete delivery at site or
as per the direction of P.M.C/NLUO
Single headed hydrant valve as per IS 5290, made of
gunmetal with 63 mm dia instantaneous out & 80 mm dia
a Nos. 4
fanged inlet inlet.Blank cap , chain and hand wheel etc
complete.
Rate in word :
Rate in Figure :
2 lengths of 15 M long, 63mm dia RRL hose with
b instantaneous couplings and Hoses shall be stored in side Nos. 4
the hose cabinet.
Rate in word :
Rate in Figure :
c 1 no. Gun metal short branch pipe with nozzle. Nos. 4
Rate in word :
Rate in Figure :
M.S. Hose cabinet stand mounted type fabricated out of
M.S. sheet of 16 swg. with glass fronted ( 4mm thick glass
with rubber beeding) door and size of the cabinet shall be
d 600mm x 750 mm x 250 mm Quoted rate shall be includes Nos. 4
suitable stand for mounting, all fasteners etc, and cabinet
shall be powder coated of approved colour both inside and
out side.
Rate in word :
Rate in Figure :
Page 54
Sl.No. Description Unit Qty. Rate Amount
Supplying and fixing approved make 25mm dia. automatic
air release valve with ball valve& unions etc. complete. The
8 Nos. 3
rate inclusive of all material, transportation etc. for complete
delivery at site or as per the direction of P.M.C/NLUO
Rate in word :
Rate in Figure :
9 Structural supports like MS angle, sheets, channel etc Kgs 200
Rate in word :
Rate in Figure :
TOTAL FOR HYDRANT SYSTEM TOTAL RS:
Rate in word :
Rate in Figure :
C CIVIL WORKS
Excavation of trenches up to 1.5 mts.in depth,for laying
pipes upto 150mm dia.Including forming bottom surface to
required level, refilling the trenches with selected excavated
earth around th pipe in layers of 150mm thick, watering,
1
consolidating. Quoted price inclusive of disposing off /
carting away the surplus earth out side the site to a dump
yard acceptable local bodies or as directed by the site
engineer with alead of 300 mts. Etc. complete.
a Excavation in all kinds of soil Cum 315
Rate in word :
Rate in Figure :
Supply and installation of RCC hume pipes of 300 mm dia &
2 NP 2 Class with collars for road / below floor crossing of Fire Rmt 9
water pipes.
Rate in word :
Rate in Figure :
Supply & Construction of valve chamber with 230 mm Brick
masonry wall with best quality TM bricks & CM 1:4,on a
PCC 1:4;8 bed of 100 mm thick The wall shall be plastered
internally smooth in CM 1:3, water proofing as required and
b externally rough plastered with sponge finish, including Nos 3
curing. The chamber shall be provided with M.S. 6 / 8 mm
thick plate fabricated top cover in leaves with neccessory
hinges and locking arrangement. The size of the chamber
shall be 1200mm x 1200mm x1500mm in depth.
Rate in word :
Rate in Figure :
TOTAL FOR CIVIL WORKS
Rate in word :
Rate in Figure :
TOTAL Rs. A+B+C -
Rate in word :
Rate in Figure :
FOR M/s. RATH ARCHITECTONIC
Page 55