1. Safety instructions
?The power output voltage may still have 220V or 120V even not connect to the mains power.
?For the battery cable or power cord replacement, please contact our service station or dealer to purchase,
in order to avoid fire caused by inadequate capacity or heat ignition.
?Do not place the battery or battery pack in the fire, which will injure due to explosion.
?Please do not open the UPS case as you will, there is risk of electric shock
?Do not touch the battery connection terminals. Battery loop and input voltage loop is without isolation,
which may cause high voltage risk between the battery terminal and ground.
?Do not connect to the equipment like hair dryer or electric heater, to ensure the safety for the UPS
Attention:
UPS has high voltage inside, for personal safety, please do not repair by yourself. If any questions, please
contact local service center or dealer.
2. Installation Instructions
?Open the UPS package, please check the enclosed accessories including a user manual, communication
cable, support feet, CD-ROM. The long-back model also includes the cable for connection to battery
bank.
?Check the UPS if any damage in transport. If find it’
s damaged or parts missing, do not power on, please
turn to the carrier and dealer.
?To determine whether this UPS is the model you want to buy. Check the model name showed both on the
front panel and rear panel of UPS to confirm.
-2-
Note:
Please save the packaging box and packaging materials for future transport use. As heavy product, please
transit the UPS with care.
?The UPS installation environment must be with good ventilation, away from water, flammable gases and
corrosive entities.
?Do not lie down the UPS against the wall so that front and side panel air intake hole, rear panel air outtake
hole will be unobstructed.
?The peripheral environment temperature around the UPS should be within 0 ℃ ~ 40 ℃.
? If dismantling the machine at low temperatures, there may be condensation droplets, users can not install
or operate it before UPS completely got dry both inside and outside, otherwise there will be danger of
electric shock.
? Place the UPS near the mains socket to cut off AC mains without any delay at any emergent case.
Attention:
?Make sure the load behind the UPS is off when users connect the load to UPS, and then turn on the load
one by one later.
?Please connect the UPS with the socket which is over-current protected. Do not connect the UPS with the
socket which rated current is less than the Maximum input current of the UPS.
?All the power socket should be configured with earthling device for safety.
?UPS could be electrified or powered no matter the input power cable is tied or not, even when the UPS is
off. The only way to cut off the output is switching off the UPS, disable the EPO and disconnecting the
mains power supply.
?For all standard type UPS, it is advised to charge the battery over 8 hours before used. Once the AC
mains power energizes the UPS, it will automatically charge the battery. Without prior charging, UPS
output remains as usual but with shorter back-up time than normal.
?When connected to motor, display equipment, laser printer etc, UPS power selection should be based on
the startup power of the load which is usually twice as rated power.
2.3.1 The type of 120V (output could be 100V, 110V, 115V, 120V, 127V)
A、Standard model
2 3 4 2 11 7 8
5 6
R ESET
T
O
OUT
R ESET
R E S ET
EPO FUSE 250VAC3 5A
RESET
T
SLOT
TEL/MODEM/FAX
INTELLIGENT SLOT
O
+
ET
R ES
INTELLIGENT SLOT
RS232
EXT.BATTERY
INPUT OUTPUT
RS232
24VDC 40A
EPO
USB
INTELLIGENT
FUSE 125VAC,15A
RESET L N N L
+
EXT.BATTERY
USB
72VDC 40A
-
IN
-
9 1 10 8 7 9 10 6 5 4
B、Long-run model
-3-
9 2 3 4 7
2 3 4 5 6
ON
INTELLIGENT SLOT
R E S ET
EPO
T
O
+
ET
R ES
INTELLIGENT SLOT
RS232
EXT.BATTERY
RS232
24VDC 40A
FUSE 125VAC,15A
RESET
EPO
USB
USB INPUT OUTPUT OFF
L N L N
-
IN OUT
INPUT
OUTPUT SOCKET
TEL/MODEM/FAX
11 5 8 6
9 1 10 8 7
9 9
2 10 3 4 6
OUT
R ES
ET
T
DC OUTPUT DC OUTPUT
O
R
E S ET
RS232
TEL/MODEM/FAX
INPUT OUTPUT
FUSE 125VAC,35A
RESET L N N L
USB
+ 72VDC - + 72VDC -
IN
EPO
INTELLIGENT
+ 72VDC 40A - OUTPUT SOCKET SLOT
EXT.BATTERY
9 11 8 5 7
2.3.2 The type of 220V (output could be 208V, 210V, 220V, 230V, 240V)
A、Standard model
2 4 5 6 8 3 7 1 2
INTELLIGENT SLOT
R ESE T RE SET
IN
EPO
T
T
O
O
+
R ESET R ES ET
RS232
EXT.BATTERY
INTELLIGENT SLOT
24VDC 40A
TEL/MODEM/FAX
RS232
OUTPUT SOCKET
OUT
IN OUT
+ --
EPO
USB
INPUT TEL/MODEM/FAX 48VDC 40A
EXT.BATTERY
OUTPUT SOCKET
9 1 10 3 8 7 6 5 4 10 9
9 2 3 4 7
8 3 7 1 2 ON
INTELLIGENT SLOT
INTELLIGENT SLOT
E
RE S T
IN
RS232
T
O
R ES ET
EPO
TEL/MODEM/FAX
USB
INPUT FUSE 250VAC,20A
RESET INPUT OUTPUT OFF
L N L N
RS232
OUT
EPO
USB
+ -
USB
72VDC 40A
EXT.BATTERY
OUTPUT SOCKET
6 5 4 10 9 11 5 8 6
B、Long-run model
2 1 4 6
2 4 5 6
R ESE T
OUT
R ESET
T
EPO
O
T
RE T
O
+
R ESET SE
RS232
RS232
EXT.BATTERY
TEL/MODEM/FAX
INTELLIGENT SLOT
24VDC 40A
FUSE 250VAC,15A INPUT
FUSE 250VAC,8A RESET
RESET USB
USB
-
OUTPUT SOCKET
IN
IN OUT EPO
INTELLIGENT
INPUT TEL/MODEM/FAX + 48VDC 40A- SLOT
EXT.BATTERY
OUTPUT SOCKET
9 1 10 3 8 7 9 10 8 5 7
-4-
9 2 3 4 7
2 1 4 6
ON
INTELLIGENT SLOT
R ESET
OUT
T
RS232
O
R ESET
RS232
TEL/MODEM/FAX
USB
EPO
FUSE 250VAC,20A INPUT
RESET INPUT OUTPUT
USB
OFF
L N L N
EPO
IN
INTELLIGENT
+ 72VDC 40A- SLOT
EXT.BATTERY
OUTPUT SOCKET
9 10 8 3 5 7 11 5 8 6
Note: Diagrams take the type of 0.9PF for example, the type of 0.8PF is similar. Due to the technology
upgrading and development, goods and diagrams might have some differences.
Over Current Battery
Protector
OUT
ESE T
R
ON
T
O
T R
Over Current
ESE
FUSE 125VAC,20A
INPUT OUTPUT
/MODEM/
RESET
Protector
L N N L
IN
+ EXT.BATTERY
48VDC 40A - OUTPUT SOCKET INPUT OUTPUT
OFF
L N L N
Battery
Input output
LOAD
Input output
?One end of battery cable is for UPS terminals while the other end with triple cables is for battery terminals.
-5-
Correct installation procedure is highly vital or else probable electric shock will arise. Users are strictly
required to follow the below procedure.
?Connect battery in correct way and make sure the total battery voltage is available for UPS.
?Correctly connect the long battery cable to battery terminals first, red wire is to positive plate while black is
to negative. If users connect the UPS first, electric shock or other danger could not be avoided.
?Before connecting load after UPS, users should supply main power to UPS and energize it.
?Connect long battery cable to UPS terminals with correct poles link (red is for “+”, black is for“-”), UPS will
start the charging work automatically.
+ - + -
E
RE S T
RED
O T
RE SET
FUSE 125VAC,20A
INPUT OUTPUT
+
RESET
L N N L BLACK
- + -
+EXT.BATTERY
48VDC 40A - OUTPUT
+ - + -
Battery
2.6 Installation
?UPS installation work should comply with local electrical standard and only can be done by professional
technician. 1KVA~3KVA units could use wall socket as input power connection.
?For all type UPS, it is advised to charge the battery over 8 hours before the first use. Once the AC mains
power energizes the UPS, it will charge the battery automatically. Without prior charging, UPS output
remains as usual but with shorter back up time than normal.
Installation steps:
1) Please take out two groups of support feet from package, assemble by embedding them with each
other as shown below.
2) Place the two support feet in parallel on horizontal surface, and then put the machine into two support
feet carefully. Make sure the main power is off when you move it.
3) It also can be placed horizontally without support feet if you like, please remember not to put the
machine upside down. Please lie it down carefully and make sure the main power is off.
-6-
4) Machine and battery pack, can be put together, as two ways are showed in the pictures below, the
battery pack should be put under the machine. The battery pack is heavy, be careful when you move it.
VAC
E
LIN
HZ
OUTPUT
25% 50% 75% 100%
ON/OFF ROTATE
TEST/MUTE
※ ON/OFF key ( + )
Press and hold this key for more than half a second to turn on/off the UPS.
※ TEST/MUTE key ( + )
Press and hold the key for more than 1 second in mains mode or economical mode: UPS runs the self-test
function.
-7-
Press and hold the key for more than 1 second in battery mode: UPS runs the mute function.
※ ROTATE key ( + )
Press and hold and for more than half a second (less than 2 seconds): Change the direction to
display items.
VAC
the picture.
HZ
OUTPUT
VAC
E
E
LIN
LIN
Press and hold
HZ
OUTPUT
keys for more than
25% 50% 75% 100%
half a second.
100% 75% 50% 25%
TEST/MUTE TEST/MUTE
After finishing that, the machine can be placed flat, as shown in the picture below.
E
LIN
※ INQUIRING key ( , )
Non-function setting mode:
1) Press and hold or for more than half a second (less than 2 seconds): display the items orderly.
2) Press and hold for more than 2 seconds: Circularly and orderly display the items every 2 seconds,
when press and hold the key for some time again, it will turn to output status.
Function setting mode:
Press and hold the key for more than half a second (less than 2 seconds): Select the set option.
-8-
From left to right is inverter LED, battery LED, bypass LED and warning LED.
Warning red LED is on: UPS fault. For example: Overload beyond the allowed time, inverter fault, BUS fault,
over temperature fault etc.
Bypass yellow LED is on: UPS is alarming. For example: Bypass mode supply power and etc.
Battery yellow LED is on: UPS is alarming. For example: Battery mode supply power and etc.
Inverter green LED is on: UPS is normally powered by mains or ECO mode or battery mode.
PS: LED display detail in different mode is listed in 5 items.
i. The top diagram is for load, battery, fan, fault and buzzer icon. When UPS is over loaded, the load light
will blink as same as the battery light blinks when the capacity of battery gets low or battery is
disconnected. The left icon and right icon are for load and battery capacity indication, each grid of
which represents 25%.
ii. The fan icon is for fan working indication; when fan normally runs, the icon will display rotation; if the
fan is not connecting or faulty, the icon blinks;
iii. Press the mute button under the battery mode, buzzer icon will blink; it will disappear under other
cases.
iv. Fault icon will be on when UPS on fault mode, otherwise it will not.
75% 100%
Icon display area
VAC
E
LIN
Battery capacity
Load capacity
display area display area
HZ
75% 100%
Working mode
display area
Digital display area
A. Under none setting mode, it will display UPS output information when UPS normally runs in AC
mode; other information like input, battery, load and temperature will be showed after pressing the
inquiring key; Fault code will be told in fault mode.
-9-
B. Under setting mode, user could adjust different output voltage as well as activate ECO and BYPASS
mode by operating function setting key and inquiring keys.
After over 20 seconds, this area will display the working mode of the machine. e.g. STDBY(Standby Mode),
BYPASS(Bypass Mode), LINE(AC mode), BAT(Battery mode), BATT(Battery Self Test Mode ),
ECO(Economic Mode), SHUTDN(Shutdown Mode).
① When UPS is on line mode, press and hold the self-test/mute key for more than 1 second, LED light and
go out circularly and orderly. UPS comes to self-test mode and tests its status. It will exit automatically
after finishing testing, LED resume.
② When UPS is on battery mode, press and hold the self-test/mute key for more than 1 second, the
buzzer stops beeping. If you press and hold the self-test/mute key for one more second, it will restart to
beep again.
① Enter the setting interface. Press and hold the function setting key for more than 2 seconds, then
come to setting interface, the letters “ECO”will flash.
② Enter the ECO setting interface. Press and hold the function setting key for more than half a
second(less than 2 seconds), then come to setting interface of ECO, at this time, the letters “ECO”will
light for a long time. The “ON”(or OFF) will flash. Press and hold the inquiring key( , )for more
than half a second (less than 2 seconds) to determine whether the ECO function is used or not. If used,
the corresponding word is “ON”, if not, the word is “OFF”. It can be determined by yourself.
③ Confirm the ECO selecting interface. After selecting ON or OFF, press and hold the function setting
key for more than half a second (less than 2 seconds). Now, the ECO setting function is
completed and the “ON”or “OFF”will light without flash.
④ Exit from the setting interface. Press and hold function setting key for more than 2 seconds, exit
from the setting interface and turn to main interface.
E
LIN
LIN
① Enter the setting interface. Press and hold the function setting key for more than 2 seconds, then
come to setting interface, Press and hold the function setting key for more than half a second(less
than 2 seconds), select the function setting, choose the bypass output interface, at the moment, the
letters “BPS”will flash.
② Enter the Bypass output selecting interface. Press and hold the function setting key for more than
half a second(less than 2 seconds), then come to setting interface of BPS, at this time, the letters “BPS”
will light for a long time. The “ON”letter will flash. Press and hold the inquiring key( , )for more
than half a second (less than 2 seconds) to determine whether the BPS function is used or not. If used,
the corresponding word is “ON”, if not, the word is “OFF”. It can be determined by yourself.
③ Confirm the Bypass output selecting interface. After selecting ON or OFF, press and hold the function
setting key for more than half a second (less than 2 seconds), Now, the BPS setting function is
- 11 -
completed and the “ON”or “OFF”will light without flash.
④ Press and hold function setting key for more than 2 seconds, exit from the setting interface and
return to main interface.
⑤ After setting BPS as ON, when mains power plugged in without turning on the UPS or no mains power
plugged in, there is bypass output but no power down backup function.
VAC
E
LIN
E
LIN
HZ
INPUT 25% 50% 75% 100%
25% 50% 75% 100%
① Enter the setting interface. Press and hold the function setting key for more than 2 seconds, then
come to setting interface, Press and hold the inquiring key( , )for more than half a second(less
than 2 seconds), select the function setting, choose output voltage setting interface, at the moment, the
letters “OPU”will flash.
② Enter the output voltage selecting interface. Press and hold the function setting key for more than
half a second(less than 2 seconds), then come to setting interface of output voltage OPU, at this time,
the letters “OPU”will light for a long time. The numerical value below the OPU will flash. Press and hold
the inquiring key( , ) for more than half a second (less than 2 seconds), select the numerical
value in accordance with “OPU” function. The provided voltages are 100, 110V, 115V, 120V, 127V or
208V, 210V, 220V, 230V, 240V, you can choose anyone by yourself.
③ Confirm the output voltage selecting interface. After selecting numerical value, press and hold the
function setting , for more than half a second (less than 2 seconds). Now, the OPU setting function
is completed and the numerical value will light without flash.
④ Exit from the setting interface. Press and hold function setting key for more than half a second
(less than 2 seconds), exit from the setting interface and return to main interface.
- 12 -
25% 50% 75% 100% 25% 50% 75% 100%
E
E
LIN
LIN
25% 50% 75% 100% 25% 50% 75% 100%
① Enter the setting interface. Press and hold the function setting key for more than 2 seconds, then
come to setting interface, Press and hold the inquiring key( , )for more than half a second(less
than 2 seconds), select the function setting, choose battery voltage setting interface, at the moment, the
letters “bat”will flash.
② Enter the battery voltage selecting interface. Press and hold the function setting key for more than
half a second(less than 2 seconds), then come to setting interface of battery voltage, at this time, the
letters “bat”will light for a long time. The numerical value below the “bat”will flash. Press and hold the
inquiring key( , ) for more than half a second (less than 2 seconds), select the numerical value
in accordance with “battery”function. The provided voltages are 10V, 10.2V, 10.5V, numbers stand for
the voltage of each battery, you can choose anyone by yourself (The default is 10V), anyone has been
chosen, the machine will shutdown when its battery voltage achieve the voltage which you chose.
③ Confirm the battery voltage selecting interface. After selecting numerical value, press and hold the
function setting , for more than half a second (less than 2 seconds). Now, the battery setting
function is completed and the numerical value will light without flash.
④ Exit from the setting interface. Press and hold function setting key for more than half a second
(less than 2 seconds), exit from the setting interface and return to main interface.
Press and hold the inquiring key or for more than half a second(less than 2 seconds) to inquire
- 13 -
about items. The inquired items include input, battery, output, load, temperature. The displayed items on
LCD screen are showed as following:
Output:Display the output voltage and output frequency of the UPS. As the following picture shows, the
output voltage is 120V or 220V, the output frequency is 50Hz.
VAC VAC
E
LIN
LIN
HZ
HZ
OUTPUT
OUTPUT
25% 50% 75% 100% 75%
25% 50% 100%
Load: Display the numerical value of the active power (WATT) and apparent power (VA) of the load. For
example, as the following graphics shows: the WATT of the load is 800W or 900W, VA is 1000VA (when
disconnect load, it is a normal phenomenon to show a small numerical value of WATT and VA). or 900W
W W
E
E
LIN
LIN
KVA KVA
LOAD LOAD
Temperature: Display the maximum temperature of the components in the UPS. As the following picture
shows: the maximum temperature is 40℃.
TEMP
Input: Display the voltage and frequency of the input. As the following picture shows: the input voltage is
120V or 220V, input frequency is 50Hz.
- 14 -
25% 50% 75% 100% 25% 50% 75% 100%
VAC VAC
E
E
LIN
LIN
HZ HZ
INPUT INPUT
25% 50% 75% 100% 25% 50% 75% 100%
Battery: Display the voltage and capacity of the battery (determined by type). As the following picture
shows: the battery voltage is 24V or 36V, the capacity of battery is 100%(the capacity of battery is
approximately reckoned according to the battery voltage).
VDC VDC
E
E
LIN
LIN
% %
BATTERY BATTERY
Press and hold the inquiring key for more than 2 seconds, LCD begins to display the items circularly
and orderly which transfer to another every 2 seconds. Press and hold the key for some time again within
30s, it will return to output status.
Bypass yellow LED is on, the buzzer beeps once every 2 minutes. The warning red LED is on when
beeping, LCD displays are according to the exact load and battery capacity.
Turn to bypass mode under the following two conditions:
① Turn off the UPS on line mode while start the bypass output.
② Overload on line mode.
NOTE: When UPS is working on bypass mode, it has no back up function.
- 15 -
When input AC is in the range of working conditions, UPS will work on line mode.
When the AC power is low or unstable, UPS will turn to battery mode at once.
When the input mains meets the input range of the ECO mode and start the ECO function, the UPS will
works on ECO mode. If input AC exceeds the range of ECO several times in a row in a minute but stays in
inverter input range, UPS will work on AC inverting mode automatically.
At the moment, you can press the mute key to make the buzzer stop beeping temporarily to wait for
maintenance. You can also press the OFF key to shut down the UPS when confirm that there is no serious
fault.
Overload 50-54
Other 88
2 Battery mode
Battery voltage - One beep /
? ? ★
normal 4 sec
Warning for
One beep /
abnormal voltage of ? ★ ★
sec
battery
3 Bypass mode
Mains power –
One beep /
normal(under ? ★
2 mins
Bypass)
Mains power – high
One beep /
voltage warning ? ★
4 sec
(under Bypass)
- 17 -
Mains power – low
One beep /
voltage warning ? ★
4 sec
(under Bypass)
6. Trouble shooting
When the system runs in failure mode, the LCD will show as below:
- 18 -
Fault icon
LT
FAU
Fault code
Fault LED on, audible buzzer Please test the bus bar voltage or contact
Persistently alarm, the fault code Bus bar voltage fault the supplier.
is 00-14
Fault LED on, audible buzzer Please check the soft start up circuit,
persistently alarm, the fault code Soft start fault especially the soft start resistance or
is15-24 contact the supplier directly.
- 19 -
persistently alarm, the fault code is power normal or not, contact the supplier if
60-64 it is abnormal.
Please check if the input fuse is burnt.
Fault LED on, audible buzzer
Replace the old fuse and restart the UPS.
persistently alarm, the fault code is Input fuse fault
If failure remains, please contact the
65-69
supplier.
Please check whether the fans connect
Fault LED on, audible buzzer
well, is the fan plugged and is the fan
Persistently alarm, fan icon in the Fan fault
broken? If all above condition is OK,
LCD flickers
please contact the supplier.
Please press the power key more than 2
Pressing time too short
seconds to start the UPS.
The input connection is Please connect the input well, if the battery
UPS fail to start when operate not ready or voltage is too low, please disconnect the
“On”key UPS internal battery input and start the UPS with no-load.
disconnect
UPS internal system Please contact the supplier.
fault
Please keep the UPS battery recharging
Battery undercharge
more than 3 hours.
Please check the load level and
UPS overload
Back up time become short disconnect the noncritical devices,
Please change new battery, contact your
Battery maturing,
supplier to get the new battery and spare
capacity descend
parts.
UPS doesn’ t have any power go UPS input breaker Please reset the circuit breaker by manual.
through even main power on disconnects
Attention: When the output is short-circuited, the action of the protection of the UPS will show up.
Before turning off the UPS, please make sure to disconnect the entire load and cut off the AC mains power
supply, otherwise will make the AC input short-circuit.
8. Network communication
- 20 -
This series UPS offer intelligent network interface with a dedicated Ethernet card (optional accessory),
realizing network communication and management. For more information about this function, please turn
to our local distributor or service center.
Turn on Overload
- 21 -
AC Display screen repeat key
DC Battery
WOIB / 12 12 13
Weight (Kg) Standard
WIB 12 14.5 28 28 33 33 /
Battery pack / 17 17 23 23 28
*WOIB: Without Internal battery
*WIB: With Internal battery
Long 19 19
Battery pack 52 52
- 24 -
Appendix 6: Physical (The type of 120V)
Rated Capacity 1KVA 1.5KVA 2KVA 3KVA
Long 440×468×88
l TCP/IP
This model UPS can supply one Intelligent Slot at the rear panel, which was compatible with most of the
software and hardware all of the world, such as running HP open view,IBM net view,SUN net manager
and other operation system. UPS is with function login on internet supplying information of UPS status and
input power, and even capable of controlling UPS via net management system.
For more information, please turn to local supplier or distributor.
- 25 -