XCKM115: Product Data Sheet

This document provides product information for the XCKM115 limit switch. It has a thermoplastic roller lever, 1 normally closed and 1 normally open snap action contact, and is IP66 rated. Key specifications include a 30 degree cam actuation, screw clamp terminals that can accommodate wires up to 1.5mm2, and electrical durability of 5 million cycles.

Uploaded by

Vasile Dumitru
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
60 views6 pages

XCKM115: Product Data Sheet

This document provides product information for the XCKM115 limit switch. It has a thermoplastic roller lever, 1 normally closed and 1 normally open snap action contact, and is IP66 rated. Key specifications include a 30 degree cam actuation, screw clamp terminals that can accommodate wires up to 1.5mm2, and electrical durability of 5 million cycles.

Uploaded by

Vasile Dumitru
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Product data sheet XCKM115

Characteristics limit switch XCKM - thermoplastic roller lever -


1NC+1NO - snap action - Pg11

Main
Range of product OsiSense XC
Series name Standard format
Product or component Limit switch
type
Device short name XCKM
Body type Fixed
Head type Rotary head
Material Metal
Body material Zamak

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Fixing mode By the body
Movement of operating Rotary
head
Type of operator Spring return roller lever thermoplastic
Type of approach Lateral approach 2 directions
Cable entry 3 entries tapped for Pg 11 cable gland
Number of poles 2

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Contacts type and com- 1 NC + 1 NO
position

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Contacts operation Snap action

Complementary
Switch actuation By 30° cam
Electrical connection Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Contacts insulation form Zb
Number of steps 1
Positive opening With
Positive opening minimum torque 0.25 N.m
Minimum torque for tripping 0.1 N.m
Minimum actuation speed 0.01 m/min
Maximum actuation speed 1.5 m/s
Contact code designation Q300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to EN/IEC 60947-5-1 ap-
pendix A
A300, AC-15 (Ue = 240 V, Ie = 3 A) conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current 10 A AC
[Ui] rated insulation voltage 300 V conforming to CSA C22.2 No 14
500 V degree of pollution 3 conforming to IEC 60947-1
300 V conforming to UL 508
Resistance across terminals <= 25 MOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-1
6 kV conforming to IEC 60664
Short circuit protection 10 A by gG cartridge fuse
Electrical durability 5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate: <= 60
cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate: <= 60 cyc/
mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate: <= 60
cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Mechanical durability 15000000 cycles
Width 64 mm

Oct 5, 2015
1
Height 64 mm
Depth 30 mm
Product weight 0.28 kg
Terminals description ISO n°1 (13-14)NO
(21-22)NC

Environment
Shock resistance 50 gn (duration = 11 ms) conforming to EN/IEC 60068-2-27
Vibration resistance 25 gn (f = 10...500 Hz) conforming to EN/IEC 60068-2-6
IP degree of protection IP66 conforming to EN/IEC 60529
IK degree of protection IK05 conforming to EN 50102
Class of protection against electric shock Class I conforming to NF C 20-030
Class I conforming to IEC 61140
Ambient air temperature for operation -25...70 °C
Ambient air temperature for storage -40...70 °C
Protective treatment TC
Product certifications CCC
CSA
UL
Standards EN 60204-1
EN 60947-5-1
IEC 60204-1
IEC 60947-5-1
UL 508
CSA C22.2 No 14

Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code: YYWW)
Compliant - since 1007 - Schneider Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Product environmental profile Available Download Product Environmental
Product end of life instructions Need no specific recycling operations

2
Product data sheet XCKM115
Dimensions Drawings

Dimensions

(1) 3 tapped entries Pg 11 cable gland


Ø: 2 elongated holes Ø 5.2 x 6.2

3
Product data sheet XCKM115
Mounting and Clearance

Mounting with Cable Entry

Position of Cable Gland

(1) Recommended
(2) To be avoided

Mounting with Rotary Heads and Levers

Type of Cam

(1) Recommended
(2) To be avoided

4
Product data sheet XCKM115
Connections and Schema

Wiring Diagram

2-pole NC + NO Snap Action

5
Product data sheet XCKM115
Technical Description

Characteristics of Actuation

Switch Actuation by 30° Cam

Functionnal Diagram

(P) Positive opening point


(1) NC contact with positive opening operation
(2) Closed
(3) Open
(4) Tripping