Centri Series Brochure
Centri Series Brochure
Centri
A breakthrough in automated
sample preparation, extraction
and concentration for GC–MS
Centri
®
The Centri family of automated sample extraction and concentration platforms addresses
challenging applications, and can be flexibly tailored to your specific requirements.
Enhanced sensitivity
blockages with controlled, electrical and excellent peak
cooling. 2 shapes are achieved,
particularly for
■ Optimise sample throughput with short
early-eluting gaseous
analytical cycle times thanks to fast trap 0 compounds, in this
cool-down in combination with robust 4 Direct
80-component mix of
sample overlap. headspace VOCs in water (at
20 µg/L). Sizeable
■ Obtain optimum chromatography with all 2 improvements in the
modes of operation, thanks to the signal-to-noise ratios
narrow-bore design providing fast and are obtained when
0
combining Centri 90
efficient desorption of analytes. 0 2 4 6 8 10 12 14 16
Time (min) with GC–MS.
Fast processing of important trace-level applications
Centri 90 boosts throughput and minimises sample preparation with first-class robotic automation, allowing true
unattended operation that supports every stage of the analytical workflow, while delivering clear improvements in
data quality.
Flexibly and rapidly evaluate the advantages of preconcentration using a multi-sorbent, backflushed focusing trap in
Centri 90/Centri 180 while retaining direct GC injection capabilities for existing analyses of HS, SPME, SPME
Arrow and liquid injection samples. In addition, in-built smart traceability features and recording of usage
information improves data confidence, crucial for routine analyses performed in controlled environments.
From solving everyday challenges to providing long-term improvements to data quality in routine analysis,
Markes’ innovative technologies have been optimised for outstanding GC performance.
Benefit from:
■ Versatile water management and selective purging of volatile interferences
■ Advanced sample overlap and prep-ahead mode for increased productivity and quicker time-to-results.
Without overlap
0 min
g
4
din
n
wn
tio
Ethyl acetate
loa
ldo
run
a
1
ub
o
Tra
Inc
GC
Co
Analysis of ‘air toxics’ at ppt to ppm levels: Using hydrogen as a carrier gas it is possible to significantly
reduce the run time while still maintaining excellent separation.
~50% (25) more samples per day with hydrogen = 73 samples in total
$100/sample, therefore,
additional earnings of $2500 per system, per day
Upgradability for ever-growing business demands
Transform your GC(–MS) capabilities with Centri 90:
■ Its small footprint allows seamless integration into your lab
by upgrading existing GC–MS.
■ Trap-enabled workflows provide enhanced sensitivity, while
maintaining direct GC injection capabilities.
■ High sample throughput of up to 300 sample vials is
possible, making it ideal for high-productivity labs.
Centri 90 with robotics: Centri 180 offers all the functionality and advantages of
For both new and existing
GC–MS systems.
Centri 90, plus:
■ Thermal desorption of sorbent-packed tubes, including direct
thermal extraction, for VOCs and SVOCs in air and materials.
■ Full compatibility with industry-standard tubes and therefore
Centri 90: Upgrade
existing PAL3–GC– compliance with standard methods such as ISO 16000-6,
MS systems. VDA 278 and US EPA Method TO-17.
■ HiSorb sorptive extraction: HiSorb probes can be used for
off-line sampling of VOCs and SVOCs in solids and liquids,
with fully automated analysis on Centri 180.
Centri 360
Unrivalled flexibility for full sample characterisation
Centri 360 is highly flexible and modular, enabling complete sample characterisation through complementary analyses on a single
platform. It supports full automation of high-capacity sorptive extraction workflows for the first time, extracting maximum sample
detail with minimum sample preparation.
Harnessing the power of Markes’ backflushed trap, in combination with automated tool changes and more configuration options,
Centri 360 allows you to tackle the most challenging of applications with a high degree of flexibility for sample discovery.
Integrated agitator
ensures efficient
extraction of analytes
■ Patented technology allows automated, unattended
from liquid and solid
high-capacity sorptive extraction for the first time. samples.
■ Short-length probes allow headspace sampling from
20 mL vials (or immersive sampling from 10 mL vials). Intelligent software
allows flexible
■ Standard-length probes allow immersive sampling from sequencing between
20 mL vials. different injection
modes without user
■ Multi-phase combinations available for selective Tube module enables
intervention.
preconcentration of a wide range of polar and fully automated analysis
of up to 50 thermal
non‑polar analytes.
desorption tubes.
■ Once sampled, vials are automatically re-sealed with
special plugs to avoid contamination of laboratory air.
Comprehensive sample profiling Unique re-collection for all sampling modes
Complementary sampling approaches provide comprehensive information about Providing enhanced security for critical,
sample constituents over a wide concentration and volatility range. The flexibility of perishable or limited-size samples,
Centri 360 allows you to easily change between techniques on a single platform, re‑collection allows quantitative, repeat Focusing
analysis without the need to re-sample. trap
making it ideal for non-target research applications such as aroma and flavour profiling.
This also allows simpler and faster Re-collection
Enhanced sample profiling and sample security is enabled by Centri’s proprietary tube
re-collection feature. This allows re-analysis without re-sampling, and enables the method development, provides a means of reliable
dynamic range of the same sample to be extended, to quantify both major and minor data validation, and even permits complementary
components. analysis using different systems or analytical
detectors.
Improve decision making with complementary analyses
2 26 28
Headspace 4 8 13 20 35 39 42 47 48
3
HiSorb
4
4
2 High
3 split
1
1 4 2,3-Butanediol
5 8 3-Methylbutanoic acid
0 13 5-Methylfuran-2-one
0 20 2-Ethyl-3-methyl-
pyrazine
2 Immersive 26 Limonene
4 Low 28 3-Propylpyridine,
HiSorb split 35 Phenylethyl alcohol
39 5-Methyl-6,7-
2 dihydrocyclo-
9
1 pentapyrazine
8 42 3-Phenylfuran
0 47 Pentadecane
48 Octadecane
0 5 10 15
0 Time (min)
20 30 40
Time (min) Quantifying major and minor components from the same sample: An initial high split of freshly
ground coffee, sampled using headspace HiSorb, avoids the risk of system overload for higher-
Analysis of a fabric conditioner using different techniques generated a more abundance components, while a lower split ratio applied to the re-collected sample (automatically
comprehensive fragrance profile. This example shows improved responses for later-eluting, retained on a clean sorbent-packed tube during the original HiSorb analysis) improves responses
less-volatile aroma-active compounds when using immersive HiSorb sampling. and allows trace-level analytes to be detected (labelled).
Uncovering detailed sample information
Seamless workflow integration.
Centri 360 increases sample information obtained for discovery applications, thanks to flexible sampling options and preconcentration.
As a result, more comprehensive approaches can be used to separate, detect and identify the compounds present, and provide additional
dimensions of information about every sample.
Seamless integration of Centri 360 with advanced techniques such as GC×GC provides improved separation to uncover hidden or
co-eluting peaks. When coupled with a mass spectrometer like the BenchTOF2 (SepSolve Analytical Ltd), this provides clearer spectra, and
so improves confidence when performing library matches in non-target screening.
Automated data analysis and intelligent chemometrics software can then be used independently or as part of a complete ‘discovery’
workflow, to quickly find the maximum number of compounds and meaningful trends within complex datasets.
C7H10O
O 95.050
100
110.0742
65.054
50 BenchTOF2
0 P
9.4 ppm
50 NIST
67.000 110.0732
100
95.000
Extract maximum detail. Uncover more compounds. Remove the guesswork. Single software platform. Find the differences.
Superior sample extraction and In addition to 1D GC, The BenchTOF2 delivers ChromSpace software The ChromCompare+ (SepSolve)
enrichment using advanced comprehensive 2D GC can exceptional sensitivity, (SepSolve) integrates full module provides powerful,
techniques combined with provide further analyte reference-quality spectra and instrument control with both automated alignment and
electrically-cooled trap separation, uncovering hidden or powerful mass accuracy, giving qualitative and quantitative data chemometrics tools, to quickly
technology enhances sensitivity co-eluting peaks, to reveal even the confidence to distinguish processing in a single, find key differences between
and data quality. more information in every between candidate structures easy‑to‑use platform. complex chromatograms and
sample. with very similar masses. generate meaningful results.
Ultimate application versatility with Centri 360
Address a wide range of challenging applications with the highest possible sensitivity.
3
4 2 7 in this fragranced shower
1 9
8 10 11 Multi-step enrichment gel is obtained using
1
2 7 (red trace, 3 × 5 mL) immersive high-
2 6 4
3 5 greatly increases the 1
capacity sorptive
6
1 number of important extraction. The large
trace-level aroma 5 phase volume provides
compounds identified in greater sampling capacity
0 this headspace–trap 0 than SPME fibers, ideal
2 3 4 5 6 7 analysis of orange juice. 5 10 15 20 25 for trace-level analysis.
Time (min) Time (min)
Trace-level odorants in water Direct thermal extraction for comprehensive aroma profiling
1 α-Pinene 4 5-Methyl-2-tert-butyl- 7 Tetradecane
in
m
os
IB
M
4 5
2-
P
M
6
IB
5 7
5
A
-TC
Abundance (× 105 counts)
4
4
2,
4 A range of flavour
9 10 compounds are
3
Advance warning of a 3 8 identified in peppermint
100
potential water-quality tea, using direct thermal
2 50
20 problem is made 2 extraction and TD–GC–
2
10 possible by using HiSorb 3 MS to generate a
1 1
5 sampling to uncover 1 comprehensive and
2
1 ppt
ppt-level odorants below representative aroma
0 0
levels detectable to the profile, with no need for
6 7 8 9 human nose. 5 10 15 sample preparation.
Time (min) Time (min)
HiSorb was developed with Welsh Government ‘SMART Cymru’ funding.
Centri®, DiffLok™ and HiSorb™ are trademarks of Markes International.
L-0111 (140323-8)
Markes International
World-leading technologies and unmatched expertise in VOC and SVOC monitoring
Markes International
UK: 1000B Central Park, Western Avenue, Bridgend, CF31 3RT T: +44 (0)1443 230935
USA: 2355 Gold Meadow Way, Gold River, Sacramento, California 95670 T: +1 866-483-5684 (toll-free)
Germany: Bieberer Straße 1–7, 63065 Offenbach am Main T: +49 (0)69 6681089-10
P.R. China: Unit 1002, Building 1, No.418, Guilin Road, Shanghai 200233 T: +86 21 5465 1216
E: enquiries@markes.com W: www.markes.com