Product data sheet XCKJ110511H29

Characteristics Limit switch, XC Standard, XCKJ, thermoplastic


roller lever, 1C/O, snap action, M20

Main
Range of product Telemecanique Limit switches XC Standard
Series name Standard format
Product or component Limit switch
type
Device short name XCKJ
Sensor design Form A conforming to CENELEC EN 50041
Body type Plug-in body
Head type Rotary head
Material Metal
Body material Zamak

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Head material Zamak
Fixing mode By the body
Movement of operating Rotary
head
Type of operator Spring return roller lever thermoplastic
Type of approach Lateral approach, 1 or 2 programmable direction
Cable entry 1 entry tapped for M20 x 1.5 cable gland, cable out-

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
er diameter: 7…13 mm

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Number of poles 1
Contacts type and com- 1 C/O
position
Contact operation Snap action

Complementary
Switch actuation By 30° cam
Electrical connection Screw-clamp terminals, clamping capacity: 1 x 0.75...2 x 1.5 mm²
Contacts insulation form Za
Number of steps 1
Positive opening Without
Minimum torque for tripping 0.25 N.m
Maximum actuation speed 1.5 m/s
[Ie] rated operational current 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current 10 A
[Ui] rated insulation voltage 300 V conforming to UL 508
500 V (pollution degree 3) conforming to IEC 60947-1
300 V conforming to CSA C22.2 No 14
Maximum resistance across terminals 25 MOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage 6 KV conforming to IEC 60664
6 kV conforming to IEC 60947-1
Short-circuit protection 10 A cartridge fuse, type gG
Electrical durability 5000000 Cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/
mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 Cycles, DC-13, inductive load type, 24 V, 10 W, operating rate <60 cyc/
mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <60 cyc/
mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Mechanical durability 30000000 cycles
Width 43 mm

Jul 18, 2024


1
Height 84 mm
Depth 36 mm
Net weight 0.48 kg
Terminals description ISO n°1 (13-14)NO
(11-12)NC

Environment
Shock resistance 50 gn for 11 ms conforming to IEC 60068-2-27
Vibration resistance 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
IP degree of protection IP66 conforming to IEC 60529
IK degree of protection IK07 conforming to EN 50102
Overvoltage category Class I conforming to IEC 61140
Class I conforming to NF C 20-030
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -40…70 °C
Protective treatment TH
Product certifications CCC[RETURN]UL[RETURN]CSA
Standards IEC 60947-5-1
CENELEC EN 50041
CSA C22.2 No 14
EN 60204-1
UL 508
IEC 60204-1
EN 60947-5-1

Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 4.400 cm
Package 1 Width 6.900 cm
Package 1 Length 13.000 cm
Package 1 Weight 512.000 g
Unit Type of Package 2 S01
Number of Units in Package 2 10
Package 2 Height 15 cm
Package 2 Width 15 cm
Package 2 Length 40 cm
Package 2 Weight 5.342 kg

Offer Sustainability
Sustainable offer status Green Premium product
Circularity Profile No need of specific recycling operations
California proposition 65 WARNING: This product can expose you to chemicals including: Diisononyl
phthalate (DINP), which is known to the State of California to cause cancer,
and Di-isodecyl phthalate (DIDP), which is known to the State of California
to cause birth defects or other reproductive harm. For more information go to
www.P65Warnings.ca.gov
???ecat.characteristic.sensors.contact.at.tx??? sustainability@tesensors.com

Contractual warranty
Warranty 18 months

2
Product data sheet XCKJ110511H29
Dimensions Drawings

Dimensions

(1) 1 tapped entry M20 x 1.5

3
Product data sheet XCKJ110511H29
Mounting and Clearance

Mounting with Cable Entry

Position of Cable Gland

(1) Recommended
(2) To be avoided

Mounting with Rotary Heads and Levers

Type of Cam

(1) Recommended
(2) To be avoided

Setting-up with Lever Head

(1) 5° steps throughout 360° / Tightening torque (Min : 1) (Max : 1.5)


(2) 45° steps throughout 360° / Tightening torque (Min : 1) (Max : 1.5)
(a) Tightening torque (Min : 1) (Max : 1.5)

Setting-up with Head ZCKE05

4
Direction of Actuation Programming

5
Product data sheet XCKJ110511H29
Connections and Schema

Wiring Diagram

Single-pole CO Snap Action

6
Product data sheet XCKJ110511H29
Technical Description

Characteristics of Actuation

Switch Actuation on End

Functionnal Diagram

(1) Closed
(2) Open
(3) Tripping
(4) Resetting