Control Panel Overview
Date: 2015-01-01
Time: 12:00:00
Dosing Pump DP-2
User’s manual
Jecod DP-2 dosing pump is an automatic dosing pump designed to enable
ESC
the addition of liquids to an aquarium at user defined times and volumes. Before
operation , please read the manual fully.
: Menu & confirm
ESC: Return back
↑: shift Up, plus
↓: shift down, minus.
←: shift left
ESC
→: shift right
Date and Time Setting
Company:Jecod Co.Ltd
Set New Date:
Address:TONGMAO INDUSTRIAL PARK, DONGSHENG TOWN,
2013-11-13
ZHONGSHAN CITY, GUANGDONG PROVINCE Press “ „to enter Menu, select“Set Date & Time”by
Tel.: +86-760-28136716/17/18 Fax: +86-760-28136725 pressing“↑” “↓”button. Press “←” “→”to shift between
E-Mail: info@jecod.com Website: www.jecod.com date fields. Increase/decrease by pressing“↑”“↓”button.
Set New Time: Pn Correct Fluid
12:00:00 100ml = 200
Press“ ”to save the data and move to clock setting screen, Calibration Method:Make sure pump tubing is primed with
press “←” “→”button to select the time digit. Press “↑” “↓” liquid first. Using a measuring cylinder( 100ml or larger), place
to increase/decrease digit. Press “ ” to save and return back the pump outlet tube into the measuring cylinder – make sure
to Main page the inlet tube is in liquid. Press "↑“ to start calibration. Once
100 mL has been dispensed, press "↑“ again to stop the pump.
Press” ” to save the calibration value.
Prime pump tube Repeat for all other pumps. press“ ESC“ after calibration of all
pumps to return to main menu.
Menu Mode:Pumps
12345678 Auto-Control setting
From the main menu, press either “←”or“→” button From main menu, press “ ” to enter setting menu. Press
to enter the manual mode. To select the required pump press “↑” “↓”button to select “Set Program”
,press“ " to select
either “←”or“→”. Press and hold “ “ to run the pump and the pump.
prime the tubing. Select Pump:
Before use, check each pump operation. Prime the tubing to
ensure the tubing is filled with liquid. Make sure that no air 12345678
bubbles are present in the tubing. Perform calibration. Pump selection:press“←” “→”to select the pump. Press
To achieve greatest precision, please keep the dosing pump “ ”to enter the number of doses per day setting.
horizontal. Pn Times Dosing:
For: 1 (1~24)
Flow rate calibration
From main page, Press“↑”or“↓”button to enter Calibration Doses per day:Choose from 1-24 times per day. Press “↑”
mode. Select the desired pump by pressing“←” or “→”and then “↓” to increase or decrease the number of doses .Press“ ”
pressing“ ” to enter the interval days setting.
the flow rate of each pump.
Pn Interval Days: 4, Do not disassemble the product.
For: 0 (0~30) Assembling drawing
Interval days - this sets the number of days between dosing - it can
be set in the range 0 -30. 0= dosing every day, 1 = dosing every other
day etc.
Press “↑”“↓” to increase or decrease the number of
days. Press “ ”to enter dosing volume setting
Press and pull the click
Pn Dosing Volume: strongly when disassemble
the grey card
Num: 1 -- 0010ml
Dosing Volume:The volume to be dosed. Press “←” “→”
to select the volume digit, press“↑”
“↓”to increase or decrease
(Max. setting is 9999ml). Press“ ” to enter the first dosing time
Loose the four
setting. Num“1” means 1st dosing period. click,dispart the
above & under
Pn Dosing Time: cover slightly
Num:1 -- 12:00
Dosing time set:Set the time the pump starts to dose. Press the lock click
strongly when disassemble
Press “←” “→” to choose the hour or minute. Press“↑” “↓”
to increase or decrease。Press“ ” to enter the next dosing
period volume setting. Repeat until each dosing period is set.
Repeat for each pump. When finished setting all pumps, press
ESC“ to return to main menu.
Warning Replace the rubber hose,Make
sure the position and
tightness of the hose please
1, For indoor use only. Avoid contact with moisture and humidity.
2, Do not use with corrosive liquids or liquids that can easily crystallise.
3, Before use, please prime the tubing with liquid via manual mode, and calibrate