i 35
Options Weighbridge indicator
WWW.PRECIAMOLEN.COM
; Traffic light management (up to 2 lights)
37138
• Light status display by colour.
• Traffic light type configuration: Incoming or outgoing.
d
• Light name configuration (on 4 characters). k
8LT1 *
* 8LT2
; Weighing authorisation according to the contact state (vehicle
positioning cell, key switch, etc.).
11564
• Configurable message. d
WWW.PRECIAMOLEN.COM
• Authorisation / Weight display (YES/NO). k
OFF-BRIDGE
; Panel mounting kit
Cut out template
For incoming and outgoing material on the weighbridge, the i 35 indicator, equipped with a simple, user-friendly and efficient
application software, can meet any totally autonomous weighing application.
Equipped with a ticket printer (sold separately), it is also able to communicate with the industrial PCs on the market and remote weight
displays through multiple connections in accordance with the legal metrology aspects.
Maximum partition thickness: 8 mm. Economical and innovative, it controls two weighbridge incoming and outgoing traffic lights locally. In addition, it is equipped with an
ingenious weighing locking system prohibiting the weighbridge's use outside working hours.
Its power allows it to supply up to 18 PRECIA MOLEN product line analog or digital load cells, thus allowing it to manage very long
bridges.
Typical application
04-52-05-1 FT - 11/2012
Your specialist Non contractual illustrations. Precia-Molen reserves the right to alter the characteristics of the equipment described in this brochure 1. Digital load cells
at any time.
2. Remote weight display
Head Office & Factory PRECIA-MOLEN 3. Ticket printer
BP 106 - 07000 Privas - France
Tel. 33 (0) 475 664 600
Fax 33 (0) 475 664 330
E-MAIL webmaster@preciamolen.com
RCS: 386 620 165 RCS Aubenas
General characteristics and functions Technical characteristics
Metrological characteristics Communication
• Class III IPFNA ; To the remote weight display, selectable:
• Single range ......................................................... 6000 e (ML)
• On PMNet network (from the junction box):
................................................. 30000 d (HML)
• 1 RS232/RS485 port;
• Dual range.............................................................. 2 x 3000, 2 x 6000 (ML)
• 1 CANopen bus (option).
• Sensitivity ............................................................................................. 2mV/V
• Minimum voltage step per step ........................................ 0.5µV ; Protocols
• Load cell power................................................................................. 5V • PM A+ slave, PM A+ master
• Minimum load cell impedance .......................................... 43 Ω • PM master D
• Maximum load cell impedance ......................................... 1245 Ω • RTU Modbus (Serial bus)
• 4/6 wire connection.
• Up to 100 measurements/second. Certification
WWW.PRECIAMOLEN.COM
• Cascadable digital filtering on 2 configurable levels
; Metrology
Weighing Test certificate issued by a notified body in accordance with
• Weight reading (up to 18 load cells). Directive 2009/23/CE for Non-Automatic Weighing
• Minimum threshold management. Instruments.
• Zero tracking. ; Electromagnetic Compatibility
• Single weighing with predetermined tare. Complying with the requirements of Directive 2004/108/CE.
• Single weighing with manual tare.
; Low Power
• Single weighing (gross weight) with last 30 weighing
storing. Complying with the requirements of Directive 2006/95/CE.
Power supply Environment
• Dual weighing (gross weight) with recall of one of the last
• Voltage/ Frequency....................................... 90-230 V AC/ 50-60 Hz • Service temperature
stored 30 single weighing (gross weight).
(regulated use) ................................................... - 10 °C / + 40 °C
• Recording 300,000 weight records on Data Storage Device
Inputs – outputs (at 80% max. relative humidity, non-condensing)
(DSD).
• Digital outputs • Service temperature
galvanically isolated ...................................... 48 V AC/DC - 100 mA (non-regulated use)....................................... - 15 °C / + 60 °C
Display
• Digital inputs (at 80% max. relative humidity, non-condensing)
• Innovative FSC-LCD (Field Sequential Colour) technology.
galvanically isolated ...................................... 8-30 V DC - 15 mA max. • Storage temperature................................... - 20 °C / + 65 °C
• High viewing angle.
(at 90% relative humidity, non-condensing)
• Adjustable contrast.
• Weight on 7 x 25mm high characters.
• Indications: Unit, stability, range. Examples of tickets
• Configurable background colour (choice of 7 colours) ; Single weighing ; Weighing with predetermined tare
• Real time clock (HH :MM :SS).
• Weighbridge description: 10 x 8mm characters.
Keyboard
• Touch control keys.
Housing
• Protection rating IP 66
• 304L stamped stainless steel construction.
• Includes a swivel bracket (180°) for tabletop or wall
installation.
• Reversible rear shell.
• Weight 1.5 Kg
; Dual weighing ; Weighing with tare
Settings
The indicator's metrological and functional settings can be made:
- Via the indicator's front panel;
- Via PC and internet browser.
Parameter backup/restore on µSD card (option) or PC disk.
Preventive maintenance help
• Overload counter (digital: load cell by load cell).
• Alert display on 3 levels according to the number of
weighings taken.