100% found this document useful (1 vote)
2K views8 pages

Saes H 004

This document provides specifications for three protective coating systems (APCS-19A, APCS-19B, and APCS-19C) for offshore structures. It specifies the type of coating, general data including typical uses and limitations, surface preparation requirements, and dry film thickness requirements for each coating system. The document also notes that mandatory technical properties and application instructions are provided in another Saudi Aramco specification.

Uploaded by

kaleeswaran s
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
2K views8 pages

Saes H 004

This document provides specifications for three protective coating systems (APCS-19A, APCS-19B, and APCS-19C) for offshore structures. It specifies the type of coating, general data including typical uses and limitations, surface preparation requirements, and dry film thickness requirements for each coating system. The document also notes that mandatory technical properties and application instructions are provided in another Saudi Aramco specification.

Uploaded by

kaleeswaran s
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Document Responsibility: Paints and Coatings Standards Committee SAES-H-004

Issue Date: 15 December 2015 Protective Coating Selection and Application


Next Planned Update: 15 December 2018 Requirements for Offshore Structures and Facilities

APCS - 19A

1 Type of Coating

Splash Zone Compound, Hand Applied Grade

2 General Data

2.1 Typical Use

Temporary maintenance coating on boat landings and non-critical steel


surfaces in splash zone or immersion service. Patch repairs to
APCS - 19A and APCS - 19B.

2.2 Service Condition Limitations

2.2.1 Maximum Service Temperature: 80°C

2.2.2 Not suitable for use in contact with potable water.

2.3 Purchase Specification: 09-SAMSS-070

2.4 SAP Material Number (SAMS Stock Number): 1000194524 (09-612-345)

3 Surface Preparation Requirements

3.1 Minimum Cleanliness Level

3.1.1 Initial: Sa 2-1/2 (SSPC-SP10)

3.1.2 Touch-up: Sa 2-1/2 (SSPC-SP10)


St 3 (SSPC-SP3) for areas less than 0.1 m²

3.2 Profile: 65-100 micrometers, minimum-maximum

Abrasive: 1000161063 (08-220-850), 1000161200


(08-220-890) or 1000160377 (08-202-910).

4 Dry Film Thickness Requirements

Total System: One coat


2500 micrometers, minimum
Commentary Note:

Mandatory technical properties and storage, mixing, and application requirements


shall be as given in the Saudi Aramco Data Sheets (SAES-H-101V).

Page 55 of 80
Document Responsibility: Paints and Coatings Standards Committee SAES-H-004
Issue Date: 15 December 2015 Protective Coating Selection and Application
Next Planned Update: 15 December 2018 Requirements for Offshore Structures and Facilities

APCS - 19B

1 Type of Coating

Splash Zone Compound, Spray Applied Grade

2 General Data

2.1 Typical Use

Certain steel surfaces in splash zone areas of marine structures such as


offshore platforms, jetties, and steel pilings. Also, as a pipe coating at
above/below ground transitions and road crossings.

2.2 Service Condition Limitations

2.2.1 Maximum Service Temperature: 80°C

2.2.2 Not suitable for use in contact with potable water.

2.3 Purchase Specification: 09-SAMSS-070

2.4 SAP Material Number (SAMS Stock Number): 1000194520 (09-612-339)

3 Surface Preparation Requirements

3.1 Minimum Cleanliness Level

3.1.1 Initial: Sa 2-1/2 (SSPC-SP10)

3.1.2 Touch-up: Sa 2-1/2 (SSPC-SP10)


St 3 (SSPC-SP3) for areas less than 0.1 m²

3.2 Profile: 65-100 micrometers, minimum-maximum

Abrasive: 1000161063 (08-220-850), 1000161200


(08-220-890) or 1000160377 (08-202-910)

4 Dry Film Thickness Requirements

Total System: One coat


2500 micrometers, minimum
Commentary Note:

Mandatory technical properties and storage, mixing, and application requirements


shall be as given in the Saudi Aramco Data Sheets (SAES-H-101V).

Page 56 of 80
Document Responsibility: Paints and Coatings Standards Committee SAES-H-004
Issue Date: 15 December 2015 Protective Coating Selection and Application
Next Planned Update: 15 December 2018 Requirements for Offshore Structures and Facilities

APCS - 19C

1 Type of Coating

Glass Flake Reinforced Epoxy Coating Systems for Offshore Structural Steel at
Splash Zone.

2 General Data

2.1 Typical Use: Corrosion protection for offshore and marine structural
steel members at splash zone and atmospheric exposure.

2.2 Service Conditions and Limitations

2.2.1 Maximum Service Temperature: 93°C

2.2.2 Not suitable for Hot Risers in Splash Zone.

2.2.3 Suitable for new construction and rehabilitation of existing


Structural Steel members

2.3 Purchase Specification: 09-SAMSS-070

2.4 SAMS Stock Number

1000788243/1000788244 (Epoxy)

3 Surface Preparation Requirements

3.1 Minimum Cleanliness Level

3.1.1 Initial (New Construction): SSPC-SP5 (Sa 3)

3.1.2 Touch-up and Recoat: SSPC-SP6 (Sa 2)


St 3 (SSPC-SP3) for areas less than
0.1 m²

3.2 Profile: 60-100 microns, average 75 micrometers (3 mils)

Abrasive: M/N 1000161068, 1000161203 and 1000160374


(S/N 08-220-865, 08-220-895, or 08-202-900)

Page 57 of 80
Document Responsibility: Paints and Coatings Standards Committee SAES-H-004
Issue Date: 15 December 2015 Protective Coating Selection and Application
Next Planned Update: 15 December 2018 Requirements for Offshore Structures and Facilities

4 Dry Film Thickness Requirements

Total System:

4.1 New Construction: Two coats @ 600-750 microns per coat and total of
1200-1500 microns

4.2 Maintenance Coating for Existing Structures:


One Coat @ 750 – 1000 microns
Commentary Note:

Mandatory technical properties and storage, mixing, and application requirements


shall be as given in the Saudi Aramco Data Sheets (SAES-H-101V).

Page 58 of 80
Document Responsibility: Paints and Coatings Standards Committee SAES-H-004
Issue Date: 15 December 2015 Protective Coating Selection and Application
Next Planned Update: 15 December 2018 Requirements for Offshore Structures and Facilities

APCS - 22A

1 Type of Coating

Epoxy Coating for Application onto Damp Steel Surfaces; Two-Coat System

2 General Data

2.1 Typical Use

Offshore Steel Structures in above-water areas. Can be applied in


conditions of high humidity to a slightly damp substrate.

2.2 Service Condition Limitations

2.2.1 Maximum Service Temperature: 120°C

2.2.2 Not normally suitable for immersion service.

2.3 Purchase Specifications: 09-SAMSS-087

2.4 SAP Material Numbers (SAMS Stock Numbers)

2.4.1 Primer: 1000194560 (09-612-352) or 1000195239


(09-612-459) depending on can size

2.4.2 Topcoat: 1000194565 (09-612-357), 1000194568


(09-612-358), 1000194590 (09-612-359),
1000195273 (09-612-462), 1000195277
(09-612-465) or 1000195314 (09-612-467)
depending on color and can size

2.4.3 Thinner: 1000198471 (09-738-300)

3 Surface Preparation Requirements

3.1 Minimum Cleanliness Level

3.1.1 Initial: Sa 2-1/2 (SSPC-SP10)

3.1.2 Touch-up: Sa 2-1/2 (SSPC-SP10)


St 3 (SSPC-SP3) for areas less than 0.1 m²

Page 59 of 80
Document Responsibility: Paints and Coatings Standards Committee SAES-H-004
Issue Date: 15 December 2015 Protective Coating Selection and Application
Next Planned Update: 15 December 2018 Requirements for Offshore Structures and Facilities

3.2 Profile: 40-65 micrometers, minimum-maximum

Abrasive: 1000161068 (08-220-865), 1000161203


(08-220-895) or 1000160374 (08-202-900)

4 Dry Film Thickness Requirements

4.1 Each Coat: Two coat


150-200 micrometers, maximum per coat

4.2 Total System: Two coats


300-400 micrometers, minimum-maximum
Commentary Note:

Mandatory technical properties and storage, mixing, and application


requirements shall be as given in the Saudi Aramco Data Sheets
(SAES-H-101V).

Page 60 of 80
Document Responsibility: Paints and Coatings Standards Committee SAES-H-004
Issue Date: 15 December 2015 Protective Coating Selection and Application
Next Planned Update: 15 December 2018 Requirements for Offshore Structures and Facilities

APCS - 22B

1 Type of Coating

Epoxy Coating for Application onto Damp Steel Surfaces; One-Coat System

2 General Data

2.1 Typical Use

Offshore Steel Structures in above-water areas. Can be applied in


conditions of high humidity to a slightly damp substrate.

2.2 Service Condition Limitations

2.2.1 Maximum Service Temperature: 120°C

2.2.2 Not normally suitable for immersion service.

2.3 Purchase Specifications: 09-SAMSS-087 (modified)

2.4 SAP Material Numbers (SAMS Stock Numbers)

2.4.1 Coating: 1000647350 (09-000-461), 1000647351


(09-000-462), 1000647352 (09-000-463),
1000647353 (09-000-464), 1000669337
(09-000-489), 1000669338 (09-000-490),
1000669339 (09-000-491) or 1000669590
(09-000-492) depending on color

2.4.2 Thinner: 1000647354 (09-000-465)

3 Surface Preparation Requirements

3.1 Minimum Cleanliness Level

3.1.1 Initial: Sa 2-1/2 (SSPC-SP10)

3.1.2 Touch-up: Sa 2-1/2 (SSPC-SP10)


St 3 (SSPC-SP3) for areas less than 0.1 m²

3.2 Profile: 40-65 micrometers, minimum-maximum

Abrasive: 1000161068 (08-220-865), 1000161203


(08-220-895) or 1000160374 (08-202-900)

Page 61 of 80
Document Responsibility: Paints and Coatings Standards Committee SAES-H-004
Issue Date: 15 December 2015 Protective Coating Selection and Application
Next Planned Update: 15 December 2018 Requirements for Offshore Structures and Facilities

4 Dry Film Thickness Requirements

4.1 Total System One coat

350-500 micrometers for atmospheric service


Commentary Note:

Mandatory technical properties and storage, mixing, and application


requirements shall be as given in the Saudi Aramco Data Sheets
(SAES-H-101V).