TECHNICAL DATA
                                               Insulation PreTest
                                               Protect the installation. Avoid costly mistakes.
                                               The Fluke 1664 FC Installation Tester is the only installation with
                                               “Insulation PreTest,” which warns you about potentially serious and
                                               costly mistakes. If the tester detects that appliances are connected to
                                               the system during test, it will stop the insulation test and provide a
                                               visual and audible warning. This helps eliminate accidental damage to
                                               peripheral equipment and keeps your customers happy.
 The new Fluke 1660 Series Installation        Fluke Connect®, ShareLive™ calling and Fluke Cloud™
 Testers are the only installation testers
 that help prevent damage to connected
                                               storage
 appliances and also allow users to            Share from anywhere
 send test results wirelessly via smartphone
 directly from the field.                      Save time—eliminate data entry by wirelessly syncing measurements
                                               directly from your installation tester and share with your team using
                                               the Fluke Connect system. Having access to measurements simultane-
                                               ous at the inspection site and from the office or an off-site location
                                               enables faster decision making and real time collaboration between
                                               team members.
 HEAVY DUTY,
 SINGLE INPUT LINE CORD
 Guards against failures in the field.
 WARRANTY
 Three-year standard warranty.
Key product capabilities
The 1660 Series testers verify the safety of electrical                team. You can get feedback, suggestions and even
installations in domestic, commercial and industrial                   have work orders sent to your job site.
applications. They can ensure that fixed wiring is
safe and correctly installed to meet the requirements                  You can also save your test results to Fluke Cloud™
of IEC 60364 and all relevant local standards.                         storage. No more writing down data on paper with
                                                                       the possibility of transcription errors. Cloud storage
Fluke 1664 FC                                                          gives you a fast, secure and accurate way to storing
                                                                       all your test data and create test certificates with
The Fluke 1664 FC is the only installation tester that                 Fluke DMS.
protects connected appliances from damage during
insulation tests, and allows you to share your test
                                                                       Fluke 1663
results wirelessly by smartphone with coworkers
or customers. Fluke’s patented Insulation PreTest                      The ideal tester for professional trouble-shooters.
stops you from performing tests with appliances that                   This instrument is ideal for professional users–high-
are connected to the system during test. This helps                    end functionality, advanced measurement capability,
eliminate accidental damage and keeps your custom-                     yet it is still easy to use. Operation is intuitive and
ers happy.                                                             easily mastered by all levels of field workers.
In addition, the Fluke 1664 FC offers you the power                    Fluke 1662
of Fluke Connect. Now you can send test results
                                                                       A solid, basic installation tester. The Fluke 1662 gives
straight from your Fluke 1664 FC to your smartphone,
                                                                       you Fluke reliability, simple operation and all the
and transmit those results to other members of your
                                                                       testing power you need for basic installation testing.
Features by model
 Measurement function                                                                       1662         1663       1664 FC
 Insulation-PreTest™ safety function NEW                                                                                •
 Insulation at L-N, L-PE, N-PE inputs NEW                                                                               •
 Auto Test sequence NEW                                                                                                 •
 Loop and line resistance—mΩ resolution                                                                                 •
 Continuity at L-N, L-PE, N-PE inputs NEW                                                                  •            •
 Test smooth dc sensitive RCDs (Type B/B+)                                                                 •            •
 Earth resistance                                                                                          •            •
 Voltage trms (ac and dc) and frequency                                                       •            •            •
 Wiring polarity checker, detects broken PE and N wires                                       •            •            •
 Insulation resistance                                                                        •            •            •
 Continuity and resistance                                                                    •            •            •
 Measure motor windings with continuity test (@ 10 mA)                                        •            •            •
 Loop and line resistance                                                                     •            •            •
 Prospective Earth Fault Current (PEFC/IK)                                                    •            •            •
 Prospective Short-Circuit Current (PSC/IK)                                                   •            •            •
 RCD trip time                                                                                •            •            •
 RCD trip current (ramp test)                                                                 •            •            •
 Measures trip time and current for RCD type A and AC in one test                             •            •            •
 RCD variable test current                                                                    •            •            •
 Automatic RCD test sequence                                                                  •            •            •
 Phase sequence test                                                                          •            •            •
 Included Accessories
 Heavy duty mains cord with single input connector NEW                                          •             •          •
 Hard case                                                                                      •             •          •
 Remote control probe                                                                           •             •          •
 Zero adapter                                                                                   •             •          •
General specifications
 Specification                                               Characteristic
 Size                                                        10 cm (L) x 25 cm (W) x 12.5 cm (H)
 Weight (incl. batteries)                                    approx. 1.3 kg
 Battery size, quantity                                      1.5 V type AA (IEC LR6), 6 pcs.
 Sealing                                                     IP 40
 Safety                                                      Complies with IEC/EN61010-1, UL61010, ANSI/ISA –s82.02.01 and
                                                             CAN/CSA c22.2 No. 1010
 Overvoltage                                                 CAT III 500 V, CAT IV 300 V
 Performance                                                 EC/EN61557-1 to IEC/EN61557-7 and IEC/EN61557-10
Insulation pretest
 Insulation safety pretest                                                                Requires to connect the Tester to L, N and PE.
                                                                       All trademarks are the property of their respective owners. WiFi or cellular service required to share
                                                                       data. Smartphone, wireless service and data plan not included with purchase. First 5 GB of storage is
                                                                       free. Phone support details can be viewed at fluke.com/phones.
                                                                       Smartphone wireless service and data plan not included with purchase.
                                                                       Fluke Connect® is not available in all countries.
Fluke’s new two-pole testers are built with you                    •	 Detects voltage even with discharged
in mind. They give you the best combination of                        batteries. The tester can still detect the pres-
safety, ease-of-use and fast answers available                        ence of voltage (>50 V ac, >120 V dc) even
anywhere.                                                             with dead batteries, an important safety feature.
•	 CAT IV 600 V, CAT III 690 V safety rating.                         You should always use your two-pole tester with
   Fluke’s new family of two-pole testers comply                      working batteries, but for that rare time when
   with both regulation HSE GS 38 (tip caps) and                      your batteries fail in the field, it’s nice to know
   IEC EN 61243-3: 2010, the most recent and                          you still have this one indication of live voltage.
   applicable standards for this type of test                      •	 Improved probe docking for secure stor-
   equipment.                                                         age.When the probes are docked, the two-pole
•	 4 ways to detect                                                   tester is ready to use, with proper spacing for
   ac/dc voltage.                                                     instant testing on standard outlets. If you’ve ever
   Fluke two-pole                                                     been frustrated with wobbly probes that slowed
   testers make                                                       you down, you’ll appreciate Fluke’s rugged
   answers easy                                                       design.
   to understand,                                                  •	 Phase rotation indicator for 3-phase
   indicating voltage                                                 systems. Where three-phase power supplies
   four ways: A clear,                                                feed motors, drives and electrical systems, use
   instantly visible                                                  Fluke’s innovative three-phase rotation detection
   LED indicator,                                                     system to quickly determine phase sequence.
   a bright digital                                                   Ensure the system is wired correctly, without
   display of the mea-                                                reaching for another tool.
   surement value, an                                              •	 RCD functionality. Convenient two-button
   audible continuity                                                 controls allow you to draw more current from
   test, and vibration                                                the circuit under test and intentionally trip
   to give tactile feedback (vibration indicator on                   Residual-Current Devices (RCDs) remotely and
   T110, T130, T150). It’s your preference. Use the                   determine if they are wired correctly. A Quick
   most effective method for each situation.                          Start Guide covering the basics of RCD testing
•	 Backlit graduated scale and backlit indica-                        is included with the product.
   tors. Bright backlights ensure that the buttons                 •	 Display hold (T130, T150). Focus on placing
   and the indicators are visible under any lighting                  your probes, take the measurement, then read
   conditions—and you can easily see and under-                       the LC display.
   stand the answers.
                                                                   •	 Built in electric torch (T110, T130, T150).
•	 Vibration provides tactile feedback (T110,                         Light up dim testing environments at the touch
   T130, T150). Even when viewing the display                         of a button for faster, safer probing.
   or hearing the beeper is difficult, you’ll know
   voltage is present. This is especially useful in
   noisy environments, or when you can’t take
   your eyes off the probes.
•	 Audio on/off for testing in quiet areas.
   If you’re working in quiet surroundings, such
   as a medical or office setting, you don’t want
   to disturb people in the vicinity with noises.
   The tester’s acoustic alert switches on or off to
   fit your environment.
•	Never guess whether your batteries are in
   good working order. The low battery indica-
   tor gives you advance warning when they fall
   below proper working voltage.
General specifications
  Power requirement                     2-AAA batteries
  Net weight                            180 g (6.4 oz) (T90)
                                        280 g (9.9 oz) (T110. T130, T150)
  Size (LxWxH)                          23 cm x 6.5 cm x 3.8 cm (T90)
                                        26 cm x 7 cm x 3.8 cm (T110. T130, T150)
  Warranty                              2 years
  Country of origin                     Romania
Ordering information
FLUKE-T90	            Voltage/Continuity Tester
FLUKE-T110	           Voltage/Continuity Tester With Switchable Load
FLUKE-T130	           Voltage/Continuity Tester With LCD, Switchable Load
FLUKE-T150	           Voltage/Continuity Tester With LCD, Ohms, Switchable Load