COLLEGE OF ENGINEERING
CIVIL ENGINEERING DEPARTMENT
                                 Building System Design Activity Manual
                        ACTIVITY NO. 1: Design Criteria and Requirements
1.1. Program Outcomes (POs) Addressed by the Activity
     a) ability to function on multidisciplinary teams
     b) ability to communicate effectively
1.2. Activity Intended Learning Outcomes (AILOs)
     At the end of the activity, the students shall be able to:
     a) Familiarize with design criteria for building design
     b) Determine applicable standards specified in the National Building Code of the Philippines
     c) Apply architectural, structural, safety, sustainability, and sanitation design requirements in
        buildings
1.3. Aims of the Activity
     The aim of this activity is to introduce the codes, standards, and specification requirements as
     stipulated in the National Building Code of the Philippines being used in building system design.
1.4. Principle of the Activity
     Research on the following topics to familiarize yourself with the background of the activity:
     a) National Building Code (NBC)
     b) Building Design Criteria and Specifications
     c) Requirements for Buildings Design
                 Architectural
                 Structural
                 Safety
                 Sustainability
                 Sanitation
1.5. Procedures/Instruction
     The activity comprises of the following steps:
     A. Plans
        1. Assume that you are a construction firm. Come up with a name to your company as agreed by
           the group.
        2. Given a complete building design sample, draw your own building design as specified below:
            a. Architectural Plan
            b. Structural Plan
        3. Consider the standards and codes specified in the NBC for your assigned design project.
    B. Design Specifications
       1.Indicate all design specifications related to the structural and architectural plans of your
         project.
       2. Provide detailed summary of important specifications needed in completing the project.
                                                                          FO-ACAD-SDE-00X/20MAR2020/REV.0
     C. Design Requirements
        1. Provide the following compliance requirements for any project:
             Safety
             Sanitation/Environmental
             Sustainability/Technical Capacity
        2. These requirements can be borrowed from actual construction firms
        3. Provide company information, registration, and license to operate.
 1.6. Data and Discussion
     1.6.1. Principle of the Activity
Company Name:            AHJNR Company
Project Engineers:        Engr. Nicole Bermejo                         Engr. Helianiza Bustillo
                        Engr. Alys Marie Dela Cruz                     Engr. Raechell Navalta
                        Engr. Mistral Julian Haravata
     I.      SECTION 701: Occupancy Classified
               Buildings proposed for construction shall be identified according to their use or the
               character of its occupancy and shall be classified as follows:
                  Group A. Residential Dwellings
                  Group B - Residentials, Hotels and Apartments
                  Group C - Education and Recreation
                  Group D - Institutional
                  Group E - Business and Mercantile
                  Group F - Industrial
                  Group G - Storage and Hazardous
                  Group H - Assembly Other Than Group I
                  Group I - Assembly Occupant Load 1000 or More
                  Group J - Accessory
     II.     SECTION 704: Location of Property
                No Building shall be constructed unless it adjoins or has direct access to a public space
                  yard or street on at least one of its sides.
                For the purpose of this Section, the center line of an adjoining street or alley shall be
                  considered an adjacent property line.
                Eaves over required windows shall not be less than 750 millimeters from the side and
                  rear property lines.
     III.    SECTION 707: Maximum Height of Buildings
                The maximum height and number of storeys of every building shall be dependent upon
                 the character of occupancy and the type of construction as determined by the Secretary
                 considering population density, building bulk, widths of streets and car parking
                 requirements.
                                                                   Building Height Limit (BHL)
                 Character of Use or    Type of Building/         Number of        Meters        above
                     Occupancy              Structure             allowable               highest
                                                                storeys/floors            grade
                                                                    above
                                                              established grade
                   1. Residential      Residential 1 (R-1)             3                   10.0
                                       Residential 2 (R-2)
                                          a. Basic                     3                   10.0
                                          b. Maximum                   5                   15.0
                                       Residential 32 (R-3)
                                          a. Basic                     3                   10.0
                                          b. Maximum                  FO-ACAD-SDE-00X/20MAR2020/REV.0
                                                                      12                   36.0
                                  Residential 4 (R-
                                  4)/     Townhouses              3                    10.0
                                  (individual
                                  lots/units)
          The height shall be measured from the highest adjoining sidewalk or ground surface:
               Provided, that the height measured from the lowest adjoining surface shall not
                  exceed such maximum height by more than 3.00 meters:
               Except, that towers, spires, and steeples, erected as part of a building and not
                  used for habitation or storage are limited as to height only by structural design
                  if completely of incombustible materials, or may extend not to exceed 6.00
                  meters above the height limits for each occupancy group if of combustible
                  materials.
IV.    SECTION 801: Light and Ventilation
          Every building shall be designed, constructed, and equipped to provide adequate
            light and ventilation.
          All buildings shall face a street or public alley or a private street which has been
            duly approved.
          No building shall be altered nor arranged so as to reduce the size of any room or
            the relative area of windows to less than that provided for buildings under this Code.
          No building shall be enlarged so that the dimensions of the required court or yard
            would be less than that prescribed for such building.
V.     SECTION 805: Ceiling Heights
       a.) Habitable rooms provided with artificial ventilation shall have ceiling heights not less
           than 2.40 meters measured from the floor to the ceiling;
                Provided that for buildings of more than one (1) storey, the minimum ceiling
                   height of the first storey shall be 2.70 meters and that for the second story 2.40
                   meters and the succeeding stories shall have an unobstructed typical head-room
                   clearance of not less than 2.10 meters above the finished floor. Above-stated
                   rooms with natural ventilation shall have ceiling height of not less than 2.70
                   meters.
       b.) Mezzanine floors shall have a clear ceiling height not less than 1.80 meters above and
           below it.
VI.    SECTION 806: Size and Dimensions of Rooms
       Minimum sizes of rooms and their least horizontal dimensions shall
       be as follows:
           a) Rooms for Human Habitations. 6.00 square meters with at least dimensions of 2.00
           b) Kitchens. 3.00 square meters with at least dimension of 1.50 meters
           c) Bath and toilet. 1.20 square meters with at least dimension of 0.90 meters.
VII.   SECTION 808: Window Openings
       Shall be provided with a window or windows with a total free area of openings equal to at
       least ten percent of the floor area of room, and such window shall open directly to a court,
       yard, public street or alley, or open water courses.
VIII. SECTION 1001: General Requirements
         No part of any building or structure or any of its appendage shall project beyond
           the property line of the building site, except as provided in this Code.
         The projection of any structure or appendage over a public property shall be the
           distance measured horizontally from the property line to the outermost point of the
           projection.
                                             3
                                                                 FO-ACAD-SDE-00X/20MAR2020/REV.0
   IX.    SECTION 1003: Projection of Balconies and Appendages over Streets
          The clearance between the established grade of the street and/or sidewalk and the
          lowest under surface of any part of the balcony shall not be less than 3.00 meters.
   X.     SECTION 1007: Doors, Windows and the Like
          Doors, windows, and the like less than 2.40 meters above the pavement or groundline
          shall not, when fully opened or upon opening, project beyond the property line except
          fire exit doors.
   XI.    SECTION 1202: Excavation, Foundation and Retaining Walls
          The design and quality of materials used structurally in excavation, footings, and in
          foundations shall conform to accepted engineering practice.
   XII.   SECTION 1203: Veneer
          Veneer is a nonstructural facing of brick, concrete, tile, metal, plastic, glass, or other
          similar approved materials attached to a backing or structural component of the
          building for the purpose of ornamentation, protection, or enclosure that may be adhered,
          integrated, or anchored either on the interior or exterior of the building or structure.
   XIII. SECTION 1207: Stairs, Exits and Occupant Loads
         a.) Doors. The provisions herein shall apply to every exit door serving an area having an
             occupant load of more than ten (10), or serving hazardous rooms or areas.
                 Type of Lock or Latch. Exit door shall be openable from the inside without
                    the use of a key or any special knowledge or effort.
                 Width and Height. Every required exit doorway shall be of a size as to
                    permit the installation of a door not less than 900 millimeters in width and not
                    less than
                    2.0 meters in height.
1.6.2. Design Attachments/Illustrations (See attached)
        Attachment 1: Architectural Plan (Site Plan)
                                                                   FO-ACAD-SDE-00X/20MAR2020/REV.0
Attachment 2: Architectural Plan (Floor Plan)
                                                FO-ACAD-SDE-00X/20MAR2020/REV.0
Attachment 3: Architectural Plan (Tile Layout)
                                                 FO-ACAD-SDE-00X/20MAR2020/REV.0
Attachment 4: Architectural Plan (Elevation)
                                               FO-ACAD-SDE-00X/20MAR2020/REV.0
Attachment 5: Architectural Plan (Section)
Attachment 6: Architectural Plan (Ceiling Plan)
                                                  FO-ACAD-SDE-00X/20MAR2020/REV.0
Attachment 7: Architectural Plan (Schedule of doors and Windows)
                                                       FO-ACAD-SDE-00X/20MAR2020/REV.0
Attachment 8: Structural Plan
                                1
                                0
                                    FO-ACAD-SDE-00X/20MAR2020/REV.0
1
1
    FO-ACAD-SDE-00X/20MAR2020/REV.0
1
2
    FO-ACAD-SDE-00X/20MAR2020/REV.0
1.6.3. Observation
  I.    SECTION 701: Occupancy Classified
         Buildings proposed for construction shall be identified according to their use or the
         character of its occupancy therefore it is classified as Residential Dwellings (Group A)
         and it is a three-Unit Two Storey construction project that is to be constructed at 836
         Negros St. Balic Balic, Sampaloc, Manila.
  II.   SECTION 704: Location of Property
         In accordance with the National Building Code of the Philippines, No Building shall be
         constructed unless it adjoins or has direct access to a public space yard or street on at least
         one of its sides. Correspondingly the house has no fence blocking the street so it has clear
         access to a public space or street.
  III. SECTION 707: Maximum Height of Buildings
        In line with standards of the National Building Code of the Philippines, a residential
        building height limit should be 10 meters above the highest grade. The height of the plan
        we proposed is 9.65 meters, fits with the requirement of this section.
                                                 1
                                                 3
                                                                     FO-ACAD-SDE-00X/20MAR2020/REV.0
IV.   Light and Ventilation
      The location of the townhouse shows that it is facing a street creating the optimal flow of
      light and air.
V.    Ceiling Heights
      The total height measured from the ground floor finishing level to the tip of the concrete
      roof is 8.45 m. For the first floor of the townhouse, which has approximately 3 m height,
      the second floor, which has approximately 3 m height, and lastly, the roof deck has
      approximately 2.45 m height. The buildings' heights were acceptable to the requirement
      of NBC Section 805; to have a minimum of 2.70m for the first storey, 2.40m for the
      second storey, and 2.10m for the succeeding storeys.
VI.   Size and Dimension of Rooms
      The sizes and dimensions of the rooms such as the room for human habitations, kitchen,
      and bath and toilet as shown in the given table, all passed in the requirements of the NBC
      Section 806 to have a 6.00 sq. meters with a least dimension of 2.00 meters for the room
      of human habitation, 3.00 sq. meters with a least dimension of 1.50 meters for kitchen,
      and lastly, 1.20 sq. meters with a least dimension of 0.90 sq. meters for bath and toilet.
                                            1
                                            4
                                                               FO-ACAD-SDE-00X/20MAR2020/REV.0
                           DIMENSIONS    QUANTITY         FLOOR            TOTAL
                              (m2)                         AREA              (m2)
                                                            (m2)
First Floor:
Toilet and Bathroom        2.0 x 2.0        2                4               8
Living Area (left side)    3.1 x 5.5        1              17.05           17.05
Living Area (right side)   3.1 x 4.5        1              13.95           13.95
Dining area with           3.1 x 5.5        1              17.05           17.05
Kitchen
(left side)
Dining area with           3.1 x 4.5        1              13.95           13.95
Kitchen
(right side)
Second Floor:
Bedroom                    3.1 x 3.2        2               9.92           19.84
Master’s Bedroom           5.5 x 3.1        1              17.05           17.05
(left side)
Master’s Bedroom           4.5 x 3.1        1              13.95           13.95
(right side)
Toilet and Bathroom        2.0 x 2.01       1               4.02            4.02
(left side)
Toilet and Bathroom        2.0 x 1.425      1               2.85            2.85
(right side)
Roof Deck:
Toilet and Bathroom        2.0 x 2.01       1               4.02            4.02
(left side)
Toilet and Bathroom        2.0 x 1.425      1               2.85            2.85
(right side)
                                  1
                                  5
                                                FO-ACAD-SDE-00X/20MAR2020/REV.0
1
6
    FO-ACAD-SDE-00X/20MAR2020/REV.0
VII.   SECTION 808: Window Openings
       In accordance with the National Building Code of the Philippines, windows of the room
       are provided with a total floor area of 10 m and approximately 3 m for the window
       openings. All windows are disclosed in public compliance.
VIII. SECTION 1001: General Requirements
                                          1
                                          7
                                                            FO-ACAD-SDE-00X/20MAR2020/REV.0
      The proposed plan of the house has complied with all the requirements as stated on the
      National Building Code of the Philippines and shall not exceed to the maximum allowable
      space provided. Considering the parking space to ensure that no part of the house shall
      project beyond the property line.
IX.   SECTION 1003: Projection of Balconies and Appendages over Streets
      As provided with parking lot, the under surface of any openings of the house will not
      exceed to the property line leaving a thorough space between the house and an established
      grade of the street and/or sidewalk.
                                           1
                                           8
                                                              FO-ACAD-SDE-00X/20MAR2020/REV.0
X.    SECTION 1007: Doors, Windows and the Like
      In line with standards of the National Building Code of the Philippines, the doors,
      windows, and the like comply in less than 2.40 meters above the pavement or ground line.
      Correspondingly the main entrance of a two-story townhouse has a measure of 1.2 m in
      height above the ground line.
XI.   Excavation, Foundation and Retaining Walls
                                          1
                                          9
                                                             FO-ACAD-SDE-00X/20MAR2020/REV.0
       The construction quality and material used for the excavation foundation, and walls
       conforming to the NBC 1202. Therefore, those were assumed to be accepted relying on
       their soil bearing potential.
XII.   SECTION 1203: Veneer
       In detail, the plan for the townhouse used a brick accent wall to add depth and character to
       the house. Also, it will keep the house from being bland. A brick veneer is used only on
       the exterior of the townhouse. It is good to maintain simplicity and not get overboard.
XIII. Stairs, Exits and Occupant Loads
       The illustration clearly show that the main door is openable from the inside since it is a
                                             2
                                             0
                                                                 FO-ACAD-SDE-00X/20MAR2020/REV.0
              swing type of door, which conformed in the NBC; to have an exit door which is
              openable from the inside without the use of a keny or effort.
             Based on the illustration below, the main entry door has a width of 1.991 m and
              height of 4.181 m, which be eligible in the NBC Section 1207; to have a minimum
              0.9 m width and 2 m height.
1.6.4. Conclusion
       The Design Criteria and the Building Codes or standards acted as the guidelines when
       planning and creating a safe, sustainable and desirable living space or buildings. It served as
       like the backbone in the designing process where we take into consideration the standards to
       achieve an ideal and safe plan. In this activity we were able to familiarize ourselves with the
       building codes of different sections and learned how to work through and incorporate these
       criteria and standards in designing the building. We can further improve the plan by studying
       more these criteria and understanding more each plan/layout and learning how these work
       well with each other. By considering the standard specifications and incorporating it to the
       preference, we were able to come up with an ideal and desirable living space that takes into
       consideration the safety, sustainability and long-term
                                                2
                                                1
                                                                    FO-ACAD-SDE-00X/20MAR2020/REV.0