Brochure DPA
Brochure DPA
10
Single phase UPS software
36
Three phase UPS teleservice
GIOTTO
450-2000 VA
Line-interactive
2
Single phase UPS
for personal computers
servers
TLC equipment
Ideal for
SOHO and SME
LEONARDO
6 -10 kVA
On-line
Tower and Rack/Tower
GALILEO
1000-3000 VA
On-line
Tower and Rack/Tower
3
GIOTTO
450-2000 VA
Line-interactive 1-phase
For PCs and peripherals
Ideal for home and Features and benefits
small office ● User-friendly UPS ensuring compact
protection for a wide range of needs:
• Best power protection for PC from
450 to 850 VA with one output
receptacle (IEC 320-C13) and one
Schuko
• Advanced power protection from
1000 to 2000 VA with four output
receptacles (IEC 320-C13) and one
Schuko for high performance PC and
peripherals
● Instantaneous battery back-up power
and electrical interference protection
● Plug and Play installation easy to set up
also for first user
● Compact and noise-free running to be
placed anywhere at home or office
● Energy efficient ensuring lowest impact
on energy costs.
● Intuitive LCD display provides
easy-to-read UPS status and power
information
● Audible alarm alerts upon utility power
and UPS status change
● Easy User-replaceable battery
● AVR technology stabilizing output
voltage to protect your electronics over a
wide range of mains quality issues
● Advanced battery management
extending battery life
● Internet Modem / LAN protection via
RJ-11/45 plug
● USB communication port providing UPS
managements
● Borri Power Guardian user-friendly UPS
management software free
downloadable at www.borri.it/support
(for more info see p.10).
0 2 4 6 8 10 12 14
2000 VA
1500 VA
1000 VA
850 VA
650 VA
450 VA
4
GIOTTO technical data
Rating (VA) 450 650 850 1000 1500 2000
Nominal power (W) 270 380 500 600 900 1200
UPS dimensions WxDxH (mm) 100x292x140 148x315x198
UPS weight (kg) 4 5 5.5 9 10.5 11.8
Input
Connection type 1 IEC 320-C14
Nominal voltage 230 Vac
Voltage range 160÷290 Vac
Frequency and range 50/60 Hz, 45÷65 Hz
Output
Connection type 1 IEC 320-C13 and 1 Schuko 4 IEC 320-C13 and 1 Schuko
Nominal voltage 230 Vac single phase
Frequency 50/60 Hz
Waveform Simulated sine wave
Battery
50% load 8 10 11 13 8 9
Autonomy time (min) ◆
100% load 3 3 3 3 3 3
Connectivity and function extensions
Front panel LCD, ON/OFF button
Included: USB.
Communication
Compatible platforms: Microsoft Windows, Linux, Mac
Environmental
Operating temperature range 0°C ÷ +40°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 with reduction of 0.5% per 100 m
Audible noise at 1m (dBA) <40
Relative humidity 0-95%
Standards and certifications
Marking CE
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Quality assurance, Environment,
ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007
Health and Safety
◆ Measurement conditions: optimised parameters, battery full charged, Power Factor (PF) 0.6
5
GALILEO
1000-3000 VA
On-line 1-phase
For networking
equipment Features and benefits ● Active harmonic power quality control
ensuring 0.99 input PF and THDi<3% for
Ideal for small and ● On-line double conversion UPS from maximum compatibility with sources
medium 1000 to 3000 VA, Tower and 2U ● Automatic self test and advanced battery
enterprises
Rack/Tower from three to six output
receptacles (IEC 320-C13) and one or
management maximizing battery
performance and extending battery life
two Schuko ● Battery extension box allowing
● Rack/Tower convertible design to additional autonomy time to be quickly
protect your investment when migrating added
from tower to rack-mount environment. ● Remote power off for immediate UPS
Both UPS and display panel can be shutdown in case of emergency
rotated
● USB communication port providing UPS
● Easy installation and set up,
management
user-replaceable and upgradable
● One slot auto-sensing communication
battery
cards
● Intuitive LCD display providing
● Borri Power Guardian user-friendly
easy-to-read UPS status and power
information UPS management software with alerts
upon main power failures and system
● Audible alarm alerts upon utility power
shutdown notification via sms and
and UPS status change email (for more info see p.10), free
● Smart cooling system ensuring further downloadable at www.borri.it/support
energy savings
● Programmable switched outlet group for
setting load priorities
Main options
● SNMP card to send UPS status to BMS’s
by Ethernet connection and SNMP
or ModBus over IP protocol to monitor
UPS status by any internet browser from
Autonomy time in minutes for Rack/Tower UPS workstations and to receive SMS or
e-mail alerts from the UPS on any
0 10 20 30 40 50 60 70 80 portable device
● Contact relay card to send UPS status to
PLC’s, SCADA’s or AS400’s by voltage
3 kVA
free SPDT contacts
● Additional battery charger for external
battery box
2 kVA (for more info visit www.borri.it)
1 kVA
0 10 20 30 40 50 60 70 80
3 kVA
2 kVA
1 kVA
6
GALILEO technical data
UPS Type T* T* T* RT (2U)** RT (2U)** RT (2U)**
Rating (VA) 1000 2000 3000 1000 2000 3000
Nominal power (W) 900 1800 2700 900 1800 2700
UPS dimensions WxDxH (mm) 144x367x236 151x444x322 189x444x322 440x390x88 440x475x88 440x600x88
UPS weight (kg) 11.2 18.8 24.9 12.0 17.0 26.5
Input
Connection type 1 IEC 320-C14
Nominal voltage 230 Vac single phase
Voltage range 195÷260 Vac
Frequency and range 50/60 Hz, 45÷65 Hz
Power factor 0.98 0.99
Current distortion (THDi) <3%
Output
3 IEC 320-C13 3 IEC 320-C13 6 IEC 320-C13
Connection type 3 IEC 320-C13 6 IEC 320-C13
1 Schuko 2 Schuko 2 Schuko
Nominal voltage 230 Vac +/-1% single phase
Frequency 50/60 Hz
Power factor Any power factor up to 0.9 lagging or leading without power derating
Overload capability 105% continuous, 106-120% for 30 seconds, 121-150% for 10 seconds, >150% immediately transfer to bypass
Mode of operation On-line, Eco mode
Battery
*Tower **Rack/Tower ◆ Measurement conditions: optimised parameters, battery full charged, Power Factor (PF) 0.7
7
LEONARDO
6-10 kVA
On-line 1-phase
For server rooms
TLC equipment Features and benefits ● Automatic self test and advanced battery
management maximizing battery
Emergency and ● On-line double conversion UPS from 6 to performance and extending battery life
safety systems 10 kVA, Tower and 2U or 3U Rack/Tower ● Battery extension box allowing additional
● Parallel redundant configuration maxi autonomy time to be quickly added
mizing the availability ● Remote emergency power off to
● Rack/Tower convertible design to guarantee your piece of mind in critical
protect your investment when migrating applications
from tower to rack-mount environment. ● Internal manual bypass for safe and easy
Both UPS and display panel can be maintenance
rotated ● RS232 communication port providing
● Easy installation and set up, user-repla- UPS management
ceable and upgradable battery ● Two slots auto-sensing communication
● Intuitive LCD display providing easy-to- cards
read UPS status and power information ● Borri Power Guardian user-friendly
● Audible alarm alerts upon utility power UPS management software with alerts
and UPS status change upon main power failures and system
● Smart cooling system ensuring further shutdown notification via sms and
energy savings email (for more info see p.10), free
● Active harmonic power quality control
downloadable at www.borri.it/support
ensuring 0.99 input PF and THDi<3% for
maximum upstream sources Main options
● SNMP card to send UPS status to BMS’s
by Ethernet connection and SNMP
or ModBus over IP protocol to monitor
UPS status by any internet browser from
workstations and to receive SMS
or e-mail alerts from the UPS on any
Autonomy time in minutes for Rack/Tower UPS portable device
● Contact relay card to send UPS status to
0 10 20 30 40 50 60 70 80 PLC’s, SCADA’s or AS400’s by voltage
free SPDT contacts
10 kVA
0 10 20 30 40 50 60 70 80
10 kVA
6 kVA
8
LEONARDO technical data
UPS Type T* T* RT (2U)*** RT (4U)** RT (3U)***
Rating (kVA) 6 10 6 6 10
Nominal power (kW) 5.4 9 5.4 5.4 9
UPS dimensions WxDxH (mm) 290x645x748 290x645x748 440x680x88 440x680x176 440x680x132
UPS weight (kg) 86 96 24 52 26
Input
Connection type Hardwired 2w (input), 2w (bypass) Hardwired 2w (input)
Nominal voltage 230 Vac single phase
Voltage range 195÷260 Vac
Frequency and range 50/60 Hz, 45÷65 Hz
Power factor 0.99
Current distortion (THDi) <6%
Output
Connection type Hardwired 2w
Nominal voltage 230 Vac +/- 1% single phase
Frequency 50/60 Hz
Power factor Any power factor up to 0.9 lagging or leading without power derating
Overload capability 104% continuous, 105-150% for 160 seconds, >150% immediately transfer to bypass
Mode of operation On-line, Eco mode
Battery
*Tower with internal battery **Rack/Tower with internal battery ***Rack/Tower without internal battery ◆ Measurement conditions: optimised parameters, battery full charged, cos Ø 0.7
9
Single phase UPS
software
10
B8031/B8033FXS
10-20 kVA
For servers
TLC equipment
Emergency and
safety systems
Industrial
automation
B8031/B8033FXS
10 to 20 kVA
On-line double
conversion
Transformer free
Full IGBT technology
Paralleling up to 120 kVA
11
B8031/B8033FXS
10-20 kVA
for servers
TLC equipment
Emergency and Features and benefits Main options
safety systems ● High double conversion efficiency and ● Isolation transformer.
Industrial ECO mode for low running costs and ● Transformers/autotransformers for
automation environmental impact. voltage adjustment.
● Transformer free design for light small
● Battery voltage temperature
size layout. compensation.
● Removable power modules architecture
● External maintenance bypass
and built-in diagnostics for easy wall-mounted box.
maintenance and very low MTTR.
● Battery fuse switch wall-mounted box.
● Hot connection/disconnection of
parallel units for easy system resizing. ● Associatedbattery cabinets for long
autonomy times.
● Full IGBT technology and electronic
PFC, ensuring 0.99 input PF and ● Parallel kit for load sharing.
THDi<3% for maximum upstream ● Load-sync for single UPS units.
sources compatibility.
● Input
terminals for remote EPO, external
● Wide range of configurations with manual bypass auxiliary contact,
internal batteries for low TCO compact diesel mode.
solutions.
● Separate bypass input for B8033FXS.
● High power battery charger, suiting
long autonomy applications.
● Dual DSP plus microcontroller logics for
top performance and reliability.
● CAN-bus based distributed parallel
control ensuring high load sharing
accuracy and no single point of failure.
● Comprehensive set of communication
options for total remote monitoring of
equipment operation.
● Included bypass contactor for
complete backfeed protection and
operators’ safety without additional
installation costs.
● Fully compliance with all international
product standards for maximum quality
guarantee.
0 5 10 15 20 25 30 35 40 45 50
20 kVA
15 kVA
10 kVA
12
B8031FXS - B8033FXS technical data
Rating (kVA) 10 15 20
Nominal power (kW) 9 13.5 18
UPS dimensions WxDxH (mm) 450x670x1200
UPS weight (kg) 100 110 110
UPS weight with internal
Max.285 Max.275 Max.275
battery (kg)
External battery module
500x670x1200
dimensions WxDxH (mm)
Battery configuration
Internal or external, 360÷372 cells, VRLA (other options)
Max autonomy with int. battery 70% load (min) 49 24 12
Input B8031FXS (10-15-20 kVA) B8033FXS (10-15-20 kVA)
Connection type Hardwired 4w (rectifier), 2w (bypass) Hardwired 4w (separate bypass input available on request)
400 Vac 3-phase with neutral (rectifier) 400 Vac 3-phase with neutral (rectifier)
Nominal voltage
220/230/240 Vac 1-phase (bypass) 380/400/415 Vac 3-phase with neutral (bypass)
Voltage tolerance -20%, +15%
Frequency and range 50/60 Hz (45÷65 Hz)
Power factor 0.99
Current distortion (THDi) <3%
Output B8031FXS (10-15-20 kVA) B8033FXS (10-15-20 kVA)
Connection type Hardwired 2w Hardwired 4w
Nominal voltage 220/230/240 Vac 1-phase 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Voltage regulation ±1% static; dynamic: IEC/EN 62040-3 Class 1
Power factor up to 0.9, lagging or leading without power derating
Inverter: 101÷125% for 10 min, 126÷150% for 30 s, >150% for 10 s;
Overload capacity
bypass: 150% continuous, 1000% for 1 cycle
Efficiency (AC/AC)* up to 98%
Classification as per
VFI-SS-111
IEC/EN 62040-3
Connectivity and function extensions
Front panel
Graphic display, mimic LED panel and keyboard, local EPO
Remote communication Included: remote communication
terminal block for battery breaker auxiliary contact.
Optional: input terminal block (remote emergency power off, battery circuit breaker aux. cont.,
external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont.); SNMP adapter (Ethernet),
Web interface (Ethernet), from ModBus-RTU to PROFIBUS DP adapter; SPDT contact relay board;
remote system monitoring panel; UPS managing and server shutdown software
Optional function extensions Isolation transformer; transformers/autotransformers for voltage adjustment;
external maintenance bypass; custom battery cabinets; wall-mounted battery fuse
switch box; battery thermal probe; parallel kit, load-sync for single UPS
System
Protection degree IP 20
Colour RAL 7016
Installation layout 10 cm wall-gap, side by side installation allowed
Accessibility Front and top access, bottom cable entry
13
B8031/8033FXS series options
Description When do I use it
LOAD A LOAD B
INCLUDED
Input terminal block for external manual bypass When there is an external maintenance bypass switch,
switch auxiliary contact for state monitoring
Input terminal block for external battery switch When there is an external battery switch,
auxiliary contact for state monitoring
INCLUDED
14
INGENIO
30-50 kVA
For server rooms
TLC equipment
Emergency and
safety systems
Industrial
automation
INGENIO
30 to 50 kVA
Three phase
On-line
double conversion
Transformer free
Full IGBT technology
Paralleling up to 300 kVA
15
INGENIO
30-50 kVA
For server rooms
TLC equipment
Emergency and Features and benefits Main options
safety systems ● High double conversion efficiency and ● Isolation transformer.
Industrial ECO mode for low running costs and ● Transformers/autotransformers for
automation environmental impact. voltage adjustment.
● Transformer free design for light small
● Battery voltage temperature
size layout. compensation.
● Removable power modules architecture
● External maintenance bypass
and built-in diagnostics for easy wall-mounted box.
maintenance and very low MTTR.
● Battery fuse switch wall-mounted box.
● Hot connection/disconnection of
parallel units for easy system resizing. ● Associatedbattery cabinets for long
autonomy times.
● Full IGBT technology and electronic
PFC, ensuring 0.99 input PF and ● Parallel kit.
THDi<3% for maximum upstream ● Load-sync for single UPS units.
sources compatibility.
● Input
terminals for remote EPO, external
● Wide range of configurations with manual bypass auxiliary contact,
internal batteries for low TCO compact diesel mode.
solutions.
● Separate bypass input.
● High power battery charger, suiting
● Backfeed protection bypass contactor.
long autonomy applications.
● Dual DSP plus microcontroller logics for
top performance and reliability.
● CAN-bus based distributed parallel
control ensuring high load sharing
accuracy and no single point of failure.
● Comprehensive set of communication
options for total remote monitoring of
equipment operation.
● Fully compliance with all international
product standards for maximum quality
guarantee.
0 5 10 15 20 25
50 kVA
40 kVA
30 kVA
16
INGENIO technical data
Rating (kVA) 30 40 50
Nominal power (kW) 27 36 45
UPS dimensions WxDxH (mm) 500x940x1500
UPS weight (kg) 140 150 190
UPS weight
500 510 550
with int. battery (kg)
Battery configuration Internal or external, 360÷372 cells, VRLA (other options)
Max autonomy
with int. battery 24 16 12
70% load (min)
Input
Connection type Hardwired 4w (separate bypass input available on request)
400 Vac 3-phase with neutral (rectifier)
Nominal voltage
380/400/415 Vac 3-phase with neutral (bypass)
Voltage tolerance -20%, +15% (rectifier) ±10% (bypass)
Frequency and range 50/60 Hz, 45÷65 Hz
Power factor 0.99
Current distortion (THDi) <3%
Output
Connection type Hardwired 4w
Nominal voltage 380/400/415 3-phase with neutral
Frequency 50/60 Hz
Voltage regulation ±1% static; dynamic: IEC/EN 62040-3 Class 1
Power factor up to 0.9, lagging or leading without power derating
Overload capacity Inverter: 101÷125% for 10 min, 126÷150% for 30 s, >150% for 100 ms, bypass: 150% continuous, 1000% for 1 cycle
Efficiency (AC/AC)* up to 98%
Classification as per
VFI-SS-111
IEC/EN 62040-3
Connectivity and function extensions
Front panel Graphic display, mimic LED panel and keyboard, local EPO
Remote communication Included: RS232 card, USB; terminal block for battery breaker auxiliary contact
Optional: input terminal block (remote emergency power off,
external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont.);
SNMP adapter (Ethernet), Web interface (Ethernet), from ModBus-RTU to PROFIBUS DP adapter; SPDT contact relay board;
remote system monitoring panel; UPS managing and server shutdown software
Optional function extension Isolation transformer; transformers/autotransformers for voltage adjustment; external maintenance bypass; custom battery cabinets;
wall-mounted battery fuse switch box; battery thermal probe; parallel kit and load-sync for single UPS
System
Protection degree IP 20
Colour RAL 9005
Installation layout Wall and side by side installation allowed; 50 cm clearance on one side with internal battery
Other features
Environmental
Operating temperature range 0°C ÷ +40°C
Storage temperature range -10°C ÷ +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) <52
Standards and certifications
Quality assurance,
ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007
environment, health and safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environmental aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3 VFI-SS-111
Protection degree IEC 60529
Marking CE
17
INGENIO 30-40-50 kVA series options
Description When do I use it
LOAD A LOAD B
When the Emergency Power Off (EPO) has to be When there is an external maintenance bypass switch,
commanded by a remote control button for state monitoring
Input terminal block for external battery switch When there is an external battery switch,
auxiliary contact for state monitoring
INCLUDED
18
INGENIO PLUS
60-160 kVA
For small-medium
data centers
Process automation
Service industry
INGENIO PLUS
60 to 160 kVA
Three phase
On-line double
conversion
Transformer free
Full IGBT technology
Paralleling up to 960 kVA
re
c hu
o
br lable
t e i
m pl ava
e
Co
19
INGENIO PLUS
60-160 kVA
For small-medium
data centers
Process automation Features and benefits Main options
Service industry ● Green Conversion technology, high ● Isolation transformer.
efficiency even at light load and the
lowest TCO in its category. ● Transformers/autotransformers for
voltage adjustment.
● Ultra High Efficiency mode, the ultimate
innovation protecting high immunity ●Battery voltage temperature
grade applications, providing 99% compensation.
efficiency and lowest operational ● External maintenance bypass
expenditure. wall-mounted box.
● Full rated output power, ensuring optimal ● Battery fuse switch wall-mounted box.
UPS sizing and utilization.
● Associated battery cabinets for long
● Transformer free design for compact, autonomy times.
light and sustainable systems.
● Parallel kit for load sharing.
● Full
IGBT technology and electronic PFC,
ensuring 0.99 input PF and THDi<3% for ● Load-sync for single UPS units.
maximum upstream sources compatibility.
● Load-sync box for two set of
● Internal
battery configurations paralleled UPS.
up to 80 kVA for less floor space and
maximum flexibility ●Local tripping device for bypass
disconnector.
● Dynamic Charging Mode (DCM) for
maximum versatility in long autonomy ● Tripping coil for bypass disconnector
and low charging time applications. for complete upstream protection and
operator’s safety without additional
● Intermittent battery charge, with installation cost.
adjustable cycle (27-3 standard cycle)
providing capital expenditure protection ● Touch screen display.
and extreme efficiency savings.
● Common battery management for even
more compact and cost saving UPS
systems
● Load based unit shutdown for highest
efficiency in light loaded parallel
systems.
● Comprehensive set of communication
options for total remote monitoring of
equipment operation.
● Fully compliance with all international
product standards for maximum quality
guarantee.
0 5 10 15 20
80 kVA
60 kVA
20
INGENIO PLUS technical data
Rating (kVA) 60 80 100 125 160
Nominal power (kW) 60 80 100 125 160
UPS dimensions WxDxH (mm) 560x940x1800
UPS weight (kg) 250 300 320 360 380
UPS weight with int. battery (kg) 800 850 - - -
Battery configuration Internal or external, 360÷372 cells,
External 360÷372 cells, VRLA (other options)
VRLA (other options)
Max autonomy with int. battery
16 11 - -
70% load (min)
Input
Connection type Hardwired 4w (rectifier), 4w (bypass)
Nominal voltage 400 Vac 3-phase with neutral (rectifier)
380/400/415 Vac 3-phase with neutral (bypass)
Voltage tolerance -20%, +15% (rectifier) ±10% (bypass)
Frequency and range 50/60 Hz, 45÷65 Hz
Power factor >0.99
Current distortion (THDi) <3%
Output
Connection type Hardwired 4w
Nominal voltage 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Voltage regulation ±1% static; dynamic: IEC/EN 62040-3 Class 1
Power factor up to 1, without power derating
Overload capacity Inverter: 101÷125% for 10 min, 126÷150% for 30 s, >150% for 0.1 s;
bypass: 150% continuous, 1000% for 1 cycle
Efficiency (AC/AC)* up to 99%
Classification as per
VFI-SS-111
IEC/EN 62040-3
Connectivity and function extensions
Front panel Graphic display, mimic LED panel and keyboard, local EPO
Remote communication Included: serial RS232 and USB, backfeed protection monitoring contact,
input terminal block (remote emergency power off, battery circuit breaker aux. cont.,
external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont.).
Optional: SNMP adapter (Ethernet), Web interface (Ethernet), from ModBus-RTU to PROFIBUS DP adapter.
SPDT contact relay board; remote system monitoring panel; UPS managing and server shutdown software
Optional function extension Isolation transformer; transformers/autotransformers for voltage adjustment;
external maintenance bypass; custom battery cabinets; wall-mounted battery fuse
battery thermal probe; parallel kit, load-sync for single UPS and load-sync box (2 UPS systems)
System
Protection degree IP20
Colour RAL 9005
Installation layout Wall and side by side installation allowed, 80 cm clearance on one side only with internal battery
Accessibility Front access, side access (only with internal battery), bottom cable entry
Other features
Environmental
Operating temperature range 0°C ÷ +40°C
Storage temperature range -10°C ÷ +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) <60
Standards and certifications
Quality assurance,
ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007
environment, health and safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environmental aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3
Protection degree IEC 60529
Marking CE
21
INGENIO PLUS 60-160 kVA series options
Description When do I use it
LOAD A LOAD B
LOAD SYNC
To synchronize the output of two paralleled UPS systems
BOX Load-sync box for two sets of paralleled UPS for no-break load transfers by
downstream static transfer switches
LOAD A LOAD B
Input terminal block for external manual bypass When there is an external maintenance bypass switch,
switch auxiliary contact for state monitoring
Input terminal block for external battery switch When there is an external battery switch,
auxiliary contact for state monitoring
22
B9000FXS
60-300 kVA
For medium data centers
Process automation
Medical equipment
Emergency and
safety systems
B9000FXS
Three phase
On-line double conversion
Full IGBT technology
Paralleling up to 1.8 MVA
23
B9000FXS
60-300 kVA
For medium data centers
Process automation
Medical equipment Features and benefits Main options
Emergency and ● High double conversion efficiency and ● Backfeed protection bypass contactor.
safety systems ECO mode for low running costs and ● Bypass isolation transformer.
environmental impact.
● Transformers/autotransformers for
● Front access to all critical components
voltage adjustment.
for easy maintenance.
● Battery voltage temperature
● Built-in inverter transformer for DC/AC
compensation.
galvanic protection of industrial type
loads. ● External maintenance bypass
wall-mounted box.
● Hot connection/disconnection of parallel
units for easy system resizing. ● Battery fuse switch wall-mounted box.
● Full IGBT technology and electronic PFC, ● Associated battery cabinets for long
ensuring 0.99 input PF and THDi<3% autonomy times.
for maximum upstream sources ● Parallel kit for load sharing.
compatibility.
● Load-sync for single UPS units.
● Accurate battery management providing
ripple current minimization charge ● Load-sync box for two set of
current/voltage control as per batteries paralleled UPS.
manufacturers’ specifications and ● Top cable entry.
automatic/manual battery test
for maximum battery expected life
preservation.
● Dynamic Charging Mode (DCM) for
maximum versatility in long autonomy
and low charging time applications.
● Smart parallel management in load
sharing, load synchronization of single
UPS systems and load synchronization
of two paralleled systems for optimum
protection.
● Dual DSP plus microcontroller logics for
top performance and reliability.
● CAN-bus based distributed parallel
control ensuring high load sharing
accuracy and no single point of failure in
parallel systems.
● Comprehensive set of communication
options for total remote monitoring of
equipment operation. Dynamic Charging Mode (DCM)
● Fully compliance with all international The battery charging current can be set
product standards for maximum quality above the nominal, up to the DCM limit,
guarantee. in order to manage high capacity battery
packs. The extra charging power is fed to
the battery, as long as the load does not
requires it. This is a firmware enabled
feature.
Bypass
Mains Output
24
B9000FXS technical data
Rating (kVA) 60 80 100 125 160 200 250 300
Nominal power (kW) 54 72 90 112.5 144 180 225 270
Dimensions WxDxH (mm) 815x825x1670 1200x860x1900
UPS weight (kg) 570 600 625 660 715 970 1090 1170
Battery configuration External, 300÷312 cells, VRLA (other options)
Input
Connection type Hardwired 3w (rectifier), 4w (bypass)
Nominal voltage 400 Vac 3-phase (rectifier)
380/400/415 Vac 3-phase with neutral (bypass)
Voltage tolerance -20%, +15%
Frequency and range 50/60 Hz, 45÷65 Hz
Power factor 0.99
Current distortion (THDi) <3%
Output
Connection type Hardwired 4w
Nominal voltage 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Voltage regulation ±1% static; dynamic: IEC/EN 62040-3 Class 1
Power factor up to 0.9, lagging or leading without power derating
Overload capacity Inverter: 101÷125% for 10 min, 126÷150% for 1 min, 151÷199% for 10 s,
200% for 100 ms; bypass: 150% continuous, 1000% for 1 cycle
Efficiency (AC/AC)* up to 98%
Classification as per
VFI-SS-111
IEC/EN 62040-3
Connectivity and function extensions
Front panel Graphic display, mimic LED panel and keyboard, local EPO
Remote communication Included: serial RS232 and USB; input terminal block for: remote emergency
power off (REPO), battery circuit breaker aux. cont., external maintenance bypass
circuit breaker aux. cont., diesel mode aux. contact.
Optional: SNMP adapter (Ethernet), Web interface (Ethernet), ModBus-TCP/IP
(Ethernet); ModBus-RTU (RS485); ModBus-RTU to PROFIBUS DP adapter;
SPDT contact relay board; remote system monitoring panel;
UPS managing and server shutdown software
Optional function extensions
Isolation transformer; transformers/autotransformers for voltage adjustment;
external maintenance bypass; custom battery cabinets; wall-mounted battery fuse
switch box; battery thermal probe; parallel kit, top cable entry;
load-sync for single UPS and load-sync box (2 UPS systems); backfeed protection
System
Protection degree IP 20 (other options)
Colour RAL 7016 (other options)
Installation layout Wall, back to back and side by side installation allowed
Accessibility Front and top access, bottom cable entry
Other features
Environmental
Operating temperature range 0°C ÷ +40°C
Storage temperature range -10°C ÷ +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 with reduction of 0.5% per 100 m
Audible noise at 1m (dBA) <62
Standards and certifications
Quality assurance,
environment, health and ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007
safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environmental aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3 (VFI-SS-111)
Protection degree IEC 60529
Marking CE
25
B9000FXS series options
Description When do I use it
LOAD A LOAD B
LOAD SYNC
To synchronize the output of two paralleled UPS systems
BOX Load-sync box for two sets of paralleled UPS for no-break load transfers by
downstream static transfer switches
LOAD A LOAD B
Top
To allow input and output cable entry from the
cable Top cable entry (in extended cabinet)
entry top of the unit
Input terminal block for external manual bypass When there is an external maintenance bypass switch,
switch auxiliary contact for state monitoring
Input terminal block for external battery switch When there is an external battery switch,
auxiliary contact for state monitoring
26
B9600FXS
400-800 kVA
For data centers
Process industry
Infrastructure
B9600FXS
400 to 800 kVA
Three phase On-line double
conversion Full IGBT technology
Paralleling up to 4.8 MVA
27
B9600FXS
400-800 kVA
For data centers
Process industry
Infrastructure Features and benefits Main options
● High double conversion efficiency and ● Manual bypass in extended cabinet
ECO mode for low running costs and ● Backfeed protection
environmental impact.
● Bypass isolation transformer.
● Front access to all critical components
for easy maintenance. ● Transformers/autotransformers for
voltage adjustment.
● Built-in inverter transformer for DC/AC
galvanic protection of industrial type ● Battery voltage temperature
loads. compensation.
● Included backfeed bypass contactor ● External maintenance bypass
for complete protection and wall-mounted box.
operators’ safety without additional ● Battery fuse switch wall-mounted box.
installation costs. ● Associatedbattery cabinets for long
● Hot connection/disconnection of parallel autonomy times.
units for easy system resizing.
● Parallel kit for load sharing.
● Full IGBT technology and electronic PFC,
ensuring 0.99 input PF and THDi<3% ● Load-sync for single UPS units.
for maximum upstream sources ● Load-sync box for two set of
compatibility. paralleled UPS.
● Accurate battery management providing
● Top cable entry.
ripple current minimization charge
current/voltage control as per batteries
manufacturers’ specifications and
automatic/manual battery test
for maximum battery expected life Dynamic Charging Mode (DCM)
preservation. The battery charging current can be set
● Dynamic Charging Mode (DCM) for above the nominal, up to the DCM limit,
maximum versatility in long autonomy in order to manage high capacity battery
and low charging time applications. packs. The extra charging power is fed to
● Smart parallel management in load the battery, as long as the load does not
sharing, load synchronization of single requires it. This is a firmware enabled
UPS systems and load synchronization feature.
of two paralleled systems for optimum
protection.
● Dual DSP plus microcontroller logics for
top performance and reliability. Bypass
● CAN-bus based distributed parallel
control ensuring high load sharing
accuracy and no single point of failure in Mains Output
parallel systems.
● Comprehensive set of communication
options for total remote monitoring of
equipment operation.
● Fully compliance with all international
product standards for maximum quality
guarantee.
28
B9600FXS technical data
Rating (kVA) 400 500 600 800
Nominal power (kW) 360 450 540 720
Dimensions WxHxD (mm) 1990x990x1920 2440x990x2020 2440x990x2020 3640x990x1920
UPS weight (kg) 1820 2220 2400 3600
Battery configuration External, 300÷312 cells, VRLA (other options)
Input
Connection type Hardwired 3w (rectifier), 4w (bypass)
Nominal voltage 400 Vac 3-phase (rectifier)
380/400/415 Vac 3-phase with neutral (bypass)
Voltage tolerance -20%, +15%
Frequency and range 50/60 Hz, 45÷65 Hz
Power factor 0.99
Current distortion (THDi) <3%
Output
Connection type Hardwired 4w
Nominal voltage 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Voltage regulation ±1% static; dynamic: IEC/EN 62040-3 Class 1
Power factor up to 0.9, lagging or leading without power derating
Overload capacity Inverter: 101÷125% for 10 min, 126÷150% for 1 min, 151÷199% for 10 s,
200% for 100 ms; bypass: 150% continuous, 1000% for 1 cycle
Efficiency (AC/AC)* up to 98%
Classification as per
VFI-SS-111
IEC/EN 62040-3
Connectivity and function extensions
Front panel Graphic display, mimic LED panel and keyboard, local EPO
Remote communication Included: serial RS232 and USB; input terminal block for: remote emergency
power off (REPO), battery circuit breaker aux. cont., external maintenance bypass
circuit breaker aux. cont., diesel mode aux. contact.
Optional: SNMP adapter (Ethernet), Web interface (Ethernet), ModBus-TCP/IP
(Ethernet); ModBus-RTU (RS485); ModBus-RTU to PROFIBUS DP adapter;
SPDT contact relay board; remote system monitoring panel;
UPS managing and server shutdown software
Optional function extensions Isolation transformer; transformers/autotransformers for voltage adjustment;
external maintenance bypass; custom battery cabinets; wall-mounted battery fuse
switch box; battery thermal probe; parallel kit;
top cable entry; load-sync for single UPS and load-sync box (2 UPS systems)
System
Protection degree IP 20 (other options)
Colour RAL 7016 (other options)
Installation layout Wall, back to back and side by side installation allowed
Accessibility Front and top access, bottom cable entry
Other features
Environmental
Operating temperature range 0°C ÷ +40°C
Storage temperature range -10°C ÷ +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 with reduction of 0.5% per 100 m
Audible noise at 1m (dBA) <62
Standards and certifications
Quality assurance,
environment, health and ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007
safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environmental aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3
Protection degree IEC 60529
Marking CE
29
B9600FXS series options
Description When do I use it
LOAD A LOAD B
LOAD SYNC
To synchronize the output of two paralleled UPS systems
BOX Load-sync box for two sets of paralleled UPS for no-break load transfers by
downstream static transfer switches
LOAD A LOAD B
Top To allow input and output cable entry from the top of the unit.
Top cable entry (in extended cabinet)
cable B9600FXS series feature optional maintenance
entry Maintenance bypass (in extended cabinet)
bypass for cost reduction when this is externally provided
Input terminal block for external manual bypass When there is an external maintenance bypass switch,
switch auxiliary contact for state monitoring
Input terminal block for external battery switch When there is an external battery switch,
auxiliary contact for state monitoring
30
UPSAVER
100 kW-12.8 MW
4.0 UPS dedicated
to ICT for unmatched
energy savings
UPSaver
100 kW to 12.8 MW
Modular three phase
re
c hu
o
br lable
t e i
m pl ava
e
Co
31
UPSAVER
100 kW-12.8 MW
4.0 UPS dedicated
to ICT for unmatched
energy savings Main options
● Centralized static bypass for UPSaver
GPU (Growing Power Unit).
● Modular battery for UPSaver GPU.
32
UPSAVER technical data
Input
Connection type Hardwired 4w (rectifier), 4w (bypass)
Nominal voltage 400 Vac 3-phase with neutral (rectifier), 380/400/415 Vac 3-phase with neutral (bypass)
Voltage tolerance -20%, +15% (rectifier), ±10% (bypass)
Frequency and range 50/60 Hz, 45÷65 Hz
Power factor 0.99
Current distortion (THDi) <3%
Output
Connection type Hardwired 4w
Nominal voltage 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Voltage regulation (VFI) ±1% static; dynamic: IEC/EN 62040-3 Class 1
Power factor Any power factor (leading or lagging) up to 1, without power derating
Overload capability Inverter: 101÷125% for 10 min; 126÷150% for 1 min; bypass: 150% continuous, 1000% for 1 cycle
AC/AC efficiency certified by TÜV Up to 99.5%
Classification as per IEC/EN 62040-3 VFI-SS-111
Environmental
Operating temperature 0°C ÷ +40°C
Storage temperature -10°C ÷ +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 with reduction of 0.5% per 100 m
Audible noise at 1m (dBA) <50 (UHE)
System
Protection degree IP 20
Colour RAL 9005
Installation layout Wall, back to back and side by side installation allowed
Accessibility Front and top access, bottom and top cable entry
Parallel configuration Up to 8 UPS, for a total of 12.8 MW
Standards and certifications
Quality assurance, environment,
ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007
health and safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Test and performance IEC/EN 62040-3
Protection degree IEC 60529
Marking CE
* A Fixed Power Unit (FPU) is made of a 100 kW or 200 kW Basic Power Unit (BPU) plus all circuit breakers and control logics for use in stand alone configuration
◆ A 100 kW Growing Power Unit (GPU) is made of many 100 kW Basic Power Units (BPU) plus an I/0 module including all circuit breakers and control logics required
for use in modular configuration
✪ A 200 kW Growing Power Unit (GPU) is made of many 200 kW Basic Power Units (BPU) plus a I/0 module including all circuit breakers and control logics required
for use in modular configuration
33
UPSAVER series options
Description When do I use it
LOAD A LOAD B
LOAD SYNC
To synchronize the output of two paralleled UPS systems
BOX Load-sync box for two sets of paralleled UPS for no-break load transfers by
downstream static transfer switches
LOAD A LOAD B
Backfeed protection bypass contactor for To be fully protected against backfeed energy upon static
UPSaver GPU bypass failure
INCLUDED
Tripping coil for bypass disconnector for To be fully protected against backfeed energy upon static
UPSaver FPU bypass failure. Detection circuit is included
Input terminal block for external manual bypass When there is an external maintenance bypass switch,
switch auxiliary contact for state monitoring
INCLUDED
Input terminal block for external battery switch When there is an external battery switch,
auxiliary contact for state monitoring
INCLUDED
34
Three phase UPS
TELESERVICE
35
STS100/STS300
25-3000 A
Static Transfer Switches
Bypass 1
Source 1 Input 1
Output
Loads
Source 2 Input 2
Bypass 2
36
STS100 / STS300 technical data
Rating (A) 25 50 80 100 100 250 400 630 800
STS100 STS300
Dimensions WxHxD (mm) 820x835x1475 (custom layout on request) 820x835x1475 1220x860x1900
Weight (kg) 150 190 220 265 265 290 305 615 660
Input
Connection type Hardwired 2w Hardwired 4w
Nominal voltage 110/115/120/220/230/240/277 Vac 1-phase 208/380/400/415/440/480 Vac 3-phase with neutral
Voltage tolerance ±10% (up to ±20% on request)
Frequency and range 50/60 Hz, ±2 Hz (up to ±4 Hz on request)
Source harmonic voltage
unlimited (>20% THD transfer time ≤10ms)
content
Transfer phase angle 5° ÷ 30°
Output
Connection type Hardwired 2w Hardwired 4w
Nominal voltage 110/115/120/220/230/240/277 Vac 1-phase 208/380/400/415/440/480 Vac 3-phase with neutral
Frequency 50/60 Hz
Transfer time ≤4 ms
Transfer mode Break before make, transfer inhibit on fault
Load power factor 1 to 0.3
Maximum crest factor 3:1
THD current fedback
unlimited
from load
Overload capacity 125% for 30 min, 150% for 10 min, 200% for 30 s, 2000% for 1 cycle, 4000% for ½ cycle
Rendimento (AC/AC) >99%
Connectivity and function extensions
Front panel Mimic LED panel and keyboard Graphical LCD display, mimic LED panel and keyboard
Remote communication Included: dry contact relay card. Included: Dry contact relay card, RS232 and RS485 serial ports,
Optional: RS232 or RS485 serial port, ModBus-RTU protocol.
additional dry contact relay board Optional: additional dry contact relay card
Optional function extensions 2-poles configuration; plug-in circuit breakers, 4-poles configuration, plug-in circuit breakers,
operation without neutral, operation without neutral,
panel builder execution,output distribution panels, panel builder execution,
isolation transformer output distribution panels, isolation transformer
System
Protection degree IP 20 (other options)
Colour RAL 7035 (other options)
Installation layout Wall, back to back and side by side installation allowed
Accessibility Front access, bottom and top cable entry
Other ratings on request
Other
features
Environmental
Operating temperature range 0°C ÷ +40°C
Storage temperature range -10°C ÷ +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 with reduction of 0.5% per 100 m
Audible noise at 1m (dBA) <62
Standards and certifications
Quality assurance,
environment, health ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007
and safety
Safety IEC/EN 62310-1
EMC IEC/EN 62310-2
Breakers IEC/EN 60947-3
Transfer voltage limits IEEE Standard 446
Protection degree IEC 60529
Performance IEC/EN 62310-3
Marking CE
37
Borri S.p.A.
Via 8 Marzo, 2
sales@borri.it · www.borri.it
OMG60002revG - 07-2015 - Due to our policy of continuous development, data in this document is subject to change without notice and becomes contractual only after written confirmation
Catalogue
Oil & Gas
Energy
DC UPS
RTB.e RMB.e/RCB.e
50-1000 A 50-100-150 A
3 phase rectifier 1 and 3 phase
battery chargers compact rectifier
Input voltage: battery chargers
400 Vac, 3-phase, 50/60 Hz Input voltage:
Output voltage: 220/230/240 Vac, 1-phase,
50/60 Hz (RMB.e)
24/48/110/220 Vdc 400 Vac, 3-phase (RCB.e)
Output voltage:
24/48/110/220 Vdc
IRB- 3 kVA
Inverters
IMB.e/ITB.e E2001.e/E3001.e
5-200 kVA 5-200 kVA
1 and 3 phase 3/1 and 3/3 phase
DC/AC inverters on-line double
Input voltage: conversion UPS
110/125/220 Vdc Input voltage:
Output voltage: 208/400/480 Vac, 3-phase
115/120/230 Vac, Output voltage:
1-phase (IMB.e) 115/120/230 Vac,
208/400/480 Vac, 1-phase (E2001.e),
3-phase (ITB.e) 208/400/480 Vac,
3-phase (E3001.e)
Battery voltage:
110/125/220 Vdc
AC UPS
DC UPS
RMB.e/RCB.e
● Small size design for easy installation RMBe RCB.e RMBe RCB.e RCB.e
● Parallel operation for redundancy 110 Vdc 100 115 110 145 175
● Timer-controlled battery charging Options Associated battery cabinets; matching cabinets for distribution and dropping cells;
built-in battery breaker; external battery breakers in standard or Eex-d
● Battery voltage temperature
compensation wall-mounted box; battery thermal probe; block diode for parallel;
earth fault alarm; fan monitoring and alarm; control logic redundant supply
● DC earth fault monitoring and alarm
User Interface
● Fan monitoring and alarm Front panel LCD display with 4x LED set, mimic and keyboard
● Associated cabinets for batteries, Connectivity (optional) up to 2 SPDT contact relay cards, RS232 serial port, RS485 ModBus-RTU serial port,
distribution boards, dropping cells or ModBus to PROFIBUS DP adapter, Ethernet SNMP/WEB adapter,
DC/DC chopper converters. remote monitoring software
Extra options
● Customized input and output voltage ● Space heaters and panel lighting
● Analogue meters and lamps on front Maximum weight (kg) 320 360 400 440 500 550 610 320 360 400 440 470 500 550 600 730 830
panel for immediate visualisation Cooling Forced ventilation
● Customisable status and alarm LED set Efficiency 94%
● Special painting and protection degree Colour RAL 7035
up to IP54 Protection degree
IP20 (other options)
● Ambient temperature up to +55 °C. (IEC 60529)
Rackmount
Rating (kVA/kW) 3/2.4
DC input voltage 110 Vdc (88-160 Vdc range)
Nominal output voltage and frequency 230 Vac 50Hz
Extra options
● Built-in battery breaker ● AC & DC earth fault monitoring and
alarm
110÷120 Vac 800 1400 1800 800 1200 1400 1600 1800 2400
Output voltage
220÷240 Vac 800 1400 1800 800 1200 1400 1600 1800
Maximum weight (kg) 450 500 600 650 820 900 1000 460 520 620 670 750 850 950 1150 1250 1400
Cooling Forced ventilation
Efficiency 88%
Colour RAL 7035
Protection degree (IEC 60529) IP20 (other options)
OMG60003revC - 01-2014 - Due to our policy of continuous development, data in this document is subject to change without notice and becomes contractual only after written confirmation
renewable energy and storage, make Borri
battery block or cell, actual capacity a leader in this technology not only for oil
check and data logging. A manual and gas applications.
battery test mode is also included. The latest patented three-phase solution
Remote access over RS485 ModBus based on its green conversion operation
is available as an option. can guarantee the best PUE for green data
centers: proof of the ongoing company
commitment to innovation.
Based in Italy with 12,000 m2 production
space and a large full-testing area, the
company can call on more than 80 years of
experience.
Standards and certifications Borri has a strong global presence and is
represented in all 5 continents where it
can provide on-site service and technical
● support.
Marking
CE
●
Safety
IEC EN 50178, IEC EN 62040-1
●
EMC
IEC EN 61000-6-2, IEC EN 61000-6-4,
IEC EN 62040-2 Listening to our customers and
● delivering state-of-the-art,
Test and performance tailored systems has been our
IEC EN 62040-3 vocation for more than
● 80 years.
Quality, environment, health and safety
ISO 9001:2008, ISO 14001:2004,
GOST, BS OHSAS 18001:2007
Borri · Via 8 Marzo, 2 · 52010 Bibbiena (AR) Italy · Tel. +39 0575 5351 · Fax +39 0575 561811 · info@borri.it · www.borri.it
Very early warning aspirating
smoke detection.
SecuriSmoke ASD
Industries and applications Industries and applications
Large open spaces such as theatres, atriums and airport termi- Without a doubt, many companies would come to a stand-
nals pose a wide range of problems in terms of fire protection. still without a functioning ICT infrastructure. Server rooms in
Point-type smoke detectors are often ineffective due to smoke SMEs, mobile telephony base stations and large data centres
dilution and stratification. This is where SecuriSmoke ASD as- play a key role. Protecting them from fires is a complex task,
pirating smoke detectors perform reliably: these early warning as high and turbulent air currents make it difficult to detect
devices benefit from multiple alarm levels, enabling staggered diluted, early-stage smoke. With their multiple alarm levels,
responses according to the situation for the preservation of life SecuriSmoke ASD aspirating smoke detectors support
and property. appropriate interventions and enable the automatic actuation
of extinguishing systems.
2 3
Product range Product range
ASD 533
Perfect for large monitoring areas
ASD 535-1, 1 channel ASD 535-2, 2 channels ASD 535-3, 1 channel ASD 535-4, 2 channels
Smoke level indicator Smoke level indicator
■ Immune to environmental contaminants such as dust, dirt, moisture and steam ■ Compact design
■ Applications: high-bay and deep-freeze warehouses, large data centres, historic buildings, large/high halls, etc. ■ Applications: prison cells, clean rooms, laboratories, IT racks,
■ Approvals/certificates: VdS, DIBt, UL, FM, ActivFire, CCCF, EAC, SIL telecommunications equipment, etc.
■ Total length of all sampling pipes: 2 × 400 m ■ Approvals/certificates: VdS, UL, FM, ActivFire, CCCF,
■ Sound pressure level: 34 dB (A), i.e. extremely low-noise EAC, SIL
■ Protection class: IP 54 ■ Total length of all sampling pipes: 120 m
■ Permissible temperature range: −30 °C to +60 °C ■ Sound pressure level: 25 dB (A), i.e. extremely low-noise
■ Protection class: IP 54
■ Permissible temperature range: −20 °C to +60 °C
ASD 535 HD
For extreme environments
ASD 531
■ Ideal for use in corrosive environments For small monitoring areas
■ Applications: metal industry, woodworking industry,
agriculture, etc. ■ Simple three-step configuration at the device itself
■ Approvals/certificates: VdS, DIBt, UL, FM, ActivFire, (no software/PC)
CCCF, EAC, SIL ■ Applications: individual IT racks, clean rooms, false ceilings,
■ Total length of all sampling pipes: 2 × 400 m etc.
■ Sound pressure level: 34 dB (A), i.e. extremely low-noise ■ Approvals/certificates: VdS, UL, FM, ActivFire, CCCF, EAC
■ Optional surge protection ■ Total length of all sampling pipes: 75 m
■ Coated printed circuit boards ■ Sound pressure level: 25 dB (A), i.e. extremely low-noise
■ Protection class: IP 66 ■ Protection class: IP 54
■ Permissible temperature range: −30 °C to +60 °C ■ Permissible temperature range: −10 °C to +55 °C
ASD 535 HD, 1 channel ASD 535 HD, 2 channels
Smoke level indicator Smoke level indicator
4 5
Networking and operation Networking and operation
The building plan provides an overview of all the ASDs in the NetSoft enables individual selection of the graphical detector
network, including their current states. Netsoft’s graphical icons and access to the data of the networked detectors.
FidesNet: the intelligent interface offers complete flexibility when creating and import- You can also configure the devices directly from the graphical
ing simple networked floor plans as well as complex building overview. To display the live data of the detectors or carry out
graphics. The states of the networked ASDs can be viewed further configurations and parameterisations of the individual
networking solution at a glance: the relevant ones are highlighted in colour in the
event of an alarm, malfunction or other status.
ASDs, you can start the ASD Config tool in NetSoft.
Deploying FidesNet turns SecuriSmoke ASD aspirating smoke detectors into a full-fledged, intelligent system with
central visualisation and control functions. Proven components ensure secure networking.
6 7
Planning Configuration
8 9
PRODUCT HIGHLIGHTS
Demanding applications:
every situation under control
Highly robust, whisper-quiet and precise responses to minimal amounts of smoke: SecuriSmoke ASD aspirating smoke
detectors meet the highest standards.
SecuriSmoke ASDs feature protection The sound of air being aspirated by The smoke sensor in SecuriSmoke ASDs
class IP 54 as standard: protection SecuriSmoke ASDs is barely noticeable. is designed for use in extremely sensitive
against dust, contact protection and Thanks to their minimal noise, they can environments. Its sensitivity is 0.002 %
If more than two pipes are required, pipe manifolds are a The SecuriSmoke ASD is available as a two-channel version
simple solution. These can be connected directly to the with two independent smoke detectors in the same detector
ASDs, so that they can be expanded to accommodate up housing.
to eight sampling channels.
■ Use for extinguishing actuation
■ Reduced installation work, as one
Channel and cabinet identification housing contains two detectors
Further benefits
10 11
Accessories GLOBAL PRESENCE
Securiton has a global presence. Our headquarters are located in Switzerland, and we have
subsidiaries or local staff operating in Mexico, Brazil, Spain, Russia, India, Malaysia and China.
Blow-out units Water retaining box Dirt retainer Magnet filter Flexible hoses Metal sampling Air cooler/
pipes heater
One filter for most Sampling clips of ABS and PVC pipes in
applications different diameters various colours
Premises monitoring
For the demanding protection of premises.
AC
E
ER
D
TIFIE
12 13
PRODUCT INFORMATION PRODUCT INFORMATION
Overview of the aspirating smoke detectors: ASD 535 ASD 533 ASD 532 ASD 531
Supply voltage range EN 54 10.5 to 30 VDC 10.5 to 30 VDC 14.0 to 30 VDC 14.0 to 30 VDC
FM/UL 12.4 to 27 VDC 12.4 to 27 VDC 16.4 to 27 VDC 16.4 to 27 VDC
348 mm
30/50/70 %)
290 mm
290 mm
290 mm
Number of sampling EN 54-20, Class A 2 × 18 16 8 6
holes (with ASD
EN 54-20, Class B 2 × 56 50 12 8
PipeFlow)
EN 54-20, Class C 2 × 120 50 16 12
14 15
Securiton AG
Thailand
Malaysia
Singapore
Factory
Sales & Technical
Support Offices
Distribution Networks
INDEX
Australia
Bangladesh
Brunei
China
India 02 PRECISION SPECIALIST
Indonesia
Japan 05 G-VOLUTION
Laos
Macau 11 INTELLIGENT
Myanmar CONTROLS & DISPLAYS
We at CITEC, are committed to deliver innovative products and
Pakistan
services that are revolutionizing advances the precision cooling
Philippines needs. From design and manufacturing to product and after 15 PRODUCT OVERVIEW
Sri Lanka sales support services, we constantly build upon our proven
innovation of precision, efficiency and creativity to deliver a full
United Arab Emirates 18 TECHNICAL
range of consultancy for customized business needs or an array
Vietnam of designs and models to a myriad of clienteles. SPECIFICATION
Established in Malaysia since 1996, CITEC International has constantly reinvented itself to evolve into one of the
leading manufacturers for precision air conditioning products.
As experts in the field of precision air conditioning, CITEC thrives on Research and Development (R&D) to
deliver innovative products that are of exceptional standards with best performance, reliability and efficiency.
We create real value and business differentiation by taking an integrated approach covering all aspects of our
customers’ businesses.
Today, CITEC has established a wide network of distributors to provide excellent product support and long-
term services to various industries across Asia Oceanic and Pacific regions.
CERTIFICATIONS
G-VOLUTION
CITEC products are engineered to achieve Thus, best performance products with the highest
optimum reliability, eff iciency and ease of eff iciency are guaranteed.
installation and maintenance driven by the needs
of our customers. Products are designed using Our products undergo extensive and stringent tests
sophisticated 3D CAD system and Computational following ASHRAE standards in our well-equipped
Fluid Dynamics (CFD) analysis to ensure optimum
air flow with maximum eff iciency.
testing laboratory facilities accredited with Class A
certif ication by the national authorities. GROUNDBREAKING TECHNOLOGY
EC
Chilled Water series comes with exclusively two different range; EC and
ECL to suit various requirements and applications.
6 G-VOLUTION G-VOLUTION 7
Unique dual coil series, the EH range is designed to provide the highest level of
EH redundancy. There are two types of dual coil system; dual chilled water system or a Panel
combination of direct expansion and chilled water system. The EH range complies
with various applications preventing downtime whilst safeguarding the operations of
your data center. Should a fault be detected in the primary system, the unit operating
condition will be closely monitored while performing the switch from primary to the Panel Insulation
secondary system with CITEC powerful Genius 5+ controller.
Insulation
DESIGN FEATURE
INNOVATIVE MODULAR DESIGN
COMPLIES WITH TECHNOLOGY FULL FRONT
The modular concept ACCESS
offers flexibility in Built-in components
combining two smaller can be easily accessible
size units due to limited from the front which
corridor space. It also significantly improves
allows a combination of the maintainability and
additional unit onto an serviceability of the unit.
+ =
existing installed unit to
meet higher cooling
requirements for future
facility expansion.
8 G-VOLUTION G-VOLUTION 9
ELECTRONIC
EXPANSION VALVE
The innovative Electronic Expansion Valve (EEV)
provides highly efficient control of refrigerant
flow based on real-time feedback. The EEV can
provide fast, stable and precise control even
under low-load condition. The presence of the
temperature and pressure probe allow real time
monitoring of suction temperature and pressure
as well as the superheat of the system.
DIRECT DRIVE
EC FAN SYSTEM
The Electronically Commutated (EC) fan motor combination
offers a number of advantages over traditional belt-driven
forward curved centrifugal blower, such as:
Higher efficiency compared to forward curved fans
Reduced losses due to the absence of pulley and belt
usage in the standard belt-driven fan
ADVANCE COOLING WITH 15-30% more energy savings
UNDERFLOOR EC FAN Variable speed control
An underfloor version of the EC fan is available for Maintenance-free, higher reliability
downflow models. Studies have shown that the Soft start feature, where the fan slowly ramps up to
placement of underfloor EC fans contribute to a the desired speed
10% to 15% improvement in performance and is
recommended for users who would like to utilize the
full capacity of the EC fan. These fans are pre-wired
and pre-packaged into the Precision Air Conditioning
unit prior to delivery for instant installation.
SOLUTION
FOR A
PRECISE &
EFFICIENT
MODBUS RTU protocol can also be connected to BMS directly providing system
monitoring and management. With an optional BMS card, CITEC controller will be able
to connect to other communication protocol as illustrated below:
POWER LIES
Gateway - pCOWEB pCONET
Protocol
WITHIN THE
MODBUS RTU
pCONET MODBUS TCP / IP
INTELLIGENT
BACNET MS / TP
BACNET / IP
CONTROLS &
BACNET ETHERNET
pCOWEB SNMP
Touch screen display provides informative and user-friendly
DISPLAYS
interface for easy navigation. The display can show graphical HTTP
information via animated icons and also capable of plotting FTP
trend graphs for temperature and humidity.
SMTP
At-a-glance reporting on
PRODUCT
performance metrics and
room environment
OVERVIEW
03 Fan Configuration
Crankcase heater*
Hot gas bypass
3-way valve
Screwed water connection
Electronic Pressure Independent Valve (EPIV)
Water In & Out temperature sensor
Centrifugal fan with belt
driven AC motor (Standard) *Standard for Inverter models.
EC fan (Optional)
Note:
This diagram drawing is for illustration purpose only.
Gross Total Capacity kW 9.83 14.72 18.17 20.23 25.70 31.90 35.07 41.64 44.60 49.66 61.86 69.18 82.06 89.38 99.52
Gross Sensible Capacity kW 9.83 12.72 18.17 20.23 23.11 28.17 29.59 41.64 43.21 45.37 61.86 66.48 72.06 86.06 90.42
S.H.R. 1.00 0.86 1.00 1.00 0.90 0.88 0.84 1.00 0.97 0.91 1.00 0.96 0.88 0.96 0.91
GENERAL DATA
8* 12* 15 20 25 30** 35** 40 45 50 60 70 80 90 100
Nominal Air Flow m3/s 1.00 1.00 1.84 1.84 1.84 2.24 2.24 3.70 3.70 3.70 5.30 5.30 5.30 7.20 7.20
No. of Fan(s) 1 1 1 1 1 1 1 2 2 2 2 2 2 3 3
No. of Compressor(s) 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2
No. of Refrigerant Circuit(s) 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2
Sound Level dBA 52 52 61 61 61 62 62 64 64 64 66 66 66 67 67
CONDENSER
8* 12* 15 20 25 30** 35** 40 45 50 60 70 80 90 100
Nominal Air Cooled Model HEC 194 234 234 234 314 374 434 574 574 574 2x374 2x374 2x574 2x574 2x574
Nominal Water Cooled Model WA20 WA30 WB40 WB40 WB60 WB60 WB80 WB80 WB80 WC60 2xWB60 2xWB60 2xWB80 2xWB80 2xWC60
Nominal Water Flow Rate l/s 0.56 0.87 1.04 1.16 1.49 1.85 2.06 2.36 2.53 2.89 3.52 3.93 4.75 5.06 5.80
Waterside Pressure Drop of kPa 36.8 42.8 14.1 17.5 15.9 24.5 21.7 28.3 32.6 57.1 22.1 27.6 28.8 32.7 57.3
Condenser
ELECTRIC RE-HEATER
8* 12* 15 20 25 30** 35** 40 45 50 60 70 80 90 100
ELECTRODE HUMIDIFIER
8* 12* 15 20 25 30** 35** 40 45 50 60 70 80 90 100
Length mm 648 648 800 800 800 885 885 1315 1315 1315 1815 1815 1815 2500 2500
Depth mm 654 654 891 891 891 891 891 891 891 891 891 891 891 891 891
Height mm 1940 1940 1985 1985 1985 1985 1985 1985 1985 1985 1985 1985 1985 1985 1985
Gross Weight - “A” Version kg 165 195 275 275 300 310 310 445 450 450 610 610 617 790 790
- “W” Version kg 173 204 286 287 314 324 326 461 466 466 638 638 645 822 822
Min. Service Allowance mm 600 600 725 725 725 725 725 725 725 725 725 725 725 800 800
Notes:
1. Cooling capacity is based on 24ºC, 45%RH, R407C refrigerant, 45ºC condensing temperature, 400V/3ph+N/50Hz power supply, 50Pa ESP.
TECHNICAL
2. Sound level is for downflow models measured at 1m in free field conditions.
3. Nominal air cooled condenser sizing is suggestion only based on 35ºC ambient & nominal operating condition. Other sizes may be selected to suit requirement as necessary.
4. Nominal water cooled condenser sizing is suggestion only based on water in/out 30/35ºC & nominal operating condition. Other sizes may be selected to suit requirement as
necessary.
5. Water cooled condenser to be installed externally, please consult factory if required to be installed internally.
6. For underfloor EC fan option, raise floor height must be >400mm. *Option not available for model 8 and 12.
7. **For model 30 & 35, only EC fan version is available.
Due to our policy of continuous development and improvement, the specifications and data herein are subjected to change without notice. We must therefore reserve the
SPECIFICATION
right to supply equipment that may differ from that described and illustrated herein. All information, including illustrations, contained in this brochure, is believed to be
accurate and reliable. Users, however, should independently evaluate the suitability of each product for their own application. CITEC makes no warranties as to accuracy or
completeness of the information, and disclaims any liability regarding its use.
UNIT MODEL (ESD/ESU xx A/W) 20 25 30 35 40 45 60 70 80 90 UNIT MODEL (ECD/ECU xxx) 8*** 12*** 25* 30** 50* 60 70 80 95 110 125 135 150
Gross Total Capacity kW 21.06 25.03 30.34 34.92 41.17 46.36 59.70 72.64 79.98 92.81 Downflow
Gross Sensible Capacity kW 21.06 22.82 27.49 29.52 41.17 43.95 59.70 65.74 68.97 87.52 Gross Total Capacity kW 9.67 12.39 24.07 30.27 51.01 64.31 74.71 83.63 100.27 113.93 123.42 131.51 155.54
S.H.R. 1.00 0.91 0.91 0.85 1.00 0.95 1.00 0.91 0.86 0.94 Gross Sensible Capacity kW 9.42 11.65 22.31 27.58 46.08 57.00 66.77 73.76 87.09 99.01 106.18 115.05 133.88
S.H.R. 0.98 0.94 0.93 0.91 0.90 0.89 0.89 0.88 0.87 0.87 0.86 0.88 0.86
GENERAL DATA 20 25 30 35 40 45 60 70 80 90
Upflow
Nominal Air Flow m3/s 1.84 1.84 2.24 2.24 3.70 3.70 5.30 5.30 5.30 7.20 Gross Total Capacity kW 9.67 12.39 24.07 30.27 51.01 61.16 71.20 79.58 95.93 108.20 117.73 127.41 151.06
No. of Fan(s) 1 1 1 1 2 2 2 2 2 3 Gross Sensible Capacity kW 9.42 11.65 22.31 27.58 46.08 54.22 63.76 70.39 83.55 94.22 101.33 111.52 130.11
No. of Compressor(s) 1 1 1 1 1 1 2 2 2 2 S.H.R. 0.98 0.94 0.93 0.91 0.90 0.89 0.90 0.88 0.87 0.87 0.86 0.88 0.86
No. of Refrigerant Circuit(s) 1 1 1 1 1 1 2 2 2 2
Sound Level dBA 62 62 63 63 64 64 66 66 66 67 GENERAL DATA 8*** 12*** 25* 30** 50* 60 70 80 95 110 125 135 150
Nominal Air Flow (Downflow) m3/s 1.00 1.00 1.84 2.24 3.70 4.40 5.20 5.20 6.00 7.00 7.00 7.60 8.60
CONDENSER 20 25 30 35 40 45 60 70 80 90 Nominal Air Flow (Upflow) m3/s 1.00 1.00 1.84 2.24 3.70 4.20 5.00 5.00 5.80 6.70 6.70 7.40 8.40
Nominal Air Cooled Model HEC 234 314 374 434 574 574 2x374 2x434 2x574 2x574 No. of Fan(s) 1 1 1 1 2 2 2 2 2 3 3 3 3
Nominal Water Cooled Model WB40 WB60 WB60 WB80 WB80 WB80 2xWB60 2xWB80 2xWB80 2xWB80 Sound Level dBA 52 52 61 62 64 67 67 67 68 68 68 68 68
Condenser Water Flow Rate l/s 1.22 1.50 1.81 2.12 2.40 2.70 3.49 4.31 4.72 5.41
Waterside Pressure Drop of Condenser kPa 19.6 16.0 23.3 23.0 29.5 37.3 21.7 23.7 28.5 37.3 CHILLED WATER COIL 8*** 12*** 25* 30** 50* 60 70 80 95 110 125 135 150
Downflow
ELECTRIC RE-HEATER 20 25 30 35 40 45 60 70 80 90
Nominal Water Flow l/s 0.46 0.59 1.15 1.45 2.44 3.07 3.57 4.00 4.79 5.44 5.90 6.28 7.43
Nominal Heater Capacity kW 6 6 6 6 12 12 12 12 12 12 Water Pressure Drop kPa 27.4 44.6 34.6 56.6 67.7 107.9 69.2 70.9 107.6 145.4 90.6 60.6 87.2
No. of Heater Step(s) 1 1 1 1 2 2 2 2 2 2
Upflow
Nominal Water Flow l/s 0.46 0.59 1.15 1.45 2.44 2.92 3.40 3.80 4.58 5.17 5.63 6.09 7.22
ELECTRODE HUMIDIFIER 20 25 30 35 40 45 60 70 80 90
Water Pressure Drop kPa 27.4 44.6 34.6 56.6 67.7 104.0 65.8 65.9 101.2 135.0 89.5 59.8 86.5
Nominal Humidifier Capacity kg/hr 5 5 5 5 5 5 5 5 5 8
ELECTRIC RE-HEATER 8*** 12*** 25* 30** 50* 60 70 80 95 110 125 135 150
UNIT DIMENSION & WEIGHT 20 25 30 35 40 45 60 70 80 90
Nominal Heater Capacity kW 6 6 6 6 12 12 12 12 12 12 12 12 12
Length mm 800 800 885 885 1315 1315 1815 1815 1815 2500 No. of Heater Step(s) 1 1 1 1 2 2 2 2 2 2 2 2 2
Depth mm 891 891 891 891 891 891 891 891 891 891
Height mm 1985 1985 1985 1985 1985 1985 1985 1985 1985 1985 ELECTRODE HUMIDIFIER 8*** 12*** 25* 30** 50* 60 70 80 95 110 125 135 150
Gross Weight - “A” Version kg 265 265 275 280 415 430 545 545 570 725
Nominal Humidifier Capacity kg/hr 5 5 5 5 5 5 5 5 8 8 8 8 8
- “W” Version kg 277 279 289 296 431 446 573 573 602 757
Min. Service Allowance mm 725 725 725 725 725 725 725 725 725 800 UNIT DIMENSION & WEIGHT 8*** 12*** 25* 30** 50* 60 70 80 95 110 125 135 150
Length mm 648 648 800 885 1315 1550 1800 1800 2065 2300 2300 2550 2815
Depth mm 654 654 891 891 891 891 891 891 891 891 891 891 891
Height mm 1940 1940 1985 1985 1985 1985 1985 1985 1985 1985 1985 1985 1985
Gross Weight kg 139 165 245 260 355 405 485 505 535 570 595 635 710
Min. Service Allowance mm 600 600 725 725 725 725 725 725 725 725 725 725 725
Notes: Notes:
1. Cooling capacity is based on 24°C, 45%RH, R410A refrigerant, 45°C condensing temperature, 400V/3ph+N/50Hz power supply, 50Pa ESP. 1. Cooling capacity is based on 24ºC, 45%RH, Chilled Water in/out based on 7/12ºC, 400V/3ph+N/50Hz power supply, 50Pa ESP.
2. Sound level is for downflow models measured at 1m in free field conditions. 2. Sound level is measured at 1m in free field conditions.
3. Nominal air cooled condenser sizing is suggestion only based on 35ºC ambient & nominal operating condition. Other sizes may be selected to suit requirement as necessary. 3. For underfloor EC fan option, raise floor height must be >400mm.
4. Nominal water cooled condenser sizing is suggestion only based on water in/out 30/35ºC & nominal operating condition. Other sizes may be selected to suit requirement as 4. For upflow version, only EC fan is available (*except model 25 & 50).
necessary. 5. ** For downflow version, only EC fan is available.
5. Water cooled condenser to be installed externally, please consult factory if required to be installed internally. 6. ***For model 8 & 12, only direct driven/EC fan is available.
6. For underfloor EC fan option, raise floor height must be >400mm.
7. Standard unit comes with fan speed controller, crankcase heater, oil separator & liquid solenoid valve.
Due to our policy of continuous development and improvement, the specifications and data herein are subjected to change without notice. We must therefore reserve the Due to our policy of continuous development and improvement, the specifications and data herein are subjected to change without notice. We must therefore reserve the
right to supply equipment that may differ from that described and illustrated herein. All information, including illustrations, contained in this brochure, is believed to be right to supply equipment that may differ from that described and illustrated herein. All information, including illustrations, contained in this brochure, is believed to be
accurate and reliable. Users, however, should independently evaluate the suitability of each product for their own application. CITEC makes no warranties as to accuracy or accurate and reliable. Users, however, should independently evaluate the suitability of each product for their own application. CITEC makes no warranties as to accuracy or
completeness of the information, and disclaims any liability regarding its use. completeness of the information, and disclaims any liability regarding its use.
C O N D E N S E R
UNIT MODEL HEC 194 234 274 314 374 434 574 654 904
Heat Rejection kW 18.96 22.63 26.64 31.00 37.43 43.04 57.03 65.17 90.46
Air Flow m3/s 2.33 2.10 2.19 2.24 2.53 2.65 4.50 4.60 6.60
No. of Fan(s) 1 1 1 1 1 1 2 2 3
Sound Level dBA 56 56 57 59 60 61 62 62 64
DIMENSION & WEIGHT HEC 194 234 274 314 374 434 574 654 904
Length mm 822 822 862 987 1212 1362 1562 1768 2318
Depth mm 473 473 473 494 494 524 494 494 494
Height mm 825 825 926 926 1028 1155 1063 1063 1063
Header Size 7/8” 7/8” 1 1/8” 1 1/8” 1 1/8” 1 3/8” 1 3/8” 1 3/8” 1 3/8”
Gross Weight kg 56 60 63 75 90 110 125 150 205
L D