Ulazni podaci - Konstrukcija
Izometrija
Setovi greda
Set: 1    Presek: HOP [] 60x40x3, Fiktivna ekscentricnost
                                                        Mat.          A1         A2            A3         I1         I2         I3
                       2                             1 - Çeliku    5.410e-4   3.600e-4      2.400e-4   2.839e-7   1.273e-7   2.417e-7
         6
                          T              3
                               0.3
                                          [cm]
Tower - 3D Model Builder 6.0                                                                                                            Radimpex - www.radimpex.rs
Set: 2    Presek: HOP [] 40x40x2.5, Fiktivna ekscentricnost
                                                        Mat.         A1         A2            A3         I1         I2         I3
                                                     1 - Çeliku   3.580e-4   2.000e-4      2.000e-4   1.318e-7   7.780e-8   7.780e-8
         4
                          T
                               0.25
                                          [cm]
                                                                              Izometrija
Tower - 3D Model Builder 6.0                                                                                                           Radimpex - www.radimpex.rs
                                                         Ulazni podaci - Opterecenje
Lista slucajeva opterecenja
   No                          Titulli   pX [kN]     pY [kN]     pZ [kN]
    1      stalno (g)                         0.00        0.00        -7.73            5   Komb.: I+II       0.00    0.00         -11.60
    2      sneg                               0.00        0.00        -3.87            6   Komb.: I+III      0.00    0.00          -9.18
    3      vetar                              0.00        0.00        -1.45            7   Komb.: I+II+III   0.00    0.00         -13.05
    4      Komb.: I                           0.00        0.00        -7.73
                                                                    Opt. 1: stalno (g)
                                                                                   9
                                                                              p=0.6
                                                                        Ram: H_1
Tower - 3D Model Builder 6.0                                                                                        Radimpex - www.radimpex.rs
                               Opt. 1: stalno (g)
                                          7
                                     p=1.3
                                  Ram: H_3
                               Opt. 1: stalno (g)
                                          9
                                     p=0.6
                                  Ram: H_2
Tower - 3D Model Builder 6.0                        Radimpex - www.radimpex.rs
                               Opt. 1: stalno (g)
                                     p=0.97
                                  Ram: V_1
                               Opt. 1: stalno (g)
                                     p=0.97
                                  Ram: V_2
Tower - 3D Model Builder 6.0                        Radimpex - www.radimpex.rs
                               Opt. 2: sneg
                                       7
                                  p=0.3
                                Ram: H_1
                               Opt. 2: sneg
                                       3
                                  p=0.7
                                Ram: H_3
Tower - 3D Model Builder 6.0                  Radimpex - www.radimpex.rs
                               Opt. 2: sneg
                                       7
                                  p=0.3
                                Ram: H_2
                               Opt. 2: sneg
                                  p=0.52
                                Ram: V_1
Tower - 3D Model Builder 6.0                  Radimpex - www.radimpex.rs
                               Opt. 2: sneg
                                  p=0.52
                                Ram: V_2
                               Opt. 3: vetar
                                       4
                                  p=0.1
                                Ram: H_1
Tower - 3D Model Builder 6.0                   Radimpex - www.radimpex.rs
                               Opt. 3: vetar
                                       7
                                  p=0.2
                                Ram: H_3
                               Opt. 3: vetar
                                       4
                                  p=0.1
                                Ram: H_2
Tower - 3D Model Builder 6.0                   Radimpex - www.radimpex.rs
                               Opt. 3: vetar
                                  p=0.20
                                Ram: V_1
                               Opt. 3: vetar
                                  p=0.20
                                Ram: V_2
Tower - 3D Model Builder 6.0                   Radimpex - www.radimpex.rs
                                                              Dimenzionisanje (celik)
Merodavno opterecenje - @2@EUROCODE
   No                          Slucajevi opterecenja
    1      stalno (g)                                                            No              Kombinacije opterecenja
    2      sneg                                                                   4   I                                                          +
    3      vetar                                                                  5   I+II                                                       +
                                                                                  6   I+III                                                      +
                                                                                  7   I+II+III                                                   +
Kontrola napona - @2@EUROCODE
                        Opis           LC         σ           τ          σu
                                               [kN/cm2]    [kN/cm2]   [kN/cm2]
Set 1: HOP [] 60x40x3
(2 - 7)                                 4          4.849      0.330      4.883
                                        5          7.339      0.500      7.390
                                        6          5.783      0.394      5.823
                                        7          8.272      0.564      8.330
Kontrola napona - @2@EUROCODE
                        Opis           LC         σ           τ          σu
                                               [kN/cm2]    [kN/cm2]   [kN/cm2]
Set 1: HOP [] 60x40x3
(2 - 6)                                 4          2.484      0.060      2.486
                                        5          3.713      0.086      3.716
                                        6          2.945      0.069      2.947
                                        7          4.174      0.095      4.177
Tower - 3D Model Builder 6.0                                                                                               Radimpex - www.radimpex.rs