RUBIN MeiStream,
MeiStream Plus
                     Cold water
                     Applications
                     RUBIN MeiStream and MeiStream Plus water meters operate according to the turbine blade flow measuring principle and are
                     designed for high-volume water measurement. The complete modular and housing system covers all areas of water supply
                     management. Meters can be retrofitted with pulse and data interfaces for mobile or stationary remote measurement.
                     Features                                                          Your benefits
                     • Wide measuring range                                            • Your benefits
                     • Measuring units can be replaced                                 • Measuring both small and large volumes with one
                     • Universal installation (MeiStream)                                flowmeter
                     • High overload capacity                                          • MeiStream Plus is ideal for monitoring piping systems
                     • Can be retrofitted with non-reactive modules for                  and detecting pipe leaks
                       remote readings                                                 • One version with the advantages of both Woltman WP
                     • With MID approval                                                 and WS
                                                                                       • No straight inlet necessary
VD 1-300 e 10.2009
Range
                                              • Turbine meters with dry-type registers, IP 68
                                              • SVGW certification
                                              • The meter can be installed in horizontal, vertical or inclined positions. The meter
                                                head must, however, face upwards or to the side. The MeiStream Plus is for horizon-
                                                tal installation only.
                                              • Requires no inlet path
                                              • Powder-coated grey cast iron housing with flange connections acc. to EN 1092-1
                                              • Maximum temperature 50 °C
                                              • Nominal pressure PN 16
                                              • Replaceable measuring unit
                                              • For updating with non-reactive HRI modules or optoelectronic pulsers
RUBIN MeiStream
 Nominal diameter                 DN      mm         40          50          50          65 1)       65 1)      80          80
                                          inch       1 1/2       2           2           2 1/2       2 1/2      3           3
 Art. No.                                            94524       94525       94585       94526       94586      94527       94587
 Overload                         Q4      m3/h       60          90          90          120         120        200         200
 Nominal flowrate                 Q3      m3/h       40          50          50          70          70         120         120
 Transitional flowrate horizonal  Q2      m3/h       0.32        0.4         0.4         0.63        0.63       0.51        0.51
 Transitional flowrate vertical   Q2      m3/h       0.4         0.51        0.51        0.81        0.81       0.8         0.8
 Minimum flowrate horizontal      Q1      m3/h       0.2         0.15        0.15        0.2         0.2        0.2         0.2
 Minimum flowrate vertical        Q1      m3/h       0.25        0.28        0.28        0.4         0.4        0.5         0.5
 Starting flow at approx.                 m3/h       0.05        0.05        0.05        0.07        0.07       0.1         0.1
 Max. pressure loss               at Q3   bar        0.08        0.18        0.18        0.37        0.37       0.16        0.16
 Smallest readable volume                 litre      0.5         0.5         0.5         0.5         0.5        0.5         0.5
 Recording capacity                       mio. m3    1           1           1           1           1          1           1
 Data for MID-homologation
 Nominal flowrate                 Q3      m3/h       25          40          40          63          63         100         100
 Measuring range horizontal               R          125         160         160         160         160        315         315
 Measuring range vertical                 R          100         125         125         125         125        200         200
 Measuring range as shown on delivery     R          63          100         100         100         100        100         100
 Weight                                   kg         7.5         7.8         9.6         10.1        12.0       14.2        16.3
 Overall length
                                          L          220         200         270         200         300        225         300
                                          H          120         120         120         120         120        150         150
                          g
                                          h          69          73          73          85          85         95          95
                                          g          200         200         200         200         200        270         270
 H
 h
1) Flanges with 4 holes
 2
Nominal diameter                    DN       mm        100     100     125     150     150
                                             inch      4       4       5       6       6
Art. No.                                               94528   94588   94529   94530   94589
Overload                         Q4          m3/h      300     300     350     600     600
Nominal flowrate                 Q3          m3/h      230     230     250     450     450
Transitional flowrate horizonal  Q2          m3/h      0.81    0.81    1.02    1.6     1.6
Transitional flowrate vertical   Q2          m3/h      1.28    1.28    1.6     3.2     3.2
Minimum flowrate horizontal      Q1          m3/h      0.3     0.3     0.5     0.8     0.8
Minimum flowrate vertical        Q1          m3/h      0.5     0.5     1       1.6     1.6
Starting flow at approx.                     m3/h      0.11    0.11    0.15    0.3     0.3
Max. pressure loss               at Q3       bar       0.34    0.34    0.2     0.32    0.32
Smallest readable volume                     litre     0.5     0.5     0.5     5       5
Recording capacity                           mio. m3   1       1       1       10      10
Data for MID-homologation
Nominal flowrate                 Q3          m3/h      160     160     160     400     400
Measuring range horizontal                   R         315     315     250     400     400
Measuring range vertical                     R         200     200     160     200     200
Measuring range as shown on delivery         R         100     100     100     100     100
Weight                                       kg        18.2    20.2    20.7    35.9    44.2
Overall length
                                             L         250     360     250     300     500
                                             H         150     150     160     177     177
                                             h         105     105     118     135     135
                       g
                                             g         270     270     280     356     356
 H
 h
Available on request:
- Nominal pressure PN 40
- Non-ferrous metal version
- Version for use in explosion-proof areas
- Flanged version e.g. ANSI, JIS
                                                                                               3
RUBIN MeiStream Plus
 Nominal diameter                   DN       mm        40      50      50      65 1)   65 1)   80      80
                                             inch      1 1/2   2       2       2 1/2   2 1/2   3       3
 Art. No.                                              94534   94535   94590   94536   94591   94537   94592
 Overload                           Q4       m3/h      50      55      55      60      60      120     120
 Nominal flowrate                   Q3       m3/h      30      35      35      40      40      63      63
 Transitional flowrate horizonal    Q2       m3/h      0.13    0.13    013     0.16    0.16    0.25    0.25
 Minimum flowrate horizontal        Q1       m3/h      0.08    0.07    0.07    0.1     0.1     0.13    0.13
 Starting flow at approx.                    m3/h      0.03    0.03    0.03    0.04    0.04    0.04    0.04
 Max. pressure loss                 at Q3    bar       0.09    0.08    0.08    0.17    0.17    0.07    0.07
 Smallest readable volume                    litre     0.5     0.5     0.5     0.5     0.5     0.5     0.5
 Recording capacity                          mio. m3   1       1       1       1       1       1       1
 Data for MID-homologation
 Nominal flowrate                 Q3         m3/h      25      25      25      40      40      63      63
 Measuring range horizontal                  R         315     315     315     400     400     400     400
 Measuring range as shown on delivery        R         315     315     315     315     315     315     315
 Weight                                      kg        7.5     7.8     9.6     10.1    12.0    14.2    16.3
 Overall length
                                             L         220     200     270     200     300     225     300
                          g
                                             H         120     120     120     120     120     150     150
                                             h         69      73      73      85      85      95      95
 H
                                             g         200     200     200     200     200     270     270
 h
1) Flanges with 4 holes
 Nominal diameter                   DN       mm        100     100     150     150
                                             inch      4       4       6       6
 Art. No.                                              94538   94593   94539   94594
 Overload                         Q4         m3/h      160     160     400     400
 Nominal flowrate                 Q3         m3/h      100     100     250     250
 Transitional flowrate horizonal  Q2         m3/h      0.4     0.4     0.63    0.63
 Minimum flowrate horizontal      Q1         m3/h      0.2     0.2     0.35    0.35
 Starting flow at approx.                    m3/h      0.07    0.07    0.12    0.12
 Max. pressure loss               at Q3      bar       0.16    0.16    0.14    0.14
 Smallest readable volume                    litre     0.5     0.5     5       5
 Recording capacity                          mio. m3   1       1       10      10
 Data for MID-homologation
 Nominal flowrate                 Q3         m3/h      100     100     250     250
 Measuring range horizontal                  R         400     400     630     630
 Measuring range as shown on delivery        R         315     315     315     315
 Weight                                      kg        18.2    20.2    35.9    44.2
 Overall length
                                             L         250     360     300     500
                                             H         150     150     177     177
                                             h         105     105     135     135
                          g
                                             g         270     270     356     356
 H
 h
Available on request:
- Version for use in explosion-proof areas
 4
Roller counters
DN 40...125                                                     DN 150
                                     x 0,1                                                                  x1
                                        9 0 1                                                              9 0 1
                   m3
                                    8
                                    7
                                        6 5 4
                                                2
                                                3                               x10m3                  8
                                                                                                       7
                                                                                                           6 5 4
                                                                                                                   2
                                                                                                                   3
                             x 0,01                                                             x 0,1
                                 9 0 1                                                              9 0 1
             x 0,001         8           2                                      x 0,01          8           2
                 9 0 1       7           3                                                      7           3
         O
                                                                                    9 0 1
                                                                            O
                                 6 5 4                                                              6 5 4
      OPT
                                                                         OPT
             8           2                                                      8           2
             7           3                                                      7           3
                 6 5 4                                                              6 5 4
Pulsers
The Meistream / Meistream Plus large capacity water meters are designed to be used with non-reactive HR modules and optoelectronic
pulsers. Add-ons can also be retrofitted without affecting the metrological data.
HRI modules
                                                        • 2 programmable pulse outputs and M-Bus data interface to IEC870-5/
                                                          EN1434-3
                                                        • Non-reactive inductive tap with external manipulation detection
                                                        • Lifetime of battery approx. 12 years, external power supply via M-Bus
                                                          approx. 15 years
                                                        • Cable length 3 m
                                                        • Ambient temperature -10 - 60 °C, IP 68
                                                        • Forward/reverse flow recognition
                                                        • Pulse value, length and type selectable with MiniCom software
M-Bus output, data transmission:
- Meter reading
- Fabrication number
- Meter number with secondary address
- Monthly meter reading on any day selected
- Meter reading with current and previous year’s billing date selected
- Minimum and maximum flowrate with time and date
- Reverse flow volume with time and date
- Pipe breakage and leak detection with selectable limit value
- Detection of any attempt at external manipulation
Pulse outputs:
- Programmable as:
  Opto-OD (NAMUR to EN 60947-5-6), pulse width 6 ms or
  Reed-RD compatible, pulse width 32, 128 or 500 ms, max. 48 VDC, max. 0.2 A, max. 4 Watt
                                                                                                                                  5
The following pulse modes can be set:
 Pulse mode                         B1                            B2                            B3               B4               B5                B6
 Pulse output
 I1 (white)                         Balanced                      Forward                       Forwards and     Balanced         NAMUR pulses      NAMUR pulses with
                                    pulses 1)                     pulses                        reverse pulses   pulses 1)        with forward/     blackflow suppres-
                                                                                                                                  reverse           sion (OD-AM)
                                                                                                                                  recognition
 I2 (yellow)                        On = Alarm 2)                 Reverse                       On = Forwards    Off = Alarm 2)   Not used          Not used
                                                                  pulses                        flow
1) Reverse pulses are compensated by suppressing the identical number of forward pulses.
2) Can be assigned for pipe breakage, leakage detection, external interference and cable breakage.
 Type designation                                                 Version                                                                                      Art. No.
 HRI-Mei/B4/D100/T500                                             DN 40...125: Open collector, 100 litres /pulse, pulse length 500 ms                          80508
 HRI-Mei/B4/D1000/T500                                            DN 150: Open collector, 1000 litres/pulse, pulse length 500 ms                               80509
 HRI-Mei/B5/D10/T6                                                DN 40...125: NAMUR (EN 60947-5-6), 10 litres/pulse, pulse length 6 ms                        80510
 HRI-Mei/B5/D100/T6                                               DN 150: NAMUR (EN 60947-5-6), 100 litres/pulse, pulse length 6 ms                            80511
 HRI-Mei-CDL/D10/T6                                               DN 40...125: Forward/reverse pulse with plug for CDL data logger,                            80512
                                                                  10 litres/pulse, pulse length 6 ms
 HRI-Mei-CDL/D100/T6                                              DN 150: Forward/reverse pulse with plug for CDL data logger, 100 litres/pulse,               80513
                                                                  pulse length 6 ms
MiniCom software is required for changing set parameters.
The HRI-Mei pulser is available with the following parameters on request:
 Version                                                          DN 40...125                                      DN 150
 Open collector / NAMUR                                           0.01, 0.05, 0.1 or 1 m3/pulse                    0.1, 0.5, 1 or 10 m3/pulse
                                                                  pulse length 32, 128 or 500 ms                   pulse length 32, 128 or 500 ms
                                                                  pulse length NAMUR 6 ms                          pulse length NAMUR 6 ms
  6
Optoelectronic pulsers
                                                           •    IR reflex light barriers to EN 50227 as a plug-in version
                                                           •    Non-reactive optical tap
                                                           •    Cable length 3 m
                                                           •    Ambient temperature -10 - 70 °C, IP 68
Technical data:
- Power supply 8.2 VDC
- Switch current (actuated) ≤1.2 mA
- Quiescent current (non-contact) ≥2.1 mA
- Forwards and reverse flow detection is built in by means of an additional current threshold at 1.5 mA. With forward flow, the rising
  pulse edge thus has an additional current threshold of 1.5 mA. With reverse flow, the current threshold lies on the falling edge of the
  pulse.
  Forward flow:                             Reverse flow:
- Pulse length is dependent on the flowrate and at meter standstill a continuous pulse is possible.
Type designation                         Version                                                                               Art. No.
OD 01                                    Optoelectronic pulser, smaller pulse value                                            93750
OD 03                                    Optoelectronic pulser, larger pulse value                                             93752
Standard pulse values and frequencies
Nominal diameter                DN       mm             40           50           65          80           100         125     150
                                         inch           1 1/2        2            2 1/2       3            4           5       6
HRI-Mei modules
Pulse value                              litres/pulse 100            100          100         100          100         100     1000
Pulse length                             ms           500            500          500         500          500         500     500
OD pulser
OD 01                                    litres/pulse   1            1            1           1            1           1       10
Pulse frequency at Q4                    Hz             13.9         13.9         21.9        34.7         55.5        55.5    13.9
Pulse frequency at Q1                    Hz             0.035        0.035        0.055       0.055        0.055       0.089   0.014
OD 03                                    litres/pulse   10           10           10          10           10          10      100
                                                                                                                                          7
Frequency transmitters
                                             FM-1D/K
                                             • Frequency transmitter
                                             • Pulse/current transformer and flowrate indicator for water meters
                                             • The FM-1D/K is a microprocessor-controlled frequency transmitter with digital
                                               display. It converts pulses into a flow-proportional current to indicate flowrate with the
                                               following outputs:
                                              - Current output
                                              - Counting pulses
                                              - Illuminated digital display
                                             FM-2D/K
                                             • Frequency transmitter
                                             • Flowrate summation of two water meters
                                             • The FM-2D/K is a microprocessor-controlled frequency transmitter with two pulse
                                               outputs
                                             • It can be used for combining signals from two pulses with a flow direction signal
                                             • M-Bus output
Frequency transmitter                        FM-1D/K                                   FM-2D/K
Art. No.                                     93236                                     92390
Input
Universal input for pulser reed contact or   1                                         2
NAMUR to EN 50227
Input frequency range for 0/4...20 mA        0...0.1 to 0...1000Hz                     0...300 Hz, 0...150 Hz with
                                                                                       flow direction recognition
Maximum cable length.                        approx. 6 km                              approx. 6 km
Outputs
Current output 0...20 mA or 4...20 mA,       1                                         2
max. load 1 kOhm
Relay, NO contact, max. 48 VAC/DC 1 A,       1                                         2
potential-free
Optocoupler output, max. 30 V, 30 mA         -                                         2
M-Bus Output                                 -                                         1
Ambient temperature                          0...70 °C                                 0...70 °C
Protection type                              IP 40                                     IP 40
Supply voltage                               230 VAC or 24 VAC / VDC                   230 VAC or 24 VAC / VDC
Montage                                      35 mm standard rail                       35 mm standard rail
Dimensions                                   100 x 73 x 114 (B x H x D) mm             100 x 73 x 114 (B x H x D) mm
8
FM-1D/K
                                                                                       Alternative
                                                                                       24 V DC
                                                                                          or             Flowrate indicator
                                                            Power supply
                                                             230 V AC                  24 V AC
                                                                                                                          Pulse counter
                                                                                Grounding
                                                                                                                           1234567 8
                                                                                                                                              24 V
                                                                    L       N     PE    24 VAC/D C            +       -      12345678
                                                                                                                   FM-1D/K
                                                                        +                   -                              select
                                                                + Sensor -        U+
   RUBIN with OD 01
FM-2D/K
       Power supply              Forwards     Reverse                                                             Power supply
                                              flow                                                                230 V/AC          Power supply
       230 V/AC     Power supply flow
                                                               Flowrate                                           or 115 V/AC       24 VAC/DC    Forwards   Pulse counter
       or 115 V/AC 24 VAC/DC
                                                               indicator                                                                         flow
              Grounding
                                                                                                                             Grounding
                                                Direction
                                      Pulse
                                                            Earth
                                       Elektronischer
RUBIN with OD 01   RUBIN with OD 01    Saldierzähler
                                                                                                     RUBIN meitwin with OD 01
                                                                                                     Submeter with reed contact
                                                                                                                                                                            9
Installation notes
Nominal sizes: pipes, meters and pipe reducers
The choice of the nominal meter size should not automatically be based on the nominal size of the pipe. The decisive factor is the hig-
hest flowrate that occurs continuously in the pipe - this determines the nominal flowrate Qn of the meter.
                          < 8°                  < 8°
                                                                   AM066243a
Mounting height
RUBIN MeiStream / MeiStream Plus meters have exchangeable velocity measuring units which can be tested and calibrated independ-
ently of the housing. For this purpose, the old units are removed upwards. When designing the installation, it is important to ensure that
there is adequate space above the meter for removal.
Installation position
Meters must not be installed upside-down as then the metrological approval requirements will not be met.
Electrical installation
Electrical cables and installation must be carried out by a specialist in accordance with legal requirements.
 10
Measurement error limits
According to Directive OIML R 49
% 5
  3
                                      Error tolerances
  2
  -1
                                   Typical error curve
  -2
  -3
  -4
  -5
                      Q1   Q2                            Q3 Q4
                                                                 11
Pressure loss curves
RUBIN MeiStream
                                            DN 125
                                            DN 100
                                                         DN 150
                                    DN 50
                                    DN 65
                                    DN 40
                                            DN 80
   Pressure loss
                     Flow in m3/h
RUBIN MeiStream Plus
                                            DN 100
                                                     DN 150
                                            DN 80
                                    DN 40
                                    DN 50
                                    DN 65
                                                                                                               Modification rights reserved / Copyright © Aquametro AG
                                                                                                               Änderungen vorbehalten / Sous réserve de modifications
     Pressure loss
                     Flow in m3/h
DISTRIBUTOR:                                                      HEAD OFFICE:
                                                                  AQUAMETRO AG
                                                                  Ringstrasse 75
                                                                                                                                          A0 -10.2009
                                                                  CH-4106 Therwil
                                                                  Phone +41 61 725 11 22
                                                                  Fax +41 61 725 15 95
Contact, Adress and Stamp                                         info@aquametro.com       www.aquametro.com