ATTENTION
2
LEROY-SOMER INSTALLATION AND MAINTENANCE 3664 en - 01.2008 / c
1.1 - Standards and safety measures ....................4 4.1 - Safety measures ........................................... 8
3
LEROY-SOMER INSTALLATION AND MAINTENANCE 3664 en - 01.2008 / c
4
LEROY-SOMER INSTALLATION AND MAINTENANCE 3664 en - 01.2008 / c
2 - TECHNICAL CHARACTERISTICS
2.1 - Electrical characteristics
The PARTNER LSA 37 alternator is a machine without
sliprings, using auxiliary phase capacitor to provide the self
excitation (ACC system).
Interference suppression conforms with standard EN 55011,
group 1, class B.
ROTOR STATOR
U6 ( T4 ) Z1 ( T5 )
Yellow White
Diodes
Capacitor
Frame U5 ( T3 )
Black U2
U1 ( T1 )
Red
U1
U2 ( T2 ) Z2 ( T8 )
Green Brown
IM 1001: (B 34)
Two-bearing with SAE flange and standard cylindrical shaft
extension
5
LEROY-SOMER INSTALLATION AND MAINTENANCE 3664 en - 01.2008 / c
6
LEROY-SOMER INSTALLATION AND MAINTENANCE 3664 en - 01.2008 / c
U1 ( T1 )
U6 ( T4 )
U2 ( T2 )
U5 ( T3 )
U5 ( T3 ) U6 ( T4 )
U6.T4 U6.T4
AV U2.T2 AV U2.T2
AR AR
L1 L2 LOWER VOLTAGE L1 L2 HIGHER VOLTAGE
7
LEROY-SOMER INSTALLATION AND MAINTENANCE 3664 en - 01.2008 / c
ATTENTION
Do not use : trichlorethylene, perchlorethylene,
trichloroethane or any alkaline products.
8
LEROY-SOMER INSTALLATION AND MAINTENANCE 3664 en - 01.2008 / c
9
LEROY-SOMER INSTALLATION AND MAINTENANCE 3664 en - 01.2008 / c
Rd
During this procedure, make sure that the alternator is
disconnected from any external load.
- Unscrew the 6 cover fixing screws. A
- Remove the NDE shield Condensateurs
- Unsolder the wires on the diodes in order to read the
resistance of each winding.
Rd: discharging resistor (5000 ohms - 20 W)
The currents are indicated with ±10% tolerance
Capacitor (...µF-450V - 3000H)
50 Hz 220 V 60 Hz 240 V
2 poles µF I (A) µF I (A)
LSA 37 M7 70 4.8 80 7.2
LSA 37 M8 100 6.9 120 10.8
LSA 37 L6 130 9 160 14.5
Rotor
LSA 37 VL11 180 12.4 220 20
Resistances
(ohms) Main phase Auxiliary phase 4.5.5 - Weight tables
LSA 37 M7 0.37 0.5
Type Total weight (kg)
LSA 37 M8 0.4 0.6
LSA 37 M7 80
LSA 37 L6 0.5 0.7
LSA 37 M8 95
LSA 37 VL11 0.6 0.8
LSA 37 L6 100
LSA 37 VL11 120
4.5.3 - Checking the diode bridge
- Proceed in the same way as for reading the rotor resistance 4.6 - Dismantling, reassembly (see
by unsoldering a single side of the diodes.
A diode in good working order should allow the current to flow section 5)
only in the anode-to-cathode direction.
Anode A C Cathode
ATTENTION
Whilst being handled, the machine should remain
horizontal (rotor not locked when moved).
Check how much the machine weighs (see 4.5.5.) before
choosing the lifting tool. The choice of lifting hooks or
4.5.4 - Checking the capacitor handle should be determined by the shape of the lifting
rings.
10
LEROY-SOMER INSTALLATION AND MAINTENANCE 3664 en - 01.2008 / c
4.6.5 - Dismantling
4.6.5.1 - N.D.E. bearing replacing on single bearing
alternator
- Remove rotor (4) from stator (take care not to damage 1 2
windings and diodes)
- Extract bearing (70) with a bearing puller
4.6.8 - REASSEMBLY
Reverse procedure of disassembly. 5 6
(Check that the preloading wavy washer (79) is at the right
place in the N.D.E. bracket).
11
LEROY-SOMER INSTALLATION AND MAINTENANCE 3664 en - 01.2008 / c
12
LEROY-SOMER INSTALLATION AND MAINTENANCE 3664 en - 01.2008 / c
48
49
183
184 110
185
124
188
30
21
15
322
324
323
53
38
36
37
79
349
70
18
1
4
34
33
48
49
184
185 183
110
124
14
188
4
266
30
15
265
53
38
36
79
349
70
18
13
1
21
37
13
LEROY-SOMER INSTALLATION AND MAINTENANCE 3664 en - 01.2008 / c
48
49
184
183
124
110
185
349
188
22
60 36
33
21
30
410
411
284
53
38
37
79
70
18
1
4
15
34
14
LEROY-SOMER INSTALLATION AND MAINTENANCE 3664 en - 01.2008 / c
EC DECLARATION OF INCORPORATION
Concerns electric generators designed to be incorporated in machines subject to Directive no. 98/37/EC.
Herein declares that the electric generators in the PARTNER range (low voltage) and those series based on them
conform to the following standards and directives:
Low Voltage Directive no. 73/23/EC dated 19 February 1973, modified by Directive no. 93/68/EC
dated 22 July 1993
These generators are designed to be used in complete power generating sets which must comply with the
following standards and directives:
- EMC directive no. 89/336/EC modified by Directives nos. 92/31 EC dated 28 April 1992 and 93/68/EC
dated 22 July 1993, concerning the intrinsic characteristics of emission and immunity levels.
WARNING:
The abovementioned generators must not be commissioned until the machines in which they are to be
incorporated have been declared as conforming to Directives nos. 98/37/EC and 89/336 EC and any other
directives that may be applicable.
15
LEROY-SOMER 16015 ANGOULÊME CEDEX - FRANCE
RCS ANGOULÊME N° B 671 820 223
S.A. au capital de 62 779 000 ¤
www.leroy-somer.com