i 40 BS
Communication protocol Display unit Indicator for continuous weighing
WWW.PRECIAMOLEN.COM
• Instant throughput......................................................... R32 L Control • FSC (Field Sequential Colour) segment technology
• Average throughput .................................................... R32 L Zero • Configurable 7 colour backlighting
• Speed ......................................................................................... R32 LPartial reset • Weight display on 7 x 25 mm high characters Field of application Front panel
• Overall total ......................................................................... R32 L Overall • 10 x 8 mm high character text area
reset • Field bus metrological and activity indicator The i 40 BS weight indicator is designed to measure the flow
• Partial total ........................................................................... R32 LBatch reset • High viewing angle and contrast rates of any bulk product, without capacity limit. It integrates a
• Status ........................................................................................ E32 L Batch • Selectable French or English bilingual messages weight measuring card and an acquisition card of the belt or 7
printing screw conveyor speed.
• Minimum threshold ...................................................... R32 L/E
• Maximum threshold ..................................................... R32 L/E Keyboard Different housing versions allow installing the indicator on a table
9 8
top, a panel mounting or a din rail mounting.
• Material ratio ...................................................................... E16 L/E ( 0 or 1 )
• Touch control keys.
• Control ..................................................................................... E16 L/E
Functionalities 10
WWW.PRECIAMOLEN.COM
Connector for optional card Metrological characteristics
It has a backlit display unit allowing displaying the following 1 6
2 3 4 5
• Up to 200,000 divisions except for legal metrology use. selectable information:
One option among the following:
• Sensitivity .............................................................................. 2 mV/V On the 7-segment 25 mm high main line
Profibus-DP • Minimum voltage division per division ....... 0.5 μV
• flow rate with selectable measuring unit: kg/h, kg/s, t/h or
• Load cell power supply ............................................. 5V lb/h.
Keyboard
DeviceNet • Minimum load cell impedance ........................... 43 Ω • weight per meter with selectable measuring unit: kg/m or
1. Allows exiting a menu.
• Maximum load cell impedance .......................... 1245 Ω lb/m.
• Connection ........................................................................... 4/6 wires • belt speed with selectable measuring unit: m/s, m/min, ft/s 2. Allows accessing the user or engineer menu.
Ethernet Modbus-TCP
• Up to 100 measurements / second or rpm. 3. Validation (Enter) key.
EtherNet/IP • Cascadable digital filtering on 2 configurable levels
The overall or partial summation with selectable measuring 4. Allows starting a paper printing and navigation function.
unit on the 10-segment 8mm high secondary line: kg, t or lb.
4-20 mA or 0-10 V analogue output card Environmental characteristics When necessary, this second line alternately displays the 5. Allows accessing the application screen, the metrological
• Galvanic isolation 1500 V RMS summation and a message depending on the operation in menu and the navigation function.
• Possible to read negative weight values in the 0-4 mA • Power supply* .................................................................. 9 to 30 V DC progress. 6. Allows a dynamic zeroing of the scale and the navigation
range • Maximum consumption: function.
• 1 analog output: Typical ....................................................................................... 1.4 W The i 40 BS electronics can also favourably replace some existing
- flow With 4-20 mA / 0-10 V option............................. 1.8 W electronics. Display
- speed With field bus option ................................................... 2,7 W The i 40 BS meets the basic requirements of its application 7. Display the flow rate, weight per metre or speed.
- weight/meter • Connections on spring loaded terminals domain:
• Operating temperature ............................................ -15 °C/ + 60 °C 8. Display the total or partial summation and the current fault or
Weighing
(at 80% relative humidity max., non-condensing) the current zero state alternately.
Digital input / output allocation • Storage temperature ................................................. - 20 °C / + 65 °C • Weight and speed measuring.
• Automatic or manual zero request. 9. Indicate the maximum flow rate reached.
(at 90% relative humidity, non-condensing)
2 digital inputs • Instant flow calculation. 10. Indicate the minimum flow rate reached.
• Speed pick up. • Average flow rate with adjustable time constant.
• Overall totalizer reset in HML Communication options • Partial and overall summations
• Partial totalizer reset. • Min/max threshold management on the flow rate value with Models available
USB port and/or RS 232 port
• Batch reset. displayed colour change
10/100Mb RJ 45 Ethernet port Stainless steel housing: i 40-SS BS
• Material ratio. Printing
• Zero request. μSD card Panel mounting housing: i 40-PM BS
Manual or automatic batch ticket printing.
• Batch printing. • Allows parameter backup / restore. DIN rail housing: i 40-DR BS
• Slippage check. • DSD data storage memory, 300,000 recordings, legal use Printing example:
• Weigher On.
Default communication
4 digital outputs.
Options RS232/485 port slave RTU Modbus
• Zero in progress
• Zero OK. • Internal power supply** .......................................... 90 - 230 V AC CanOpen bus
• Zero fault. • Allows connecting a d 20 remote display unit
• Maximum flow rate • Allows integrating an i 40 BS weight indicator into an i 410
• Minimum flow rate network
• Flow rate out of range.
• Remote counter reset timing
• Overall totalizer pulse Electrical certification
• Partial totalizer pulse
• Compliant with European Directive relative to Electromag-
* If 4-20 mA option: 22 V minimum . netic Compatibility.
04-55-01-1 FT B - 08/20106
** - i 40-SS BS housing.. • Compliant with European Directive relative to Low Voltage
equipments.
Your specialist Illustrations not contractual. Precia-Molen reserves the right to alter the characteristics of the equipment described in this brochure
• International certification: IEC-low tension (n°FR 638805 -
at any time.
n°FR 642888)
PRECIA-MOLEN Headquarters & Factory
BP 106 - 07000 Privas - France
Tel. 33 (0) 475 664 600
Fax 33 (0) 475 664 330
Email webmaster@preciamolen.com
RCS: 386 620 165 RCS Aubenas
Note: The list of the various applicable European Directives as well as the list of countries with an accreditation can be found in our International Product Guide ref. 99-02-01-1 FT.
Models available
i 40-SS BS housing version i 40-SS BS
Dimensions in mm
304L stainless steel housing
IP66 protection rating
180 ° swivel bracket
Weight 1.5 kg
Optional panel mounting kit:
mm
• Cut-out 270 2
0 mm x 165 mm
2 mm
0 mm
(max thickness 4 mm).
WWW.PRECIAMOLEN.COM
i 40-DR BS DIN rail version i 40-DR BS
Dimensions in mm
Omega 35mm DIN EN 50022
rail mounting
Metal housing
IP30 protection rating
Weight 450 g
i 40-PM BS panel mounting version i 40-PM BS
Dimensions en mm
Front panel in 304L stainless steel
Metal housing
IP54 protection rating
Overall IP30 protection rating
Weight 450 g
Cut-out for panel mounting:
mm 2 mm
• 153 2
0 mm x 95 mm 0 mm
(max thickness 5 mm).