DIAGNOSTIC ULTRASOUND SYSTEM
Systems Data
No. MSDUS0025EA
OUTLINE
FamioTM 5 is a basic diagnostic ultrasound system for
black-and-white studies that is provided with a 10.4-inch
liquid crystal display monitor. All functions required for
examination are provided in a stylish unit that can easily be
set up immediately before examination is performed.
FEATURES
• Integrated design
The transducers, acoustic jelly, and recording device are
all integrated into a single compact unit. When the liquid
crystal display monitor is closed, the system can be stored
in a small space and easily taken out when needed.
• Quick start-up
After it has been plugged into a wall outlet, the system is
ready for use just 10 seconds after the power switch is
turned on.
• Easy operation
With Toshiba’s unique palm controller at the center, the
operating switches are laid out to ensure outstanding ease
of use. Image quality can be adjusted in a single operation
using the IP (Image Process) dial. The use of a color liq-
uid crystal display monitor permits subtle gray-scale gra-
dations to be easily observed with the B-color function.
• Data management
An HDD filing unit can be installed in the main unit, permit-
ting the images obtained in an examination to be retrieved
and viewed immediately. In addition, connection to an
external PC via Ethernet allows image data to be trans-
ferred directly to a folder in the PC. (Optional in some con-
figurations.)
SYSTEM MATRIX OF
No. Unit Model Name Remarks
1 Main Unit SSA-510A Main unit with 10.4-inch TFT display
<Options for main unit>
2 Transducer Selector UIPS-510A Adds a 2nd transducer port
3 Reference unit UJUR-320A
4 Foot switch UZFS-320A
5 Filing unit UIFU-510A Image filing system with HDD
6 CD-R unit UIFU-511A CD-R drive unit. UIFU-510A is required. (Cannot be mounted if the
UIFU-511A is installed.)
7 Image Memory UIIM-510A Image Memory up to 128 frames
8 Printer mounting kit UZRI-510A Kit for mounting the printer to the column
9 Printer mounting kit UZRI-511A Kit for mounting the printer underneath the operating panel.
(Cannot be mounted if the UIFU-511A is installed.)
10 VCR cables UZCA-510A Cables for connect VCR
2
MSDUS0025EA
Fre- Multi- Display
Scanning
No. Unit Model Name quency Frequencies Mode Application Remarks
Method
(MHz) (MHz) B/M
<Transducer Options>
11 Transducer
Convex transducers
PVG-366M Convex Abdomen
R60, 59° 3.75 5.0/3.7/3.0 쑗
PVG-381M Microconvex Cardiac
R14, 74° 3.75 5.0/3.7/3.0 쑗 Abdomen
PVG-681S Microconvex Neonatal head
R12, 83° 6.0 7.0/6.0/5.0 쑗 Cardiac
(Pediatric)
PVG-720S Convex Superficial
R150, 15° 7.5 8.0/7.5/5.0 쑗 Ob/Gyn
Peripheral vessels
Linear transducer
PLG-805S Linear Small parts
8.0 10/8.0/5.0 쑗
53 mm Peripheral vessels
Endocavity transducers
PVG-601V Convex Ob/Gyn
R12, 90° 6.0 7.0/6.0/5.0 쑗 (Endovaginal)
PVG-600S Convex Urology
R10, 106° (Endorectal)
6.0 7.0/6.0/5.0 쑗
Ob/Gyn
(Endovaginal)
Micro/Intraoperative
transducers
PVF-745V Convex Intraoperative, Micro-transducer,
R45, 36° 7.0 8.0/7.0/5.0 쑗 Superficial Vertical type
PVF-738F Convex Intraoperative, Micro-transducer,
R80, 27° 7.0 8.0/7.0/5.0 쑗 Superficial Finger type
PVF-738H Convex Intraoperative, Micro-transducer,
R80, 27° 7.0 8.0/7.0/5.0 쑗 Superficial Horizontal type
3
BLOCK CHART OF SYSTEMS
Famio 5
Main unit
SSA-510A
Transducer Selector
UIPS-510A
Reference unit
UJUR-320A
Foot switch
UZFS-320A
Filing unit
UIFU-510A
CD-R unit Printer mounting kit
UIFU-511A (*) UZRI-511A (*)
Image Memory
UIIM-510A
Printer mounting kit
UZRI-510A
VCR cables
UZCA-510A
*: Cannot be installed at the same time.
4
MSDUS0025EA
SPECIFICATIONS Display
• Format
B/M scan B/M scan: B (Single, Dual), B/M, M
• Scanning methods: Electronic convex
• Zoom: Available
Electronic linear
• Display position shift: Vertical direction
• B-mode electronic scan
• Memory size of DSC
Depth: Max. 20 cm
Image memory: 512 × 512 × 8 bit × 2 frames
Frame rate: Max. 75 frames/s
Graphic memory: 640 × 512 × 1 bit × 6 frames
Scanning lines: Max. 179 ultrasound lines
• Observation monitor: 10.4-inch LCD (Equivalent to 12"
• M-mode
CRT)
Channel: Single
• Character display
Scroll speed: 1, 2, 4, 8 s/screen
– Hospital name: 38 characters
• Focusing
– ID information: 18 characters
Electronic scan
– Comment 1 area: 21 characters
Transmission: 4 steps
– Image area: 58 characters × 30 lines
Reception: Twin Progressive Dynamic
– Auto data: Date, hr/min/s, depth, transduc-
Focusing
er frequency, frame rate*, scan
• Gain adjustment
direction display, gain, image
Gain: 62 dB to 100 dB
processing, and measured val-
(2 dB steps)
ues. MI/TI value
STC: 6-step sliding VRs
(0 to 18 cm) * The frame rate is displayed only when German is the selected
language.
• Image processing
– Persistence: OFF/1/2/3/4/5/6/7 • Image reversal: Left-Right, Up-Down
– Postprocessing: Linear/1/2 • Color palette
– Dynamic range: 60/65/70 dB – Function: Displays ultrasound tomographic
– Sampling processing images in color
(B-mode): OFF/ON – Color map: 8 types
– Sampling processing
(M-mode): OFF/1/2/3 Transducer connector
– Multifrequency mode: PENE/NORM/RESO • Connector
• Matrix filter: 4 types Electronic transducer: 2 connectors (max.)
• Transmission (2nd connector requires optional
combination focus: 2 types kit UIPS-510A)
• Image memory
– Functions: Cine loop and frame advance Reference signal
– Memory capacity: Max. 128 frames • Reference signal: ECG
– Cine loop speed: × 1 (real-time), × 1/2, × 1/4 (Optional kit UJUR-320A)
– Frame-advance
playback: Available
– Conditions depending
on the display mode: Available for B-mode only
5
Measurement
Basic measurement Application measurement
B-mode Distance, LV (SI/BI/Bullet/Modified Simpson),
Area (trace/ellipse/rectangle/spline), RATIO (%S)
Histogram (same as above),
Profile,
Angle,
Circumference,
Volume,
Cross distance
Parallel distance
Hip joint
M-mode Distance, LV (CUBE/TEICHHOLZ/GIBSON),
Time, MV,
Slope, AO
M-HR
• Obstetric calculations Peripherals
(OB adviser): This function provides data for • VCR Sony SVO-9500MD
determining fetal growth based Panasonic AG-MD830
on the measurement of fetal • B/W printer
size. Its features are as follows. Sony UP-895MD
– Applicable to twin Mitsubishi P91W, P93W
pregnancy TP-8010
– Applicable to various
authors' charts: 16 items (max.) Compliance with standards
– Trend graph: Quadruple display available • General
• Report IEC60601-1 (1988), Amd. 1 (1991), Amd. 2 (1995)
– Item: Application measurement • Particular
– Average: Average of three measurements IEC60601-1-2-37 (2001), Amd. 1 (2004)
– Comment: 30 + 60 characters • Acoustic Power
• User programmable Information for Manufacturers Seeking Marketing
measurement: 2 items available Clearance of Diagnostic Ultrasound Systems and
• Input/Output Transducers (1997) (FDA guidance)
– Input: VCR, ECG, Foot switch • Electromagnetic Compatibility (EMC)
– Output: VCR, External video, External IEC60601-1-2 (2001)
Monitor RS-232C
Image Filing (UIFU-510A required)
• Capacity
• Recording format
– JPEG
• Data output
– Ether net output
– CD-R (UIFU-511A required)
6
MSDUS0025EA
DIMENSIONS, MASS, AND POWER CONSUMPTION
External Dimensions mm (in) Mass kg (lb) Power Consumption
Unit Model Name
(approx.) (VA) (approx.)
Width Height Depth
Main Unit SSA-510A 450 1,215 595 45 680 (max.)
(Famio 5) (17.7) (47.8) (23.4) (99)
7
MSDUS0025EA
TOSHIBA MEDICAL SYSTEMS CORPORATION
http://www.toshibamedicalsystems.com
©Toshiba Medical Systems Corporation 2004 all rights reserved.
Design and specifications subject to change without notice.
2004-12 TME/KI
"Made for Life" and Famio are trademarks of Toshiba Medical Systems Corporation. Toshiba Medical Systems Corporation meets Toshiba Medical Systems Corporation Nasu operations meets