Wega 2.2 C Eng

The Wega 2.2 C is a 3-phase voltage detecting system that indicates the voltage state of a switchgear panel. It has features like integrated maintenance testing, a front accessible interface, fully enclosed electronics, and overvoltage indication. It provides voltage presence indication, maintenance test status, and overvoltage warnings using an LCD display and LEDs. It also has two relay contacts to remotely monitor the voltage state.

Uploaded by

neoph138
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views2 pages

Wega 2.2 C Eng

The Wega 2.2 C is a 3-phase voltage detecting system that indicates the voltage state of a switchgear panel. It has features like integrated maintenance testing, a front accessible interface, fully enclosed electronics, and overvoltage indication. It provides voltage presence indication, maintenance test status, and overvoltage warnings using an LCD display and LEDs. It also has two relay contacts to remotely monitor the voltage state.

Uploaded by

neoph138
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Wega 2.

2 C
Integrated voltage detecting system

Product features
„ Designed according to IEC 61243-5 (VDE 0682-415)
„ Remote: two relay contacts
„ Wide-range Wega (e. g. 10 — 20 / 24 kV): reduction of
variants
„ Integrated maintenance test: maintenance-free
„ Retrofit ready:
connection to ComPass B and Sigma D series
„ Front accessible LRM interface: fully featured according
Wega 2.2 C to IEC 61243-5
„ Fully enclosed electronics: high functional reliability
„ Overvoltage indication: phase-selective

Wega 2.2 C is a 3-phase voltage detecting system, which


Flat connector
indicates the following operating voltage states:

AMP connector Voltage present


Threshold values for voltage presence indica-
tion: 0.1 — 0.45 x Vnom
Voltage present
Integrated maintenance test passed
Back side
Voltage present
L1
Integrated maintenance test passed
L2
Voltage signal too high (overvoltage indication)
L3

C1: Coupling capacitor


Voltage not present
VLE
CL: Cable capacity
C2: Adaption capacitor

Additional to the LCD display the Wega 2.2 C has two LEDs
LRM test socket (green U=0 and red U≠0). With two relay contacts the volt-
age state can be remotely monitored.
Voltage indication The built-in display test function at the front enables
verification of the display of the installed and de-energised
Ground Wega 2.2 C.
For connection, either shielded or unshielded cables with
flat connectors or system connectors can be used.
Principle of an integrated voltage detecting system

Technical data Wega 2.2 C


Nominal voltage 1 — 52 kV (nominal voltage of switchgear, further values on request)
Nominal frequency 50 — 60 Hz
ƒ 3 LRM measuring sockets (one per phase) and 1 earth socket
Interface
ƒ LRM system, 14 mm distance between sockets, with captive anti-dust cap
ƒ LCD display with arrow, dot and wrench tool
Indication
ƒ LED indication, U = 0 and U ≠ 0
Remote signal 2 alternating relay contacts
ƒ LCD display: fed by measuring voltage
Power supply
ƒ Relay and LEDs via 24 — 230 V AC/DC power supply
Housing Polycarbonate, IP54
Temperature range −25 to +65 °C
Dimension drawing in catalogue on page 160, M18

Dipl.-Ing. H. Horstmann GmbH | Humboldtstraße 2 | 42579 Heiligenhaus | T +49 2056 976-0 | F +49 2056 976-140 | www.horstmanngmbh.com | info@horstmanngmbh.com
ABB
Switchgear Switchgear panel Voltage range Input or output Order no.
SafeRing / SafePlus Cable / transformer / circuit breaker 10 — 24 kV Flat connector / AMP V51-2250-105-004

Driescher
Switchgear Switchgear panel Voltage range Input or output Order no.
Minex / Minex-C Cable / transformer / circuit breaker 10 — 20 kV Flat connector / AMP 51-2250-143

Eaton
Switchgear Switchgear panel Voltage range Input or output Order no.
XIRIA Cable / transformer / circuit breaker 10.0 — 17.5 kV Flat connector / AMP 51-2250-116
XIRIA Cable / transformer / circuit breaker 13.8 — 24.0 kV Flat connector / AMP 51-2250-119

Ormazabal
Switchgear Switchgear panel Voltage range Input or output Order no.
ga / gae Cable 10 — 20 kV Flat connector / AMP V51-2250-115-001
ga / gae Transformer 10 — 20 kV Flat connector / AMP V51-2250-106-001
ga / gae Circuit breaker 630 10 — 20 kV Flat connector / AMP V51-2250-119-001
ga / gae Circuit breaker 1250 10 — 20 kV Flat connector / AMP V51-2250-134-001

Schneider Electric
Switchgear Switchgear panel Voltage range Input or output Order no.
FBX C, C1, T1, R, RE 10 — 24 kV Flat connector / AMP 51-2250-136
FBX T2, CB 10 — 24 kV Flat connector / AMP 51-2250-139
RM6 Cable / transformer 10 — 20 kV Flat connector / AMP 51-2250-116

Siemens
Switchgear Switchgear panel Voltage range Input or output Order no.
8DJH Cable / transformer / metering 10 — 21.5 kV Flat connector / AMP 51-2250-124

Required connection cable between Wega and directional fault indicator


Switchgear Output Wega / Input indicator Indicator Cable length Order no.
ABB
Eaton
Lucy Electric AMP / AMP Sigma D and ComPass B 2.0 series 300 mm 49-0509-180
Ormazabal
Schneider Electric (RM6)
ABB
Eaton
Lucy Electric AMP / 4-pole connector ComPass B 300 mm 49-0509-007
Ormazabal
Schneider Electric (RM6)
Driescher AMP / AMP Sigma D and ComPass B 2.0 series 1,300 mm 49-0509-188
Driescher AMP / 4-pole connector ComPass B 1,300 mm 49-0509-024
Schneider Electric (FBX)
Flat connector / AMP Sigma D and ComPass B 2.0 series 300 mm 49-0509-190
Siemens
Schneider Electric (FBX)
Flat connector / 4-pole connector ComPass B 300 mm 49-0509-008
Siemens
Further switchgear types, manufacturer, voltage ranges and cable lengths on request.

Dipl.-Ing. H. Horstmann GmbH | Humboldtstraße 2 | 42579 Heiligenhaus | T +49 2056 976-0 | F +49 2056 976-140 | www.horstmanngmbh.com | info@horstmanngmbh.com