sp00-000 843 30 02 02
sp00-000 843 30 02 02
ä
h
tü
u
lo
a
c
d
M
s
n
m
ie
S
ARCADIS
SP
Configuration
System
Valid for:
ARCADIS Varic
ARCADIS Orbic
ARCADIS Avantic
© Siemens 2008
The reproduction, transmission or use
of this document or its contents is not
permitted without express written
authority. Offenders will be liable for
damages. All rights, including rights
created by patent grant or registration
of a utility model or design, are
reserved.
Disclaimer
The installation and service of equipment described herein is to be performed by qualified
personnel who are employed by Siemens or one of its affiliates or who are otherwise
authorized by Siemens or one of its affiliates to provide such services.
Assemblers and other persons who are not employed by or otherwise directly affiliated
with or authorized by Siemens or one of its affiliates are directed to contact one of the
local offices of Siemens or one of its affiliates before attempting installation or service pro-
cedures.
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Reboot, restart and shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Service software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Open the service software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
System Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Local Host. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Site Info . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
TCP/IP LAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Users. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Monitor Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Mail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
FTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Auto Transfers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Event log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Backup/Restore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Licensing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
DICOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Character Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Structured Reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Offline Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Network Nodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Print Devices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
HC Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
LUT Files. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
HIS/RIS Nodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Import/Export . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Directories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
EPRI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
External Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Paper Printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Printer Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
PS LUT Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
SystemMgmt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Master . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Agent Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Pat. Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Viewer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
CorRea . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
MPPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Worklist Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
USB Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
CAN Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Footswitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Trigger Injector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Valid Mainsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Application Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Examination Set Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Edge Enhancement Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
DICOM LUT Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Windowing LUT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Logarithm LUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Metering Sections File. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Display Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Subtraction Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Motion Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Power Off Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Brightness Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Auto Dose Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Auto Lut. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Camera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Circle Mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Hardcopy Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Homogenisation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Person responsible for the network configuration at the customer site. . . . . . . . . . 107
System network data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Network data for HIS/RIS network partner (only with HIS/RIS option) . . . . . . . . . . 108
Network data for reporting console/archiving system . . . . . . . . . . . . . . . . . . . . . . . 108
Network data for reporting console/archiving system . . . . . . . . . . . . . . . . . . . . . . . 109
Abbreviation Definition
BIOS Basic Input Output System, lowest level of PC configura-
tion
AET Application Entity Title - name of the DICOM service that
communicates either as the user (SCU) or the provider
(SCP).
CD Compact disc
CDR Compact Disc Recordable
DVD Digital Video Disc
DICOM Digital Imaging and Communications in Medicine
(ACR-NEMA standard)
DHCP Dynamic Host Configuration Protocol - procedure for
assigning numeric IP addresses to nodes, in which
blocks of addresses are leased to clients on a first-come,
first-served basis. Typically, DHCP is combined with
WINS so an IP address is both dynamically assigned
and automatically associated with a domain name. This
can be combined with DNS, resulting in a dynamically
assigned numeric IP address that is automatically asso-
ciated with both NetBIOS and Internet names.
DNS Domain Name Services - used for address parsing with
numeric IP addresses being linked to names in the Inter-
net format.
FTP File Transfer Protocol - a client-server application that
transfers files from one computer to another.
Gateway Controls data traffic between two networks above the
network layer.
HIS Hospital Information System
LAN Local Area Network (in this case: always Ethernet)
LMHOSTS Address parsing method in which numeric IP addresses
are statically linked to NetBIOS names. The LMHOSTS
file is checked to determine whether the name is
addressed.
NIC Network Interface Card - an expansion card that provides
a physical connection to the network.
PPP Point-to-Point Protocol - data connection and network
protocol for serial connections (such as dial-up
modems).
NOTE Once the <Save> button has been selected in the individual
screens, the message "..... successfully saved” appears fol-
lowing a successful save.
• Select "OK".
12. Click <Apply> and <OK> to close the window “Regional and Language Options”.
¹ If the language has been changed the following message appears:
The following is displayed in the case that values have been changed:
“The regional settings have been changed.
Therefore a restart of the application is necessary.
Do you want to restart the application now?”
¹ In case of language change click <OK>. This will apply the settings and the sys-
tem restarts.
¹ Otherwise shut down the system via <Options>-<End Software Session>-<Shut-
down>.
Configuration 0
NOTE In the case of an initial setup, import the correct license file
for available options first.
System Options 0
Site Info 0
Software installation
This date is set automatically during software installation and cannot be changed.
handed over
• Enter the date and time when the system was handed over to the customer.
System
Material No
• This material no. is entered automatically once the "System typel" has been selected
under “System Options”
- For ARCADIS Varic, “101 43 406” is displayed under “Material No”
- For ARCADIS Orbic, “101 43 407” is displayed under “Material No”
- For ARCADIS Avantic, “101 43 408” is displayed under “Material No”
Rdiag prefix
• This name is entered automatically once the "system model" was entered in the previ-
ous screen. It is needed to generate a unique name for the remote transfer.
- For ARCADIS Varic, "cv" is displayed under "Rdiag Prefix".
- For ARCADIS Orbic, "co" is displayed under "Rdiag Prefix".
- For ARCADIS Avantic, "av" is displayed under "Rdiag Prefix".
Serial No
• Enter the system serial number.
- ARCADIS Varic 12000 to 19999
- ARCADIS Orbic 22000 to 29999
- ARCADIS Avantic 32000 to 39999
NOTE The serial number is mandatory. It may not include any char-
acters other than numbers from 0 to 9.
Department
• Enter the department where the system is located.
Station Name
• Enter the “Station Name” (xxx = last 3 digits of the system serial number).
- For ARCADIS Varic: ARCADISVA12xxx
- For ARCADIS Orbic: ARCADISOR22xxx
- For ARCADIS Avantic: ARCADISAV32xxx
Service
Remote Service Center
• The correct remote service center, Europe, USA or Asia, must be set.
Service Center
• In this field, enter the location of the Service Center responsible for this system. This
information is required for the generation of automatic reports.
Time zone
• Depending on the location of the system
NTP Time Server
• NTP Time Server: Q
¹ If the customer has requested that "NTP Time Server” be selected, you must also
enter the IP address of the NTP server.
DaylightTime
• DaylightTime automatic: H
¹ If the NTP time server was activated, these values are automatically accepted
and no changes can be made.
• Select the values for "Date and time".
• Click "Save".
¹ "You are going to change the time settings .......” appears.
• Click <OK>.
TCP/IP LAN 0
NOTE ARCADIS systems have not been released for use with a
DHCP server.
DHCP server is not selectable.
Specify an IP address
• After you select "Specify an IP address," the following input fields appear:
- IP address
- Subnet mask
- Gateways
IP address
• Under "IP address", enter a valid IP address to identify the system in the network. Con-
tact the network administrator to obtain a valid IP address.
Subnet mask
• The subnet mask indicates the sections into which the address is divided. The data are
distributed via the router based on this division. Contact the network administrator to
obtain the subnet mask ID.
Gateway
• In order the leave the hospital network, it is necessary to inform the system (ARCADIS)
about this gateway (router). Contact the network administrator to obtain the gateway
address.
WINS / Primary WINS server
• Do not enter anything under "Primary WINS server".
Secondary WINS server
• Do not enter anything under "Secondary WINS server".
Enable DNS for Windows resolution
• Enable DNS for Windows resolution: Q
Enable LMHOSTS Lookup
• Enable LMHOSTS Lookup: H
DNS / Domain
• Do not enter anything under "Domain".
DNS service search order
• Do not select or enter anything under "DNS service search order".
Routing 0
Fig. 5: Routing
Hospital / Static Route to SRS
• Set the static route of the hospital.
Server Network Address Translation (NAT)
• The “NAT” functionality is may used in case of system management (see instruction
SRS / system management SPR2-310.843.30...)
Remote service center
• Depending of your settings under “Site Info” ( Europe, USA or Asia) the settings for the
corresponding service center will be automatically set.
Users 0
Fig. 6: Users
Account for UI
• “meduser”
Default Password
• Default Password: H
Enable Autologin
• Enable Autologin: H
Account for PPP / Default Password
• Default Password Q
Account for Administrator
• Disable Account: Q (For the default password see the KB password list, a new list
can be issued at any time)
Monitor Type 0
Monitor Type
• Select "color” and Siemens (Pseudo Color)"
¹ Regardless of whether the monitor is black-and-white or color.
Security 4.3
Settings 0
NOTE If changes have been made and saved here, they may be
activ only by completely reinstalling the system software!
Fig. 8: Settings
Security properties
• User management: Q
• "Data access check: Not selectable
• Functional check: Q
• Auditing: Q
DICOM access
• Enable trusted host functionality: Q
Service 4.4
Mail 0
Fig. 9: Mail
NOTE This menu item allows you to configure the mail target for
the Auto Report function and for the Service Center pro-
vided in the Customer User Interface at Option - Remote Ser-
vice.
For detail information how to configure this functionality
click on “Help” in the navigation bar.
• Click ">".
Mail (page 2)
NOTE This menu item allows you to configure the mail target for
the Auto Report function and for the Service Center pro-
vided in the Customer User Interface at Option - Remote Ser-
vice.
For detail information how to configure this functionality
click on “Help” in the navigation bar.
FTP 0
NOTE This menu item allows you to configure the file transfer tar-
get (FTP) for the Auto Report and for the File&Image Tool
function.
For detail information how to configure this functionality
click on “Help” in the navigation bar.
• Click ">".
FTP (page 2)
NOTE This menu item allows you to configure the file transfer tar-
get (FTP) for the Auto Report and for the File&Image Tool
function.
For detail information how to configure this functionality
click on “Help” in the navigation bar.
Auto Transfers 0
NOTE If the customer agrees, automatic transfer (i. e., without user
interaction) of Auto-reporting messages or System Manage-
ment Event messages may be enabled here.
As long “Mail” or “FTP” is not configured / enabled this set-
ting has no effect.
Event log 0
Backup/Restore 0
Licensing 0
Licensing Details
General Settings
DICOM 4.5
DICOM allows you to specify the parameters for the DICOM communication interfaces of
your system and the remote systems.
AET = Application Entity Title
General 0
Character Set 0
Structured Reports 0
Offline Devices 0
Offline devices allow you to make settings for DICOM offline devices (media storage) on
the local host.
Network Nodes 0
Edit Name
• Enter the name under "edit name".
Host
• Under "Host", select the name entered on the previous page.
AE title
• Select "define new".
¹ The AETs that have already been configured are shown in the pull-down menu.
Edit AE Title
• Enter a name in the "edit AE Title" field.
Port number
• Enter the port number for the DICOM device.
• Click "Add".
• Do not select "Verification".
Storage
• Storage H
• Retrieve: H (if the particular DICOM device is to support query)
• Do not make any changes under "Storage".
• Click <Save>.
Storage Commitment
• Select "Storage Commitment" if the particular DICOM device is to be configured as the
Storage Commitment provider.
Query
• Query: H (if the particular DICOM unit is to support query)
• Patient root: H (under "Provides DICOM query model")
Retrieve
• Retrieve: H (if the particular DICOM device is to support retrieve)
• Click <Save>.
Print Devices 0
Here you define the DICOM laser cameras that are connected to your system via DICOM
Basic Print. A local printer is NOT a DICOM printer!
This system does not support the SPCI/SPDI camera interface
NOTE You will find the installation instructions for each released
camera on CB-DOC under Installation, in the "Camera” cata-
log.
Print Devices 1
• Verify that the required DICOM basic license is available.
- This can be checked as follows:
In the service software, go to --> Configuration --> Service --> Licensing.
ASPIA_DICOM_BASIC....”should be listed under Licenses.
Host Properties
• Under "Select Host", select "define new".
Host name
• Enter host name of the DICOM camera.
TCP/IP address
• Enter the IP address.
Connected by
• LAN: H
• Under "Select Host", select the host name entered for the DICOM camera.
• Click <Save>.
• Click ">".
Print Devices 2
Logical Name
• Select "define new".
Edit Name
• Enter the name under "edit Name".
Host
• Under "Host", select the name entered on the previous page.
AE Title
• Select "Define new".
¹ The AETs that have already been configured are shown in the pull-down menu.
Edit AE Title
• Enter a name in the "edit AE title" field.
Port number
• Enter the port number for the DICOM device.
• Do not select "Verification".
• Click "Add".
Print
• Print: H
• Click <Save>.
• Click ">".
Print Devices 3
Select HC device
• Select "define new" under "Select HC device".
HC Device
• Enter the name of the camera.
¹ This name will be displayed in the customer interface in the "Print" tab card.
Default Camera
General settings
Type
• Select "DICOM printer".
Class
• Select the DICOM camera in the pull-down menu, and make no other changes on this
page.
If your camera is not yet released or not in the list, contact the responsible Headquar-
ters Support Center.
• Click <Save>.
HC Overview 0
NOTE This menu has no meaning for the service engineer since
the settings and tests can also be performed in the "Print
device" menu.
The "Hard Copy Overview" menu is intended to provide the customer with a menu to
manipulate and test certain camera settings.
LUT Files 0
LUT files (lookup table) for DICOM Basic Print can be imported, deleted, or selected in
this menu.
NOTE The LUTs are automatically installed along with the software.
• Click ">".
LUT Files 2
NOTE Do not make any changes since all values will be entered
automatically during the software installation.
• Presentation LUT: Q
• Correction LUT: H
• Show only configurable image types: H
• Overall maximum density: “3.00”
• Interpolation for printing: "Cubic”
• Mode: 0
HIS/RIS Nodes 0
HIS/RIS Nodes
Host Properties
• Under "Select Host", select "Define new".
Host name
• Enter the HIS / RIS node host name.
TCP/IP address
• Enter the IP address.
Connected by
• LAN: H
• Click <Save>.
• Under "Select Host", select the host name entered for HIS/RIS.
• Click ">".
HIS/RIS Nodes 2
Host
• Under "Host", select the name entered on the previous page.
Logical Name
• Select "define new".
Edit Name
• Enter the name under "edit Name".
AE Title
• Select "define new".
¹ The AETs that have already been configured are shown in the pull-down menu.
Edit AE Title
• Enter a name in the "Edit AE title" field.
Port number
• Enter the port number for the DICOM device.
• Do not select Verification.
• Click "Add".
At the beginning and following patient acquisition, the DICOM Service Modality Performed
Procedure Step (MPPS) sends data to the information system (e.g., RIS). Select this
option if the selected information system is to be used as the destination for this DICOM
service.
Default Catalog Name
• If codes are used, enter the name of the coding catalog used in the information system.
Default PPS node
• Select "Default PPS node".
• Click <Save>.
Import/Export 4.6
Directories 0
The system provides the function to import or export DICOM images from/to the file sys-
tem. In this section, specify the location of the import/export directories. They will be
located on the local system or in a shared directory.
For shared directories, you first need to configure the host on which the shared directory
is located.
To import/export DICOM images you need to select "Transfer - import from offline" or
"Import/export to offline" on the customer user interface.
Select Host
• Click “Select Host” drop down menu to see whether the host is already listed. If so, and
if the listed host is correct, your are done and may continue with the next menu.
¹ The “Host” must be already configured under “Site Info/Station Name” and also
under “TCP/IP LAN/Computer Name”.
• Click “>” to go to the next page.
DVD Drive
USB Device
EPRI 4.7
The EPRI (Electronic Patient Record Interface) is a web interface (Internet Explorer
browser) to a server, which provides additional data about the selected patient.
Server 0
The customer user interface provides a button to open a web browser with a link to an
EPR server. The URL and the type of EPR server need to be specified in this menu.
EPR Interface
Location of EPRServer
• Do not make changes under "Location of EPRServer".
Type of EPRServer
• Do not make changes under "Type of EPRServer".
Paper Printer 0
Printer Settings 0
PS LUT Files 0
SystemMgmt 4.9
The IP address of the system management to which the event management agent is to
send its messages must be configured under this item.
Master 0
Agent Controls 0
The configured “Remote Service Center” (Europe, USA or Asia) under “Site Info” is shown
at this page and tested at this page.
Installation State
The status is automatically displayed if system management was configured.
Applications 4.10
Menus for setting the application parameters are available under "Applications".
Pat. Registration 0
Viewer 0
CorRea 0
In this menu, you can set the attributes that can be modified in the CorRea(=Correct &
Rearrange Platform).
MPPS 0
The attributes defined here are displayed on the customer user interface when an MPPS
message is sent to the RIS.
Worklist Results 0
The attributes defined here are displayed in the patient registration form after a DICOM
Worklist request.
CAN Bus
• Bautrate: 125 kBit/s (Default)= Must be selected for Orbic 3D
• Bautrate: 500 kBit/s = Select if connecting a lithotripter (e.g., Variostar) with a baud rate
of 500 kBit/s.
Footswitch 5.2
Here it can be selected if the fluoro pedal of the foot switch releases continious (CFC) or
pulsed fluoroscopy (PFC).
Footswitch Configuration
• Operating Mode of the fixed swtich: CFC
If the system is eqipped with a trigger output for a contrast injector, here this output can
be enabled and the pulse lenght can be adjusted.
• Trigger: Q
• Trigger durat on: 10 (x10ms)
NOTE The Examination Set Editor may not be opened during con-
figuration of the imaging system.
Valid Mainsystem
• Serial Number:
¹ Varic = 12xxx
¹ Orbic = 22xxx
¹ Avantic = 32xxx
NOTE For application fields that require a license, you must first
load the license. Then you will be able to activate this appli-
cation field as described below.
Application Fields
• To activate an application field, it must be selected under "Application Fields" and then
activated by pressing the "Activate" button.
¹ There are application fields that require a license, e.g., Vascular (DSA).
• Under “Activated Application Fields” select the corresponding application field and click
“Set Default.
¹ The "Default Application Field" is “Ortho/Trauma”.
The minimum and maximum filters and LUT‘s for each examination set can be defined
here per the customer’s request.
• “Dose Area Product” or “Air Kerma” can be selected (as required by the customer).
- Display Type = “Dose Area Product” (default)
The minimum and maximum values for noise suppression for the individual phases are
set here.
Duration
• Phase A: 75 (frames)
Peak OP
• Frame rate: 5 (fps)
MD1 Parameter
• K1: GGM (k = 8)
• K1 motion: GGM (k = 2)
• K2: GGM (k= 8)
• Threshold: 125
• Low Pass Kernel: 11
MD2 Parameter
• K1: GGM (k = 8)
• K1 motion: GGM (k = 2)
• K2: GGM (k= 8)
• Threshold: 160
• Low Pass Kernel: 11
MD3 Parameter
• K1: GGM (k = 8)
• K1 motion: GGM (k = 2)
• K2: GGM (k= 8)
• Threshold: 200
• Low Pass Kernel: 11
MD4 Parameter
• K1: GGM (k = 8)
• K1 motion: GGM (k = 2)
• K2: GGM (k= 8)
• Threshold: 250
MD5 Parameter
• K1: GGM (k = 8)
• K1 motion: GGM (k = 2)
• K2: GGM (k= 8)
• Threshold: 300
• Low Pass Kernel: 11
Brightness Control
• AGA unit disabled: Q
- "AGA unit disabled" should be selected only for service purposes.
¹ "AGA unit disabled" is reset by closing the service software.
Brightness Control
• Nominal Brightness Value: 700
• Nominal Brightness Value Limitation Min: 650
• Nominal Brightness Value Limitation Max: 750
• Nominal Brightness Value (Median, Autogamma) 2100
Brightness Control (Metal Button)
• Nominal Brightness Value: 500
• Nominal Brightness Value Limitation Min: 460
• Nominal Brightness Value Limitation Max: 540
• Nominal Brightness Value (Median, Autogamma) 1900
Auto Dose 1 of 6
• Auto dose: H
• Increase: “Absolute”
• Increase Min: 2
• Percent Decrease Max: 50
• Brightness Value: “Mean”
• Minimum Grey Level: 400
• Minimum Pixel Count: 10000
Histogram based brightness value
• Histogram based brightness value: H
• Increase: “Percent”
• Increase Min: 10
• Percent Decrease Max: 40
• Brightness Value: “Mean”
• Minimum Grey Level: 400
• Minimum Pixel Count: 10000
Auto Dose 2 of 6
• Auto dose: H
• Increase: “Absolute”
• Increase Min: 2
• Percent Decrease Max: 0
• Brightness Value: “Mean”
• Minimum Grey Level: 400
• Minimum Pixel Count: 10000
Histogram based brightness value
• Histogram based brightness value: H
• Increase: “Percent”
• Increase Min: 10
• Percent Decrease Max: 0
• Brightness Value: “Mean”
Camera 6.16
Camera Gain
• DR single: Avantic = 1 / Varic, Orbic = 2
• DR single sum: 2
• CFC: 2
• PFC IDL: 2
• PFC PDL: 2
• DCM: 1
• 3D: 1
• SUB/ROAD: 2
Circle Mask
• Radius: 508 (pixel)
• Circle Mask Display: “on”
¹ A switch to "transparent" can be made for service purposes.
Hardcopy Configuration
• Hardcopy button sends image to Filming Taskcard: H
Homogenisation 6.19
Homogenisation
• Homogenisation mode: “Brightness and Images”
NOTE In the main system service pages, you must press the
"Enter” key after entering a parameter.
When this is done, the "Save” button is displayed.
NOTE Once the "Save" button has been selected in the individual
screens, the message "..... successfully saved” appears fol-
lowing a successful save.
--> Click "OK”.
Main System 0
• System Type: Check to make sure that the correct system type is displayed here.
- Depending on the system, "ARCADIS Varic”, "ARCADIS Orbic” or ARCADIS Orbic
3D” can be displayed here.
• Serial No.: Enter the system serial number
- Varic: 12xxx (xxx = last 3 digits of serial number)
- Orbic: 22xxx (xxx = last 3 digits of serial number)
• Disable X-Ray: "no” (default)
• Log old messages: "yes” (default)
• Foot switch fix Mode: "Right”
- defines the foot switch pedal for fluoro mode.
¹ change only on customer demand to “Left”
Load Counter 0
• New SERIAL No Single Tank: Enter the serial number of the "Single Tank”.
¹ The serial number can be found on the single tank housing.
Options 0
Laser
• Laser Existing: If a laser light is installed select "yes”.
Current Limitation 0
Buzzer 0
Buzzer settings
• Buzzer Mode (direct, cassette): “After Exposure”
• Buzzer Mode (indirect): “Buzzer Off”
Blocktime settings
• Warning Time Limit: 50 (min/10)
• Blocking Time Limit:
- For DHHS counties: 0 (min/10)
- For non DHHS countries: 50 (min/10)
NOTE With setting the “Blocking Time Limit” to “0”, the x-ray block-
ing is disabled.
Image Intensifier 0
NOTE In the main system service pages, you must press the
"Enter” key after entering a parameter.
When this is done, the "Save” button is displayed.
NOTE Once the "Save" button has been selected in the individual
screens, the message "..... successfully saved” appears fol-
lowing a successful save.
--> Click "OK”.
Main System 0
Image Intensifier 0
Load Counter 0
• New SERIAL No Single Tank: Enter the serial number of the "Single Tank”.
¹ The serial number can be found on the single tank housing.
Options 0
Laser
• Laser existing: If a laser light is installed select "Yes”.
Diaphragm
• Power on Pos: “+90 DEGREE”
Current Limitation 0
Buzzer 0
Buzzer Settings
• Buzzer mode during x-ray: “BUZZER OFF”
Blocktime Settings
• Warning Time Limit: 50 (min/10)
• Blocking Time Limit:
- For DHHS counties: 0 (min/10)
- For non DHHS countries: 50 (min/10)
NOTE With setting the “Blocking Time Limit” to “0”, the x-ray block-
ing is disabled.
NOTE The monitor trolley and the basic unit must be connected.
(Plug X10 is connected to socket X10.)
Name:
Phone/fax:
E-mail:
Comment:
Network data for HIS/RIS network partner (only with HIS/RIS option) 0
Configured: Yes No
Product: Version: Manufacturer:
Host properties:
* Configuration/DICOM/Net-
Host name
work nodes
* Configuration/DICOM/Net-
TCP/IP address
work nodes
General node properties
* Configuration/DICOM/Net-
Logical name
work nodes
Application entity
* Configuration/DICOM/Net-
AE title
work nodes
* Configuration/DICOM/Net-
Port number
work nodes
Comment:
Configured: Yes No
Product: Version: Manufacturer:
Host properties:
* Configuration/DICOM/Net-
Host name
work nodes
* Configuration/DICOM/Net-
TCP/IP address
work nodes
General node properties:
* Configuration/DICOM/Net-
Logical name
work nodes
Application entity:
* Configuration/DICOM/Net-
AE title
work nodes
* Configuration/DICOM/Net-
Port number
work nodes
Supported DICOM ser-
vices:
Yes No * Configuration/DICOM/Net-
Storage
work nodes
Yes No * Configuration/DICOM/Net-
Storage Commitment
work nodes
Node name: * Configuration/DICOM/Net-
work nodes
Yes No * Configuration/DICOM/Net-
Query
work nodes
Yes No * Configuration/DICOM/Net-
Retrieve
work nodes
Comment:
Configured: Yes No
Product: Version: Manufacturer:
Host properties:
* Configuration/DICOM/Net-
Host name
work nodes
* Configuration/DICOM/Net-
TCP/IP address
work nodes
General node properties:
* Configuration/DICOM/Net-
Logical name
work nodes
Application entity:
* Configuration/DICOM/Net-
AE title
work nodes
* Configuration/DICOM/Net-
Port number
work nodes
Supported Dicom ser-
vices:
Yes No * Configuration/DICOM/Net-
Storage
work nodes
Yes No * Configuration/DICOM/Net-
Storage Commitment
work nodes
Node name: * Configuration/DICOM/Net-
work nodes
Yes No * Configuration/DICOM/Net-
Query
work nodes
Yes No * Configuration/DICOM/Net-
Retrieve
work nodes
Comment:
Chapter 4 Changes
Import/Export - Directories with USB device configuration completed