Abbreviations Symbols Demolition Notes: 1 09/07/2018 Issue For Bid 2 09/13/2018 Addendum 1

The document provides symbols, abbreviations, and demolition notes for a construction project. It lists common symbols that will be used on drawings like cold water, hot water, and pipe guides. It also lists common abbreviations. There are 5 demolition notes that specify what work must be done as part of demolition including determining the full scope, identifying salvageable items, proper disposal of removed materials, and fully removing fixtures and associated piping.

Uploaded by

Md. Farid Uddin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
210 views9 pages

Abbreviations Symbols Demolition Notes: 1 09/07/2018 Issue For Bid 2 09/13/2018 Addendum 1

The document provides symbols, abbreviations, and demolition notes for a construction project. It lists common symbols that will be used on drawings like cold water, hot water, and pipe guides. It also lists common abbreviations. There are 5 demolition notes that specify what work must be done as part of demolition including determining the full scope, identifying salvageable items, proper disposal of removed materials, and fully removing fixtures and associated piping.

Uploaded by

Md. Farid Uddin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

SYMBOLS ABBREVIATIONS DEMOLITION NOTES

COLD WATER (CW) PIPE GUIDE ABV ABOVE M METER 1. DEMOLITION INFORMATION SHOWN ON THE DRAWINGS IS BASED
AC AIR COMPRESSOR MA MEDICAL AIR ON SHOP DRAWINGS AND A REVIEW OF THE EXIST CONDITIONS.
COLD WATER (CW) EXISTING DIRECTION OF FLOW AP ACCESS PANEL MAM MEDICAL AIR MANIFOLD
AD AREA DRAIN MAC MEDICAL AIR COMPRESSOR 2. PERFORM ALL WORK OF A DEMOLITION NATURE THAT MAY BE
COLD WATER (CW) DEMO PIPE ANCHOR AE ANAEROBIC PIPING OR ANESTHESIA EVACUATION MAU MAKEUP AIR UNIT REQUIRED OR NECESSARY FOR A FULL AND COMPLETE
AFF ABOVE FINISHED FLOOR MAX MAXIMUM EXECUTION OF THE WORK, WHETHER OR NOT SHOWN OR
UNION AFG ABOVE FINISHED GRADE MBTU 1,000 BRITISH THERMAL UNITS SPECIFIED. THE EXACT EXTENT OF DEMOLITION MAY NOT BE
AHJ AUTHORITY HAVING JURISDICTION MD MAIN DRAIN FULLY INDICATED BY THE DRAWINGS. DETERMINE THE NATURE
HOT WATER (HW) VALVE AHU AIR HANDLING UNIT MECH MECHANICAL AND EXTENT OF DEMOLITION THAT WILL BE NECESSARY BY
ANB ACID NEUTRALIZING BASIN MER MECHANICAL EQUIPMENT ROOM COMPARING THE CONTRACT DOCUMENTS WITH THE FIELD
HOT WATER (HW) EXISTING BALL VALVE ARCH ARCHITECTURE MEZZ MEZZANINE CONDITIONS PRIOR TO BIDS.
ASSY ASSEMBLY MFR MANUFACTURER
HOT WATER (HW) DEMO ANGLE VALVE ATM ATMOSPHERE MGA MASTER GAS ALARM 3. MATERIALS AND EQUIPMENT TO BE SALVAGED OR REUSED SHALL Department of Capital Planning & Policy
AUTO AUTOMATIC MH MANHOLE BE IDENTIFIED BY THE OWNER. THESE ITEMS ARE THE
OS&Y VALVE AUX AUXILIARY MIN MINIMUM OR MINUTES PROPERTY OF THE OWNER AND SHALL BE RETURNED TO THE Bureau of Asset Management
AV ACID VENT mm MILLIMETER OWNERS DESIGNATED STORAGE AREA. WHERE REMOVAL IS
AVTR ACID VENT THRU ROOF MS MOP SINK REQUIRED THE CONTRACTOR SHALL BE RESPONSIBLE FOR CARE Notice: This drawing has not been published and is the
HOT WATER RETURN (HWR) CHECK VALVE (SHOWN W/FLOW)
AW ACID WASTE MTD MOUNTED TAKEN DURING THE HANDLING OF THESE ITEMS. sole property of Cook County. It is loaned to the borrower
MV MEDICAL VACUUM for their confidential use only. In consideration of the loan
HOT WATER RETURN (HWR) EXISTING BALANCING VALVE
B/S BELOW SLAB MVP MEDICAL VACUUM PUMP 4. DEMOLISHED MATERIALS AND EQUIPMENT NOT BEING
BFP BACKFLOW PREVENTER SALVAGED OR REUSED, SHALL BECOME THE PROPERTY OF THE of this drawing, the borrower promises and agrees to
HOT WATER RETURN (HWR) DEMO CAPPED PIPING
BFV BUTTERFLY VALVE NA NOT APPLICABLE CONTRACTOR AND REMOVED FROM THE SITE AND LEGALLY return it upon request and agrees that it shall not be
BHP BRAKE HORSEPOWER N&C NIPPLE AND CAP DISPOSED OF. reproduced, copied, loaned, or otherwise disposed of
PLUG END OF PIPE BLDG BUILDING N.C. NORMALLY CLOSED
BOB BOTTOM OF BEAM N2 NITROGEN 5. WHERE EXISTING FIXTURES ARE INDICATED TO BE DEMOLISHED: directly or indirectly, nor used for any purpose other than
NON POTABLE COLD WATER (NPCW) GAS COCK BOP BOTTOM OF PIPE N2CP NITROGEN CONTROL PANEL THIS SHALL INCLUDE ALL ASSOCIATED PIPING, CARRIERS, for which it is furnished, in whole or part.
BPW BED PAN WASHER N2M NITROGEN MANIFOLD SUPPORTS, SLEEVES, HANGERS, FITTINGS, AND OTHER
NON POTABLE COLD WATER (NPCW) EXISTING CONTROL VALVE BSMT BASEMENT N2O NITROUS OXIDE ACCESSORIES. PIPING SHALL BE REMOVED TO A LOCATION
BT BATH TUB NIC NOT IN CONTRACT ABOVE THE CEILING OR BEHIND WALLS AND CAPPED. HOWEVER,
NON POTABLE COLD WATER (NPCW) DEMO SOLENOID VALVE BTU BRITISH THERMAL UNIT NO. NUMBER NO INACTIVE BRANCH OF MORE THAN 2 FEET IN LENGTH CAN
BTUH BRITISH THERMAL UNIT PER HOUR N.O. NORMALLY OPEN REMAIN ON ANY PIPE. CONTRACTOR SHALL REMOVE AS
GAS PRESSURE REGULATOR (GPR) BV BALL VALVE N2OM NITROUS OXIDE MANIFOLD REQUIRED.
BWV BACKWATER VALVE NPCW NON POTABLE COLD WATER
NON POTABLE HOT WATER (NPHW) PRESSURE REDUCING VALVE (PRV) NPHW NON POTABLE HOT WATER 6. WHERE DEMOLITION OF FIXTURE AND REMOVAL OF PIPING OR
CA COMPRESSED AIR NPHWR NON POTABLE HOT WATER RETURN OTHER ACCESSORY LEAVES AN OPENING IN THE FLOOR, WALL,
NON POTABLE HOT WATER (NPHW) EXISTING SAFETY/RELIEF VALVE CALC CALCULATE NPW NON POTABLE WATER OR CEILING, SAME SHALL BE PATCHED TO MATCH EXISTING
CAP CAPACITY NTS NOT TO SCALE ADJACENT FINISH.
NON POTABLE HOT WATER (NPHW) DEMO PRESSURE-TEMPERATURE RELIEF VALVE (PRV) CCD CHICAGO CITY DATUM
CFH CUBIC FEET PER HOUR OBY OIL BASIN VENT
SLEEVE CFM CUBIC FEET PER MINUTE OD OUTSIDE DIAMETER
HB CFS CUBIC FEET PER SECOND OFCI OWNER FURNISHED CONTRACTOR INSTALLED
NON POTABLE HOT WATER RETURN (NPHWR) HOSE BIB (HB) CG COMPOUND GAUGE OFOI OWNER FURNISHED OWNER INSTALLED
WH CI CAST IRON OFD OVERFLOW DRAIN
NON POTABLE HOT WATER RETURN (NPHWR) EXISTING NON-FREEZE WALL HYDRANT (WH) CLG CEILING OHD OPEN HUB DRAIN
CLK CLINICAL SINK OM OXYGEN MANIFOLD
NON POTABLE HOT WATER RETURN (NPHWR) DEMO ROOF DRAIN (RD) cm CENTIMETER OS&Y OUTSIDE SCREW AND YOKE
CO CLEANOUT OSW OPEN SITE WASTE
FLOOR DRAIN (FD) CO2 CARBON DIOXIDE O2 OXYGEN
COL COLUMN
V VENT (V) COMPR COMPRESSOR PBV PRESSURE BALANCING VALVE
FLOOR DRAIN (FD)
CONC CONCRETE PC PLUMBING CONTRACTOR
EX. V VENT (V) EXISTING CONN. CONNECTION PCU PATIENT CARE UNIT
TRENCH DRAIN (TD)
CONT. CONTINUED PD PUMP DISCHARGE OR PLANTER DRAIN
VENT (V) DEMO CO CLEANOUT (CO) CONTR
CV
CONTRACTOR
CHECK VALVE
PG
PH
PRESSURE GAUGE
PENTHOUSE OR PHASE GENERAL NOTES
FCO FLOOR CLEANOUT (FCO) CW COLD WATER PITCH PITCHES UP OR DOWN
CWV CLEAR WATER VENT PIV POST INDICATOR VALVE
W WASTE (W) GCO GROUND CLEANOUT (GCO) CWW CLEAR WATER WASTE PKG PACKAGE
PLBG PLUMBING
EX. W WASTE (W) EXISTING P-TRAP DCV DOUBLE CHECK VALVE POC POINT OF CONNECTION
DCW DOMESTIC COLD WATER PP PLUMBING PUMP
WASTE (W) DEMO WALL CLEANOUT (CO) DDCV DOUBLE DETECTOR CHECK VALVE PPM PARTS PER MILLION 1. ALL VALVES SHALL BE READILY ACCESSIBLE FROM A SAFE HEIGHT
DF DRINKING FOUNTAIN PRESS PRESSURE ON A SIX FOOT LADDER AND TO BE CLEAR OF ALL OBSTRUCTIONS.
DH DECK HYDRANT PRV PRESSURE REDUCING VALVE OPERATION SHALL NOT BE ENCUMBERED BY ANY DEVICE OR
STRAINER
DHW DOMESTIC HOT WATER PSI POUNDS PER SQUARE INCH EQUIPMENT.
ST STORM (ST) DI DEIONIZED WATER PSIG POUNDS PER SQUARE INCH GAUGE
THERMOMETER (SPECIFY TYPE) (TH)
DIA DIAMETER 2. ALL WATER PIPING SUPPLYING FIXTURES FROM WALLS OR CHASES
DIM DIMENSION QTY QUANTITY SHALL BE PIPED FROM A FULL SIZED HORIZONTAL MANIFOLD,
EX. ST STORM (ST) EXISTING PRESSURE GAUGE WITH GAUGE COCK (PG) DN DOWN VERTICAL BRANCHES FROM THE MANIFOLD, INCLUDING AIR
A DR DRAIN RD ROOF DRAIN CHAMBERS, SHALL BE ONE PIPE SIZE LARGER THAN THE SIZE
STORM (ST) DEMO AQUASTAT DS DOWNSPOUT OR RAIN LEADER DESIGNATION RN RISER NIPPLE INDICATED UNDER "CONNECTIONS" OF THE FIXTURE SPECIFICATIONS.
"A"
DSDB DIALYSIS SUPPLY AND DRAIN BOX RO REVERSE OSMOSIS SEE LANS FOR SUPPLY PIPE SIZING TO WALLS OR CHASES.
WATER HAMMER ARRESTER (LETTER DT DRAIN TILE ROR REVERSE OSMOSIS RETURN
DESIGNATES SIZE) DV DRAIN VALVE ROS REVERSE OSMOSIS SUPPLY 3. DO NOT SUPPORT PLUMBING PIPING FROM METAL DECK.
AV ACID VENT (AV) DW DISHWASHER ROB ROD OUT BASIN
BACKFLOW PREVENTER (BFP) DWG DRAWING RP RECIRCULATING PUMP 4. COORDINATE SCHEDULE FOR HOOK-UPS TO EXISTING SYSTEMS AND
EX. AV ACID VENT (AV) EXISTING RPM REVOLUTIONS PER MINUTE EQUIPMENT REMOVAL OR RELOCATIONS WITH THE OWNER AND
BOTTOM DROP
EA EACH RPZ REDUCED PRESSURE ZONE PERFORM THIS WORK AT SUCH TIMES TO ENSURE THAT PERIODS
ACID VENT (AV) DEMO EC ELECTRICAL CONTRACTOR RTU ROOF TOP UNIT OF SHUTDOWN WILL BE ACCEPTABLE TO THE OWNER.
ELBOW DOWN
EEW EMERGENCY EYE WASH RW RECLAIMED WATER
EF EXISTING FIXTURE TO REMAIN 5. VERIFY EXACT LOCATION OF CONNECTION POINTS (NEW TO
ELBOW UP
EFF EFFICIENCY S SANITARY (RISER) EXISTING) IN FIELD PRIOR TO CONSTRUCTION.
AW ACID WASTE (AW) EJ EXPANSION JOINT SAN SANITARY SEWER (EXTERIOR)
RISE OR DROP ELEC ELECTRICAL SB SETTLING BASIN 6. COORDINATE INSTALLATION OF NEW PIPING WITH EXISTING BUILDING
ACID WASTE (AW) EXISTING ELEV. ELEVATION SCV SECTIONAL CONTROL VALVE W/ TAMPER SWITCH STRUCTURE, DUCTWORK, PIPING, ELECTRICAL CONDUIT, LIGHTING,
EX. AW POINT OF DISCONNECTION ES EMERGENCY SHOWER SE SEWAGE EJECTOR ETC.
ACID WASTE (AW) DEMO EEW/ES COMBINATION EMERGENCY SHOWER/EYEWASH STATION S.F. SQUARE FOOT
POINT OF CONNECTION (NEW TO EXISTING) EQUIP EQUIPMENT SH SHOWER 7. RELOCATE EXISTING PIPING IN EXISTING CEILING SPACES TO Holabird & Root, LLC expressly disclaims any
ET EXPANSION TANK SK SINK ACCOMMODATE ALL RENOVATIONS AND ADDITIONS. responsibility arising from any unauthorized use of these
OXYGEN OUTLET EVAC EVACUATION PIPING SL SLOPE plans, drawings and notes. Any authorization must be in
EWC ELECTRIC WATER COOLER SMP SUMP PUMP 8. REFER TO ARCHITECTURAL ELEVATION DRAWINGS FOR LOCATION OF
UNDERGROUND VENT MEDICAL VACUUM OUTLET EWH ELECTRIC WATER HEATER SP STANDPIPE WALL MOUNTED MECHANICAL ITEMS. writing.
EX EXISTING SQ SQUARE
UNDERGROUND VENT EXISTING ANESTHESIA EVACUATION OR WAGD OUTLET EXIST EXISTING SS SERVICE SINK 9. THIS PLAN IS APPROVED FOR WORK INDICATED PER THE APPLICABLE This drawing copy may have been reproduced at a size
EXP EXPANSION SSD SUB SOIL DRAINAGE DRAWINGS AND SPECIFICATIONS ONLY. ALL OTHER AREAS SHOWN
UNDERGROUND VENT DEMO MEDICAL AIR OUTLET SSS SURGEONS SCRUB SINK ARE FOR REFERENCE ONLY AND SHALL NOT BE CONSIDERED OR different than originally drawn. The Owner and Architect
F FAHRENHEIT ST STORM SEWER (OR STORM RISER) APPROVED TO BE IN ACCORDANCE WITH APPLICABLE CODES OR assume no responsibility for use of incorrect scale.
COMPRESSED AIR OUTLET FA FIRE ALARM STK STACK AUTHORITY HAVING JURISDICTION. Drawings are not to be scaled.
FACP FIRE ALARM CONTROL PANEL STR STACK THRU ROOF
UNDERGROUND SANITARY OR STORM NITROUS OXIDE OUTLET FBO FURNISHED BY OTHERS STW STORM WATER (FROM DETENTION TANK) 10. NOT ALL PIPING AND SIZES ARE SHOWN ON THE DRAWINGS FOR
FCO FLOOR CLEANOUT SUB-CONTR. SUB CONTRACTOR CLARITY. REFER TO STACK DIAGRAMS, AND WATER RISERS FOR Not published - All rights reserved.
UNDERGROUND SANITARY OR STORM EXISTING CARBON DIOXIDE OUTLET FD1,2,3... FLOOR DRAIN SWR SOLAR WATER RETURN ADDITIONAL PIPING AND SIZES.
FIN FINISH SWS SOLAR WATER SUPPLY
UNDERGROUND SANITARY OR STORM DEMO NITROGEN OUTLET FF FINISHED FLOOR SYS SYSTEM 11. CUT, PATCH AND MATCH EXISTING CEILINGS, WALLS AND FLOORS AS
FIXT FIXTURE REQUIRED PER INSTALLATION OF PLUMBING PIPING.
LABORATORY OUTLET FH FUME HOOD T&P TEMPERATURE AND PRESSURE
FLR FLOOR TB THRUST BLOCK 12. CAREFULLY REMOVE AND INSTALL EXISTING CEILING TILES AS
DI DEIONIZED WATER (DI) FPM FEET PER MINUTE TD TRENCH DRAIN REQUIRED PER INSTALLATION OF PLUMBING PIPING. DAMAGED
WR RISER INDICATOR / DETAIL INDICATOR
TOP INDICATES TYPE OF RISER / DETAIL NO. FPS FEET PER SECOND TEMP TEMPERATURE CEILING TILES TO BE REPLACED BY PLUMBING CONTRACTOR.
EX. DI DEIONIZED WATER (DI) EXISTING 1 FS FLOW SWITCH OR FLOOR SINK TH THERMOMETER
BOTTOM INDICATES RISER NUMBER / DWG NO.
FT FOOT/FEET TMV THERMOSTATIC MIXING VALVE 13. ALL EXISTING BUILDING UTILITIES HAVE BEEN DOCUMENTED FROM
DEIONIZED WATER (DI) DEMO FV FLUSH VALVE TOB TRIPLE OIL BASIN AVAILABLE DRAWINGS, RECORDS AND FIELD SURVEY AND
RISER INDICATOR -
WR TW TEMPERED WATER THEREFORE, THEIR LOCATIONS MUST BE CONSIDERED APPROXIMATE
TOP INDICATES TYPE OF RISER,
1 G NATURAL GAS TYP TYPICAL ONLY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
BOTTOM INDICATES RISER NUMBER
(ARROW INDICATES DIRECTIONAL VIEW OF GAL GALLON DETERMINE THE LOCATION AND SIZE OF ALL EXISTING UTILITIES
RO REVERSE OSMOSIS (RO) GALV GALVANIZED UG UNDERGROUND BEFORE BEGINNING WORK.
ISOMETRIC RISERS)
GC GENERAL CONTRACTOR UNO UNLESS NOTED OTHERWISE
EX. RO REVERSE OSMOSIS (RO) EXISTING GCO GRADE OR GROUND CLEANOUT UR URINAL 14. THIS IS A GENERAL LIST OF ABBREVIATIONS AND SYMBOLS ON THIS
1 SECTION INDICATOR GD GARAGE DRAIN SHEET. SOME ABBREVIATIONS AND SYMBOLS MAY NOT BE
REVERSE OSMOSIS (RO) DEMO TOP INDICATES SECTION NUMBER GI GREASE INTERCEPTOR V VENT APPLICABLE TO THIS PROJECT.
P101 BOTTOM INDICATES DRAWING NUMBER GPH GALLONS PER HOUR VB VACUUM BREAKER
GPM GALLONS PER MINUTE VEL VELOCITY 15. THE SPACE ABOVE THE CEILING IS LIMITED AND THE INSTALLATION OF 2 09/13/2018 ADDENDUM 1
GTV GATE VALVE VERT VERTICAL WORK WILL BE TIGHT. DUE TO THIS, IT IS IMPORTANT THAT THE
TW TEMPERED WATER (TW) GW GARAGE WASTE VIF VERIFY IN FIELD TRADE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF 1 09/07/2018 ISSUE FOR BID
VTR VENT THRU ROOF THEIR WORK WITH THE CEILING SYSTEM HEIGHT AND No. Date Issue
BASIN
EX. TW TEMPERED WATER (TW) EXISTING H HYDROGEN PIPING CONSTRUCTION, THE STRUCTURAL SYSTEM, THE LIGHTING FIXTURES,
HB HOSE BIBB W WASTE (INTERIOR) THE SPRINKLER HEADS / MAINS AND THE PLUMBING PIPES. ROUTE
TEMPERED WATER (TW) DEMO HD HEAD OR HUB DRAIN W/ WITH PIPING AS HIGH AS POSSIBLE. MAINTAIN PROPER SERVICE ACCESS
HE HELIUM PIPING WAGD WASTE ANESTHESIA GAS DISPOSAL CLEARANCE. ACCURATE SHOP DRAWINGS SHALL BE SUBMITTED FOR
EXPANSION JOINT HP HORSEPOWER OR HIGH POINT WC WATER CLOSET APPROVAL, PRIOR TO FIELD INSTALLATION. Project Number 15849
HR HOUR WCO WALL CLEANOUT
GW GARAGE WASTE (GW) FLEXIBLE CONNECTION HS HOSE STATION WF WASH FOUNTAIN OR WATER FILTER 16. DO NOT INSTALL ANY NEW WORK DIRECTLY ABOVE ANY ELECTRICAL Drawn FA
HVAC HEATING-VENTILATION-AIR CONDITIONING WH WALL HYDRANT PANELS AND TRANSFORMERS.
EX. GW GARAGE WASTE (GW) EXISTING PUMP HW HOT WATER WHA WATER HAMMER ARRESTOR
HWR HOT WATER RETURN WM WATER METER 17. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND MAY NOT Checked FA
M WATER METER HYD HYDRAULIC WMSD WASHING MACHINE SUPPLY AND DRAIN BOX SHOW EXACT ROUTING OR ALL REQUIRED OFFSETS, ACCESSORIES
GARAGE WASTE (GW) DEMO Proj. Arch./Eng. FA
Hz HERTZ W/O WITHOUT OR APPURTENANCES. CONTRACTOR SHALL PROVIDE AS REQUIRED
EXPANSION LOOP WR WATER RISER TO INSTALL A COMPLETE AND COORDINATED JOB, INCLUDING ANY
IC INSULATING COUPLING ADDITIONAL ITEMS REQUIRED TO MEET ACTUAL FIELD CONDITIONS
VENT THRU ROOF OR ACID VENT THRU ROOF ID INDIRECT DRAIN YH YARD HYDRANT AND ACTUAL EQUIPMENT SELECTED.
IW INDIRECT WASTE (IW) YCO YARD CLEANOUT
IM ICE MACHINE
ZONE VALVE BOX INSUL INSULATION 18. FOR EXACT LOCATION OF EQUIPMENT AND FIXTURES, SEE
EX. IW INDIRECT WASTE (IW) EXISTING IN INCHES ZVB ZONE VALVE BOX ARCHITECTURAL DRAWINGS.
INV. ELEV. INVERT ELEVATION
INDIRECT WASTE (IW) DEMO PRESSURE SWITCH
IW INDIRECT WASTE 19. NO EQUIPMENT OR DEVICE REQUIRING REGULAR ACCESS OR Provident Hospital - Renal
IWH INTERIOR WALL HYDRANT MAINTENANCE SHALL BE INSTALLED IN AN INACCESSIBLE CEILING
MASTER OR AREA ALARM PANEL
CAVITY. LOCATE SUCH ITEMS ABOVE ACOUSTIC TILE CEILINGS Dialysis Center
KEC KITCHEN EQUIPMENT CONTRACTOR WHEREVER POSSIBLE. IF ANY SUCH ITEMS ARE REQUIRED TO BE
KW KITCHEN WASTE (KW) NITROGEN CONTROL PANEL
KW KITCHEN WASTE INSTALLED ABOVE DRYWALL CEILINGS, PROVIDE AN ACCESS PANEL
OR PANELS SIZED AND LOCATED TO PROVIDE SUFFICIENT ACCESS
EX. KW KITCHEN WASTE (KW) EXISTING MEDICAL CEILING COLUMN L LAVATORY FOR EQUIPMENT SERVICE. SUBMIT LAYOUT OF ALL REQUIRED
LA LABORATORY AIR ACCESS PANELS FOR ARCHITECTS REVIEW AND APPROVAL PRIOR
KITCHEN WASTE (KW) DEMO WASHING MACHINE SUPPLY AND DRAIN BOX LBS POUNDS TO THE ONSET OF INSTALLATION.
LPA LINE PRESSURE ALARM
KEYED NOTE TAG LPG LIQUID PROPANE GAS
LPM LITERS PER MINUTE
LW LAUNDRY WASTE (LW) XX NEW EQUIPMENT TAG LPT LOW POINT
LP LIQUID PROPANE
EX. LW LAUNDRY WASTE (LW) EXISTING LSK LAB SINK
(E)XXX
LT LAUNDRY TUB
LAUNDRY WASTE (LW) DEMO EXISTING EQUIPMENT TAG LV LABORATORY VACUUM
EXISTING LW LAUNDRY WASTE OR LAB WASTE 430 East 51st Place
LWH LAB WATER HEATER
Chicago, Illinois 60615
AREA MATCHLINE
G NATURAL GAS (G)

EX. G NATURAL GAS (G) EXISTING Project Name


NATURAL GAS (G) DEMO

SYMBOLS, ABBREVIATIONS &


GENERAL NOTES
Sheet Name

Drawing No. P0001


PLUMBING GENERAL NOTES: PLUMBING KEYNOTES
1. SHUT-DOWN NOTICE IS REQUIRED FOR ANY SYSTEM SHUT-DOWNS. 1 PLUMBING CONTRACTOR SHALL DISCONNECT AND REMOVE EXISTING
PROVIDE A MINIMUM OF 72 HOURS NOTICE. PLANTER/FLOOR DRAIN. CUT AND CAP SANITARY PIPE IN FLOOR. PATCH FLOOR TO
2. EXISTING SYSTEMS MUST BE PUT BACK INTO SERVICE AT THE END OF MATCH EXISTING.
EACH WORK DAY, INCLUDING COMPLETE VISUAL INSPECTION PRIOR TO 2 EXISTING WATER CLOSET TO REMAIN.
THE CREW LEAVING FOR THE DAY.
3. PLUMBING CONTRACTOR TO COORDINATE WITH THE MECHANICAL 3 EXISTING LAVATORY TO REMAIN.
CONTRACTOR REGARDING THE REROUTE/RAISING OF EXISTING PLUMBING 4 EXISTING URINAL TO REMAIN.
PIPING IN ORDER TO ACCOMMODATE NEW DUCTWORK, MECHANICAL, 5 EXISTING ELECTRIC WATER COOLER TO REMAIN.
ELECTRICAL AND FIRE PROTECTION SYSTEMS. THE EXTENT OF REROUTES 6 EXISTING FLOOR DRAIN TO REMAIN.
REQUIRED TO BE FIELD DETERMINED. REFER TO ARCHITECTURAL CEILING 7 EXISTING 4" STORM UP TO EXISTING ROOF DRAIN TO REMAIN.
PLAN.
8 EXISTING STORM DOWN THRU FLOOR TO REMAIN. COORDINATE BOX OUT WITH
4. PLUMBING CONTRACTOR SHALL EMPLOY THE USE OF UNDERGROUND
ARCHITECT. EXISTING WALL CLEANOUT AT BASE OF RISER TO REMAIN.
PIPING LOCATING EQUIPMENT IN ORDER TO PROPERLY LOCATE AND
TRACE PIPING SYSTEMS. 9 1-1/2" SANITARY TO DIALYSIS BOX (TYPICAL).
5. PLUMBING CONTRACTOR SHALL SAWCUT SLAB AS REQUIRED TO 10 PIPES UNDER COUNTER. 2" VENT ABOVE, 2" SANITARY BELOW (TYPICAL).
COMPLETE WORK. PLUMBING CONTRACTOR SHALL PATCH SLAB TO
MATCH EXISTING.
11
12
3" VENT UP TO 3"X6" VENT THRU ROOF.
2" VENT DROP, 2" SANITARY DOWN THRU FLOOR, 2" VENT DOWN THRU FLOOR
Department of Capital Planning & Policy
6. ALL EQUIPMENT SHOWN ON PLAN IS NEW AND HAS BEEN OBTAINED FROM
THE OWNER\S EXISTING CONSTRUCTION DOCUMENTS. PLUMBING
13
SERVING SINK. REFER TO ISLAND PIPING DETAIL ON SHEET P0600.
2" VENT DOWN THRU FLOOR, 2" VENT DROP, 2" SANITARY DOWN THRU FLOOR.
Bureau of Asset Management
CONTRACTOR SHALL FIELD VERIFY THE SIZE AND LOCATION OF ALL
EXISTING EQUIPMENT. 14 (2) 2" VENT DOWN THRU FLOOR. Notice: This drawing has not been published and is the
15 2" VENT DOWN THRU FLOOR, 2" VENT DROP. sole property of Cook County. It is loaned to the borrower
16 2" VENT UP TO 2"X4" VENT THRU ROOF. for their confidential use only. In consideration of the loan
17 2" VENT DOWN THRU FLOOR.
of this drawing, the borrower promises and agrees to
18 2" VENT DROP, 2" SANITARY OFFSET IN WALL. 2" SANITARY DOWN THRU FLOOR AS
INDICATED. return it upon request and agrees that it shall not be
19 EXTEND AND CONNECT NEW WATER CLOSET PIPING TO EXISTING PIPING IN reproduced, copied, loaned, or otherwise disposed of
CHASE. directly or indirectly, nor used for any purpose other than
20 EXTEND AND CONNECT NEW LAVATORY TO EXISTING PIPING IN CHASE. for which it is furnished, in whole or part.
21 2" SINK DRAIN OUTLET TO GREASE TRAP (GT-1). ROUTE GREASE TRAP OUTLET
DOWN THRU FLOOR AS INDICATED.
22 2" VENT DROP, 2" SANITARY DOWN THRU FLOOR.
23 EXISTING VENT UP TO EXISTING VENT THRU ROOF TO REMAIN.
24 2" VENT DOWN THRU FLOOR. COORDINATE EXACT LOCATION WITH WATER
TREATMENT EQUIPMENT.

1 2 3

23

A 1
STAFF TOILET A
(E)3" V (E)3" V (E)3" V FCO
EX. WC 2 3 EX. LAV EX. LAV 3 2 EX. WC WC-1A 19 113B
EX.FCO
EX.FCO TELECOM 21 S-2 16
4" EX.FD 6 GT-1
3 EX.LAV EX.LAV 3
DIRECTOR 111 L-1A 20

2" V
6 4" EX.FD OFFICE
4" EX.FD 6 OFFICE STAFF
1 109
2
110 113
EX. WC 2 EX. WC
WOMENS
4" FD-1P
107 EX.EWC-1 5
CONFERENCE MENS 14 CHANGING ROOM
EX. WC 2 108 4 EX.UR MB-1
102 JANITOR'S 113A
CLOSET
EX.FCO
112
EX.FCO

7 7 7

22
1
11
4" ST (E) 4" ST (E) 4" ST (E)
PAT. TOILET MED. PREP.
FCO
EEW-1
L-1A 114 115 3" V 3" V S-1
24 24
22
S-4 18
14 4" FD-1P
B 8
9 DB-1
B Holabird & Root, LLC expressly disclaims any
WC-2A SOILED STORAGE 2" V
responsibility arising from any unauthorized use of these
118 plans, drawings and notes. Any authorization must be in

3" V
10 4" FS-1
CORRIDOR 4" FS-1 4" EX.FD writing.
13
100B
This drawing copy may have been reproduced at a size
23

2" V
CLEAN SUPPLY different than originally drawn. The Owner and Architect
S-5 EX.FCO
S-1 12 WATER assume no responsibility for use of incorrect scale.
119 Drawings are not to be scaled.
EEW-1 TREATMENT
FCO
EXAM DB-1 125 24 Not published - All rights reserved.
1 106
2 1/2" V

DB-1 22
WAITING ROOM 7
DB-1 9
101

2 1/2" V
FCO
4" FS-1
10

EEW-2
11 4" FD-1P
NURSE STATION

3" ST (E)
116A
S-3 DB-1 S-4
EEW-1 8
DB-1
18 18
13 LAB
2" V 2" V S-4
121
14
C 8 EEW-2 C
16
2 09/13/2018 ADDENDUM 1
RECEPTION 1 09/07/2018 ISSUE FOR BID
S-5 12 12
No. Date Issue
105 4" ST (E) 4" ST (E) 4" ST (E)
4" EX.FD
DB-1 S-1 DB-1
STORAGE
122 Project Number 15849
7 7 7
Drawn FA
VESTIBULE
100A Checked FA

EX.FCO
Proj. Arch./Eng. FA
W.C.
DB-1 8
1
117A MECHANICAL
4" EX.AD
17
124
DIETITIAN
10
4" FD-1P
L-1A 18
Provident Hospital - Renal
103 ELECTRICAL Dialysis Center
SOCIAL WORKER 15
4" EX.FD
S-1 WC-2A 123
104 EX.FCO
EX.FCO 16 S-1
9 17
DB-1 DB-1 9 DB-1 15 DB-1

D 2" SAN 2" V 16 D

16 12 10

430 East 51st Place


Chicago, Illinois 60615
1 2 3
Project Name

LEVEL 01 - PLUMBING - STORM,


1 LEVEL 01 - PLUMBING - STORM, SANITARY & VENT PLAN
P0100 1/4" = 1'-0"
SANITARY & VENT PLAN
Sheet Name

Drawing No. P0100


PLUMBING GENERAL NOTES: PLUMBING KEYNOTES
1. SHUT-DOWN NOTICE IS REQUIRED FOR ANY SYSTEM SHUT-DOWNS. 1 EXISTING SANITARY UP TO EXISTING FIXTURE TO REMAIN.
PROVIDE A MINIMUM OF 72 HOURS NOTICE. 2 EXISTING SANITARY UP TO EXISTING PLUMBING CHASE TO REMAIN.
2. EXISTING SYSTEMS MUST BE PUT BACK INTO SERVICE AT THE END OF
EACH WORK DAY, INCLUDING COMPLETE VISUAL INSPECTION PRIOR TO 3 2" SANITARY UP THRU FLOOR.
THE CREW LEAVING FOR THE DAY. 4 3" SANITARY UP TO MOP BASIN WITH 2" VENT UP.
3. PLUMBING CONTRACTOR TO COORDINATE WITH THE MECHANICAL 5 4" SANITARY UP TO FLOOR DRAIN WITH 2" VENT UP.
CONTRACTOR REGARDING THE REROUTE/RAISING OF EXISTING PLUMBING 6 2" SANITARY UP WITH 2" VENT UP SERVING SINK.
PIPING IN ORDER TO ACCOMMODATE NEW DUCTWORK, MECHANICAL, 7 4" SANITARY UP TO FLOOR CLEANOUT.
ELECTRICAL AND FIRE PROTECTION SYSTEMS. THE EXTENT OF REROUTES
8 4" SANITARY UP TO WATER CLOSET WITH 2" VENT UP.
REQUIRED TO BE FIELD DETERMINED. REFER TO ARCHITECTURAL CEILING
PLAN. 9 EXISTING 3" VENT UP.
4. PLUMBING CONTRACTOR SHALL EMPLOY THE USE OF UNDERGROUND 10 EXISTING 6" STORM UP.
PIPING LOCATING EQUIPMENT IN ORDER TO PROPERLY LOCATE AND 11 EXISTING 3" STORM UP.
TRACE PIPING SYSTEMS. 12 4" SANITARY UP TO FLOOR SINK WITH 2" VENT UP.
5. PLUMBING CONTRACTOR SHALL SAWCUT SLAB AS REQUIRED TO
COMPLETE WORK. PLUMBING CONTRACTOR SHALL PATCH SLAB TO
MATCH EXISTING. Department of Capital Planning & Policy
6. ALL EQUIPMENT SHOWN ON PLAN IS NEW AND HAS BEEN OBTAINED FROM
THE OWNER\S EXISTING CONSTRUCTION DOCUMENTS. PLUMBING Bureau of Asset Management
CONTRACTOR SHALL FIELD VERIFY THE SIZE AND LOCATION OF ALL
EXISTING EQUIPMENT. Notice: This drawing has not been published and is the
sole property of Cook County. It is loaned to the borrower
for their confidential use only. In consideration of the loan
of this drawing, the borrower promises and agrees to
return it upon request and agrees that it shall not be
reproduced, copied, loaned, or otherwise disposed of
directly or indirectly, nor used for any purpose other than
for which it is furnished, in whole or part.

1 2 3

2 1 2 7 3

A A
1 4" SAN (E) 4" SAN (E)

2 1 1

1 9 5

1
4 1

4" SAN (E)


3
1 4" SAN (E) 7

4" SAN
10
3
12 1 12
5
B B Holabird & Root, LLC expressly disclaims any
4" SAN 8
responsibility arising from any unauthorized use of these
plans, drawings and notes. Any authorization must be in
3 writing.
4" SAN (E)

This drawing copy may have been reproduced at a size


4" SAN (E) 4" SAN (E) 4" SAN (E) 1
2" V different than originally drawn. The Owner and Architect
6 4" SAN assume no responsibility for use of incorrect scale.
3 7 Drawings are not to be scaled.

4" SAN
Not published - All rights reserved.
3
1 4" SAN (E)

(E)6" ST
12
7

4" SAN
5

3 11

10
(E)4" ST
4" SAN (E)

C C
2" V
3
2 09/13/2018 ADDENDUM 1
1 09/07/2018 ISSUE FOR BID
6 4" SAN
No. Date Issue

6
1 4" SAN
Project Number 15849
6" ST (E)

Drawn FA
1 Checked FA
4" SAN (E)

Proj. Arch./Eng. FA

5
4" SAN (E)

1
1 1

Provident Hospital - Renal


Dialysis Center
1 4" SAN (E) 4" SAN (E) 4" SAN (E) 4" SAN (E) 1
4" SAN

6" ST (E)

3
2" V
D 8 D

3 6 3

EXISTING 6" STORM TO EXISTING EXISTING 4" SANITARY TO EXISTING


SEWER TO REMAIN. SEWER TO REMAIN.
430 East 51st Place
Chicago, Illinois 60615
1 2 3
Project Name

UNDERGROUND PLUMBING
1 UNDERGROUND PLUMBING PLAN
P0100U 1/4" = 1'-0"
PLAN
Sheet Name

Drawing No. P0100U


PLUMBING GENERAL NOTES: PLUMBING KEYNOTES
1. SHUT-DOWN NOTICE IS REQUIRED FOR ANY SYSTEM SHUT-DOWNS. 1 3/4" REDUCED PRESSURE BACKFLOW PREVENTER (BFP) TO SERVE EXISTING
PROVIDE A MINIMUM OF 72 HOURS NOTICE. HUMIDIFIERS. ROUTE BFP DISCHARGE TO OVER NEAREST DRAIN RECEPTOR.
2. EXISTING SYSTEMS MUST BE PUT BACK INTO SERVICE AT THE END OF PROVIDE AIR GAP.
EACH WORK DAY, INCLUDING COMPLETE VISUAL INSPECTION PRIOR TO 2 EXISTING DOMESTIC WATER BOOSTER PUMP TO REMAIN.
THE CREW LEAVING FOR THE DAY.
3. PLUMBING CONTRACTOR TO COORDINATE WITH THE MECHANICAL 3 EXISTING 8" INCOMING DOMESTIC WATER / FIRE PROTECTION SERVICE ENTRY.
CONTRACTOR REGARDING THE REROUTE/RAISING OF EXISTING PLUMBING 4 EXISTING FIRE PROTECTION SERVICE TO EXISTING SYSTEM TO REMAIN.
PIPING IN ORDER TO ACCOMMODATE NEW DUCTWORK, MECHANICAL, 5 3/4" COLD WATER DROP, 3/4" HOT WATER DROP SERVING LAVATORY.
ELECTRICAL AND FIRE PROTECTION SYSTEMS. THE EXTENT OF REROUTES 6 3/4" COLD WATER DROP, 3/4" HOT WATER DROP SERVING SINK.
REQUIRED TO BE FIELD DETERMINED. REFER TO ARCHITECTURAL CEILING 7 3/4" COLD WATER DROP, 3/4" HOT WATER DROP SERVING MOP BASIN.
PLAN.
8 EXTEND AND CONNECT 3/4" COLD WATER TO EXISTING COLD WATER IN PLUMBING
4. PLUMBING CONTRACTOR SHALL EMPLOY THE USE OF UNDERGROUND
CHASE. 3/4" HOT WATER DROP SERVING LAVATORY.
PIPING LOCATING EQUIPMENT IN ORDER TO PROPERLY LOCATE AND
TRACE PIPING SYSTEMS. 9 3/4" COLD WATER, 3/4" HOT WATER AND 3/4" HOT WATER RETURN PIPING IN WALL.
5. PLUMBING CONTRACTOR SHALL SAWCUT SLAB AS REQUIRED TO ROUTE AS INDICATED TO SERVE SINK.
COMPLETE WORK. PLUMBING CONTRACTOR SHALL PATCH SLAB TO 10 3/4" TEMPERED WATER DROP.
MATCH EXISTING. 11 HOT WATER RETURN BALANCING STATION. REFER TO DETAIL ON SHEET P0600. Department of Capital Planning & Policy
6. ALL EQUIPMENT SHOWN ON PLAN IS NEW AND HAS BEEN OBTAINED FROM
THE OWNER\S EXISTING CONSTRUCTION DOCUMENTS. PLUMBING
12
13
1-1/4" COLD WATER DROP SERVING WATER CLOSET.
HOT WATER RETURN RECIRCULATING PUMP ASSEMBLY. REFER TO DETAIL ON
Bureau of Asset Management
CONTRACTOR SHALL FIELD VERIFY THE SIZE AND LOCATION OF ALL
SHEET P0600. Notice: This drawing has not been published and is the
EXISTING EQUIPMENT.
14 TEMPERED WATER RETURN RECIRCULATING PUMP ASSEMBLY. REFER TO DETAIL sole property of Cook County. It is loaned to the borrower
ON SHEET P0600.
15 MASTER THERMOSTATIC MIXING VALVE (TMV-1).
for their confidential use only. In consideration of the loan
16 EMERGENCY THERMOSTATIC MIXING VALVE (ETMV-1). of this drawing, the borrower promises and agrees to
17 FIELD VERIFY AND COORDINATE THERMOSTATIC MIXING VALVE INSTALLATION return it upon request and agrees that it shall not be
AND PIPE ROUTING WITH WATER TREATMENT EQUIPMENT INSTALLATION. reproduced, copied, loaned, or otherwise disposed of
18 WATER TREATMENT EQUIPMENT ROOM LAYOUT AND DISTRIBUTION SUPPLY AND directly or indirectly, nor used for any purpose other than
RETURN LOOP SHALL BE PROVIDED BY, INSTALLED AND COORDINATED WITH
WATER TREATMENT CONTRACTOR. DOMESTIC WATER SUPPLY TO WATER for which it is furnished, in whole or part.
TREATMENT EQUIPMENT IS SIZED FOR A 30 GPM DEMAND. PLUMBING
CONTRACTOR IS RESPONSIBLE FOR BACKFLOW PREVENTERS AS INDICATED AND
DISCHARGE DRAINAGE TO NEAREST DRAIN RECEPTOR. PROVIDE AIR GAP.

1 2 3

EX.NFWH EX.NFWH
6

A A
WC-1A S-2
EX. WC EX. LAV EX. LAV EX. WC
8 11
WOMENS MENS STAFF TOILET
EX.LAV EX.LAV
107 108 DIRECTOR L-1A 113B
OFFICE
OFFICE STAFF
109
CONFERENCE 110

3/4" HW-R
EX. WC 113

3/4" HW
EX. WC 7

2" CW (E)

3/4" CW
JANITOR'S
102 CLOSET
EX.EWC-1
3/4" (E)
TELECOM CHANGING ROOM
MB-1
112
EX. WC EX.UR 111 113A
2" CW (E) 2" CW (E) 2" CW (E) 2" CW (E)

1 1/2" CW 1 1/2" CW 1 1/2" CW


3/4" HW 1" HW 1" HW 1 1/4" HW
3/4" HW-R 3/4" HW-R 3/4" HW-R
6 3/4" TW 3/4" TW

3/4" HW-R
3/4" CW
3/4" HW
EEW-1
5 L-1A
6 16
S-4 S-1 BFP-2
B 12
ETMV-1 BFP-2 B Holabird & Root, LLC expressly disclaims any
CORRIDOR WC-2A
6 SOILED STORAGE responsibility arising from any unauthorized use of these
MED. PREP. 10 118 15 17
100B plans, drawings and notes. Any authorization must be in
9 115 1 1/4" HW writing.
TMV-1
3/4" HW-R

1 1/2" HW 140°
3/4" HW
3/4" CW

This drawing copy may have been reproduced at a size

3/4" HW-R
3/4" HW
3/4" TW

2" CW
different than originally drawn. The Owner and Architect

3/4" HW-R
CLEAN SUPPLY 14

3/4" TW

3/4" TW
S-5 10
WAITING ROOM S-1 assume no responsibility for use of incorrect scale.
6 119
101 Drawings are not to be scaled.
3/4" TW
3/4" TW WH-1 Not published - All rights reserved.
EXAM TWRP-1
106 DB-1 1 1/2" CW
3/4" HW-R

3/4" HW-R
3/4" TW
3/4" CW
HWRP-1

3/4" HW
EQUIP. REPAIR

3/4" HW-R
3/4" TW

3/4" HW
WATER

2" CW
11 NURSE STATION 10
EEW-2
120 13 TREATMENT
116A S-4
3/4" CW 125 18
3/4" HW
6 EEW-1 3/4" HW-R
S-3

3/4" TW 3/4" TW
9
LAB
11 6
10 6
121
C 10 S-4 C
EEW-2
2 09/13/2018 ADDENDUM 1
VESTIBULE RECEPTION
1 09/07/2018 ISSUE FOR BID

3/4" HW-R
6 6

3/4" HW
S-5

2" CW
100A 105 No. Date Issue
S-1 STORAGE
11
122
3/4" CW 3/4" CW 3/4" CW Project Number 15849
3/4" HW-R
Drawn FA
3/4" HW
1 1/4" CW 2" CW
Checked FA

EX.FCO
Proj. Arch./Eng. FA
W.C. 3/4" CW EX.NFWH

1 1/4" CW
8 3/4" HW-R
3/4" HW
BFP-1
3/4" CW (E)

117A 2" CW
1

DIETITIAN 5 Provident Hospital - Renal


SOCIAL WORKER L-1A 2
103
104
ELECTRICAL MECHANICAL Dialysis Center
S-1 123 124
6 11
9

8"
S-1
WC-2A 12
6 4

D D

8"
3 430 East 51st Place
Chicago, Illinois 60615
1 2 3
Project Name

LEVEL 01 - PLUMBING -
1 LEVEL 01 - PLUMBING - DOMESTIC WATER PLAN
P0200 1/4" = 1'-0"
DOMESTIC WATER PLAN
Sheet Name

Drawing No. P0200


PLUMBING KEYNOTES
1 VENT THRU ROOF. REFER TO SHEET P0100 FOR EXACT SIZE AND LOCATION.
2 EXISTING VENT THRU ROOF TO REMAIN.
3 PLUMBING CONTRACTOR SHALL DISCONNECT AND REMOVE EXISTING
PLANTER/FLOOR DRAIN. CUT AND CAP SANITARY PIPE IN FLOOR. PATCH FLOOR TO
MATCH EXISTING.

Department of Capital Planning & Policy


Bureau of Asset Management
Notice: This drawing has not been published and is the
sole property of Cook County. It is loaned to the borrower
for their confidential use only. In consideration of the loan
of this drawing, the borrower promises and agrees to
return it upon request and agrees that it shall not be
reproduced, copied, loaned, or otherwise disposed of
directly or indirectly, nor used for any purpose other than
for which it is furnished, in whole or part.

(E)3
" V

2" V
EX. WC
EX.FCO
1

EX. LAV
EX. WC
3 EX.LAV

3" V
4" EX.FD
3
EX. LAV (E)3
EX.EWC-1 " V
4" S
EX.FCO EX. WC AN EX.LAV
(E )
EX. WC
4" EX.FD
4" S

2" V
AN
(E ) EX. WC
1
3" V

3 V
"V 2"
2 1/2 1
EX.UR
L-1A

3" V
3" V
WC-2A V EX.FCO
) 4" S 3" 3" V
4" S (E A N
N
AN
(E SA 4" FD-1P 4" S

3" V
) 4" AN
(E )

2" V

2" V
1
2" V

WC-1A

2" V
V DB-1 "V L-1A
1/2

2" V
2" 2 S-4 4" EX.FD
4" EX.FD Holabird & Root, LLC expressly disclaims any
S-3 )
S-1 EEW-1 1
N
(E responsibility arising from any unauthorized use of these
" SA MB-1 2 plans, drawings and notes. Any authorization must be in
DB-1 4

2" V
EX.FCO writing.
4" FD-1P
4" S
AN N
SA This drawing copy may have been reproduced at a size
2" S-5
3 4" S different than originally drawn. The Owner and Architect
AN
1 2" V
V
DB-1
L-1A
assume no responsibility for use of incorrect scale.
2" 2" V GT-1 Drawings are not to be scaled.
)
(E (E
) S-1
2" V

N DB-1 FCO S-2


" SA 4" S SA
N
4 AN " Not published - All rights reserved.
EX.FCO 4

2" V
S-5 V
DB-1 EEW-1 2"
2" V

1 4" S
N AN (
SA E ) DB-1
2"
S-1 DB-1
4" S DB-1
AN

3" V
2" V

2" V
V

2" V
(E )
A N 2"
4 "S
S-1 DB-1 4" S
AN (
S-4 E )
4" S

2" V
AN
2" V

V
2"
2" V

N
N SA
DB-1 2" V DB-1 SA 4"
2"

2" V
4" S
AN ( EEW-1 4" FS-1

2" V
EX.FCO 4" FD-1P E
2" S )
AN S-4
4" EX.FD
1 1/2" V

DB-1 EEW-2 2 09/13/2018 ADDENDUM 1


2" V

1 09/07/2018 ISSUE FOR BID


2 4" FS-1
DB-1 EX.FCO No. Date Issue
)
(E S-1
N
SA L-1A

(E)3" V
4"
4" FD-1P 4" S
A N FCO Project Number 15849
4" S
AN (
E
FCO Drawn FA
)
WC-2A Checked FA
4" FS-1
Proj. Arch./Eng. FA

4" EX.FD )
4" S (E 2" V
V
AN (
E ) 2" (E)
4" EX.AD
Provident Hospital - Renal
EX.FCO Dialysis Center

SANITARY WASTE AND VENT RISER DIAGRAM


1
430 East 51st Place
Chicago, Illinois 60615

Project Name

SANITARY WASTE AND VENT


RISER DIAGRAM
Sheet Name

Drawing No. P0400


PLUMBING KEYNOTES
1 EXTEND AND CONNECT 3/4" COLD WATER TO EXISTING HUMIDIFIERS. FIELD
VERIFY AND COORDINATE EXACT POINT OF NEW CONNECTION.
2 FIELD VERIFY AND COORDINATE THERMOSTATIC MIXING VALVE INSTALLATION
AND PIPE ROUTING WITH WATER TREATMENT EQUIPMENT INSTALLATION.

11
/4"
3 (2) REDUCED PRESSURE ZONE (RPZ) BACKFLOW PREVENTERS SERVING THE

HW
3/4
WATER TREATMENT EQUIPMENT. ROUTE RPZ DISCHARGE TO OVER FLOOR DRAIN.

3/4
"
PROVIDE AIR GAP. EXTEND AND CONNECT 1-1/2" COLD WATER AND 1-1/2" HOT

TW

"TW
WATER TO WATER TREATMENT EQUIPMENT. REFER TO MANUFACTURER'S AND
WATER TREATMENT CONTRACTOR'S INSTALLATION REQUIREMENTS.

11
4 EXISTING INCOMING WATER SERVICE AND DOMESTIC WATER BOOSTER PUMP TO

/2"
3/4
TWRP-1 REMAIN. EXISTING 2" COLD WATER MAIN TO BE REUSED AS INDICATED. FIELD

"

CW
HW
VERIFY AND COORDINATE SELECTIVE DEMOLITION.

-R
CW
1 1/2" 5 3/4" COLD WATER, 3/4" HOT WATER AND 3/4" HOT WATER RETURN PIPING IN WALL.
ROUTE AS INDICATED TO SERVE SINK.

HWRP-1
6
7
HOT WATER RETURN BALANCING STATION. REFER TO DETAIL ON SHEET P0600.
HOT WATER RETURN RECIRCULATING PUMP ASSEMBLY. REFER TO DETAIL ON
Department of Capital Planning & Policy
SHEET P0600. Bureau of Asset Management

1 1/2" HW
1 1/2" CW
8 TEMPERED WATER RETURN RECIRCULATING PUMP ASSEMBLY. REFER TO DETAIL
ON SHEET P0600. Notice: This drawing has not been published and is the
9 3/4" REDUCED PRESSURE BACKFLOW PREVENTER (BFP) TO SERVE EXISTING sole property of Cook County. It is loaned to the borrower

HW 14 HUMIDIFIERS. ROUTE BFP DISCHARGE TO OVER NEAREST DRAIN RECEPTOR.
1 1/2"

1 1/2" HW
PROVIDE AIR GAP. for their confidential use only. In consideration of the loan
of this drawing, the borrower promises and agrees to

1/2" TW
return it upon request and agrees that it shall not be
reproduced, copied, loaned, or otherwise disposed of
directly or indirectly, nor used for any purpose other than
for which it is furnished, in whole or part.

3/4" HW-R

1 1/2" CW
BFP-2

2 TMV-1 2 ETMV-1
EEW-1

BFP-2
3

EX.WC ) 4" FS-1


(E
W
"C
2" C
W (E 3 /4
)
EX. LAV
WH-1
EX.LAV
EX.LAV
3/4"
(E)
EX. WC
EX.LAV
2" C
W (E
EX. WC )
EX. WC
W
"C W
1 1 /2 ENLARGEMENT - WATER TREATMENT DOMESTIC WATER SUPPLY
3 / 4
"H
EX.EWC-1
3/4"
HW
" CW 2
3 /4 3/4"
HW-
-R R
" HW
3 /4
EX. WC

EX.UR
6

2" C
W (E
L-1A )
1 1 /2
"C
1" H W
6 3/4" W
HW-
3/4" R
WC-2A TW

WC-1A 6

1 W MB-1
"C 2" C
3 /4 W W (E
)
"H
S-3 3/4 W-R L-1A -R
1 "H S-4 1 1 /2 " HW
3 /4 1 1/4 " CW 3 /4 " H W
W
Holabird & Root, LLC expressly disclaims any
3/4" HW
" 3 /4 " C
5 HW- 3 /4 responsibility arising from any unauthorized use of these
3/4" R
EEW-1
TW plans, drawings and notes. Any authorization must be in
S-1
writing.
" TW
3 /4
3/4"
CW
This drawing copy may have been reproduced at a size
different than originally drawn. The Owner and Architect
S-5 assume no responsibility for use of incorrect scale.
Drawings are not to be scaled.
S-2
W W
"C / 4"T R Not published - All rights reserved.
3 /4 3 -
" HW W
6 3/4"
T W S-1 3/4 /4" H
1 1 CW
2"
)
(E
W
/ 4"C 6
3
1 1 /4
" HW
S-5 5 3/4"
CW
3/4"
CW
3/4"
HW
3/4" 3/4"
T W HW- 8 TWRP-1
DB-1 R 3/4"
EEW-1 T W

W
"T
S-1 3 /4 3/4" 1 1 /2
H W-R " CW 0°
EEW-2 14
S-4 HW
/2" 2 09/13/2018 ADDENDUM 1
11
-R 7 HWRP-1
BFP-2
1 09/07/2018 ISSUE FOR BID
" HW W 3/4"
CW
S-1 3/4 /4" H CW No. Date Issue
3
/4"
11
3/4" CW (E)

3/4" -R TMV-1
3/4"
HW-
R " HW W
H
H 3/4 /4" ETMV-1
6 1 1 /4 W 3 CW
" CW 2" Project Number 15849
5 BFP-2
Drawn FA
REFER TO
EEW-1
ENLARGEMENT ON Checked FA
EEW-2 THIS SHEET
Proj. Arch./Eng. FA

WH-1

Provident Hospital - Renal


EX.NFWH 4
Dialysis Center
S-1
3/4" CW

3/4" CW

L-1A

WC-2A

9 BFP-1

430 East 51st Place


Chicago, Illinois 60615

EX.NFWH
Project Name

DOMESTIC WATER AND


TEMPERED WATER RISER
DOMESTIC WATER AND TEMPERED WATER RISER DIAGRAM DIAGRAM
1 Sheet Name

Drawing No. P0401


DOMESTIC FIXTURE SCHEDULE
GENERAL PLUMBING FIXTURE NOTES:
1. SEE ARCHITECTURAL PLANS AND DETAILS FOR FLUSH COLD HOT
PLUMBING FIXTURE MOUNTING HEIGHTS. TRIM FIXTURE WASTE VENT WATER WATER
2. FLUSH HANDLE ON ALL A.D.A. COMPLIANT WATER MOTION SENSOR VOL. PER ROUGH-IN PIPE ROUGH-IN ROUGH-IN
CLOSETS SHALL BE ON THE "WIDE" SIDE OF THE TAG QTY DESCRIPTION MANUFACTURER MODEL MATERIAL DESCRIPTION FINISH MANUFACTURER MODEL TYPE CONTROL FLUSH PIPE SIZE SIZE PIPE SIZE PIPE SIZE SPECIFICATION REMARKS
TOILET ROOM. COORDINATE WITH ARCHITECTURAL L-1A 3 LAVATORY - WALL HUNG - ADA TOTO LHT242.8G WHITE VITREOUS CHINA WHITE CHICAGO FAUCET CO 1100-E35-317ABCP MANUAL No 2” 1-1/2” 1/2” 1/2” WALL HUNG LAVATORY, ADA COMPLIANT, REAR OVERFLOW, CEFIONTECT. FAUCET: DECK MOUNTED, 8: FIXED CENTERS,
DETAILS AND VERIFY IN FIELD. 1.5 GPM AERATOR, 4" VANDAL PROOF WRISTBLADE, QUATURN, ECAST. EXTERNAL ASSE 1070 COMPLIANT
3. FURNISH AND INSTALL ASSE 1016 THERMOSTATIC THERMOSTATIC MIXING VALVE, GRID DRAIN, LOOSE KEY ANGLE STOPS AND SUPPLIES. INSULATE WATER AND WASTE
MIXING VALVE TO LIMIT HOT WATER DISCHARGE WITH ADA INSULATION KIT. MOUNT AT ADA COMPLIANT HEIGHT.
TEMPERATURE TO 110°F MAX. FOR LAVATORIES AND
SINKS AT JOB COMPLETION. PIPE PER
MB-1 1 MOP BASIN CREATIVE INDUSTRIES VENETIAN MC3624-612-1SS PRECAST TERRAZZO TERRAZZO CHICAGO FAUCET CO 911-ISCP MANUAL No 3” 2” 3/4” 3/4” MOP BASIN - FAUCET: WALL MOUNTED, 8" BODY, VACUUM BREAKER SPOUT, WALL BRACE, 3/4" MALE THREAD HOSE, Department of Capital Planning & Policy
PAIL HOOK, 4" VANDAL PROOF LEVER, INTEGRAL CHECK VALVES, INTEGRAL STOP VALVES. PROVIDE FIAT: HOSE AND
MANUFACTURER AND FAUCET TYPE
SPECIFICATIONS. FURNISH AND INSTALL LEAD-FREE
HOSE BRACKET (832-AA), MOP HANGER (889-CC), SILICONE SEALANT (833-AA), STAINLESS STEEL BUMPERGUARD Bureau of Asset Management
(E-88-AA), STAINLESS STEEL WALL GUARD (MSG2424).
THERMOSTATIC MIXING VALVE, WATTS LFUSG-B-M2. Notice: This drawing has not been published and is the
4. A.D.A. COMPLIANT STAINLESS STEEL SINKS TO HAVE
S-1 6 SINGLE BOWL SINK TOTO LHT242.8G WHITE VITREOUS CHINA WHITE CHICAGO FAUCET CO 1100-E35-317ABCP MANUAL No 2” 2” 1/2” 1/2” WALL HUNG LAVATORY, ADA COMPLIANT, REAR OVERFLOW, CEFIONTECT. FAUCET: DECK MOUNTED, 8: FIXED CENTERS,
"OFF-CENTERED REAR" DRAIN OPENING.
1.5 GPM AERATOR, 4" VANDAL PROOF WRISTBLADE, QUATURN, ECAST. EXTERNAL ASSE 1070 COMPLIANT sole property of Cook County. It is loaned to the borrower
5. PROVIDE A CONTINUOUS PLASTIC SLEEVE THERMOSTATIC MIXING VALVE, GRID DRAIN, LOOSE KEY ANGLE STOPS AN for their confidential use only. In consideration of the loan
ENCASEMENT PER CODE SECTION 18-29-420.3. S-2 1 SINGLE BOWL SINK ELKAY LRAD1918-55-3 STAINLESS STEEL LUSTERTONE CHICAGO FAUCET CO 1100-E35-317ABCP MANUAL No 2” 2” 1/2” 1/2” SINGLE COMPARTMENT, ADA COMPLIANT, TOP MOUNT, 16"x11-1/2"x5-3/8" DEEP BOWL, 18 GAUGE, REAR CENTER DRAIN,
3-HOLE. FAUCET: DECK MOUNTED, 8: FIXED CENTERS, 1.5 GPM AERATOR, 4" VANDAL PROOF WRISTBLADE, QUATURN,
of this drawing, the borrower promises and agrees to
COORDINATE WITH ARCHITECT.
6. INSTALL VACUUM BREAKER@7'-6". VERIFY IF ECAST. ONE ELKAY MODEL NO. LK35 BASKET STRAINER, P-TRAP, TAILPIECES, SUPPLIES AND STOPS. INSULATE WATER return it upon request and agrees that it shall not be
REQUIRED BY LOCAL CODE. AND WASTE TO MEET ADA REQUIREMENTS. reproduced, copied, loaned, or otherwise disposed of
7. FURNISH AND INSTALL McGUIRE 8903, 1-1/2", CAST S-3 1 DOUBLE BOWL SINK ELKAY BPSR2317 STAINLESS STEEL BRILLIANT SATIN CHICAGO FAUCET CO 1100-E35-317ABCP MANUAL No 2” 2” 1/2” 1/2” DOUBLE COMPARTMENT, ADA COMPLIANT, TOP MOUNT, 9-1/4"x12"x6" DEEP BOWL (EACH), 20 GAUGE, CENTER DRAIN. directly or indirectly, nor used for any purpose other than
BRASS BODY, CHROME PLATED P-TRAP WITH FAUCET: DECK MOUNTED, 8: FIXED CENTERS, 1.5 GPM AERATOR, 4" VANDAL PROOF WRISTBLADE, QUATURN, ECAST.
CLEANOUT PLUG AND ESCUTCHEON. ONE ELKAY MODEL NO. LK35 BASKET STRAINER, P-TRAP, TAILPIECES, SUPPLIES AND STOPS. INSULATE WATER AND
for which it is furnished, in whole or part.
8. FURNISH AND INSTALL McGUIRE H2165LK, HEAVY WASTE TO MEET ADA REQUIREMENTS.
DUTY ANGLE SUPPLY STOP, BRASS BODY, CHROME S-4 3 SINGLE BOWL SINK ELKAY LRAD1918-55-3 STAINLESS STEEL LUSTERTONE CHICAGO FAUCET CO 1100-E35-317ABCP MANUAL No 2” 2” 1/2” 1/2” SINGLE COMPARTMENT, ADA COMPLIANT, TOP MOUNT, 16"x11-1/2"x5-3/8" DEEP BOWL, 18 GAUGE, REAR CENTER DRAIN,
PLATED WITH ESCUTCHEON, CHROME PLATED 3-HOLE. FAUCET: DECK MOUNTED, 8: FIXED CENTERS, 1.5 GPM AERATOR, 4" VANDAL PROOF WRISTBLADE, QUATURN,
COPPER TUBE RISER, BRASS STEM, LOOSE KEY. ECAST. ONE ELKAY MODEL NO. LK35 BASKET STRAINER, P-TRAP, TAILPIECES, SUPPLIES AND STOPS. INSULATE WATER
9. FURNISH AND INSTALL PROWRAP PW2000, AND WASTE TO MEET ADA REQUIREMENTS.
INSULATING KIT FOR TAILPIECE, P-TRAP, OFFSET
DRAIN, WALL BEND, AND 2 SUPPLY COVERS. S-5 2 SINGLE BOWL SINK ELKAY LRAD1918-55-3 STAINLESS STEEL LUSTERTONE CHICAGO FAUCET CO 1100-E35-317ABCP MANUAL No 2” 2” 1/2” 1/2” SINGLE COMPARTMENT, ADA COMPLIANT, TOP MOUNT, 16"x11-1/2"x5-3/8" DEEP BOWL, 18 GAUGE, REAR CENTER DRAIN,
3-HOLE. FAUCET: DECK MOUNTED, 8: FIXED CENTERS, 1.5 GPM AERATOR, 4" VANDAL PROOF WRISTBLADE, QUATURN,
ECAST. ONE ELKAY MODEL NO. LK35 BASKET STRAINER, P-TRAP, TAILPIECES, SUPPLIES AND STOPS. INSULATE WATER
AND WASTE TO MEET ADA REQUIREMENTS.
WC-1A 1 WATER CLOSET - WALL HUNG - ADA AMERICAN STANDARD AFWALL 3351.101.020 WHITE VITREOUS CHINA WHITE AMERICAN STANDARD 6065.111.02 BATTERY Yes 1.1 gal 4” 2” 1” ELONGATED WALL MOUNTED WATER CLOSET, 1-1/2” TOP SPUD, HIGH EFFICIENCY. FLUSH VALVE: EXPOSED, SENSOR
OPERATED SELECTRONIC, CR-P2 BATTERY, DEZINCIFICATION RESISTANT, FULL MECHANICAL MANUAL OVERRIDE. SEAT:
AMERICAN STANDARD 5901.100 OR EQUAL. INSTALL AT ADA COMPLIANT HEIGHT.
WC-2A 2 WATER CLOSET - FLOOR MOUNT - AMERICAN STANDARD FLOWISE 3641.001 WHITE VITREOUS CHINA WHITE AMERICAN STANDARD 6065.111.02 BATTERY Yes 1.1 gal 4” 2” 1” ELONGATED FLOOR MOUNTED WATER CLOSET, 1-1/2” TOP SPUD, HIGH EFFICIENCY. FLUSH VALVE: EXPOSED, SENSOR
BARIATRIC - ADA OPERATED SELECTRONIC, CR-P2 BATTERY, DEZINCIFICATION RESISTANT, FULL MECHANICAL MANUAL OVERRIDE. SEAT:
AMERICAN STANDARD 5901.100 OR EQUAL. INSTALL AT ADA COMPLIANT HEIGHT.
Grand total: 20

EMERGENCY EYEWASH SCHEDULE


WASTE VENT TW
TAG QTY DESCRIPTION MANUFACTURER MODEL MATERIAL DESCRIPTION FINISH SIZE SIZE SIZE SPECIFICATION REMARKS
EEW-1 3 WALL MOUNT HALO EYEWASH BRADLEY S19224DCPT STAINLESS STEEL STAINLESS STEEL 2” 2” 1/2” ADA COMPLIANT, STAINLESS STEEL PUSH HANDLE ACTIVATION, CORROSION RESISTANT BOWL AND BOWL DUST COVER,
CHROME PLATED P-TRAP, HALO EYEWASH SYSTEM, INTEGRAL FLOW CONTROL.
EEW-2 2 SWING DOWN EYEWASH BRADLEY S19-280D BRASS CHROME PLATED --- --- 1/2” ADA COMPLIANT, SWING DOWN ACTIVATION, DECK MOUNTED, VANDAL RESISTANT CERAMIC VALVE, TWIN SOFT-FLOW
EYEWASH HEADS AND PROTECTIVE SPRAYHEAD COVERS, INTEGRAL FLOW.
Grand total: 5

GAS-FIRED WATER HEATER SCHEDULE


GAS-FIRED HEAT EXCHANGER ELECTRICAL
GAS BURNER WATERSIDE
FUEL STORAGE MAX TEMP UNIT
TAG MANUFACTURER MODEL NO. TYPE INPUT STAGES TYPE PRESS AVAIL RECOVERY VOL RISE THERMAL EFF WEIGHT FLA VOLT PH REMARKS
WH-1 AO SMITH BTH-120 Mxi CONDENSING 120000.0 Btu/h 2 NG 2.0 psi 138 gal/h 60.0 gal 100 °F 95% 991.00 lbf 6A 120 V 1 PROVIDE CONCENTRIC VENT KIT. PROVIDE CONDENSATE NEUTRALIZATION KIT.

Holabird & Root, LLC expressly disclaims any


responsibility arising from any unauthorized use of these
plans, drawings and notes. Any authorization must be in
writing.
DOMESTIC CIRCULATING PUMP SCHEDULE
MOTOR This drawing copy may have been reproduced at a size
TAG MANUFACTURER MODEL NO. SERVICE GPM WATTS VOLTAGE PHASE RPM REMARKS different than originally drawn. The Owner and Architect
HWRP-1 BELL & GOSSETT NRF-9F/LW TEMPERED WATER 2 GPM 41 W 120 V 1 2800 assume no responsibility for use of incorrect scale.
RECIRCULATION Drawings are not to be scaled.
TWRP-1 BELL & GOSSETT NRF-9F/LW HOT WATER RECIRCULATION 4 GPM 41 W 120 V 1 2800
Not published - All rights reserved.

FLOOR DRAIN SCHEDULE


MATERIAL DESCRIPTION WASTE VENT PRIMER
TAG QTY DESCRIPTION MANUFACTURER MODEL DRAIN BODY STRAINER PIPE SIZE PIPE SIZE PIPE SIZE SPECIFICATION REMARKS
FCO 3 FLOOR CLEANOUT WATTS CO-200-R-4-X-6 EPOXY COATED CAST IRON EPOXY COATED CAST IRON FLOOR CLEANOUT, REMOVEABLE GAS TIGHT GASKETED BRASS
CLEANOUT PLUG, INSIDE CAULK, VANDAL PROOF.
FD-1 4 FLOOR DRAIN WATTS FD-1100-A-X EPOXY COATED CAST IRON NICKEL BRONZE 4” 2” 1/2 in EPOXY COATED CAST IRON FLOOR DRAIN WITH ANCHOR FLANGE, REVERSIBLE CLAMPING PROVIDE DEEP SEAL P-TRAP.
COLLAR WITH PRIMARY & SECONDARY WEEPHOLES, ADJUSTABLE ROUND HEEL PROOF NICKEL
BRONZE STRAINER, INSIDE CAULK.
FS-1 3 FLOOR SINK WATTS FS-730-150 EPOXY COATED CAST IRON ALUMINUM 4” 2” --- 12" SQUARE X 6" DEEP SANITARY FLOOR SINK WITH WHITE PORCELAIN ENAMEL COATED PROVIDE DEEP SEAL P-TRAP.
INTERIOR, 1/2 GRATE, ALUMINUM DOME BOTTOM STRAINER.
Grand total: 10

2 09/13/2018 ADDENDUM 1
1 09/07/2018 ISSUE FOR BID
No. Date Issue
BACKFLOW PREVENTER SCHEDULE
TAG COUNT SIZE DESCRIPTION SERVICE MANUFACTURER MODEL SPECIFICATION
BFP-1 1 3/4" REDUCED PRESSURE MECH. HUMIDIFIERS ZURN WILKINS 375XL-AG LEAD FREE, FULL PORT, QUARTER TURN BALL VALVE, BRONZE STRAINER. ROUTE RPZ Project Number 15849
ZONE ASSEMBLY DISCHARGE TO OVER NEAREST DRAIN RECEPTOR. PROVIDE AIR GAP.
BFP-2 2 1 1/2" REDUCED PRESSURE WATER TREATMENT ZURN WILKINS 375XL-AG LEAD FREE, FULL PORT, QUARTER TURN BALL VALVE, BRONZE STRAINER. ROUTE RPZ Drawn FA
ZONE ASSEMBLY DISCHARGE TO OVER NEAREST DRAIN RECEPTOR. PROVIDE AIR GAP.
Grand total: 3 Checked FA
Proj. Arch./Eng. FA

THERMOSTATIC MIXING VALVE SCHEDULE


FLUID PROPERTIES VALVE PROPERTIES
INLET OUTLET Provident Hospital - Renal
TAG QTY DESCRIPTION MANUFACTURER MODEL SET TEMP. FLOW DIAMETER DIAMETER SPECIFICATION
ETMV-1 1 EMERGENCY THERMOSTATIC MIXING VALVE GUARDIAN G3602LF 85 °F 6 GPM 1/2" 1/2" VALVE IS EQUIPPED WITH INTERNAL FAIL SAFE. Dialysis Center
TMV-1 1 MASTER THERMOSTATIC MIXING VALVE LEONARD TM-520B-LF-DT-IT 120 °F 50 GPM 3/4" 1" ECO-MIX, LOCKING TEMPERATURE REGULATORS, ADJUSTABLE HIGH TEMPERATURE
LIMIT STOP, INLET CHECKSTOPS, WALL SUPPORT, OUTLET BALL VALVE, INLET
THERMOMETERS.
Grand total: 2

GREASE INTERCEPTOR SCHEDULE


ID
TYPE QTY MANUFACTURER MODEL DESCRIPTION
GT-1 1 ROCKFORD RP-1 4 GPM INTERMITTENT FLOW, 18 LBS GREASE CAPACITY 430 East 51st Place
SEPARATORS
Chicago, Illinois 60615
Grand total: 1

Project Name

SCHEDULES

Sheet Name

Drawing No. P0500


FLOW
FOR CONTINUATION AND
SIZE, SEE FLOOR PLAN
CAST IRON CLEANOUT WITH CAST IRON CLEANOUT WITH
COVER FOR DUTY REQURIED COVER FOR DUTY REQURIED
GATE (OR BALL) VALVE "CO" TO BE
TAPERED BODY TAPERED BODY
CAST IN COVER
LEAD LEAD
6" THICK X 18" SQUARE
AQUASTAT FOR CONTROL CONCRETE PAD GRADE OR PAVING FINISHED FLOOR
2" VENT UP OF PUMP
GAUGE COCK
Department of Capital Planning & Policy
OAKUM OAKUM
IN-LINE RECIRCULATING
PUMP (SEE PUMP SCHEDULE)
Bureau of Asset Management
Notice: This drawing has not been published and is the
COUNTER sole property of Cook County. It is loaned to the borrower
CAST IRON SOIL PIPE CAST IRON SOIL PIPE for their confidential use only. In consideration of the loan
SINK
DIAL TYPE PRESSURE GAUGE of this drawing, the borrower promises and agrees to
CAST IRON LONG SWEEP 1/4
2" VENT (0-100 PSIG) BEND OR CAST IRON return it upon request and agrees that it shall not be
ADJUSTABLE TOP
TO BE FLUSH WITH FINAL FINISH FLOOR COMBINATION "Y" & 1/8 BEND reproduced, copied, loaned, or otherwise disposed of
UNION (USE REDUCING TYPE WHERE directly or indirectly, nor used for any purpose other than
REQUIRED)
COLLAR CAN BE USED for which it is furnished, in whole or part.
AS FLASHING CLAMP REDUCING TEE (OR TEST PLUG
2" FUNNEL MAT FINISH
FOR INSERTION OF GAUGE)
CALIBRATED BALANCING VALVE
NOTE: CLEANOUTS SHALL BE
CHECK VALVE FLOW INSTALLED EVERY 45 TO 50 FEET FLOW
2" SINK WASTE IN WALL ON THE HORIZONTAL RUN
BEHIND SINK CABINET TO BUILDING DRAIN OR TO BUILDING DRAIN OR
2" WASTE
SEWER. SEWER.
MATERIAL AND SIZE AS MATERIAL AND SIZE AS
SPECIFIED SPECIFIED
FLOOR EXTERIOR CLEANOUT INTERIOR FLOOR CLEANOUT
(LIGHT TRAFFIC AREA)

DETAIL DETAIL DETAIL DETAIL


4 N.T.S.
FUNNEL DRAIN DETAIL
3 N.T.S.
FLOOR DRAIN WITH ADJUSTABLE TOP
2 N.T.S.
DOMESTIC WATER RECIRCULATING PUMP
1 N.T.S.
CLEANOUT DETAIL

WATER INLET WATER OUTLET

WALL PIPE REDUCED PRESSURE 3/4" GAUGE READING FLOW


WALL PIPE SUPPORT
SUPPORT BACKFLOW PREVENTER CONTROL SET AT 0.5 GPM

HOLD HORIZONTAL DRAIN, 3/4" CHECK VALVE 3/4" BALL VALVE


VENT AND WATER PIPING 3/4" BALL VALVE
IN FOOD SERVICE MIN 6"
ABOVE FLOOR TO ALLOW
FLOOR CLEANING 3/4" HWR FROM FIXTURES 3/4" HWR TO WATER HEATER
HALF GRATE
flow
2" AIR GAP UNION
FINISHED FLOOR, VERIFY
FLOOR STRAINER 4'-0" 3/4" UNION 3/4" UNION
COVERING THICKNESS DRAIN BALL VALVE OFF FLOOR
INTERNAL DOME
STRAINER AIR GAP
DETAIL
1" TO NEAREST
FLOOR DRAIN
5 N.T.S.
HWR BALANCING STATION DETAIL

DETAIL DETAIL
7 N.T.S.
FLOOR SINK
6 N.T.S.
BACKFLOW PREVENTER DETAIL

COUNTER TOP
2" COLUMN
OR WALL

Holabird & Root, LLC expressly disclaims any


ESCUTCHEON responsibility arising from any unauthorized use of these
SINK
plans, drawings and notes. Any authorization must be in
SLIP JOINT INSTALL VENT AT UNDERSIDE writing.
NUT OF COUNTER TOP
1-1/2" WALL CLEANOUT This drawing copy may have been reproduced at a size
2" SLOPE VENT
CO CO 2"
different than originally drawn. The Owner and Architect
WATER SAVER @1/4" PER FT FLOOR
assume no responsibility for use of incorrect scale.
TRAP PRIMER
OFFSET Drawings are not to be scaled.
2" VENT TO
COLUMN Not published - All rights reserved.
OR WALL
BRAIDED
PRIMER VENT LOOP TO EXTEND
ESCUTCHEON HOSE ABOVE FLOOD RIM OF HAND
CLEANOUT SINK
RUN VENT TO PARTITION
OR COLUMN AS SHOWN
COMPRESSION ENCLOSURE - SEE ON PLANS
PIPE FITTING ARCHITECTURAL PLANS
WALL
HUB CLEANOUT
ALL THREAD
HANGER ROD.
SUPPORT UNINSULATED PIPE P-TRAP WITH FLOOR LINE
FROM CLEANOUT
CLEANOUT PLUG
STRUCTURE* LAVATORY
INSULATION
INSULATION
WALL ACCESS COVER
PIPE
AND FRAME
PIPE SLOPE VENT AT 1/4" 2 09/13/2018 ADDENDUM 1
SPIGOT 30" WALL CHASE
WELD PER FOOT
1 09/07/2018 ISSUE FOR BID
WALL WATER SAVER
TRAP PRIMER No. Date Issue
CALCIUM SILICATE STEEL PIPE SHOE ON FLOOR SLOPE WASTE LINE AT
TRAP PRIMER
INSULATION ON PIPES ABOVE 4" SIZE 1/4" PER FOOT
LINE DOWN TO TRAP
INSUL. PIPE TO 4" SIZE (12" MIN LENGTH) OF FLOOR DRAIN FLOOR DRAIN
SUPPORT
SUPPORT NUT CHANNEL OR USE LONG SWEEP ELL AND 45 Project Number 15849
WHEN CO OCCURS AT END OF
DETAIL
8
ANGLE FLOOR SLAB ISLAND VENT PIPING DETAIL
LOCKING NUT LINE. SEAL SEALANT (TYP.) Drawn FA
ROLLER AND STAND ON N.T.S.
16 GA. GALVANIZED SHEET PIPING ABOVE 60° F Checked FA
METAL INSULATION
PROTECTION SHIELD- 12" * PROVIDE CONCRETE INSERTS OR FASTEN TO TOP
CHORDS AT BAR JOISTS OR OTHER STRUCTURAL
BOLT PIPE ROLLERS Proj. Arch./Eng. AJG
MIN. LENGTH ON PIPE
TO CHANNEL
BELOW 60° F BEAMS. DO NOT FASTEN TO ROOF DECK OR JOIST DEEP SEAL
FLOW
BRIDGING. CONNECTION TO TRAP P-TRAP

SLEEVES AND ESCUTCHEONS


DETAIL DETAIL DETAIL
11 N.T.S.
TRAPEZE PIPE HANGER DETAIL
10 N.T.S.
WALL CLEAN OUT DETAIL
9 N.T.S.
VALVE-LESS TRAP PRIMER DETAIL - TOILET ROOMS

STANDARD WEIGHT
TERMINATE SLEEVE FLUSH
A. SLEEVES FOR PIPING THROUGH MASONRY WALLS SHALL BE
SCHEDULE 40, STANDARD GALVANIZED STEEL PIPE; IN FRAMED
PARTITIONS SHALL BE 20 GAUGE SHEET METAL. THE SPACE
Provident Hospital - Renal
Dialysis Center
STEEL PIPE SLEEVE TO
WITH FINISHED WALL BETWEEN THE PIPE AND ITS SLEEVE SHALL NOT EXCEED ONE-
PASS PIPE
SURFACES HALF INCH. THE SLEEVE SHALL HAVE A SUFFICIENT LENGTH TO BE
FLUSH WITH THE FINISHED WALL SURFACE.
TERMINATE SLEEVE FLUSH B. EXPOSED PIPING PASSING THROUGH WALLS, FLOORS OR CEILING
WITH FINISHED WALL SHALL BE FITTED WITH CHROMIUM-PLATED CAST BRASS
SURFACES ESCUTCHEONS WITH FASTENING SET SCREWS.
PIPE SLEEVE
SEALANT (SEE SPEC.)
CUTTING AND PATCHING
FINISHED ESCUTCHEON A. PIPING PASSING THROUGH WALLS SHALL HAVE A TRIM OPENING
PLATE FLUSH AGAINST WALL CUT NO GREATER THAN NECESSARY FOR THE INSTALLATION OF A
SEAL OR CAULK SLEEVES AND OF SIZE TO SLEEVE SECURED THEREIN.
COMPLETELY COVER B. PIPING PASSING THROUGH CONCRETE FLOORS SHALL HAVE AN
THRU FIRE WALLS IN A
OPENING CORE DRILLED SO THAT THE SPACE BETWEEN THE
430 East 51st Place
SMOKE TIGHT MANNER. OPENING
FINISHED (TYP.
WALLFOR EACH
SURFACE
SIDE) OPENING AND THE PIPE SHALL NOT EXCEED ONE-HALF INCH. Chicago, Illinois 60615
REFER TO SPECS.
FINISHED ESCUTCHEON C. ANNULAR SPACES BETWEEN PIPING AND SLEEVES OR CORE
PIPE AND INSULATION TO PLATE FLUSH AGAINST DRILLED FLOOR OPENINGS SHALL BE PACKED WITH MINERAL
BE CENTERED IN SLEEVE WALL AND OF SIZE TO WOOL AND SEALED, TO RETAIN THE FIRE INTEGRITY OF THE
DO NOT SUPPORT PIPE WALLS AND FLOORS, WITH A NON-HARDENING COMPOUND
Project Name
COMPLETELY COVER
FROM SLEEVE OPENING SIMILAR OR EQUAL TO DUXSEAL AS MANUFACTURED BY THE J.M.
FINISHED WALL SURFACE CONCEALED PIPING PIPING EXPOSED TO VIEW
CLIPPER CORP.
DETAILS

DETAIL DETAIL
13 N.T.S.
PIPE SLEEVE THRU INTERIOR WALL DETAIL
12 N.T.S.
PIPE PENETRATION THRU RATED WALL DETAIL Sheet Name

Drawing No. P0600


GENERAL DEMOLITION NOTES: PLUMBING KEYNOTES
A. WHERE EXISTING FIXTURES ARE INDICATED TO BE DEMOLISHED:
THIS CONTRACTOR SHALL INCLUDE ALL ASSOCIATED PIPING, 1 PLUMBING CONTRACTOR SHALL DISCONNECT AND REMOVE EXISTING
CARRIERS, SUPPORTS, SLEEVES, HANGERS, FITTINGS, AND OTHER PLANTER/FLOOR DRAIN. CUT AND CAP SANITARY PIPE IN FLOOR. PATCH FLOOR TO
ACCESSORIES. PIPING SHALL BE REMOVED TO A LOCATION ABOVE MATCH EXISTING.
THE CEILING OR BEHIND WALLS AND CAPPED. HOWEVER, NO 2 EXISTING 4" STORM UP TO EXISTING ROOF DRAIN TO REMAIN.
INACTIVE BRANCH OF MORE THAN 2 FEET IN LENGTH CAN REMAIN 3 PLUMBING CONTRACTOR SHALL DISCONNECT AND REMOVE EXISTING WATER
ON ANY PIPE SYSTEM. CONTRACTOR SHALL REMOVE AS REQUIRED. HEATER, ASSOCIATED SUPPORTS, VALVES, AND PIPING AS INDICATED. FIELD
VERIFY AND COORDINATE SELECTIVE DEMOLITION.
B. WHERE DEMOLITION OF A FIXTURE AND REMOVAL OF PIPING OR 4 PLUMBING CONTRACTOR SHALL DEMO PIPING AS INDICATED BACK TO EXISTING
OTHER ACCESSORY LEAVES AN OPENING IN THE FLOOR, WALL, OR MAINS AND CAP. FIELD VERIFY AND COORDINATE SELECTIVE DEMOLITION.
CEILING, SAME SHALL BE PATCHED TO MATCH EXISTING ADJACENT
5 EXISTING INCOMING WATER SERVICE AND DOMESTIC WATER BOOSTER PUMP TO
FINISH.
REMAIN. EXISTING 2" COLD WATER MAIN TO BE REUSED AS INDICATED. FIELD
VERIFY AND COORDINATE SELECTIVE DEMOLITION.
1 2 3 C. EXISTING STORM PIPING TO REMAIN.
6 EXISTING 8" INCOMING DOMESTIC WATER / FIRE PROTECTION SERVICE ENTRY.
7 EXISTING FIRE PROTECTION SERVICE TO EXISTING SYSTEM TO REMAIN.
EX.NFWH EX.NFWH EXISTING VENT THRU
ROOF TO REMAIN.
Department of Capital Planning & Policy
EX.FCO (X)FD
Bureau of Asset Management
A (E)3" V EX. WC (E)3" V Notice: This drawing has not been published and is the
EX.LAV EX.LAV (X)WC
(X)WC 4" EX.FD
sole property of Cook County. It is loaned to the borrower
EX.FCO EX. WC EX.LAV EX.LAV
4" EX.FD
(X)LAV for their confidential use only. In consideration of the loan
4" EX.FD 4 (X)WC
(X)PD EX. WC EX. WC of this drawing, the borrower promises and agrees to
(X) MB
1 EX.EWC-1 return it upon request and agrees that it shall not be
1"
(X)HB-1
EX. WC EX.UR (X)LAV reproduced, copied, loaned, or otherwise disposed of
2" CW (E) 2" CW (E) 2" CW (E)
EX.FCO
directly or indirectly, nor used for any purpose other than
3 for which it is furnished, in whole or part.
(X)FD EX.FCO
2 (E)CO 2 2
(E)CO 4" ST (E) 4" ST (E)
1 (E)CO (E)3"x4" VTR

2"
6" ST TO REMAIN

B 4
4" EX.FD
3/4"
3/4" EX.FCO

(E)6" DOWNSPOUT (E)WCO


4 (X)LAV
1 TO REMAIN
(EXISTING WALL
2
CLEANOUT TO
(X)PD REMAIN; ~12"AFF)

3" ST (E)
2"
4 (E)CO
(E)WCO
C
(E)3"x4" VTR
(E)CO TO REMAIN
(E)CO 4" ST (E) 4" ST (E)
2 2 2 (E)FUNNEL DRAIN
(E)CO 4 TO REMAIN
4" EX.FD

3/4" 3/4"
EX.NFWH
EX.FCO 4" EX.AD
(X)PD 4 4" EX.FD

3/4" CW (E)
1
5 EX.FCO

EX.FCO
7
EX.HB
D
6
EX.NFWH

1 LEVEL 01 PLUMBING DEMOLITION


PD101 1/8" = 1'-0"

Holabird & Root, LLC expressly disclaims any


responsibility arising from any unauthorized use of these
plans, drawings and notes. Any authorization must be in
writing.

This drawing copy may have been reproduced at a size


DEMO HW DISTRIBUTION different than originally drawn. The Owner and Architect
DEMO AND CAP AS INDICATED assume no responsibility for use of incorrect scale.
(E)HUM (E)HUM Drawings are not to be scaled.
DEMO AND CAP DEMO
AND CAP
(E)HW (X)1"CW DEMO AND CAP (E)2"CW
(X)1"HW Not published - All rights reserved.
(E)2"CW (E)2"CW (E)2"CW (X)2"CW (X)2"CW

(X)2"CW
(E)WC-2 (E)WC-1 (E)L-2 (E)L-1 (E)UR-1 (X)S-1 VACUUM (X)L-1 (X)WC-1 (X)EYE WASH
(E)3/4"CW

(E)2"CW

(X)3/4"CW

(E)3/4"CW
(E)2"CW

(E)HW

BREAKER

(X)2"CW
(E)NFWH-1 (E)WC-1 (X)HB-1 (E)EWC-1 (E)L-1 (E)L-1 (E)WC-1 (E)WC-2 (X) (X)WC-1 (X)L-1 (X)WC-2 (X)L-1 DEMO AND CAP (E)METER TO REMAIN
DHW-1
EXISTING FIRE
PROTECTION SERVICE TO
REMAIN

(E)NFWH-1 M
(X)HB-1 (E)NFWH-1

(E)8"CW
DEMO AND CAP DEMO AND CAP
EXISTING INCOMING 8" COMBINED
EXISTING DOMESTIC WATER DOMESTIC WATER/FIRE
DEMO AND CAP BOOSTER PUMP TO REMAIN. PROTECTION SERVICE TO REMAIN

2 09/13/2018 ADDENDUM 1
1 09/07/2018 ISSUE FOR BID
PLUMBING - DOMESTIC WATER RISER DIAGRAM - DEMOLITION
2 04/16/2018 ISSUE FOR DEMO PERMIT
No. Date Issue

Project Number 15849


Drawn FA

Checked FA
(E)3"x4" VTR (E)4"x5" VTR (E)3"x4" VTR Proj. Arch./Eng. FA
EXISTING VENT TO REMAIN EXISTING VENT TO REMAIN

(E)3"
AS SHOWN (TYPICAL) AS SHOWN (TYPICAL)
(E)3" (E)3"
(E)3"

(E)3"

(E)2"

(E)2"

DEMO AND CAP


DEMO AND CAP (E)2"
Provident Hospital - Renal

(E)2"
(X)L-1
(X)L-1

(E)4"
(E)2" (X)2"
(E)UR-1 (E)WC-1 (E)WC-2
(X)S-1
Dialysis Center
(E)EWC-1 (E)L-1 (E)L-1 (E)L-1 (E)L-1 (X)GT-1
(E) (E)WC-2 (E)WC-1 (E)WC-1 (X)CO (X)WC-2 (X)WC-2 (X)WC-1 (X)L-2
FUNNEL
(X)CO DEMO AND CAP
DRAIN
(X)FD-2 (X)PD-1 (E)FD-2 (X)PD-1 DEMO AND CAP (E)L-1
(E)FD-2 (E)AD-1 (X)PD-1 (E)FD-1 (E)FCO
(X)FD-1 (X)MB-1 (E)FD-1
(E)FCO (E)4" (E)4"
(E)GCO
(E)4" (E)4" (E)FCO DEMO AND CAP DEMO AND CAP
DEMO AND CAP (E)4"
(E)4" (E)4"
(E)GCO (E)FCO
DEMO AND CAP (E)FD-1
4" UNDERGROUND SANITARY
SEWER TO REMAIN AS (E)FCO
(E)4" 430 East 51st Place
SHOWN (TYPICAL)
Chicago, Illinois 60615
4" UNDERGROUND SANITARY
SEWER TO REMAIN AS
SHOWN (TYPICAL) Project Name

PLUMBING - SANITARY AND VENT RISER DIAGRAM - DEMOLITION LEVEL 01 - PLUMBING -


3
DEMOLITION PLAN
Sheet Name

Drawing No. PD101

You might also like