0% found this document useful (0 votes)
87 views17 pages

Axial Loaded Footing Design Guide

The document outlines the design calculations for axial loaded footings for square, rectangular, and eccentric columns, detailing loads, dimensions, and material specifications. It includes checks for one-way and two-way shear, as well as reinforcement requirements for each footing type. The calculations confirm that the designs meet safety and structural integrity standards.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
87 views17 pages

Axial Loaded Footing Design Guide

The document outlines the design calculations for axial loaded footings for square, rectangular, and eccentric columns, detailing loads, dimensions, and material specifications. It includes checks for one-way and two-way shear, as well as reinforcement requirements for each footing type. The calculations confirm that the designs meet safety and structural integrity standards.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 17

DESIGN OF AXIAL LOADED FOOTING FOR SQUARE COLUMN

load on column = 300 Kn


size of column = B= 0.23 D 0.23 m
SBC = 200 Kn/m2
Fck = 20 Kn/m2
Fy = 415 Kn/m2
load on footing = 330 Kn
area = 1.65 m2
size of footing = B= 1.3 D= 1.3 m
area provided = 1.69 m2
net upward pressure = 292.89940828 kn/m2
critical sec length = 0.535 m
B.M = 54.492836538 knm
depth of footing = 123.23767329 mm
taken depth = 277.28476491 mm
cover = 50
dia of bar = 10 ast. = 78.53981634
overall depth = 342.5
pt% = 0.1561337986 %
Ast req = 562.81580731 mm2
no. of steel = 8
Ast prov. = 628.31853072 mm2
pt% prov = 0.1743052659
clear spacing = 137.75 OK
check for onewayshear =
Vu = 98.130031822 kn
Tau v = 0.2722278661
Tau c (choose from table) = 0.29 OK
=
check for two way shear =
Vu = 419.62590107 kn
Tau v = 0.7458035866
Tau c(take from table) = 1.1180339887
kc = 1 for square column
Tau c'(kc*Tau c) = 1.1180339887
=
check (Tau v<Tau c') = ok
=
summary =

bar dia(mmno of bar spacing(mm)


along x dir 10 8 137.75
along z dir 10 8 137.75
mm2
Design of axial loaded rectangular column sloped footing

load on column = 500 Kn


size of column = B(mm)= 230 D(mm)= 300 mm
cover(mm) = 50 0.23 m 0.3 m
SBC = 200 Kn/m2
Fck = 20 N/mm2
Fy = 415 N/mm2
bar dia = 12 mm a,st 113.097336
load on footing = 550 Kn
factored load on footing= 750 Kn
area = 2.75 m2
size of footing = B= 1.5472951 D= 1.9 m
taken B= 1.6 m
area provided = 3.04 m2
upward pressure = 246.71052632 Kn/m2
critical length 0.8 m
B.M
along shorter span 150 Knm
along longer span 126.31578947 Knm
eff. depth(d)
along longer span = 347.04235442 mm
along shorter span = 347.52402343 mm
try overall depth(D=d+150)= 400 mm (put manually)
taken depth along longer span= 344 mm
taken depth along shorter span= 332 mm
taken avg depth(d) = 338 mm

Reinforcement
along longer span pt%= 1.0800797797 %
Ast= 1613.6391909
no of bar 15
Ast prov = 1696.4600329
pt% prov = 1.135515417 %
along shorter span pt%= 0.976112322 %
Ast= 1275.9740273
no of bar = 12
Ast prov = 1357.1680264
pt% prov = 1.0382252344 %
spacing
along longer dir
c/c = 127.71428571 mm
clear spacing = 115.71428571 mm OK if spacing is>180 ,change bar dia)
along shorter dir
c/c = 135.27272727
clear spacing = 123.27272727 Ok

check for oneway shear(at a dist d from face of support)


along longer span
l of critical sec = 456 mm
depth at critical sec 96.9 mm l
d' = 270.9 mm. = 0.2709 m 800
b' = 918 mm
Vu 180 kn
Tau v = 0.5943526781 N/mm2 mu= 41.04
Tau c (from table usingpt% along longer dir)pt%prov 1.135515417 %
Tau c = 0.65 N/mm2 OK (put manually)

check for twoway shear

length of critical sec = 631 mm


depth @ critical sec = 134.0875
d' = 296.0875 mm
b' = 2412 mm
Vu = 660.59605263 Kn
Tau v 0.9249933228 N/mm2
Tau c = 1.1180339887
ks = 1.2666666667
Tau c' = 1.4161763857
check(Tau v<Tau c')
Tau v < Tau c' OK

summary dia(mm) no.s spacing(in mm)


along longer span 12 15 115.7142857
along shorter span 12 12 123.2727273
180 ,change bar dia)
D
170 tanB= 0.2125

knm
design of Ecentric footing

load on column(Pu) = 513.33333333 Kn Pu= 770 kn


Mx = 110 kn-m Mux= 165 kn-m
My = 50 knm Muy= 75 kn-m
size of column = B= 0.3 D= 0.6 m
cover(mm) = 50 300 mm 600 mm
SBC = 200 Kn/m2
Fck = 25 N/mm2
Fy = 415 N/mm2
bar dia = 12 mm ast= 113.0973355 B L
load on footing = Kn 2.1 2.4
factored load on footing= Kn
area taken B= 2.1 D= 2.4 m
B.M @ face of column
for Mx =
length = 0.9 m
Pmax 156.41534392 kn/m2
Pmin 47.288359788 kn/m2
p 115.49272487 kn/m2
Mx 121.4296875 knm
Mux 182.14453125 knm
for My
Pmax 130.19652305 kn/m2
Pmin 73.50718065 kn/m2
P 105.90109059 kn/m2
My 118.67930029 knm
Muy 178.01895044 knm
depth of footing
dx 158.55826074 mm
dy 146.62835074 mm
D=(2-2.5)*d 500 mm
taken dx 444 mm
taken dy 432 mm
Avg d 438 mm
Reinforcement
along long dir
pt% req 0.124494408 %
Ast 1160.7858606 mm2
min Ast 1260 mm2
take Ast 1260
no of bar 12
Ast prov 1357.1680264 mm2
pt prov 0.1455564164 %
along short dir
pt req 0.1122288366 %
Ast req 1163.5885782
min Ast 1440
taken Ast 1440
no of bar 13
Ast prov 1470.2653619
pt prov 0.1418080017 %

spacing
along long span
c/c 180.72727273 mm
clear spacing 168.72727273 mm OK
along long span
c/c 190.66666667 mm
clear spacing 178.66666667 mm OK

oneway shear check


along longer span
length 0.456 m
P @ critical sec 135.68121693 kn/m2
Vu 209.78375 kn
Tau v 0.2249932969 N/mm2
Tau c 0.29 N/mm2 OK (put manually)
along shorter span
length 0.468 m
P @ critical sec 119.14210128 kn/m2
Vu 210.04285714 kn
Tau v 0.2025876323 N/mm2
Tau c 0.29 N/mm2 OK (put manually)

Two way shear check(at d/2 dist from face of column)


length 0.681 m
p @ this length 125.45056217 kn/m2
Vu 204.28351336
Tau v 0.6234390286 N/mm2
Tau c 1.25
ks 1
Tau c' 1.25
check(Tau v<Tau c')
Tau v < Tau c' OK
A Zx Zy P/A Mx/Zx My/Zy Pmax Pmin
5.04 2.016 1.764 101.851851852 54.56349206 28.344671202 184.76 18.94369
check
OK