Drives Panel Profibus Network
Drives Panel Profibus Network
SIMATIC 300
UR - Rack (0)
  Short description:                   UR
  Order no:                            6ES7 390-1???0-0AA0
  Designation:                         UR
  Comment:
    Addresses
      Inputs
        Start:                         8191
        End:                           8191
-
Send clock:                            1.000 ms
                                                             µÚ   Ò³/¹²   Ò³
SIMATIC
&I-device mode: no
Interconnection
  Local port:                       SIMATIC 300\PN-IO\Port 1 (R0/S2/X2 P1 R)
  Partner port:                     Any partner
Cable
  Medium:                           Copper
  Cable name:                       Copper
  Cable length:                     < 100 m        (Signal delay time: 0.60 µs)
  Delay time:                       0.60 µs
Connection
  Transmission parameters:          Automatic settings
  Monitor:                          no
  Disable autonegotiation:          no
Boundaries
  End of sync domain:               no
  End of detection of accessible    no
  nodes:
  End of topology discovery:        no
Interconnection
  Local port:                       SIMATIC 300\PN-IO\Port 2 (R0/S2/X2 P2 R)
  Partner port:                     Any partner
Cable
  Medium:                           Copper
  Cable name:                       Copper
  Cable length:                     < 100 m        (Signal delay time: 0.60 µs)
  Delay time:                       0.60 µs
Connection
  Transmission parameters:          Automatic settings
  Monitor:                          no
  Disable autonegotiation:          no
                                                                                  µÚ   Ò³/¹²   Ò³
SIMATIC
Boundaries
  End of sync domain:              no
  End of detection of accessible   no
  nodes:
  End of topology discovery:       no
  Addresses
    Inputs
      Start:                       0
      End:                         3
  Addresses
    Inputs
      Start:                       4
      End:                         7
  Addresses
    Inputs
      Start:                       8
      End:                         11
  Addresses
    Outputs
      Start:                       0
      End:                         3
  Addresses
    Outputs
                                                         µÚ   Ò³/¹²   Ò³
SIMATIC
          Start:                     4
          End:                       7
   Addresses
     Inputs
       Start:                        336
       End:                          351
   Addresses
     Inputs
       Start:                        352
       End:                          367
   Addresses
     Outputs
       Start:                        368
       End:                          375
 DP master system:
   Assigned master:
PROFIBUS address 2
     Group: 1
     Comment:
     The group supports SYNC.
     The group supports FREEZE.
Group: 2
                                                           µÚ   Ò³/¹²   Ò³
SIMATIC
   Comment:
   The group supports SYNC.
   The group supports FREEZE.
   Group: 3
   Comment:
   The group supports SYNC.
   The group supports FREEZE.
   Group: 4
   Comment:
   The group supports SYNC.
   The group supports FREEZE.
   Group: 5
   Comment:
   The group supports SYNC.
   The group supports FREEZE.
   Group: 6
   Comment:
   The group supports SYNC.
   The group supports FREEZE.
   Group: 7
   Comment:
   The group supports SYNC.
   The group supports FREEZE.
   Group: 8
   Comment:
   The group supports SYNC.
   The group supports FREEZE.
                                                        µÚ   Ò³/¹²   Ò³
SIMATIC
 Addresses
   Inputs
     Start:                           12
     End:                             15
 Addresses
   Inputs
     Start:                           16
     End:                             19
                                                            µÚ   Ò³/¹²   Ò³
SIMATIC
 Addresses
   Inputs
     Start:                           256
     End:                             271
 Addresses
   Outputs
     Start:                           256
     End:                             271
 Addresses
   Inputs
     Start:                           20
     End:                             23
                                                            µÚ   Ò³/¹²   Ò³
SIMATIC
   Addresses
     Inputs
       Start:                          24
       End:                            27
   Addresses
     Inputs
       Start:                          272
       End:                            287
   Addresses
     Outputs
       Start:                          272
       End:                            287
                                                              µÚ   Ò³/¹²   Ò³
SIMATIC
 Comment:
   - - -
   Diagnostic address:   8181 ...
 Addresses
   Inputs
     Start:              288
     End:                303
 Addresses
   Inputs
     Start:              304
     End:                319
 Addresses
   Inputs
     Start:              320
     End:                335
 Addresses
   Inputs
     Start:              368
     End:                383
 Addresses
   Inputs
     Start:              384
     End:                399
                                               µÚ   Ò³/¹²   Ò³
SIMATIC
 Addresses
   Inputs
     Start:                           400
     End:                             415
 Addresses
   Inputs
     Start:                           416
     End:                             431
 Addresses
   Inputs
     Start:                           432
     End:                             447
                                                             µÚ   Ò³/¹²   Ò³
SIMATIC
 Addresses
   Inputs
     Start:                  448
     End:                    463
 Addresses
   Inputs
     Start:                  464
     End:                    479
 Addresses
   Inputs
     Start:                  480
     End:                    495
 Addresses
   Inputs
     Start:                  496
     End:                    511
 Addresses
   Inputs
                                                   µÚ   Ò³/¹²   Ò³
SIMATIC
          Start:           512
          End:             527
   Addresses
     Outputs
       Start:              288
       End:                295
   Addresses
     Inputs
       Start:              28
       End:                31
   Addresses
     Outputs
       Start:              8
       End:                11
 Slave(10):                PCTM
   Station:                SIMATIC 300
   Subnet:                 PROFIBUS(1)
   PROFIBUS address:       10
   Diagnostics address:    8177 ...
   Order number:           6SL3 040-1MA00-0xxx (CU320-2DP, S120)
   Family:                 SINAMICS
   Device type:            SINAMICS S
   Comment:
   SYNC capability:        Yes
   FREEZE capability:      Yes
   Response monitoring:    Yes
   Slot:                   4
   Drive:
     Type:                 Actual value
     Address:              PZD 1
   PROFIBUS partner:
     Type:                 Input
     PROFIBUS address:     2
     I/O address:          1024
   Length:                 2
                                                                   µÚ   Ò³/¹²   Ò³
SIMATIC
 Unit:                       Word
 Consistency:                Total length
 Comment:                    CU_S_015
 Slot:                       5
 Drive:
   Type:                     Setpoint
   Address:                  PZD 1
 PROFIBUS partner:
   Type:                     Output
   PROFIBUS address:         2
   I/O address:              800
 Length:                     2
 Unit:                       Word
 Consistency:                Total length
 Comment:                    CU_S_015
 Slot:                       6
 Drive:
   Type:                     Axis separator
   Address:
 PROFIBUS partner:
   Type:
   PROFIBUS address:
   I/O address:
 Length:
 Unit:
 Consistency:
 Comment:
 Slot:                       7
 Drive:
   Type:                     Actual value
   Address:                  PZD 1
 PROFIBUS partner:
   Type:                     Input
   PROFIBUS address:         2
   I/O address:              1028
 Length:                     10
 Unit:                       Word
 Consistency:                Total length
 Comment:                    VECTOR_02
 Slot:                       8
 Drive:
   Type:                     Setpoint
   Address:                  PZD 1
 PROFIBUS partner:
   Type:                     Output
   PROFIBUS address:         2
   I/O address:              808
 Length:                     10
 Unit:                       Word
 Consistency:                Total length
 Comment:                    VECTOR_02
Slave(11): LW
                                                   µÚ   Ò³/¹²   Ò³
SIMATIC
   Slot:                   4
   Drive:
     Type:                 Actual value
     Address:              PZD 1
   PROFIBUS partner:
     Type:                 Input
     PROFIBUS address:     2
     I/O address:          864
   Length:                 10
   Unit:                   Word
   Consistency:            Total length
   Comment:                PLW
   Slot:                   5
   Drive:
     Type:                 Setpoint
     Address:              PZD 1
   PROFIBUS partner:
     Type:                 Output
     PROFIBUS address:     2
     I/O address:          344
   Length:                 10
   Unit:                   Word
   Consistency:            Total length
   Comment:                PLW
   Slot:                   6
   Drive:
     Type:                 Axis separator
     Address:
   PROFIBUS partner:
     Type:
     PROFIBUS address:
     I/O address:
   Length:
   Unit:
   Consistency:
   Comment:
   Slot:                   7
   Drive:
     Type:                 Actual value
     Address:              PZD 1
   PROFIBUS partner:
     Type:                 Input
     PROFIBUS address:     2
     I/O address:          844
   Length:                 10
   Unit:                   Word
   Consistency:            Total length
   Comment:                SLW
                                                                   µÚ   Ò³/¹²   Ò³
SIMATIC
 Slot:                       8
 Drive:
   Type:                     Setpoint
   Address:                  PZD 1
 PROFIBUS partner:
   Type:                     Output
   PROFIBUS address:         2
   I/O address:              504
 Length:                     10
 Unit:                       Word
 Consistency:                Total length
 Comment:                    SLW
 Slot:                       9
 Drive:
   Type:                     Axis separator
   Address:
 PROFIBUS partner:
   Type:
   PROFIBUS address:
   I/O address:
 Length:
 Unit:
 Consistency:
 Comment:
Slave(12):                   SW
  Station:                   SIMATIC 300
  Subnet:                    PROFIBUS(1)
  PROFIBUS address:          12
  Diagnostics address:       8173 ...
  Order number:              6SL3 040-1MA00-0xxx (CU320-2DP, S120)
  Family:                    SINAMICS
  Device type:               SINAMICS S
  Comment:
  SYNC capability:           Yes
  FREEZE capability:         Yes
  Response monitoring:       Yes
  Slot:                      4
  Drive:
    Type:                    Actual value
    Address:                 PZD 1
  PROFIBUS partner:
    Type:                    Input
    PROFIBUS address:        2
    I/O address:             1004
  Length:                    10
  Unit:                      Word
  Consistency:               Total length
                                                                     µÚ   Ò³/¹²   Ò³
SIMATIC
Comment: PSW
 Slot:                       5
 Drive:
   Type:                     Setpoint
   Address:                  PZD 1
 PROFIBUS partner:
   Type:                     Output
   PROFIBUS address:         2
   I/O address:              760
 Length:                     10
 Unit:                       Word
 Consistency:                Total length
 Comment:                    PSW
 Slot:                       6
 Drive:
   Type:                     Axis separator
   Address:
 PROFIBUS partner:
   Type:
   PROFIBUS address:
   I/O address:
 Length:
 Unit:
 Consistency:
 Comment:
 Slot:                       7
 Drive:
   Type:                     Actual value
   Address:                  PZD 1
 PROFIBUS partner:
   Type:                     Input
   PROFIBUS address:         2
   I/O address:              984
 Length:                     10
 Unit:                       Word
 Consistency:                Total length
 Comment:                    SSW
 Slot:                       8
 Drive:
   Type:                     Setpoint
   Address:                  PZD 1
 PROFIBUS partner:
   Type:                     Output
   PROFIBUS address:         2
   I/O address:              780
 Length:                     10
 Unit:                       Word
 Consistency:                Total length
 Comment:                    SSW
 Slot:                       9
 Drive:
   Type:                     Axis separator
   Address:
 PROFIBUS partner:
   Type:
   PROFIBUS address:
   I/O address:
 Length:
 Unit:
 Consistency:
 Comment:
                                                   µÚ   Ò³/¹²   Ò³
SIMATIC
DP ID:                                128
Module description:                   Universal module
Output address:                       1500
DP ID:                                128
Module description:                   Universal module
Output address:                       1578
DP ID:                                128
Module description:                   Universal module
Output address:                       1656
DP ID:                                64
Module description:                   Universal module
Input address:                        1500
DP ID:                                64
Module description:                   Universal module
Input address:                        1540
Slave (9)                             DP/DP Coupler, Release 2
  Order number:                        6ES7 158-0AD01-0XA0
  Family:                              Gateway
  DP slave type:                       DP/DP Coupler, Release 2
  Manufacturer:                        Siemens AG
  GSD file name:                       SI018070.GSE
  GSD revision:                        4
  Identification number:               0x8070
  Revision of the DP slave:            2.0
  Hardware release:                    A0
  Software revision level:             B0
  Comment:
  PROFIBUS address :                   9
  Diagnostic address:                  8171
  SYNC:                                Yes
  FREEZE:                              Yes
  Watchdog:                            Turned off
  Parameter assignment in ascending byte sequence (hexadecimal specification) :
                                                                                  µÚ   Ò³/¹²   Ò³
SIMATIC
40,00,00,05,81,00,00,00
DP ID:                     128
Module description:        Universal module
Output address:            1750
DP ID:                     128
Module description:        Universal module
Output address:            1814
DP ID:                     128
Module description:        Universal module
Output address:            1900
DP ID:                     64
Module description:        Universal module
Input address:             1650
Slave(13):                 AW
  Station:                 SIMATIC 300
  Subnet:                  PROFIBUS(1)
  PROFIBUS address:        13
  Diagnostics address:     8170 ...
  Order number:            6SL3 040-1MA00-0xxx (CU320-2DP, S120)
  Family:                  SINAMICS
  Device type:             SINAMICS S
  Comment:
  SYNC capability:         Yes
  FREEZE capability:       Yes
  Response monitoring:     Yes
  Slot:                    4
  Drive:
    Type:                  Actual value
    Address:               PZD 1
  PROFIBUS partner:
    Type:                  Input
    PROFIBUS address:      2
    I/O address:           552
  Length:                  10
  Unit:                    Word
  Consistency:             Total length
  Comment:                 PAW
  Slot:                    5
  Drive:
    Type:                  Setpoint
    Address:               PZD 1
  PROFIBUS partner:
    Type:                  Output
    PROFIBUS address:      2
    I/O address:           300
  Length:                  10
  Unit:                    Word
  Consistency:             Total length
  Comment:                 PAW
  Slot:                    6
  Drive:
    Type:                  Axis separator
    Address:
  PROFIBUS partner:
    Type:
    PROFIBUS address:
    I/O address:
  Length:
  Unit:
                                                                   µÚ   Ò³/¹²   Ò³
SIMATIC
 Consistency:
 Comment:
 Slot:                       7
 Drive:
   Type:                     Actual value
   Address:                  PZD 1
 PROFIBUS partner:
   Type:                     Input
   PROFIBUS address:         2
   I/O address:              532
 Length:                     10
 Unit:                       Word
 Consistency:                Total length
 Comment:                    SAW
 Slot:                       8
 Drive:
   Type:                     Setpoint
   Address:                  PZD 1
 PROFIBUS partner:
   Type:                     Output
   PROFIBUS address:         2
   I/O address:              320
 Length:                     10
 Unit:                       Word
 Consistency:                Total length
 Comment:                    SAW
 Slot:                       9
 Drive:
   Type:                     Axis separator
   Address:
 PROFIBUS partner:
   Type:
   PROFIBUS address:
   I/O address:
 Length:
 Unit:
 Consistency:
 Comment:
Slave(14):                   TLW
  Station:                   SIMATIC 300
  Subnet:                    PROFIBUS(1)
  PROFIBUS address:          14
  Diagnostics address:       8168 ...
  Order number:              6SL3 040-1MA00-0xxx (CU320-2DP, S120)
  Family:                    SINAMICS
  Device type:               SINAMICS S
  Comment:
  SYNC capability:           Yes
  FREEZE capability:         Yes
  Response monitoring:       Yes
                                                                     µÚ   Ò³/¹²   Ò³
SIMATIC
 Slot:                   4
 Drive:
   Type:                 Actual value
   Address:              PZD 1
 PROFIBUS partner:
   Type:                 Input
   PROFIBUS address:     2
   I/O address:          576
 Length:                 2
 Unit:                   Word
 Consistency:            Total length
 Comment:                CU_S_126
 Slot:                   5
 Drive:
   Type:                 Setpoint
   Address:              PZD 1
 PROFIBUS partner:
   Type:                 Output
   PROFIBUS address:     2
   I/O address:          364
 Length:                 2
 Unit:                   Word
 Consistency:            Total length
 Comment:                CU_S_126
 Slot:                   6
 Drive:
   Type:                 Axis separator
   Address:
 PROFIBUS partner:
   Type:
   PROFIBUS address:
   I/O address:
 Length:
 Unit:
 Consistency:
 Comment:
 Slot:                   7
 Drive:
   Type:                 Actual value
   Address:              PZD 1
 PROFIBUS partner:
   Type:                 Input
   PROFIBUS address:     2
   I/O address:          924
 Length:                 10
 Unit:                   Word
 Consistency:            Total length
 Comment:                TLW1
 Slot:                   8
 Drive:
   Type:                 Setpoint
   Address:              PZD 1
 PROFIBUS partner:
   Type:                 Output
   PROFIBUS address:     2
   I/O address:          564
 Length:                 10
 Unit:                   Word
 Consistency:            Total length
                                          µÚ   Ò³/¹²   Ò³
SIMATIC
Comment: TLW1
 Slot:                 9
 Drive:
   Type:               Axis separator
   Address:
 PROFIBUS partner:
   Type:
   PROFIBUS address:
   I/O address:
 Length:
 Unit:
 Consistency:
 Comment:
 Slot:                 10
 Drive:
   Type:               Actual value
   Address:            PZD 1
 PROFIBUS partner:
   Type:               Input
   PROFIBUS address:   2
   I/O address:        884
 Length:               10
 Unit:                 Word
 Consistency:          Total length
 Comment:              TLW2
 Slot:                 11
 Drive:
   Type:               Setpoint
   Address:            PZD 1
 PROFIBUS partner:
   Type:               Output
   PROFIBUS address:   2
   I/O address:        524
 Length:               10
 Unit:                 Word
 Consistency:          Total length
 Comment:              TLW2
 Slot:                 12
 Drive:
   Type:               Axis separator
   Address:
 PROFIBUS partner:
   Type:
   PROFIBUS address:
   I/O address:
 Length:
 Unit:
 Consistency:
 Comment:
 Slot:                 13
 Drive:
   Type:               Actual value
   Address:            PZD 1
 PROFIBUS partner:
   Type:               Input
   PROFIBUS address:   2
   I/O address:        904
 Length:               10
 Unit:                 Word
 Consistency:          Total length
 Comment:              TLW3
 Slot:                 14
 Drive:
                                        µÚ   Ò³/¹²   Ò³
SIMATIC
     Type:                   Setpoint
     Address:                PZD 1
   PROFIBUS partner:
     Type:                   Output
     PROFIBUS address:       2
     I/O address:            544
   Length:                   10
   Unit:                     Word
   Consistency:              Total length
   Comment:                  TLW3
Slave(15):                   SCTM
  Station:                   SIMATIC 300
  Subnet:                    PROFIBUS(1)
  PROFIBUS address:          15
  Diagnostics address:       8166 ...
  Order number:              6SL3 040-1MA00-0xxx (CU320-2DP, S120)
  Family:                    SINAMICS
  Device type:               SINAMICS S
  Comment:
  SYNC capability:           Yes
  FREEZE capability:         Yes
  Response monitoring:       Yes
  Slot:                      4
  Drive:
    Type:                    Actual value
    Address:                 PZD 1
  PROFIBUS partner:
    Type:                    Input
    PROFIBUS address:        2
    I/O address:             1072
  Length:                    2
  Unit:                      Word
  Consistency:               Total length
  Comment:                   CU_S_015
  Slot:                      5
  Drive:
    Type:                    Setpoint
    Address:                 PZD 1
                                                                     µÚ   Ò³/¹²   Ò³
SIMATIC
PROFIBUS partner:
  Type:                      Output
  PROFIBUS address:          2
  I/O address:               828
Length:                      2
Unit:                        Word
Consistency:                 Total length
Comment:                     CU_S_015
Slot:                        6
Drive:
  Type:                      Axis separator
  Address:
PROFIBUS partner:
  Type:
  PROFIBUS address:
  I/O address:
Length:
Unit:
Consistency:
Comment:
Slot:                        7
Drive:
  Type:                      Actual value
  Address:                   PZD 1
PROFIBUS partner:
  Type:                      Input
  PROFIBUS address:          2
  I/O address:               1076
Length:                      10
Unit:                        Word
Consistency:                 Total length
Comment:                     VECTOR_02
Slot:                        8
Drive:
  Type:                      Setpoint
  Address:                   PZD 1
PROFIBUS partner:
  Type:                      Output
  PROFIBUS address:          2
  I/O address:               832
Length:                      10
Unit:                        Word
Consistency:                 Total length
Comment:                     VECTOR_02
Slave(16):                   SUPM
  Station:                   SIMATIC 300
  Subnet:                    PROFIBUS(1)
  PROFIBUS address:          16
  Diagnostics address:       8164 ...
  Order number:              6SL3 040-1MA00-0xxx (CU320-2DP, S120)
  Family:                    SINAMICS
  Device type:               SINAMICS S
                                                                     µÚ   Ò³/¹²   Ò³
SIMATIC
 Comment:
 SYNC capability:        Yes
 FREEZE capability:      Yes
 Response monitoring:    Yes
 Slot:                   4
 Drive:
   Type:                 Actual value
   Address:              PZD 1
 PROFIBUS partner:
   Type:                 Input
   PROFIBUS address:     2
   I/O address:          1282
 Length:                 10
 Unit:                   Word
 Consistency:            Total length
 Comment:                VECTOR_02
 Slot:                   5
 Drive:
   Type:                 Setpoint
   Address:              PZD 1
 PROFIBUS partner:
   Type:                 Output
   PROFIBUS address:     2
   I/O address:          1056
 Length:                 10
 Unit:                   Word
 Consistency:            Total length
 Comment:                VECTOR_02
 Slot:                   6
 Drive:
   Type:                 Axis separator
   Address:
 PROFIBUS partner:
   Type:
   PROFIBUS address:
   I/O address:
 Length:
 Unit:
 Consistency:
 Comment:
 Slot:                   7
 Drive:
   Type:                 Actual value
   Address:              PZD 1
 PROFIBUS partner:
   Type:                 Input
   PROFIBUS address:     2
   I/O address:          1100
 Length:                 2
 Unit:                   Word
 Consistency:            Total length
 Comment:                CU_S_016
 Slot:                   8
 Drive:
   Type:                 Setpoint
   Address:              PZD 1
 PROFIBUS partner:
   Type:                 Output
   PROFIBUS address:     2
   I/O address:          856
 Length:                 2
                                          µÚ   Ò³/¹²   Ò³
SIMATIC
 Unit:                       Word
 Consistency:                Total length
 Comment:                    CU_S_016
Slave(17):                   UWP
  Station:                   SIMATIC 300
  Subnet:                    PROFIBUS(1)
  PROFIBUS address:          17
  Diagnostics address:       8162 ...
  Order number:              6SL3 040-1MA00-0xxx (CU320-2DP, S120)
  Family:                    SINAMICS
  Device type:               SINAMICS S
  Comment:
  SYNC capability:           Yes
  FREEZE capability:         Yes
  Response monitoring:       Yes
  Slot:                      4
  Drive:
    Type:                    Actual value
    Address:                 PZD 1
  PROFIBUS partner:
    Type:                    Input
    PROFIBUS address:        2
    I/O address:             1096
  Length:                    2
  Unit:                      Word
  Consistency:               Total length
  Comment:                   CU_S_017
  Slot:                      5
  Drive:
    Type:                    Setpoint
    Address:                 PZD 1
  PROFIBUS partner:
    Type:                    Output
    PROFIBUS address:        2
    I/O address:             852
  Length:                    2
  Unit:                      Word
  Consistency:               Total length
  Comment:                   CU_S_017
  Slot:                      6
  Drive:
    Type:                    Axis separator
    Address:
  PROFIBUS partner:
    Type:
    PROFIBUS address:
    I/O address:
                                                                     µÚ   Ò³/¹²   Ò³
SIMATIC
Length:
Unit:
Consistency:
Comment:
Slot:                 7
Drive:
  Type:               Actual value
  Address:            PZD 1
PROFIBUS partner:
  Type:               Input
  PROFIBUS address:   2
  I/O address:        1258
Length:               10
Unit:                 Word
Consistency:          Total length
Comment:              UWP1
Slot:                 8
Drive:
  Type:               Setpoint
  Address:            PZD 1
PROFIBUS partner:
  Type:               Output
  PROFIBUS address:   2
  I/O address:        1032
Length:               10
Unit:                 Word
Consistency:          Total length
Comment:              UWP1
Slot:                 9
Drive:
  Type:               Axis separator
  Address:
PROFIBUS partner:
  Type:
  PROFIBUS address:
  I/O address:
Length:
Unit:
Consistency:
Comment:
Slot:                 10
Drive:
  Type:               Actual value
  Address:            PZD 1
PROFIBUS partner:
  Type:               Input
  PROFIBUS address:   2
  I/O address:        1218
Length:               10
Unit:                 Word
Consistency:          Total length
Comment:              UWP2
Slot:                 11
Drive:
  Type:               Setpoint
  Address:            PZD 1
PROFIBUS partner:
  Type:               Output
  PROFIBUS address:   2
  I/O address:        992
Length:               10
Unit:                 Word
Consistency:          Total length
Comment:              UWP2
                                       µÚ   Ò³/¹²   Ò³
SIMATIC
 Slot:                       12
 Drive:
   Type:                     Axis separator
   Address:
 PROFIBUS partner:
   Type:
   PROFIBUS address:
   I/O address:
 Length:
 Unit:
 Consistency:
 Comment:
 Slot:                       13
 Drive:
   Type:                     Actual value
   Address:                  PZD 1
 PROFIBUS partner:
   Type:                     Input
   PROFIBUS address:         2
   I/O address:              1238
 Length:                     10
 Unit:                       Word
 Consistency:                Total length
 Comment:                    UWP3
 Slot:                       14
 Drive:
   Type:                     Setpoint
   Address:                  PZD 1
 PROFIBUS partner:
   Type:                     Output
   PROFIBUS address:         2
   I/O address:              1012
 Length:                     10
 Unit:                       Word
 Consistency:                Total length
 Comment:                    UWP3
Slave(18):                   WP2
  Station:                   SIMATIC 300
  Subnet:                    PROFIBUS(1)
  PROFIBUS address:          18
                                                   µÚ   Ò³/¹²   Ò³
SIMATIC
 Slot:                   4
 Drive:
   Type:                 Actual value
   Address:              PZD 1
 PROFIBUS partner:
   Type:                 Input
   PROFIBUS address:     2
   I/O address:          1048
 Length:                 2
 Unit:                   Word
 Consistency:            Total length
 Comment:                CU_S_018
 Slot:                   5
 Drive:
   Type:                 Setpoint
   Address:              PZD 1
 PROFIBUS partner:
   Type:                 Output
   PROFIBUS address:     2
   I/O address:          804
 Length:                 2
 Unit:                   Word
 Consistency:            Total length
 Comment:                CU_S_018
 Slot:                   6
 Drive:
   Type:                 Axis separator
   Address:
 PROFIBUS partner:
   Type:
   PROFIBUS address:
   I/O address:
 Length:
 Unit:
 Consistency:
 Comment:
 Slot:                   7
 Drive:
   Type:                 Actual value
   Address:              PZD 1
 PROFIBUS partner:
   Type:                 Input
   PROFIBUS address:     2
   I/O address:          1134
 Length:                 10
 Unit:                   Word
 Consistency:            Total length
 Comment:                WP21
 Slot:                   8
 Drive:
   Type:                 Setpoint
                                                                 µÚ   Ò³/¹²   Ò³
SIMATIC
   Address:            PZD 1
 PROFIBUS partner:
   Type:               Output
   PROFIBUS address:   2
   I/O address:        908
 Length:               10
 Unit:                 Word
 Consistency:          Total length
 Comment:              WP21
 Slot:                 9
 Drive:
   Type:               Axis separator
   Address:
 PROFIBUS partner:
   Type:
   PROFIBUS address:
   I/O address:
 Length:
 Unit:
 Consistency:
 Comment:
 Slot:                 10
 Drive:
   Type:               Actual value
   Address:            PZD 1
 PROFIBUS partner:
   Type:               Input
   PROFIBUS address:   2
   I/O address:        1052
 Length:               10
 Unit:                 Word
 Consistency:          Total length
 Comment:              WP22
 Slot:                 11
 Drive:
   Type:               Setpoint
   Address:            PZD 1
 PROFIBUS partner:
   Type:               Output
   PROFIBUS address:   2
   I/O address:        868
 Length:               10
 Unit:                 Word
 Consistency:          Total length
 Comment:              WP22
 Slot:                 12
 Drive:
   Type:               Axis separator
   Address:
 PROFIBUS partner:
   Type:
   PROFIBUS address:
   I/O address:
 Length:
 Unit:
 Consistency:
 Comment:
 Slot:                 13
 Drive:
   Type:               Actual value
   Address:            PZD 1
 PROFIBUS partner:
   Type:               Input
   PROFIBUS address:   2
                                        µÚ   Ò³/¹²   Ò³
SIMATIC
 Slot:                       14
 Drive:
   Type:                     Setpoint
   Address:                  PZD 1
 PROFIBUS partner:
   Type:                     Output
   PROFIBUS address:         2
   I/O address:              888
 Length:                     10
 Unit:                       Word
 Consistency:                Total length
 Comment:                    WP23
Slave(19):                   WP1
  Station:                   SIMATIC 300
  Subnet:                    PROFIBUS(1)
  PROFIBUS address:          19
  Diagnostics address:       8158 ...
  Order number:              6SL3 040-1MA00-0xxx (CU320-2DP, S120)
  Family:                    SINAMICS
  Device type:               SINAMICS S
  Comment:
  SYNC capability:           Yes
  FREEZE capability:         Yes
  Response monitoring:       Yes
  Slot:                      4
  Drive:
    Type:                    Actual value
    Address:                 PZD 1
  PROFIBUS partner:
    Type:                    Input
    PROFIBUS address:        2
                                                                     µÚ   Ò³/¹²   Ò³
SIMATIC
 Slot:                 5
 Drive:
   Type:               Setpoint
   Address:            PZD 1
 PROFIBUS partner:
   Type:               Output
   PROFIBUS address:   2
   I/O address:        968
 Length:               2
 Unit:                 Word
 Consistency:          Total length
 Comment:              CU_S_019
 Slot:                 6
 Drive:
   Type:               Axis separator
   Address:
 PROFIBUS partner:
   Type:
   PROFIBUS address:
   I/O address:
 Length:
 Unit:
 Consistency:
 Comment:
 Slot:                 7
 Drive:
   Type:               Actual value
   Address:            PZD 1
 PROFIBUS partner:
   Type:               Input
   PROFIBUS address:   2
   I/O address:        1154
 Length:               10
 Unit:                 Word
 Consistency:          Total length
 Comment:              WP11
 Slot:                 8
 Drive:
   Type:               Setpoint
   Address:            PZD 1
 PROFIBUS partner:
   Type:               Output
   PROFIBUS address:   2
   I/O address:        928
 Length:               10
 Unit:                 Word
 Consistency:          Total length
 Comment:              WP11
 Slot:                 9
 Drive:
   Type:               Axis separator
   Address:
 PROFIBUS partner:
   Type:
   PROFIBUS address:
   I/O address:
 Length:
 Unit:
 Consistency:
                                        µÚ   Ò³/¹²   Ò³
SIMATIC
Comment:
 Slot:                       10
 Drive:
   Type:                     Actual value
   Address:                  PZD 1
 PROFIBUS partner:
   Type:                     Input
   PROFIBUS address:         2
   I/O address:              1198
 Length:                     10
 Unit:                       Word
 Consistency:                Total length
 Comment:                    WP12
 Slot:                       11
 Drive:
   Type:                     Setpoint
   Address:                  PZD 1
 PROFIBUS partner:
   Type:                     Output
   PROFIBUS address:         2
   I/O address:              972
 Length:                     10
 Unit:                       Word
 Consistency:                Total length
 Comment:                    WP12
 Slot:                       12
 Drive:
   Type:                     Axis separator
   Address:
 PROFIBUS partner:
   Type:
   PROFIBUS address:
   I/O address:
 Length:
 Unit:
 Consistency:
 Comment:
 Slot:                       13
 Drive:
   Type:                     Actual value
   Address:                  PZD 1
 PROFIBUS partner:
   Type:                     Input
   PROFIBUS address:         2
   I/O address:              1174
 Length:                     10
 Unit:                       Word
 Consistency:                Total length
 Comment:                    WP13
 Slot:                       14
 Drive:
   Type:                     Setpoint
   Address:                  PZD 1
 PROFIBUS partner:
   Type:                     Output
   PROFIBUS address:         2
   I/O address:              948
 Length:                     10
 Unit:                       Word
 Consistency:                Total length
 Comment:                    WP13
                                                   µÚ   Ò³/¹²   Ò³
SIMATIC
Slave(20):                   TW
  Station:                   SIMATIC 300
  Subnet:                    PROFIBUS(1)
  PROFIBUS address:          20
  Diagnostics address:       8156 ...
  Order number:              6SL3 040-1MA00-0xxx (CU320-2DP, S120)
  Family:                    SINAMICS
  Device type:               SINAMICS S
  Comment:
  SYNC capability:           Yes
  FREEZE capability:         Yes
  Response monitoring:       Yes
  Slot:                      4
  Drive:
    Type:                    Actual value
    Address:                 PZD 1
  PROFIBUS partner:
    Type:                    Input
    PROFIBUS address:        2
    I/O address:             580
  Length:                    2
  Unit:                      Word
  Consistency:               Total length
  Comment:                   CU_S_020
  Slot:                      5
  Drive:
    Type:                    Setpoint
    Address:                 PZD 1
  PROFIBUS partner:
    Type:                    Output
    PROFIBUS address:        2
    I/O address:             584
  Length:                    2
  Unit:                      Word
  Consistency:               Total length
  Comment:                   CU_S_020
  Slot:                      6
  Drive:
    Type:                    Axis separator
                                                                     µÚ   Ò³/¹²   Ò³
SIMATIC
   Address:
 PROFIBUS partner:
   Type:
   PROFIBUS address:
   I/O address:
 Length:
 Unit:
 Consistency:
 Comment:
 Slot:                 7
 Drive:
   Type:               Actual value
   Address:            PZD 1
 PROFIBUS partner:
   Type:               Input
   PROFIBUS address:   2
   I/O address:        964
 Length:               10
 Unit:                 Word
 Consistency:          Total length
 Comment:              PTW
 Slot:                 8
 Drive:
   Type:               Setpoint
   Address:            PZD 1
 PROFIBUS partner:
   Type:               Output
   PROFIBUS address:   2
   I/O address:        716
 Length:               10
 Unit:                 Word
 Consistency:          Total length
 Comment:              PTW
 Slot:                 9
 Drive:
   Type:               Axis separator
   Address:
 PROFIBUS partner:
   Type:
   PROFIBUS address:
   I/O address:
 Length:
 Unit:
 Consistency:
 Comment:
 Slot:                 10
 Drive:
   Type:               Actual value
   Address:            PZD 1
 PROFIBUS partner:
   Type:               Input
   PROFIBUS address:   2
   I/O address:        944
 Length:               10
 Unit:                 Word
 Consistency:          Total length
 Comment:              STW
 Slot:                 11
 Drive:
   Type:               Setpoint
   Address:            PZD 1
 PROFIBUS partner:
   Type:               Output
   PROFIBUS address:   2
                                        µÚ   Ò³/¹²   Ò³
SIMATIC
Slave(21):                   PUPM
  Station:                   SIMATIC 300
  Subnet:                    PROFIBUS(1)
  PROFIBUS address:          21
  Diagnostics address:       8154 ...
  Order number:              6SL3 040-1MA00-0xxx (CU320-2DP, S120)
  Family:                    SINAMICS
  Device type:               SINAMICS S
  Comment:
  SYNC capability:           Yes
  FREEZE capability:         Yes
  Response monitoring:       Yes
  Slot:                      4
  Drive:
    Type:                    Actual value
    Address:                 PZD 1
  PROFIBUS partner:
    Type:                    Input
    PROFIBUS address:        2
    I/O address:             1302
  Length:                    10
  Unit:                      Word
  Consistency:               Total length
  Comment:                   VECTOR_02
  Slot:                      5
  Drive:
    Type:                    Setpoint
    Address:                 PZD 1
  PROFIBUS partner:
    Type:                    Output
    PROFIBUS address:        2
    I/O address:             1076
  Length:                    10
  Unit:                      Word
  Consistency:               Total length
  Comment:                   VECTOR_02
  Slot:                      6
  Drive:
                                                                     µÚ   Ò³/¹²   Ò³
SIMATIC
   Slot:                     7
   Drive:
     Type:                   Actual value
     Address:                PZD 1
   PROFIBUS partner:
     Type:                   Input
     PROFIBUS address:       2
     I/O address:            1108
   Length:                   2
   Unit:                     Word
   Consistency:              Total length
   Comment:                  CU_S_126
   Slot:                     8
   Drive:
     Type:                   Setpoint
     Address:                PZD 1
   PROFIBUS partner:
     Type:                   Output
     PROFIBUS address:       2
     I/O address:            864
   Length:                   2
   Unit:                     Word
   Consistency:              Total length
   Comment:                  CU_S_126
µÚ Ò³/¹² Ò³