TwinPlus Module
Perc/370-385W TO
PP
2018
E R F OR M
ER
PV MODULE
RELIABILITY SCORECARD
PID PID Resistant
Better shading tolerance
More Reliable
Lower hot spot temperature
More Power
Low power loss in cell connection
Low temperature coefficient (Pmax): -0.38% / °C
Low NOCT: 43±2°C
100%
12 12-year product warranty
25 25-year linear performance warranty
Guaranteed Power
97%
90%
72
70%
0 5 10 15 20 25
Industry standard Phono Solar Year 2x
Cells
EN EN-20190514
ELECTRICAL TYPICAL VALUES
PS370M-24/TH PS375M-24/TH PS380M-24/TH PS385M-24/TH
Model
PS370MH-24/TH PS375MH-24/TH PS380MH-24/TH PS385MH-24/TH
Type Monocrystalline 6 inch x 3 inch square
Rated Power (Pmpp) 370W 375W 380W 385W
Tolerance 0~+5w
Rated Current (Impp) 9.29 9.35 9.42 9.48
Rated Voltage (Vmpp) 39.83 40.11 40.35 40.62
Short Circuit Current (Isc) 9.71 9.79 9.87 9.95
Open Circuit Voltage (Voc) 47.44 47.69 47.94 48.19
Module Efficency (%) 18.65 18.90 19.15 19.41
NOCT (Nominal Operation Cell Temperature) 43±2℃
Voltage Temperature Coefficient -0.30%/℃
Current Temperature Coefficient +0.05%/℃
Power Temperature Coefficient -0.38%/℃
MECHANICAL CHARACTERISTICS ELECTRICAL CHARACTERISTICS
Length: 2000mm (78.75 inch)
Dimension (L× W × H) Width: 992mm (39.06 inch) 400
Cell temp.=25℃
350
Height: 40mm (1.57 inch) Incident Irrad.=1000W/m2
Incident Irrad.=800W/m2
300
Incident Irrad.=600W/m2
Weight 22.6kg (49.8 lbs) 250
Incident Irrad.=400W/m2
Incident Irrad.=200W/m2
Front Glass 3.2mm toughened glass 200
Power [W]
Frame Anodized aluminium alloy 150
100
4mm² (IEC) ,Length:350mm(vertical)
Cable 50
1250mm(horizontal)or Customized length
0
0 10 20 30 40 50
Junction Box IP 68 rated Voltage [V]
12
Cell temp.=25℃
10
ABSOLUTE MAXIMUM RATING Incident Irrad.=1000W/m2
8 Incident Irrad.=800W/m2
Current [A]
Parameter Values Incident Irrad.=600W/m2
6
Operating Temperature From -40 to +85°C 4 Incident Irrad.=400W/m2
Incident Irrad.=200W/m2
Hail Diameter @ 80km/h Up to 25mm 2
0
Surface Maximum Load Capacity Up to 5400Pa 0 10 20 30 40 50
Voltage [V]
Maximum Series Fuse Rating 20A
Application Class and Safety Class Ⅱ
Fire Rating (IEC61730) C
Module Fire Performance (UL 1703) Type1
Maximum System Voltage DC 1000V/1500V (IEC/ETL)
PACKING CONFIGURATION
Container 20' GP 40' HQ
Pieces/Container 230 616
1. In compliance with our warranty terms and conditions.
2. Measurement conditions under irradiance level of Standard Test
Conditions(STC): 1000W/m
Air mass 1.5 Spectrum, cell temperature of 25°C.
Note: This datasheet is not legally binding. Phono Solar Technology Co., Ltd.
reserves the right to adjust specifications without notice. Further information please
refer to our Website:www.phonosolar.com, E-mail:info@phonosolar.com