11-4 Troubleshooting
Alarm Status when error
Error conditions Cause Measures
display occurs
· The disconnection detection
function was activated · Wire correctly.
because communications · Fix the locations that
between the external scale are disconnected.
External scale and driver were interrupted.
50 Occurs during operation.
communications error
· There was a · Provide the required external
communications error scale power supply voltage.
in data from external · Wire correctly.
scale. · Connect the shield to FG.
· Check the external
scale specifications.
External scale status · An external scale error · From the front panel, clear
51 Occurs during operation.
error code was detected. the external scale error,
then turn the power supply
OFF, then ON again.
· A disconnection or
other error was
Phases-A, B and Z
55 Occurs during operation. detected in external · Check the connection.
connection error
scale phase A, phase B,
or phase Z connection.
· The forced alarm input · Turn OFF the EMG-
87 Forced alarm input error Occurs during operation.
signal was input. STOP signal.
· The motor and driver · Use a correct
combination is incorrect. combination.
Occurs when the power
95 Motor non-conformity · Wire the encoder wiring.
supply is turned ON. · The encoder wiring is
· Fix the locations that
disconnected.
are disconnected.